F9CC1SAElectricity Meter with Dual RF Transmitters

Schlumberger Sema
Electricity Meter with Dual RF Transmitters - FCC ID F9CC1SA - Schlumberger Sema
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
Apr 14, 2004
Application Purpose
Original Equipment
Date of Application
Apr 14, 2004
Equipment Note
Electricity Meter with Dual RF Transmitters
Frequency Range
917.58000000 - 917.58000000
Company
Schlumberger Sema
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

RF Exposure Info

↗

Test Report

↗
↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 FCC Part 15 Certification Test Report FCC ID: F9CC1SA FCC Rule Part: 15.247 ACS Report Number: 03-0248-15C Manufacturer: Schlumberger Electricity, Inc. Equipment Type: Electricity Meter With Dual RF Transmitters Model: CENTRON ™ ICARe Installation and Operators Guide CENTRON® Meter Technical Reference Guide Effective Date: August 2002 ii Proprietary Rights Notice This manual is an unpublished work and contains the trade secrets and confidential infor- mation of SchlumbergerSema Inc., which are not to be divulged to third parties and may not be reproduced or transmitted in whole or part, in any form or by any means, electronic or mechanical for any purpose, without the express written permission of SchlumbergerSema Inc. All rights to designs or inventions disclosed herein, including the right to manufacture, are reserved to SchlumbergerSema Inc. The information contained in this document is subject to change without notice. Schlum- bergerSema reserves the right to change the product specifications at any time without incurring any obligations. Trademarks Used in This Manual CENTRON is a registered trademark of SchlumbergerSema Inc. PC-PRO+ is a registered trademark of SchlumbergerSema Inc. PRO-READ is a registered trademark of SchlumbergerSema Inc. Windows is a trademark of Microsoft Corporation. CENTRON® Meter Technical Reference Guide RES-CEN-0025-08.02 SchlumbergerSema Energy & Utilities 313-B North Highway 11 West Union, SC 29696 USA Tel: (864) 638-8300 Fax: (864) 638-4950 SchlumbergerSema Energy & Utilities 6700 Century Avenue, Suite 100 Mississauga, Ontario L5N 2V8 Canada Tel: 905-812-2227 Fax: 905-812-5028 Copyright© 2000-2002 SchlumbergerSema Inc. All Rights Reserved. iii Compliance With FCC Regulations FCC Part 15, Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These rules are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential/ commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •Re-orient or relocate the receiving antenna. •Increase the separation between the equipment and the receiver. •Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. •Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC rules. THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION FCC Part 15, Subpart C When equipped with a radio transmitter option, this equipment has been tested and found to comply with the limits for an intentional radiator, pursuant to Part 15, Subpart C of the FCC Rules. This equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instructions, it may cause interference to radio communications. The limits are designed to provide reasonable protection against such interference in a resi- dential situation. However, there is no guarantee that interference will not occur in a partic- ular installation. If this equipment does cause interference to radio or television reception. which can be determined by turning the equipment on and off, the user is encouraged to try to correct the interference by one of more of the following measures: •Reorient or relocate the receiving antenna of the affected radio or television. •Increase the separation between the equipment and the affected receiver. •Connect the equipment and the affected receiver to power outlets on separate circuits. •Consult the dealer or an experienced radio/TV technician for help. Changes or modifications not expressly approved by SchlumbergerSema Inc. could void the user’s authority to operate the equipment. iv Factory Repair of Meters SchlumbergerSema recommends that all repairs be performed at the factory. Certain repairs may be performed by the user; however, unauthorized repairs will void any existing war- ranty. All surface mounted parts must be replaced by the factory. Repair of Meters Under Warranty If the meter is under warranty, then SchlumbergerSema will repair the meter at no charge if the meter has failed due to components or workmanship. A return authorization number must be obtained before the equipment can be sent back to the factory. Contact your SchlumbergerSema Sales Representative for assistance. Repair of Meters Not Under Warranty The same procedure as above applies. SchlumbergerSema will charge for the necessary repairs based on the failure. Service Return Address SchlumbergerSema Customer Repair Department 313 North Highway 11 Dock C West Union, SC 29696 ATTENTION The product you have purchased contains a battery (or batteries), circuit boards, and switches. The batteries are recyclable. At the end of the meter’s useful life, under various state and local laws, it may be illegal to dispose of certain components into the municipal waste system. Check with your local solid waste officials for details about recycling options or proper disposal. This equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instructions manual, this…

Text truncated - open the document above for the full version.

Cover Letter(s)

April 22, 2004 Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen: Schlumberger Electricity, Inc. respectfully requests confidentiality of certain materials provided with the submission of the CENTRON ICARe under FCC ID F9CC1SA in accordance with FCC Regulations 0.459. The confidentiality request applies to the following documents and drawings contained in this filing. • CENTRON ICARe Block Diagram • CENTRON ICARe Schematic Diagram • CENTRON ICARe Parts List (SPL) The CENTRON ICARe has been developed at considerable effort and expense by Schlumberger Electricity, Inc. These items are considered as Trade Secrets and therefore public access to the proprietary material could possibly result in duplication of equipment that could severely damage the company’s business advantage. I appreciate you assistance in this matter. Sincerely, Simon Pontin Vice President of Engineering Date:

External Photos

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 FCC Part 15 Certification Test Report FCC ID: F9CC1SA FCC Rule Part: 15.247 ACS Report Number: 03-0248-15C Manufacturer: Schlumberger Electricity, Inc. Equipment Type: Electricity Meter With Dual RF Transmitters Model: CENTRON ™ ICARe External Photographs Model: CENTRON ™ ICARe Advanced Compliance Solutions FCC ID: FC9CC1SA 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Figure 1: External – Top View

ID Label/Location Info

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 FCC Part 15 Certification Test Report FCC ID: F9CC1SA FCC Rule Part: 15.247 ACS Report Number: 03-0248-15C Manufacturer: Schlumberger Electricity, Inc. Equipment Type: Electricity Meter With Dual RF Transmitters Model: CENTRON ™ ICARe Label Information Resource Management Services, Inc. APPROVALSDATE Copyright c 1998 Schlumberger Page: DOCUMENT NO. DRAWN BY: CHECKED BY: RELEASED FOR INFO. APPROVED BY: 1/ FORMAT OCONEE SCALE PROJECT ENG: MATERIAL: TITLE: ROACH 1/1 442244- 2 UNLESS OTHERWISE SPECIFIED: 1. DIMS. ARE AFTER FINISH 2. DIMS. ARE IN INCHES [MM] 3. TOLERANCES FOR DIMENSIONED FEATURES: 4. ANGLE TOLERANCE DOES NOT APPLY TO 5. DIMENSIONING AND TOLERANCING TO BE IN ACCORDANCE WITH ASME Y14.5 CONFIDENTIAL AND PROPRIETARY INFORMATION NOTICE A1 ZONEREVDESCRIPTIONDATEAPPROVED THIS DOCUMENT CONTAINS TRADE SECRETS AND CONFIDENTIAL INFORMATION OF SCHLUMBERGER RESOURCE MANAGEMENT SERVICES, INC., AND SHALL NOT BE DUPLICATED IN WHOLE OR IN PART OR USED OR DISCLOSED FOR ANY PURPOSE OTHER THAN THAT APPROVED BY SCHLUMBERGER RESOURCE MANAGEMENT SERVICES, INC. COPYRIGHT C 1998 SCHLUMBERGER RESOURCE MANAGEMENT SERVICES, INC. ALL RIGHTS RESERVED. 2-8-99 LABEL, NAMEPLATE FINISHED B COKER2-9-99 2-9-99B COKER REVISIONS A 1 BCDEFGHIJKLMNOP 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 ABCDEFGHIJKLMNOP FINISH: HEAT TREAT:NEXT ASSEMBLY: SIMILAR PARTS: MAKE FROM 442136-001 HEIGHT .120 FACE LEGEND 13-4-99 CL, V, W, TYPE, TA, Kh RH FCC ID: Schlumberger, WATTHOUR METER, USA .060 .080 .100 UTILITY NAME BAR CODE INTERPRETATION CUSTOMER NUMBER SCHLUMBERGER SERIAL NUMBER HEIGHT .120 FACE .025LINE 1 LEGENDREMARKS .120 LINE 2 LINE 3 FM, Hz, CA0.5 LINE 4.200.040 .020 .200 .070.010 LINE 5 LINE 1LINE 2 LINE 3 LINE 5 FIG. 2 PART NO. FIG NO. REMARKS 0011 REV LINE 4 4 0022 442244- 003 004 3 4 REFERENCE UTILITY NAME BAR CODE INTERPRETATION CUSTOMER NUMBER SCHLUMBERGER SERIAL NUMBER HEIGHT .120 FACE .025LINE 1 LEGENDREMARKS LINE 2 LINE 3 LINE 4.200 .200 .040 .020 .200 .070.010 LINE 5 LINE 1LINE 2 LINE 3 LINE 5 CL200 240V 3W TYPE C1S 30TA 1.0Kh WATTHOUR METER LINE 4 USA Schlumberger CA0.5 FM2S 60Hz FCC ID: F9CC1C-1 CUSTOMERS SPECIFICATION NONE NONE FIG. 1 BAR CODE INTERPRETATION SCHLUMBERGER SERIAL NUMBER HEIGHT FACE .025LINE 1 LEGENDREMARKS LINE 2 LINE 3 .200 .250UTILITY NAME / NUMBER .020 .070.010 LINE 5 LINE 1LINE 2 LINE 3 FIG. 3 .140 UTILITY NAME BAR CODE INTERPRETATION CUSTOMER NUMBER SCHLUMBERGER SERIAL NUMBER HEIGHT .120 FACE .025 LINE 5 LINE 1 LEGENDREMARKS LINE 2 LINE 3 LINE 4.040 .020 .070 .140 .250 .010 LINE 5 LINE 1 LINE 5 FIG. 4 LINE 3 LINE 4 LINE 2 BAR CODE .120 INTERPRETATION SCHLUMBERGER SERIAL NUMBER HEIGHT FACE .025LINE 1 LEGENDREMARKS LINE 2 LINE 3 .200.020 .010 LINE 5 LINE 1LINE 2 LINE 3 FIG. 5 UTILITY NAME.120 LINE 5 .200 .140 0055 ECN NEW00373: 001 THRU 004; REVISED FIG’s 1 THRU 4. 9-21-992ECN MEC00593: 004; ON FIG 4 LINE 5 WAS .200RH CUSTOMER SPECIFIC DATA.120.020LINE 6 LINE 6 CUSTOMER SPECIFIC DATA.120.020LINE 6 LINE 6 4 4 4 4 CUSTOMER SPECIFIC DATA.120.020LINE 6 LINE 6 LINE 6 CUSTOMER SPECIFIC DATA.120.020LINE 6 LINE 6 CUSTOMER SPECIFIC DATA.120.020LINE 6 3ECN MEC00668: 001 THRU 005; ADDED CUSTOMER DATA5/11/00WR BAR CODE INTERPRETATION SCHLUMBERGER SERIAL NUMBER HEIGHT FACE .025LINE 1 LEGENDREMARKS LINE 2 LINE 3 .200.020 .010 LINE 5 LINE 1LINE 2 LINE 3 UTILITY NAME.120 LINE 5 FIG. 6 .200 .140 LINE 6 CUSTOMER SPECIFIC DATA.020LINE 6.070 BAR CODE INTERPRETATION SCHLUMBERGER SERIAL NUMBER HEIGHT FACE .025LINE 1 LEGENDREMARKS LINE 2 LINE 3 .250 .070.010 LINE 5 LINE 1LINE 2 LINE 3 .140 LINE 5 CUSTOMER SPECIFIC DATA.120.020LINE 6 LINE 6 FIG. 7 UTILITY NAME.200 .025 1F H1E TIPO Exac 0.5% BAR CODE INTERPRETATION SCHLUMBERGER SERIAL NUMBER HEIGHT FACE .025LINE 1 LEGENDREMARKS LINE 2 LINE 3 .250 .070.010 LINE 5 LINE 1LINE 2 LINE 3 .140 LINE 5 CUSTOMER SPECIFIC DATA.120.020LINE 6 LINE 6 UTILITY NAME.200 .025 FIG. 8 Exac 0.5% FIG. 9 006 007 008 009 6 7 8 9 4 5/2/014ECN DLE02249: 001 THRU 006; ADDED ACCURACY ’CA0.5’ 7 6 6 WR UTILITY NAME BAR CODE INTERPRETATION CUSTOMER NUMBER HEIGHT FACE LINE 1 LEGENDREMARKS LINE 2 LINE 3 LINE 4.200.040 .200 .070.010 .010.070 LINE 2 LINE 3 LINE 4 CUSTOMER SPECIFIC DATA.120.020 LINE 6 LINE 6 NU R300 DEMAND 5/23/015ECN ELE02275: 009; RMVD LINE 5 5/23/016ECN ELE02288: 007, 008; RVSD FIGs 7 & 8 1F H2E TIPO WR WR 010 LINE 1 (RIGHT JUSTIFIED) A10 7/26/017ECN ELE02354: 009, LINE 1 WAS .120 HI x .025 FACEWR A01111 A01212 A01313 014A14 DETROIT EDISON A01515 PROGRESS ENERGY FLORIDA A01616 A01717

Internal Photos

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 FCC Part 15 Certification Test Report FCC ID: F9CC1SA FCC Rule Part: 15.247 ACS Report Number: 03-0248-15C Manufacturer: Schlumberger Electricity, Inc. Equipment Type: Electricity Meter With Dual RF Transmitters Model: CENTRON ™ ICARe Internal Photographs Model: CENTRON ™ ICARe Advanced Compliance Solutions FCC ID: F9CC1SA 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Figure 1: Internal – Front View Model: CENTRON ™ ICARe Advanced Compliance Solutions FCC ID: F9CC1SA 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Figure 2: Circuit Board 1 – Top View Model: CENTRON ™ ICARe Advanced Compliance Solutions FCC ID: F9CC1SA 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Figure 3: Circuit Board 1 – Bottom View

Operational Description

Model: CENTRON ™ ICARe Advanced Compliance Solutions FCC ID: FC9CC1SA FCC Part 15 Certification Test Report FCC ID: F9CC1SA FCC Rule Part: 15.247 ACS Report Number: 03-0248-15C Manufacturer: Schlumberger Electricity, Inc. Equipment Type: Electricity Meter With Dual RF Transmitters Model: CENTRON ™ ICARe Theory of Operation ICARe Project Functional Specification Confidential Page 1 3/23/2004 ICARe Project Functional Specification CDP Requirement 3.1 This document describes the hardware and firmware functional specifications for the project. 23 September 2002 Updated: 15 January 2004 Confidential and Trade Secret Information  Copyright Schlumberger Electricity, Inc., unpublished work, created 2002 ICARe Project Functional Specification Confidential Page 2 3/23/2004 REVISION CHART Version Primary Author(s) Description of Version Date Completed Draft DP McConnell Initial draft 9/23/2002 Draft DP McConnell Incorporated comments from Jerome Bartier, Eric Deschamps and Vladimir Borisov 9/25/2002 Draft DP McConnell Updated document with management requests 9/26/2002 Draft DP McConnell Added R300 functionality 10/1/2002 Draft DP McConnell Added Interval and randomization examples 10/11/2002 Draft DP McConnell Added RF power consumption assumptions 10/14/2002 Draft DP McConnell MCU Requirements made more generic 11/19/2002 Draft DP McConnell Updated document for company split and to address selected MCU 1/16/2002 Draft DP McConnell Changed CRF900 to COSMOS 3/31/2003 Draft DP McConnell Changed CentronCRF to ICARe 4/10/2003 Draft DP McConnell Updated document to reduce overlap with architectural spec 5/15/2003 Draft DP McConnell Inserted Mobile Network Section 7/14/2003 Draft DP McConnell Incorporated comments from Product Services 8/23/2003 Draft M.Peters/P.Chium miento Updated Hardware and Firmware sections 12/19/2003 Preliminary DP McConnell Cleaned up format and made final changes from previous spec 1/15/2004 ICARe Project Functional Specification Confidential Page 3 3/23/2004 TABLE OF CONTENTS 1 Introduction ..........................................................................................................................................................6 1.1 Description ...................................................................................................................................................6 1.2 Endpoint Function .......................................................................................................................................6 2 RF Network Services ............................................................................................................................................7 2.1 SchlumbergerSema CellNet Network System Services ............................................................................7 2.1.1 Information Provided .............................................................................................................................7 2.1.2 FCC Regulation .....................................................................................................................................8 2.1.3 RF Characteristics for Fixed Network ...................................................................................................8 2.2 R300 Mobile Network System ....................................................................................................................8 2.2.1 Information Provided .............................................................................................................................8 2.2.2 FCC Regulation .....................................................................................................................................8 2.2.3 RF Characteristics for Mobile Network.................................................................................................9 2.3 Schlumberger R900 Mobile Network System ...........................................................................................9 2.3.1 Information Provided .............................................................................................................................9 2.3.2 FCC Regulation .....................................................................................................................................9 2.3.3 RF Characteristics for Mobile Network.................................................................................................9 3 System Hardware Requirements ........................................................................................................................10 3.1 Power Supply Specification.......................................................................................................................10 3.1.1 Power supply inputs and outputs description.......................................................................................10 3.1.2 Specification on inputs and outputs .....................................................................................................11 3.1.2.1 Power grid input specification .........................................................................................................11 3.1.2.2 Serial Port interface power input specification ................................................................................11 3.1.2.3 3.4V regulated output specification .................................................................................................11 3.1.2.4 2.65V regulated output specification ...............................................................................................11 3.1.3 Power Supply output current specification ..........................................................................................12 3.2 RF Section Specification............................................................................................................................13 3.2.1 CRF ASIC part ...............................................................…

Text truncated - open the document above for the full version.

RF Exposure Info

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 FCC Part 15 Certification Test Report FCC ID: F9CC1SA FCC Rule Part: 15.247 ACS Report Number: 03-0248-15C Manufacturer: Schlumberger Electricity, Inc. Equipment Type: Electricity Meter With Dual RF Transmitters Model: CENTRON ™ ICARe RF Exposure Information Model: CENTRON ™ ICARe Advanced Compliance Solutions FCC ID: FC9CC1SA 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 General Information: Applicant: Schlumberger Electricity, Inc. ACS Project: 03-0248 FCC ID: FC9CC1SA Device Category: Fixed Mount Environment: General Population/Uncontrolled Exposure Technical Information: Antenna Type: Patcht Antenna Gain: 0dBi Transmitter Conducted Power: 25.33dBm Maximum System EIRP: 25.33dBm Operating Configuration: Mounted on side of residential or commercial structure Exposure Conditions: Greater than 20 centimeters MPE Calculation The minimum separation distance is calculated as follows: E(V/m) = xPxG30 Power Density: P d =(mW/cm 2 ) = d MPE Distance MPE Calculator for Mobile Equipment Limits for General Population/Uncontrolled Exposure* Transmit Freq. (MHz) Radio Power (dBm) Radio Power (W) Antenna Gain (dBi) Antenna Gain (mW eq.) MPE Distance (cm) 917.58 25.33 0.34119 0 1.00 11.3168 Installation Guidelines The installation manual contains the following text advising how to install the equipment to maintain compliance with the FCC RF exposure requirements: “RF Exposure (Intentional Radiators Only) This equipment complies with the FCC RF radiation requirements for uncontrolled environments. To maintain compliance with these requirements, the antenna and any radiating elements should be installed to ensure that a minimum separation distance of 20 cm is maintained from the general population. Conclusion This device complies with the MPE requirements by providing adequate separation between the device, any radiating structure and the general population. E 2 3770

Test Report

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 FCC Part 15 Transmitter Certification Single Channel Direct Sequence Transmitter Test Report FCC ID: F9CC1SA Composite Device FCC Rule Part: 15.247 ACS Report Number: 03-0248-15C247 Manufacturer: Schlumberger Electricity, Inc. Equipment Type: Electricity Meter With Dual RF Transmitters Model: CENTRON ™ ICARe Test Begin Date: January 13, 2004 Test End Date: January 15, 2004 Report Issue Date: February 11, 2004 FOR THE SCOPE OF ACCREDITATION UNDER LAB Code 200612 Reviewed by: Prepared by: Hernando Orozco EMI/EMC Approvals Engineer ACS, Inc. R. Sam Wismer Engineering Manager ACS, Inc. This test report shall not be reproduced except in full. This report may be reproduced in part with prior written consent of ACS, Inc. The results contained in this report are representative of the sample(s) submitted for evaluation. This report contains 10 pages Table of Contents 1.0 General 3 1.1 Introduction 3 1.2 Product Description 3 1.2.1 Intended Use 4 2.0 Location of Test Facility 4 2.1 Description of Test Facility 4 2.1.1 Open Area Test Site 4 2.1.2 Conducted Emissions Test Site 5 3.0 Applicable Standards and References 6 4.0 List of Test Equipment 7 5.0 EUT Setup Block Diagram 7 6.0 Summary of Tests 8 6.1 Section 15.203 - Antenna Requirement 8 6.2 Section 15.207 - Power Line Conducted Emissions 8 6.2.1 Test Methodology 8 6.2.2 Test Results 8 6.3 Section 15.209 - Radiated Emissions (Unintentional Radiation) 9 6.3.1 Test Methodology 9 6.3.2 Test Results 10 6.4 Section 15.247(b)(3) – Peak Output Power 10 6.4.1 Test Methodology 10 6.4.2 Test Results 10 6.5 Section 15.247(a)(2) – 6dB Bandwidth 12 6.5.1 Test Methodology 12 6.5.2 Test Results 12 6.6 Section 15.247(c) - Spurious Emissions 13 6.6.1 Conducted Spurious Emissions 13 6.6.1.1 Test Methodology 13 6.6.1.2 Test Results 13 6.6.2 Radiated Spurious Emissions 13 6.6.2.1 Test Methodology 13 6.6.2.2 Test Results 13 6.7 Section 15.247(d) – Peak Power Spectral Density 14 6.7.1 Test Methodology 14 6.7.2 Test Results 14 7.0 MODIFICATIONS 15 8.0 CONCLUSION 15 Additional Exhibits Included In Filing Conducted Spurious Plots Schematics Radiated Spurious Plots Internal Photographs Bill of Materials External Photographs System Block Diagram Test Setup Photographs Operational Description Product Labeling Info Manual RF Exposure – MPE Calculations Model: CENTRON ™ ICARe FCC ID: FC9CC1SA ACS Report: 03-0248-15C Advanced Compliance Solutions Page 3 1.0 GENERAL 1.1 Introduction The purpose of this report is to demonstrate compliance of a composite device to 15.247 of the FCC’s Code of Federal Regulations. A separate filing under the same FCC ID will be made under 15.249 of the rules. 1.2 Product Description The ICARe will be a transmit-only meter module that collects and transmits metering data over the 902 - 928 MHz Industrial, Scientific and Medical (ISM) RF band. The unit will contain both a Direct Sequence Spread Spectrum (DSSS) transmitter and a Low Power Frequency Hopping (FSK) transmitter. The ICARe functions as a RF transmitter that will support remote meter reading using both the mobile and the fixed network protocols. The mobile network functions will be the R300 (ITRON™ protocol) or the R900 (SURF© protocol). The fixed network function will be the CellNet© electricity endpoint protocol (PID2) to maintain legacy functionality. The endpoint will be installed in the CENTRON meter as the register board. The metrology board will provide power and energy data to the endpoint in the same manner as a normal register board. The endpoint will provide the following data depending on configuration: • Cumulative energy readings using the ITRON protocol • Cumulative energy readings using the Schlumberger SURF protocol • Cumulative and interval readings using the SchlumbergerSema CellNet protocol The endpoint will be able to transmit a combination of the fixed and one of the two mobile protocols in a deployment to support the ‘Agile’ network or any single protocol above based on the configuration loaded. The endpoint will determine electrical energy data by counting pulses from the metrology board and then converting them to energy values for display and transmission. The endpoint will use a constant loaded during configuration to provide the correct energy values for the network being supported. The endpoint will also use a serial protocol for configuration and testing using the register serial port. It is also necessary for the endpoint to be able to be installed on previous meter bases with no modifications to the base to maintain the modularity requirement of the CENTRON meter. Detailed photographs of the EUT are filed separately with this filing. Model: CENTRON ™ ICARe FCC ID: FC9CC1SA ACS Report: 03-0248-15C Advanced Compliance Solutions Page 4 1.2.1 Intended Use The CENTRON ™ ICARe is intended to be installed on a residential or commercial structure to record electricity usage and transmit the data to either utility personnel or to a nearby base station depending on which radio is active. Only one radio will ever be active at any given time. If the meter is configured for remote meter data collection by a utility meter reader, the low power radio will be activated. If the meter is configured for base station data collection the higher power direct sequence radio will be activated. The radios are configured at the factory and cannot be activated by the end user or utility personnel. 2.0 LOCATION OF TEST FACILTY All testing was performed by qualified ACS personnel located at the following address: ACS, Inc. 5015 B.U. Bowman Drive Buford, GA 30518 2.1 DESCRIPTION OF TEST FACILITY Both the Open Area Test Site(OATS) and Conducted Emissions site have been fully described, submitted to, and accepted by the FCC, Industry Canada and the Japanese Voluntary Control Council for Interference by information technology equipment. In addition, ACS is compliant to ISO 17025 as certified by the National I…

Text truncated - open the document above for the full version.

Test Report

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 FCC Part 15 Certification Test Report FCC ID: F9CC1SA FCC Rule Part: 15.247 ACS Report Number: 03-0248-15C Manufacturer: Schlumberger Electricity, Inc. Equipment Type: Electricity Meter With Dual RF Transmitters Model: CENTRON ™ ICARe Conducted Spurious Emissions

Test Report

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 FCC Part 15 Certification Test Report FCC ID: F9CC1SA FCC Rule Part: 15.247 ACS Report Number: 03-0248-15C Manufacturer: Schlumberger Electricity, Inc. Equipment Type: Electricity Meter With Dual RF Transmitters Model: CENTRON ™ ICARe Radiated Spurious Emissions

Test Setup Photos

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 FCC Part 15 Certification Test Report FCC ID: F9CC1SA FCC Rule Part: 15.247 ACS Report Number: 03-0248-15C Manufacturer: Schlumberger Electricity, Inc. Equipment Type: Electricity Meter With Dual RF Transmitters Model: CENTRON ™ ICARe Test Setup Photographs Model: CENTRON ™ ICARe Advanced Compliance Solutions FCC ID: FC9CC1SA 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Figure 1: Radiated Emissions – Front View Model: CENTRON ™ ICARe Advanced Compliance Solutions FCC ID: FC9CC1SA 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Figure 2: Radiated Emissions – Rear View Model: CENTRON ™ ICARe Advanced Compliance Solutions FCC ID: FC9CC1SA 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 Figure 3: Conducted Emissions – Front View

Contact Information

Applicant

Lee Littlejohn(Compliance Engineer)
[email protected]864-638-4761Fax: 864-638-4900

Test Firm

Advanced Compliance Solutions, Inc.Douglas Massey
[email protected]770-831-8048Fax: 770-831-8598

Technical Specifications

#Rule PartsFrequency RangePower Output
115C917.58 MHz - 917.58 MHz341.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Schlumberger Sema

ELECTRICITY METER WITH DUAL RF TRANSMITTERS - FCC ID F9CC1A-1 - Schlumberger Sema
F9CC1A-1

ELECTRICITY METER WITH DUAL RF TRANSMITTERS

May 12, 2004

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Wireless LAN Radio - FCC ID F9CSMFMM-1 - Schlumberger Sema
F9CSMFMM-1

Wireless LAN Radio

Nov 14, 2002

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
BLT 3 LAN Transceiver - FCC ID F9C26-0288 - Schlumberger Sema
F9C26-0288

BLT 3 LAN Transceiver

Aug 27, 2002

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Utility Meter Transmitter - FCC ID F9C-CBAMM - Schlumberger Sema
F9C-CBAMM

Utility Meter Transmitter

May 03, 2002

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Wireless Power Meter - FCC ID F9CC1C-3 - Schlumberger Sema
F9CC1C-3

Wireless Power Meter

Apr 30, 2002

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter