Technical Document CB529A Program & Install Instructions 1 P/N 430721-00 Rev C CB529A CB529A Programming and Installation Instructions The CB529A is a special purpose, multi-function call box. It is designed for use as a director, shopper and/or external contact call box. The CB529A contains 4-inputs, each input can be configured for use as a normally opened or normally closed contact. The contacts can be configured individually or globally. The CB529A must be correctly configured and programmed to operate with external devices. Identify the quantity and types of circuits you will be using prior to beginning installation. Call Box Jumpers The CB529A requires +3VDC to operate. Power can be supplied via 2-C size batteries or an external +12VDC power supply. Using JP201, select the desired power source by placing the jumper over the two corresponding pins. Removing the jumper or placing it on one pin of JP201 will disable the call box. The CB529A has 4-inputs, each input has a jumper used to assign the circuit type, normally opened (NO) or normally closed (NC). Using the jumpers labeled, JP301- JP304, set the circuit type for each input. Placing a jumper over both pins on the right, or removing the jumper, assigns a normally opened input. Placing a jumper over both pins on the left assigns a normally closed input. (The picture at right indicates all inputs configured for normally opened inputs.) Call Box Programming The CB529A uses a hierarchy based menu structure. Programming requires a series of button presses to access each menu. Using button-1 to SET, button- A to RESET and the button-1 assurance LED, program the following menu options. Enter Programming Menu Press and hold the RESET button (approx. 8-sec) until the assurance LED blinks once. Press and hold the SET button (approx. 8-sec.) until the assurance LED blinks twice. Press and hold the RESET button (approx. 8-sec.) until the assurance LED blinks three times. Proceed to the desired menu. Menu-1: Address Programming -used to assign an alarm address to a call box. The address will define which message(s) are broadcast when the call box is activated. The valid address range is from 001 to 999. Leading zeros are required. The default alarm for all call boxes is alarm-001. (Example: Alarm-107) After entering the Programming Menu; Press the SET button once, RESET once. The assurance LED will flash once to confirm your entry. You are now in Menu-1. Enter your address as follows. Press the SET button once, RESET once to save. (1) Press the RESET button once to represent the zero. (0) Press the SET button seven times, RESET once to save. (7) PRE-RELEASE Technical Document CB529A Program & Install Instructions 2 P/N 430721-00 Rev C When the last digit is saved, the assurance LED will confirm your entry by flashing to indicate the digits entered. A zero is indicated by a long flash of approximately 1-second. Call box buttons-2-4 are automatically assigned the next consecutive alarm numbers. They cannot be programmed independently. Menu-3: Global Input Mode -used to assign operational characteristics to all inputs globally. The operational characteristics define how the call box will respond to button presses, input triggers and timing parameters. After entering the Programming Menu; Press the SETbutton 3-times, RESET once to save. The assurance LED will flash three times to confirm your entry. You are now in Menu-3. Press the SET button <1--6> times to select the Operating Mode, RESET once to save. The assurance LED will flash to confirm your entry. Menu-11: Individual Input Mode -used to assign operational characteristics to each input individually. The operational characteristics define how the call box will respond to button presses, input triggers and timing parameters. After entering the Programming Menu; Press the SETbutton 11- times, RESET once to save. The assurance LED will flash eleven times to confirm your entry. You are now in Menu-11. Press the SET button <1–4> times to select the input you are programming, RESET once to save. The assurance led will flash to confirm your entry. Press the SET button <1–4> times to select the Operating Mode, RESET once to save. The assurance LED will flash to confirm your input number, pause, then flash to confirm your Operating Mode entry. NOTE:Operating Modes <5--6> are NOT valid for Individual Input Mode. When Operating Modes <5--6> are set globally, Individual Input Mode is disabled. Operating Modes Mode-1: Alarm Notify Non-Latching Basic alarm notification; compatible with “Shopper Call Box” alarm processing. When any INPUT is activated, an alarm SET is broadcast and the corresponding LED will flash according to “LED Sequence 1”. (Indicated below.) When the INPUT is deactivated, an alarm RESET is broadcast and the corresponding LED will turn off. Mode-2: Alarm Notify Latching Basic alarm notification, response required; When any INPUT is activated, an alarm SET is broadcast and the corresponding LED will flash according to “LED Sequence 1”. (Indicated below.) When the INPUT is deactivated, NO alarm RESET is broadcast. The corresponding LED will continue to flash until the front panel button is pressed. Responding user must press the front panel button corresponding to the active INPUT to broadcast an alarm RESET and turn off the LED. If a front panel button is pressed when the INPUT is not active, (non-alarm), an alarm RESET is broadcast. PRE-RELEASE Technical Document CB529A Program & Install Instructions 3 P/N 430721-00 Rev C Mode-3: Alarm Reminder Non-Latching Same as Mode 1 except, the alarm is re-started if the INPUT is not cleared. Periodically re-starts the alarm sequence for situations in which a persisting alarm condition may be overlooked (such as an alarm sequence that starts during unstaffed hours and does not self-clear). If alarm state persists more than XXX minutes (XXX specified by CU-based variable in the range of 15 to 999 minutes; default is 30 minutes), then repeat…
Text truncated - open the document above for the full version.
June 1, 2011 Statement regarding FCC and IC label: The adhesive labels applied to the call box enclosures are considered permanent. We have selected a vinyl material for durability. After printing, overlaminate is applied to ensure the print does not fade, smudge, or wear. The selected adhesive is a semi- permanent acrylic with good plasticizer, UV and solvent resistance. The adhesive exhibits superior adhesive performance when applied to the plastic enclosure surface.
1.5 x 2 Inches, White Vinyl, Black Print Material: RF T -4911 Overlaminate: 1mil Clear Polypropylene, RL-TCC-UL2000 or QS800XC Adhesive: TS523 All materials and finishes shall comply with European Union restrictions of hazardous substances. (RoHS) Alternate materials must have RoHS compliance and be approved by Indyme. 1.500 2.000 Minimum Radius .050 For art detail reference Indyme control document EPS file: 220198-25_B CB529A FCC Label REVISIONS REV.DESCRIPTIONDATEAPPROVED ARelease for manufacture8/18/11Andrea B BAR842369/14/11Andrea B 63 μIN .X .XX .XXX ±.05 ±.025 ±.010 ± 0.5 º MFG APPR ENG APPR DRAWN APPROVALSDATE CHECKED COMMENTS INTERPRET GEOMETRIC TOL PER: ASME Y14.100 - 2000 White Vinyl RF T-4911 220198-25 B FILE NAME: 220198-25_B CB529A FCC Label Sheet 1 of 1 UNLESS OTHERWISE SPECIFIED DIMENSION TOLERANCES ARE DECIMAL: IN: ANGLES: FINISH MATERIAL A SCALE REV DWG NO. CAGE CODE SIZE THIS DOCUMENT IS THE PROPERTY OF INDYME AND IS CONSIDERED COMPANY CONFIDENTIAL. THE REPRODUCTION OR USE OF INFORMATION HEREIN, ALL OR IN PART, IS EXPRESSLY PROHIBITED WITHOUT WRITTEN CONFIRMATION FROM A PRINCIPAL MEMBER OF MANAGEMENT AT INDYME. 4:1 4:1 indyme Solutions Andrea Andrea G King Label FCC/IC CB529A 8/18/11 8/18/11 8/18/11
Report Number: D10720R1 FCC Part 15 Subpart C Section 15.231 Test Report Shopper Call Box - FCC ID: J69CB529A Model: CB529A Brea Division 114 Olinda Drive Brea, CA 92823 (714) 579-0500 Agoura Division 2337 Troutdale Drive Agoura, CA 91301 (818) 597-0600 Silverado Division 19121 El Toro Road Silverado, CA 92676 (949) 589-0700 Lake Forest Division 20621 Pascal Way Lake Forest, CA 92630 (949) 587-0400 Page 1 of 17 FCC PART 15, SUBPART B and SUBPART C TEST REPORT for SHOPPER CALL BOX MODEL: CB529A Prepared for INDYME SOLUTIONS, INC. 8295 AERO PLACE SAN DIEGO, CA 92123 Prepared by:_____________________ MATT HARRISON Approved by:____________________ JOSH HANSEN COMPATIBLE ELECTRONICS INC. 20621 Pascal Way LAKE FOREST, CA 92630 (949) 587-0400 DATE: APRIL 10, 2012 REPORT APPENDICES TOTAL BODY A B C D E PAGES 17 2 2 2 18 31 72 This report shall not be reproduced except in full, without the written approval of Compatible Electronics. Report Number: D10720R1 FCC Part 15 Subpart C Section 15.231 Test Report Shopper Call Box - FCC ID: J69CB529A Model: CB529A Brea Division 114 Olinda Drive Brea, CA 92823 (714) 579-0500 Agoura Division 2337 Troutdale Drive Agoura, CA 91301 (818) 597-0600 Silverado Division 19121 El Toro Road Silverado, CA 92676 (949) 589-0700 Lake Forest Division 20621 Pascal Way Lake Forest, CA 92630 (949) 587-0400 Page 2 of 17 TABLE OF CONTENTS Section / Title PAGE GENERAL REPORT SUMMARY 4 SUMMARY OF TEST RESULTS 5 1. PURPOSE 6 2. ADMINISTRATIVE DATA 7 2.1 Location of Testing 7 2.2 Traceability Statement 7 2.3 Cognizant Personnel 7 2.4 Date Test Sample was Received 7 2.5 Disposition of the Test Sample 7 2.6 Abbreviations and Acronyms 7 3. APPLICABLE DOCUMENTS 8 4. DESCRIPTION OF TEST CONFIGURATION 9 4.1 Description Of Test Configuration - EMI 9 4.1.1 Cable Construction and Termination 10 5. LISTS OF EUT, ACCESSORIES AND TEST EQUIPMENT 11 5.1 EUT and Accessory List 11 5.2 EMI Test Equipment 12 6. TEST SITE DESCRIPTION 13 6.1 Test Facility Description 13 6.2 EUT Mounting, Bonding and Grounding 13 7. TEST PROCEDURES 14 7.1 RF Emissions 14 7.1.1 Conducted Emissions Test 14 7.1.2 Radiated Emissions (Spurious and Harmonics) Test 15 7.1.3 Radiated Emissions (Spurious and Harmonics) Test (Continued) 16 7.1.4 Peak Radiated EMI 16 7.1.5 Bandwidth of the Fundamental 16 8. CONCLUSIONS 17 Report Number: D10720R1 FCC Part 15 Subpart C Section 15.231 Test Report Shopper Call Box - FCC ID: J69CB529A Model: CB529A Brea Division 114 Olinda Drive Brea, CA 92823 (714) 579-0500 Agoura Division 2337 Troutdale Drive Agoura, CA 91301 (818) 597-0600 Silverado Division 19121 El Toro Road Silverado, CA 92676 (949) 589-0700 Lake Forest Division 20621 Pascal Way Lake Forest, CA 92630 (949) 587-0400 Page 3 of 17 LIST OF APPENDICES APPENDIX TITLE A Laboratory Recognitions B Modifications to the EUT C Additional Models Covered Under This Report D Diagrams, Charts, and Photos Test Setup Diagrams Radiated Emissions Photos Antenna and Effective Gain Factors E Data Sheets LIST OF FIGURES FIGURE TITLE 1 Plot Map And Layout of 3 Meter Radiated Site 2 Radiated Emissions 3-Meter Semi-Anechoic Test Chamber Above 1 GHz 3 Conducted Emissions Test Setup Report Number: D10720R1 FCC Part 15 Subpart C Section 15.231 Test Report Shopper Call Box - FCC ID: J69CB529A Model: CB529A Brea Division 114 Olinda Drive Brea, CA 92823 (714) 579-0500 Agoura Division 2337 Troutdale Drive Agoura, CA 91301 (818) 597-0600 Silverado Division 19121 El Toro Road Silverado, CA 92676 (949) 589-0700 Lake Forest Division 20621 Pascal Way Lake Forest, CA 92630 (949) 587-0400 Page 4 of 17 GENERAL REPORT SUMMARY This electromagnetic emission test report is generated by Compatible Electronics Inc., which is an independent testing and consulting firm. The test report is based on testing performed by Compatible Electronics personnel according to the measurement procedures described in the test specifications given below and in the "Test Procedures" section of this report. The measurement data and conclusions appearing herein relate only to the sample tested and this report may not be reproduced without the written permission of Compatible Electronics, unless done so in full. This report must not be used to claim product endorsement by NVLAP, NIST or any other agency of the U.S. Government. Device Tested: Shopper Call Box Model: CB529A Product Description: See Expository Statement Modifications: The EUT was not modified during the testing. Manufacturer: Indyme Solutions, Inc. 8295 Aero Place San Diego, CA 92123 Test Date: March 20, 2012 Test Specifications: CFR Title 47, Part 15 Subpart B, Section 15.109 and Part 15 Subpart C, Sections 15.205, 15.207, 15.209 and 15.231 Test Procedure: ANSI C63.10: 2009 CFR 47, 15.231 Test Deviations: The test procedure was not deviated from during the testing. Report Number: D10720R1 FCC Part 15 Subpart C Section 15.231 Test Report Shopper Call Box - FCC ID: J69CB529A Model: CB529A Brea Division 114 Olinda Drive Brea, CA 92823 (714) 579-0500 Agoura Division 2337 Troutdale Drive Agoura, CA 91301 (818) 597-0600 Silverado Division 19121 El Toro Road Silverado, CA 92676 (949) 589-0700 Lake Forest Division 20621 Pascal Way Lake Forest, CA 92630 (949) 587-0400 Page 5 of 17 SUMMARY OF TEST RESULTS TEST DESCRIPTION RESULTS 1 Conducted RF Emissions , 150 kHz - 30 MHz Complies with the limits in CFR Title 47, FCC Part 15 Subpart C, section 15.207. 2 Radiated RF Emissions, 0.10 -30 MHz Complies with the limits of CFR Title 47, Part 15, Subpart C, sections 15.205 & 15.209 3 Radiated RF Emissions, 30 - 4000 MHz Complies with the limits of CFR Title 47, Part 15, Subpart B & C, sections 15.109, 15.205, & 15.209 4 -20 dB Occupied Bandwidth of the Emission Complies with the limits of CFR Title 47, Part 15, Subpart C, section 15.231 5 Peak Radiated EMI Complies with the limits of CFR Title 47, Part 15, Subpart C, section 15.231 Report Number: D10720R1 FCC Part 15 Subpart C Section 15.231 Test Report Shopper Call Box - FCC ID: J69CB529A Mo…
Text truncated - open the document above for the full version.
FCC ID: J69CB529A Configuration: Battery Powered FCC ID: J69CB529A Configuration: Power Supply
20621 Pascal Way · Lake Forest, California · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 303.825 MHz - 303.825 MHz | - |

Shopper Call Box
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Wireless Help Button
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Wireless Help Button
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Help Button
Equipment Class
DSS - Part 15 Spread Spectrum TransmitterCall Button
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter