FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Visonic Inc./
  3. GSAMCS710

GSAMCS710Wireless Siren

Visonic Inc.
Wireless Siren - FCC ID GSAMCS710 - Visonic Inc.
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Oct 16, 2006
Application Purpose
Original Equipment
Date of Application
Oct 16, 2006
Equipment Note
Wireless Siren
Frequency Range
315.00000000 - 315.00000000
Company
Visonic Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Operational Description

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

DE5421 1 MCS MCSMCS MCS- -- -7 77 71 11 10 00 0 Fully Wireless Siren Installation Instructions 1. INTRODUCTION 1. INTRODUCTION1. INTRODUCTION 1. INTRODUCTION The MCS-710 is an indoor or outdoor fully wireless siren, designed for installation in areas in which wiring action is difficult or impossible. There is no need for an external power supply. The MCS-710 is powered by an internal non-chargeable battery. The siren communicates with the PowerMax+ wireless alarm control system. When an identified activation command is received from the PowerMax+, the siren activates its sounder, activates its flash lights and acknowledges its activation to the PowerMax+. The MCS-710 and the alarm control system should be located in the same house. MCS-710 Features • Designed for indoor or outdoor use The siren has double plastic cover for extra protection against rain and sun. • Distinguishable siren fire and burglar alarms Fire alarm: Alternating on/off alarm sound. Burglary alarm: Continuous high/low tone sweep. Note: The siren is activated for a predefined "Bell Time" (refer to PowerMax+ installer guide, par. 4.4) according to local authorities requirements. After this period, the siren sound stops. • Squawk indications High, mid or low siren squawk (beep) sounds can be used to indicate PowerMax+ arming (1 squawk) and disarming (2 squawks) by a keyfob (see PowerMax+ user's guide par. 7.13). • Flash lights The siren includes 6 flash lights that are activated as follows: A. When an identified activation command is received from the PowerMax+, the siren starts sounding for a predetermined time (set by the PowerMax+ "4. DEFINE PANEL", "04: BELL TIME" menu). (The siren sound can be stopped by PowerMax+ disarming). After the siren sounding period (if the PowerMax+ is not disarmed) the siren lights flash once every 1 second (0.1 second ON, 0.9 second OFF) for a period of 20 minutes, or until the PowerMax+ is disarmed. B. When the battery voltage is low, the lights flash once every 5 seconds (for low voltage indication). C. When there is no communication between the siren and the PowerMax+, the lights flash once every 5 seconds, for communication failure indication. • Triple Tamper protection 3 tamper switches are included; one on side cover, second touching the mounting surface and third attached to the closure screw. Figure 1 - External View • Non-rechargeable 3.6V Lithum battery When the battery voltage is low, low battery message is sent to the PowerMax+. After the low voltage message delivery, at least 2 siren alarms will be possible before the siren will be totally inactive. • 2-way full supervision The siren is fully supervised, 2-way communication device. It includes a receiver, to receive activation commands from the alarm system, and a transmitter, to periodically transmit its status signal to the alarm system. The transmitted signal strength can be measured during the installation (refer to PowerMax+ installer guide, paragraph 5.2 – Diagnostic Test). • Self-test feature Upon pressing the MCS-710 self test switch for 3 seconds, the siren functional check is performed (low level sounds and flash lights indicate that that siren is serviceable). MCS-710 Hard wired detector Emergency pendant transmitter Smoke detector Universal perimeter protection detector Door or window open/close detector Motion detector Remote commander Figure 2- Integration with the Alarm System Note: When the PowerMax+ is removed or its power is switched off for a long period, the siren internal battery should be removed to preserve battery life. 2. SPECIFICATIONS 2. SPECIFICATIONS2. SPECIFICATIONS 2. SPECIFICATIONS Siren Type: Piezo, 100dB min. SPL @ 1m, 1.8-2.3 kHz, sweep frequency 7Hz Internal Battery: 3.6V non-rechargeable Lithum battery, EEMB type ER34615M Battery life expectancy: 3 years (for typical use) Operating Frequency (MHz): 315, 433.92, 868.95, or other frequency according to the requirement in the country of use. Receiver and Transmitter ID Type: 24-bit Flash Lights Duration: 100ms ON, 900ms OFF Dimensions (LxWxD): 30 x 19 x 7 cm (11-13/16 x 7-1/2 x 2-3/4 in) Weight: 982g (34.6 oz.) Operating Temperature: -30°C to 70°C (-22°F to 158°F) Compliance with Standards: EN 50131-1 Grade 2 Class II 2 DE5421 3. INSTALLATION 3. INSTALLATION3. INSTALLATION 3. INSTALLATION, TESTING AND ENROLLING , TESTING AND ENROLLING, TESTING AND ENROLLING , TESTING AND ENROLLING Remove screw and remove cover 1 5 ENROLLING Press SF TST (Self-Test) switch for 5 seconds minimum. Verify that the siren sounds (low level sound) and that the lights flash. SELF TEST Mark and drill 4 holes (as desired) in mounting surface, fasten the siren to the surface with four 6 cm screws. 2 Battery Perform enrolling procedure as described in PowerMax+ installer guide (par. 4 .2). When TRANSMIT NOW is displayed, press the siren SF TST (Self Test) switch 2-3 seconds and release. PowerMax+ should indicate a successfull enrolling. Press the SF TST button again if needed. 4 Locate the battery, tighten it with tightening strap and connect the battery connector. 3 BATTERY BATTERY & BATTERY TIGHTENING STRAP Figure 3 – Installation, Testing and Enrolling Notes a. Pressing the Self-Test switch for 3 seconds is used for testing the siren (by using low level sound) and its flash light. b. Pressing the Self-Test switch momentarily is used to enroll the siren in the PowerMax+ memory (The PowerMax+ must recognize the siren unique identification code for command delivery and supervision). c. After the enrolling, close the siren cover and perform DIAGNOSTIC TEST, as described in PowerMax+ installer guide par. 5.2. d. Enrolling cancellation, if required, is described in the PowerMax+ Installer Guide. e. Before removing the siren form the mounting surface: 1. Perform deleting the siren enrolling in the control panel. 2. Enter Installer Mode and enter Installer Code and then you can remove the siren without activating the siren. Interference Prevention This device complies with FCC…

Text truncated - open the document above for the full version.

Block Diagram

Visonic Ltd. FCC ID:GSAMCS710 Page 1 of 1 Block diagram of MCS710 Wireless Siren

Cover Letter(s)

October 8, 2006 American TCB 6731 Whittier Ave. American TCB 6731 Whittier Ave Suite C110 McLean, VA 22101 USA Subject: Application for certification of the wireless siren, operating at 315 MHz, FCC ID:GSAMCS710 Dear Gentlemen, Please find attached our application for certification of the wireless siren, operating at 315 MHz, FCC ID:GSAMCS710, prepared in accordance with FCC Rules, parts 15 and 2. The product testing and this application for certification were performed by Hermon Laboratories, which is listed by FCC, Registration Numbers 90623, 90624. Hermon Labs responsible person is Mr. Alex Usoskin, tel: 011 972 4628 8001, fax:011 972 4628 8277, e-mail: [email protected]. Please send an invoice to Hermon Labs. We hope this application satisfies your requirements. Arick Elshtein, International Standards Manager

Cover Letter(s)

October 8, 2006 American TCB 6731 Whittier Ave. American TCB 6731 Whittier Ave Suite C110 McLean, VA 22101 USA Subject: Request for confidentiality, FCC ID:GSAMCS710 Dear Gentlemen, In regards the exhibits submitted in support of the application for FCC ID:GSAMCS710, please classify the following as confidential under the provision of 47 CFR 0.459: 1) Schematic diagram, file “Schematic_diagram_Tx_16961” (1 page) 2) Schematic diagram, file “Schematic_diagram_Rx_16961” (1 page). The above material contains trade secrets or technical data which Visonic Ltd. deems to be proprietary. Therefore this information would customarily be guarded from competitors and cannot be accessible to the general public. Arick Elshtein, International Standards Manager

External Photos

Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 1 of 3 EXTERNAL PHOTOGRAPHS This document contains 2 photographs Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 2 of 3 Photograph No.1 MCS710 wireless siren front view Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 3 of 3 Photograph No.2 MCS710 wireless siren rear view

ID Label/Location Info

ECM Title: VISONIC LABEL DRAWING VISONIC LTD. Product Name: LABLE MCS-710 FCC Date Name Document No: 03.10.2006 YANA K. Created Document Rev: 00 Updated Sheet 1 of 1 Arik E. Approved FCC ID:GSAMCS710 1 MATERIAL: PVC S-0002-A SIZE: 40x65 mm NOTES: MCS-710 (315)– Variable (Product description) 90-5421-1- Variable (Product Cat. No.) A- Variable (Product Revision) WW – Week Variable YY- Year Variable XXXXXX- Numerator. Variable, increment by 1, became equal to 00001 every new week. Barcode- Code 128 Other Fields: - Fixed FCC ID:GSAMCS710 2 Label location Label with FCC ID:GSAMCS710 will be located at the bottom panel

Internal Photos

Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 1 of 14 INTERNAL PHOTOGRAPHS This document contains 13 photographs Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 2 of 14 Photograph No.1 MCS710 wireless siren general internal view Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 3 of 14 Photograph No.2 MCS710 wireless siren internal view Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 4 of 14 Photograph No.3 MCS710 wireless siren internal view with cover removed Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 5 of 14 Photograph No.4 MCS710 close internal view Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 6 of 14 Photograph No.5 MCS710 PCB front view Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 7 of 14 Photograph No.6 MCS710 PCB second side view Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 8 of 14 Photograph No.7 PCB front view with transmitter and receiver removed Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 9 of 14 Photograph No.8 MCS710 transmitter view Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 10 of 14 Photograph No.9 MCS710 transmitter module top view Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 11 of 14 Photograph No.10 Transmitter PCB second side view Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 12 of 14 Photograph No.11 MCS710 receiver module view Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 13 of 14 Photograph No.12 Receiver top view Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 14 of 14 Photograph No.13 Receiver PCB second side view

Operational Description

Visonic Ltd. FCC ID:GSAMCS710 MCS-710 operational description The MCS 710 is a wireless siren/sounder powered by Lithium non-rechargeable batteries, to be used in conjunction with Visonic's burglar alarm control panel. The siren hass communication via its RF (315 MHz) data link with the control panel. It is communicating via it RFR receiver module and RFT transmitter module, both of which are controlled by its microprocessor. The type of RF modulation used is ASK (ON OFF KEYING). The RFR module has a small helical antenna which is a part of the module, while the RFT has a straight wire antenna. The siren reacts to the control panel instruction, but has also autonomous operations such as self test, light flashing, and reporting on batteries (low) status, as well as "tampering sensors which report on whether the housing cover is removed or the unit is shifted from its fixed installation.

Test Report

Hermon Laboratories Ltd. P.O.Box 23, Binyamina 30500, Israel Tel. +972 4628 8001 Fax. +972 4628 8277 E-mail: [email protected] Page 1 of 45 Report ID: VISRAD_FCC.16961.doc Date of Issue: 8/21/2006 Electrical TEST REPORT ACCORDING TO: FCC CFR 47 PART 15 Subpart C, section 15.231 and subpart B; RSS-210, Issue 6, Annex 1; ICES-003 Issue 4:2004 FOR: Visonic Ltd. Wireless siren Model:MCS 710 TX/RX 315M This report is in conformity with ISO/ IEC 17025. The A2LA logo endorsement applies only to the test methods and the standards that are listed in the scope of Hermon Laboratories accreditation. The test results relate only to the items tested. This test report shall not be reproduced in any form except in full with the written approval of Hermon Laboratories Ltd. Report ID: VISRAD_FCC.16961.doc Date of Issue: 8/21/2006 Page 2 of 45 Table of contents 1 Applicant information..................................................................................................................................................... 3 2 Equipment under test attributes .................................................................................................................................... 3 3 Manufacturer information .............................................................................................................................................. 3 4 Test details.................................................................................................................................................................... 3 5 Tests summary.............................................................................................................................................................. 4 6 EUT description............................................................................................................................................................. 5 6.1 General information....................................................................................................................................................... 5 6.2 Changes made in the EUT ............................................................................................................................................ 5 6.3 EUT general view .......................................................................................................................................................... 5 6.4 Transmitter characteristics ............................................................................................................................................ 6 7 Transmitter tests according to 47CFR part 15 subpart C requirements ........................................................................ 7 7.1 Periodic operation requirements ................................................................................................................................... 7 7.2 Field strength of emissions.......................................................................................................................................... 10 7.3 Occupied bandwidth test ............................................................................................................................................. 23 7.4 Antenna requirements ................................................................................................................................................. 25 8 Unintentional emissions .............................................................................................................................................. 26 8.1 Radiated emission measurements .............................................................................................................................. 26 9 APPENDIX A Test equipment and ancillaries used for tests....................................................................................... 33 10 APPENDIX B Measurement uncertainties................................................................................................................... 34 11 APPENDIX C Test facility description ......................................................................................................................... 35 12 APPENDIX D Specification references ....................................................................................................................... 35 13 APPENDIX E Abbreviations and acronyms................................................................................................................. 36 14 APPENDIX F Test equipment correction factors ......................................................................................................... 37 Report ID: VISRAD_FCC.16961.doc Date of Issue: 8/21/2006 Page 3 of 45 1 Applicant information Client name: Visonic Ltd. Address: 24, Habarzel street, Tel Aviv, Israel, 69710 Telephone: +972 3645 6714 Fax: +972 3645 6891 E-mail: [email protected] Contact name: Mr. Arick Elshtein 2 Equipment under test attributes Product name: Wireless siren Product type: Transciever Model(s): MCS 710 TX/RX 315M Receipt date 4/3/2006 3 Manufacturer information Manufacturer name: Visonic Ltd. Address: 24, Habarzel street, Tel Aviv, Israel, 69710 Telephone: +972 3645 6714 Fax: +972 3645 6891 E-Mail: [email protected] Contact name: Mr. Arick Elshtein 4 Test details Project ID: 16961 Location: Hermon Laboratories Ltd. P.O.Box 23, Binyamina 30500, Israel Test started: 4/3/2006 Test completed: 7/30/2006 Test specification(s): FCC Part 15, subpart C, ß15.231; subpart B, ß15.109; RSS-210 Issue 6:2005, Annex 1; ICES-003 issue 4:2004 Test suite: FCC_15.231(a) and RSS-210_6.1.1 (5/10/2004 8:29:24 AM, modified) Report ID: VISRAD_FCC.16961.doc Date of Issue: 8/21/2006 Page 4 of 45 5 Tests summary Test Status Transmitter characteristics FCC Part 15, Section 231(a) / RSS-210, Section A1.1.1, Periodic operation requirements Pass FCC Part 15, Section 231(b) / RSS-210, Section A1.…

Text truncated - open the document above for the full version.

Test Setup Photos

Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 1 of 6 SETUP PHOTOGRAPHS This document contains 5 photographs Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 2 of 6 Photograph No.1 Spurious radiated emissions measurement setup in the anechoic chamber with loop antenna Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 3 of 6 Photograph No.2 Radiated emissions measurement setup in the anechoic chamber with biconilog antenna Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 4 of 6 Photograph No.3 Radiated emissions measurement setup in the anechoic chamber, close view Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 5 of 6 Photograph No.4 Radiated emissions measurement setup at the OATS with log periodic antenna Visonic Ltd. FCC ID:GSAMCS710 Date: October 2006 Page 6 of 6 Photograph No.5 Occupied bandwidth measurement setup

Contact Information

Applicant

Scott Jensen(Tec Manager)
860-243-0833

Technical Contact

Hermon LabsAlex Usoskin
[email protected]972-4528-8001

Harakevey Industrial Zone · Binyamina · Israel

Test Firm

Hermon LaboratoriesGeorge Shleimovich
[email protected]972-4-6288001Fax: +972 4 6288277

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231315 MHz - 315 MHz-
Confidentiality
Long Term

Other Applications from Visonic Inc.

Infant Protection Bracelet - FCC ID GSA5-BTC00433 - Visonic Inc.
GSA5-BTC00433

Infant Protection Bracelet

Nov 14, 2007

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
PANIC WATCH - FCC ID GSAWPK250 - Visonic Inc.
GSAWPK250

PANIC WATCH

Jun 03, 2007

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
LF Exciter - FCC ID GSA5-RLE00125B - Visonic Inc.
GSA5-RLE00125B

LF Exciter

May 28, 2007

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Dual-Technology Microwave/PIR Intrusion Detector - FCC ID GSADUETAM - Visonic Inc.
GSADUETAM

Dual-Technology Microwave/PIR Intrusion Detector

May 16, 2007

Equipment Class

FDS - Part 15 Field Disturbance Sensor
Supervised Indoor Wireless CO Gas Detector - FCC ID GSAMCT442 - Visonic Inc.
GSAMCT442

Supervised Indoor Wireless CO Gas Detector

May 01, 2007

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter