Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
T O U C H T R O N I C S, I N C. v 57315 Nagy Drive web site address: www.touchtronics.com ph: 574-294-2570 Elkhart, IN 46517 e-mail address: [email protected] fx: 574-293-1611 Owner’s Manual PowerTouch 1000 – RF Remote Control Systems By TouchTronics, Inc. Specifications 1000 Series Receiver Input Power Standard 9 – 16 Volt DC (12 Volt DC Nominal), 10A Max Optional 30A Max Optional 24 Volt DC Outputs Current 5 Amps Max per Output Option 1 4 Momentary or Latching Relays Option 2 6 Momentary or Latching + 1 Timed Relays Inputs RF Signal and Wired (2 std, 8 optional) Inputs Frequency 433 MHz Range Typical 100 Feet Clear Field 300 Feet Codes Number Over 250,000,000 Type Digital Rolling Codes Enrolling Self-Learning 1000 Series Transmitter Frequency 433 MHz Battery Lithium, Coin Style (CR2032) Voltage 3 Volt DC Cycles 50,000 2-Second Presses (approx) Codes Over 250,000,000, Type: Digital Rolling Codes Configuration 2, 4 or 6 Buttons, or Four Wired Inputs Transmission Timeout No Timeout Lockout Timer Optional 3 Minute Timer Battery Status LED Blinking Battery OK No Light Battery Low T O U C H T R O N I C S, I N C. v © 2005 TouchTronics, Inc. All Rights Reserved. TouchTronics, the TouchTronics logo, and other TouchTronics marks are owned by TouchTronics and may be registered. TouchTronics assumes no responsibility for any errors that may appear in this manual. Information contained herein is subject to change without notice. FCC Compliance and Advisory Statement. This hardware device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) this device may not cause harmful interference, and 2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed or used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 1) reorient or relocate the receiving antenna; 2) increase the separation between the equipment and the receiver 3) connect the equipment to an outlet on a circuit different from that to which the receiver is connected; 4) consult the dealer or an experienced radio/TV technician for help. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Where shielded interface cables have been provided with the product or specified additional components or accessories elsewhere defined to be used with the installation of the product, they must be used in order to ensure compliance with FCC regulations. Canadian DOC Statement. This digital device does not exceed the Class B limits for radio noise emissions from digital apparatus specified in the interference-causing equipment standard entitled “Digital Apparatus,” ICES-003 of the Department of Communications. This device complies with RSS-310 of Industry Canada. Operation is subject to the following two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device. © 2005 TouchTronics, Inc. Tous droits réservés. TouchTronics, le logo TouchTronics et les autres marques TouchTronics sont la propriété exclusive de TouchTronics et sont susceptibles d’être des marques déposées. Toutes les autres marques sont la propriété exclusive de leurs détenteurs respectifs. TouchTronics décline toute responsabilité en cas d’erreurs dans ce manuel. Les informations énoncées dans le présent document peuvent faire l’objet de modifications sans avis préalable. Déclaration FCC. Cet équipement a été testé et déclaré conforme à la section 15 du règlement de la FCC. Son fonctionnement est soumis aux conditions suivantes: 1) l’équipement concerné ne doit pas causer d’interférences dangereuses, et 2) il doit accepter toute interférence reçue, y compris les interférences risquant d’engendrer un fonctionnement indésirable. Cet équipement a été testé et déclaré conforme aux limitations prévues dans le cadre de la catégorie B des appareils numériques défini par la section 15 du règlement de la FCC. Ces limitations sont stipulées aux fins de garantir une protection raisonnable contre les interférences gênantes en installation résidentielle. Cet équipement génère, utilise et diffuse des ondes radio, et s’il n’est pas installé ni utilisé en conformité avec les instructions dont il fait l’objet, peut causer des interférences gênantes avec les communications radio. Cependant, nous ne pouvons vous garantir qu’une interférence ne se produira pas dans une installation particulière. Si cet équipement produit des interférences graves lors de réceptions radio ou télévisées qui peuvent être détectées en allumant et en éteignant l’équipement, vous êtes invités à les supprimer de plusieurs manières: 1) Réorienter ou déplacer l’antenne de réception; 2) Augmenter la distance séparant l’équipement et le récepteur 3) Connecter l’équipement à un circuit différent de celui auquel le récepteur est connecté; 4) Contacter votre revendeur ou un technicien radio/TV qualifié. Toutes modifications ou tous changements effectués sans l’accord exprès de la partie responsable de la conformité aux normes pourraient contraindre l’utilisateur à ne plus utiliser son équipement. Afin d’assurer la…
Text truncated - open the document above for the full version.
FCC ID: IVS1000TF Request for Confidentiality In accordance with 47 C.F.R. Section 0.459, we, TOUCHTRONICS. INC., hereby request confidentiality for the block diagram, schematic and product description presented for certification. In support of the Request for Confidentiality, the following is stated: Enclosed within this application is technical information which we deem to be trade secrets and proprietary. If made public, the information might be used to our disadvantage. To assist in assuring that we receive the full value of our product and protect its competitive posture, we respectfully request this grant of confidentiality. Sincerely, Gordon L. Helm Technical Lab Manager Narte Certified Engineer, # EMC-002401-NE Tel. 269 313-2433 / Fax 269 429-9016 Email: [email protected]
Printed copies must be verified against electronic master before use. T ouch Tr onics , I nc ™ 57315 Nagy Drive www.touchtroni cs.com Phone: (574) 294-2570 Drawn By: D. Evans Date: 2005-12-15 Elkhart, IN 46517 touchtronics@touc htronics.com FAX: (574) 293-1611 Approved By: R. Mathia Date: 2005-12-20 Approved By: Date: Title: Label, PowerTouch 1000 Series Transmitters Size: B Drawing: LBL11404 Rev: A Proprietary Information These drawings and specifications are the property of TouchTronics, Inc. And shall not be reproduced, copied, disclosed to others, or used as the basis for the manufacture or sale of apparatus or devices without permission. Scale: None Filename: LBL11404_A.doc Sheet: 1 of 1 Label Size: 1” x 0.75” Label Stock: LBL10471-5 (white polyester) Ribbon Stock: LBL10472-3 (black) ECO #: Rev: Description: Drawn: Date: App’d: Date: --- A Initial release. DWE 2005-12-15 RCM 2005-12-20 LBL11404-10 1800-TIM-TW4 IVS1800TIMTW 6265A-18TIMTW Label, PowerTouch 1800-TIM-TW4 Transmitter LBL11404-9 1000-TX6S IVS1800EQLTX 6265A-18EQLTX Label, PowerTouch 1000-TX6S Transmitter LBL11404-8 1000-TX4S IVS1800EQLTX 6265A-18EQLTX Label, PowerTouch 1000-TX4S Transmitter LBL11404-7 1000-TX2S IVS1800EQLTX 6265A-18EQLTX Label, PowerTouch 1000-TX2S Transmitter LBL11404-6 1800-EQL-TX6S IVS1800EQLTX 6265A-18EQLTX Label, PowerTouch 1800-EQL-TX6S Transmitter LBL11404-5 1800-EQL-TX4S IVS1800EQLTX 6265A-18EQLTX Label, PowerTouch 1800-EQL-TX4S Transmitter LBL11404-4 1800-EQL-TX2S IVS1800EQLTX 6265A-18EQLTX Label, PowerTouch 1800-EQL-TX2S Transmitter LBL11404-3 1000-TF6 IVS1000TF 6265A-1000TF Label, PowerTouch 1000-TF6 Transmitter LBL11404-2 1000-TF4 IVS1000TF 6265A-1000TF Label, PowerTouch 1000-TF4 Transmitter LBL11404-1 1000-TF2 IVS1000TF 6265A-1000TF Label, PowerTouch 1000-TF2 Transmitter Part Number <Model> Field <FCC_ID#> Field <IC_ID#> Field Description Note : 1. Replace <Model>, <FCC_ID#>, and <IC_ID#> text fields on label with values shown in part number table.
Test report #0500814 FCC 15.231 for 1000-TF FCC ID: IVS1000TF Tested Sep 1, 2005 AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (269) 424-7014 EXmisc_RFexpose.doc Misc. EXHIBIT: Page 1 of 1 MISC. EXHIBIT: RF EXPOSURE INFORMATION [2.1093(C)] The manufacturer and applicant: TOUCHTRONICS. INC.. 57315 Nagy Drive Elkhart, IN 46517 Product: Weather sealed remote control unit with external switches. Model: PowerTouch 1000-TF Applicable Rules: 47CFR Part 15.231b Pursuant to 47CFR Part 1.1307(b), 47CFR Part 2.1091(c), and 47CFR Part 2.1093(c) this transmitting device, compliant to 47CFR Part 15.231b, is categorically excluded from evaluation regarding the Maximum Permissible Exposure of RF energy.
Test report #0500814 FCC 15.231 for 1000-TF FCC ID: IVS1000TF Tested Sept 1, 2005 AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (269) 424-7014 0500814.doc EXHIBIT E: Page 1 of 16 EXHIBIT E: REPORT OF MEASUREMENTS [2.1033(B6)] Test Report for FCC ID: IVS1000TF FCC Part 2.1031, Part 15 Subpart C(15.231b) Report #0500814 Issued 3/05/2006 433.92MH Z POWERTOUCH 1000-TF TRANSMITTER Prepared for: TOUCHTRONICS. INC.. 57315 Nagy Drive Elkhart, IN 46517 Test Date(s): Sept 1, 2005 Data recorded by Gordan L. Helm, NCE This report prepared by: Gordan L. Helm, NCE Technical Manager/Test Engineer, AHD Test report #0500814 FCC 15.231 for 1000-TF FCC ID: IVS1000TF Tested Sept 1, 2005 AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (269) 424-7014 0500814.doc EXHIBIT E: Page 2 of 16 TABLE OF CONTENTS EXHIBIT E: Report of Measurements [2.1033(b6)] .....................................................................................1 TABLE OF CONTENTS.........................................................................................................................2 Statements Concerning this Report.......................................................................................................3 Manufacturer/Applicant [2.1033(b1)] ....................................................................................................4 Measurement/Test Site Facility & Equipment........................................................................................4 Test Site [2.948, 2.1033(b6)] ........................................................................................................4 Measurement Equipment Used [2.947(d), 15.231(b)] ..................................................................4 Environment...........................................................................................................................................4 Summary of Results: .............................................................................................................................6 Changes made to achieve compliance..........................................................................................6 EUT Description ............................................................................................................................................7 EUT Pictures..........................................................................................................................................7 Tested Configuration /Setup: .................................................................................................................8 Support Equipment & Cabling .......................................................................................................8 Setup Diagram ...............................................................................................................................8 Standards Applied to Test: ..................................................................................................................10 Equipment Configuration .....................................................................................................................10 Test Methodology: ...............................................................................................................................10 FORMULAS AND SAMPLE CALCULATIONS: ...........................................................................12 Test Data .............................................................................................................................................13 Radiated Field Strength Measurements: [15.231(b), 15.205] ....................................................13 Occupied Bandwidth [15.231(c)]..................................................................................................13 Radiated Field Strength Measurements: [15.231(b), 15.205, 15.209)] ......................................14 Out of Band Emissions [15.231(b)]..............................................................................................15 Test report #0500814 FCC 15.231 for 1000-TF FCC ID: IVS1000TF Tested Sept 1, 2005 AHD EMC Lab, 92723 M152, Dowagiac, MI 49047, (269) 424-7014 0500814.doc EXHIBIT E: Page 3 of 16 Statements Concerning this Report NVLAP Accreditation: NVLAP Lab Code 200129-0 The scope of AHD accreditation is the conducted emissions, radiated emissions test methods of: IEC/CISPR 22: Limits and methods measurement of radio disturbance characteristics of information technology equipment. FCC Method – 47 CFT Part 15 – Digital Devices. AS/NZS 3548: Electromagnetic Interference – Limits and Methods of Measurement of Information Technology Equipment. IEC61000-4-2 and Amend.1: ElectroStatic Discharge Immunity IEC61000-4-5: Surge Immunity Test Data: This test report contains data covered by the NVLAP accreditation.. Test Traceability: The calibration of all measuring and test equipment and the measured data using this equipment are traceable to the National Institute for Standards and Technology (NIST). Limitations on results: The test results contained in this report relate only to the Item(s) tested. Any electrical or mechanical modification made to the test item subsequent to the test date shall invalidate the data presented in this report. Any electrical or mechanical modification made to the test item subsequent to this test date shall require an evaluation to verify continued compliance. Limitations on copying: This report shall not be reproduced, except in full, without the written approval of AHD. Limitations of the report: This report shall not be used to claim product endorsement by NVLAP, FCC, or any agency of the US Government. Statement of Test Results Uncertainty: Following the guidelines of NAMAS publication NIS81 and NIST Technical Note 1297, the Measurement Uncertainty at a 95% confidence level is determined to be: ± 1.4 dB Retention of Records: 1) For equipment verified to comply with FCC regulations, the manufact…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.92 MHz - 433.92 MHz | - |

Remote Control Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Security/Remote Control Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Keyless Entry RFID Reader
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Keyless Start RFID Reader
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Security/Remote Control Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter