FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Chamberlain Wireless Products Inc./
  3. JLFPTE1

JLFPTE1Push To Exit

Chamberlain Wireless Products Inc.
Push To Exit - FCC ID JLFPTE1 - Chamberlain Wireless Products Inc.
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Nov 26, 2007
Application Purpose
Original Equipment
Date of Application
Nov 25, 2007
Equipment Note
Push To Exit
Frequency Range
903.00000000 - 926.00000000
Company
Chamberlain Wireless Products Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Parts List/Tune Up Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

- 4 - Made With Pride In the USA. A manufacturer’s full One Year Warranty covers this product. - 1 - Oracle (TM) Push To Exit Thank you for purchasing one of the Oracle Push To Exit p roducts. This product has b een designed and manufactured in the USA, utilizing the highest qualit y standards available. One year limited WARRANTY International Electronics Inc. (IEI) warrants this product to be free of defects in materials and workmanship, for one year. For a period of ONE YEAR following purchase, IEI will repair or replace the product free of charge, including parts, labor, return shipping to you, and handling. After the initial one year of operation, the limited lifetime warranty will cover parts, labor, and return shipping to you, with a minimal handling charge specific to the product, as listed below: PUSH TO EXIT: $20.00 If you have installation or operation questions or are in need of warranty service, please contact our Product Support department by email at [email protected] or call 360- 254-1564 Tuesday-Friday 7-5 Pacific Time. If the issue is not resolvable, a manufacturer’s warranty repair order may be issued. To have the product(s) sent for warranty service. A Return Authorization number will be issued for warranty service, which must be put on the outside of the package, to be received and handled properly. Packages for warranty service may be sent to the following address. Packages with no RA# may not be accepted. IEI 5913C NE 127th AVE, Suite 800 Vancouver, WA 98682 Please include a note describing the problem that you are having and a copy of your original sales receipt (within the first year). If the warranty service is outside the first year, please include a check made out to IEI, based on the list of handling fees, shown above. Please note that you may need to send multiple units for warranty service, testing, and upgrading, though only the applicable fee for handling the failed unit(s) will be charged. Please allow 2-4 weeks for service and return shipping. If an EXPEDITED repair/replacement is requested, a 100% surcharge applies. In this case, please write EXPEDITED after the RA number. IEI will attempt to return expedited r epair orders within one week, except during holidays. All repairs or replacements are at the discretion of the Manufacturer. This warranty excludes items that have been abused, altered, incorrectly installed, or repaired by an unauthorized person. Changes or modifications not expressly approved by the Manufacturer could void the user’s authority to operate the equipment. The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment. This warranty is limited to the product only. No consequential damages are covered. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. International Electronics, Inc. FCC ID: JLFPTE2 Country Of Origin: USA • Completely Wireless • Algorithmically Secure • UV Hardened ABS Enclosure • Button Light When Motion Detected • Audible Confirmation • Pedestal or Surface Mount • Invisible to Lightning OPE2 Patents Pending 11/20/2007 DSW 1 DSW 2 OFF OFF ON OFF OFF ON ON ON Step 1 & 2 must occur within 5 seconds of each other. ACTIVATING A PUSH TO EXIT TO AN EXISTING MINIGAP NETWORK Step 1 & 2 must occur within 5 seconds of each other. - 3 - PUSH TO EXIT - 2 - CLEARING THE MEMORY ACTIVATING A PUSH TO EXIT TO A GCU Step 1 & 2 must occur within 5 seconds of each other. #3#4 USING THE PUSH TO EXIT GCU DIPSWITCH SETTINGS GCU #1 ACTIVATING A PUSH TO EXIT TO AN EXISTING GAP NETWORK Step 1 & 2 must occur within 5 seconds of each other. ACTIVATING A PUSH TO EXIT TO AN EXISTING KEYPAD NETWORK #2 The Push Is Exit is designed to be activated into an existing Gate Access Network. Install 4 ‘AA’ batteries into the Push To Exit. Lithium are preferred incold climates. 1. Press the LEARN button on a Push To Exit. 2. On the Gate Access Panel (GAP), Enter the Master Pin Number (for example): Followed by: The Push To Exit will respond with a beep indicating a successfulactivation. 1 2 3 4 0 5 NOTE: If the GCU has already been activated to a Gate Access Panel (GAP),Keypad, or MiniGAP, then the Push To Exit should also be activated to the GAP,Keypad, or MiniGAP 1. Press the LEARN button on the GCU. 2. Press the LEARN button on the Push To Exit. The Push To Exit will respond with a beep indicating a successful activation. The Push Is Exit is factory set to control GCU #1. Simply press the button to exit. Hold down the learn button until you hear the beep. 1. Press the LEARN button on the Push To Exit. 2. Press the LEARN button on the MiniGAP. The Push To Exit will respond with a beep indicating a successfulactivation. 1. Press the LEARN button on the Push To Exit. 2. Press the LEARN button on the Keypad. The Push To Exit will respond with a beep indicating a successfulactivation. OPE2 Patents Pending 11/20/2007

Cover Letter(s)

       USA Manufacturers Of Quality Consumer Electronics 5913 NE 127 th Ave, Suite 800, Vancouver WA 98682 August 28, 2005 Federal Communications Commission Authorization & Evaluation Division 7345 Oakland Mills Road Columbia, Maryland 21046 Gentlemen: This letter will authorize the appointment of M. FLOM ASSOCIATES, INC. to act as our Agent in all FCC matters. This appointment is affective until otherwise notified by us. This is to advise that we are in full compliance with the Anti-Drug Abuse Act. The Applicant is not subject to a denial of federal benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 USC 862, and no party to the application is subject to a denial of federal benefits pursuant to that section. International Electronics, Inc. Shary Nassimi, President

Cover Letter(s)

FCC ID: JLFPTE1 Request for Confidentiality In accordance with 47 C.F.R. Section 0.459, we, Chamberlain Group, Inc., hereby request confidentiality for the block diagram, schematic and product description presented for certification. In support of the Request for Confidentiality, the following is stated: Enclosed within this application is technical information which we deem to be trade secrets and proprietary. If made public, the information might be used to our disadvantage. To assist in assuring that we receive the full value of our product and protect its competitive posture, we respectfully request this grant of confidentiality. Barbara Kelkhoff Manager of Regulatory Affairs Chamberlain Group, Inc. 845 Larch Ave. Elmhurst, IL. 60126

ID Label/Location Info

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: JLFPTE1

Parts List/Tune Up Info

Push To Exit Active Devices Item Part Type Designator(s) Qty Mfg Function 1 MMBT2222 Q1,Q2,Q3 3 ST Micro NPN transistor 2 3.6864Mz Y1 1 Abracon crystal 3 ADF7020 U2 1 Analog 900mhz transceiver 4 ATMega8 IC2 1 Atmel Microcontroller 5 11.0592Mhz Y2 1 Abracon crystal 6 TPS76630D V1 1 TI 3.3V regulator 7 UPG2214 U1 1 CEL T/R switch 8 LPV324 IC9 1 National Quad Op-amp International Electronics, Inc. USA Manufacturers Of Quality Consumer Electronics 5913 NE 127th Ave, Suite 800, Vancouver WA 98682 Alignment Procedure FCCID JLFPTE1 PushToExit This device requires no tuning or alignment. Push To Exit Active Devices Item Part Type Designator(s) Qty Mfg Function 1 MMBT2222 Q1,Q2,Q3 3 ST Micro NPN transistor 2 3.6864Mz Y1 1 Abracon crystal 3 ADF7020 U2 1 Analog 900mhz transceiver 4 ATMega8 IC2 1 Atmel Microcontroller 5 11.0592Mhz Y2 1 Abracon crystal 6 TPS76630D V1 1 TI 3.3V regulator 7 UPG2214 U1 1 CEL T/R switch 8 LPV324 IC9 1 National Quad Op-amp International Electronics, Inc. USA Manufacturers Of Quality Consumer Electronics 5913 NE 127th Ave, Suite 800, Vancouver WA 98682 Alignment Procedure FCCID JLFPTE1 PushToExit This device requires no tuning or alignment.

Test Report

Flom Test Labs 3356 N. San Marcos Place, Suite 107 Chandler, Arizona 85225-7176 p0690002, d0780025 (866) 311-3268 phone, (480) 926-3598 fax Date: August 22, 2007 Federal Communications Commission Via: Electronic Filing Attention: Authorization & Evaluation Division Applicant: International Electronics Inc. Equipment: Push to Exit FCC ID: JLFPTE1 FCC Rules: 15.249 Gentlemen: On behalf of the Applicant, enclosed please find Application Form 731, Engineering Test Report and all pertinent documentation, the whole for approval of the referenced equipment as shown. We trust the same is in order. Should you need any further information, kindly contact the writer who is authorized to act as agent. Sincerely yours, Hoosamuddin S. Bandukwala, Lab Director enclosure(s) cc: Applicant HSB/mdw Flom Test Labs 3356 N. San Marcos Place, Suite 107 Chandler, Arizona 85225-7176 p0690002, d0780025 (866) 311-3268 phone, (480) 926-3598 fax List Of Exhibits (FCC Certification (Transmitters) - Revised 9/28/98) Applicant: International Electronics Inc. FCC ID: JLFPTE1 By Applicant: 1. Letter Of Authorization 2. Identification Drawings Id Label Location Info Attestation Statement(s) Location of Compliance Statement 3. Documentation: 2.1033(B) (3) User Manual(s) (4) Operational Description (5) Block Diagram (5) Schematic Diagram (7) External Photographs Internal Photographs Parts List Active Devices By F.T.L. Inc. A. Testimonial & Statement of Certification B. Statement of Qualifications Flom Test Labs 3356 N. San Marcos Place, Suite 107 Chandler, Arizona 85225-7176 p0690002, d0780025 (866) 311-3268 phone, (480) 926-3598 fax Transmitter Certification of FCC ID: JLFPTE1 Model: Push to Exit to Federal Communications Commission Rule Part(s) 15.249 Date Of Report: August 22, 2007 Date of Revised Report: November 15, 2007 On the Behalf of the Applicant: International Electronics Inc. 5913-C NE 127th Ave, Suite 800 Vancouver, WA 98682 Attention of: Shary Nassimi, President (360) 241-9090 email: [email protected] Supervised By: Hoosamuddin S. Bandukwala, Lab Director Flom Test Labs 3356 N. San Marcos Place, Suite 107 Chandler, Arizona 85225-7176 p0690002, d0780025 (866) 311-3268 phone, (480) 926-3598 fax The applicant has been cautioned as to the following: 15.21 Information to User. The users manual or instruction manual for an intentional radiator shall caution the user that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. 15.27(a) Special Accessories. Equipment marketed to a consumer must be capable of complying with the necessary regulations in the configuration in which the equipment is marketed. Where special accessories, such as shielded cables and/or special connectors are required to enable an unintentional or intentional radiator to comply with the emission limits in this part, the equipment must be marketed with, i.e. shipped and sold with, those special accessories. However, in lieu of shipping or packaging the special accessories with the unintentional or intentional radiator, the responsible party may employ other methods of ensuring that the special accessories are provided to the consumer, without additional charge. Information detailing any alternative method used to supply the special accessories for a grant of equipment authorization or retained in the verification records, as appropriate. The party responsible for the equipment, as detailed in § 2.909 of this chapter, shall ensure that these special accessories are provided with the equipment. The instruction manual for such devices shall include appropriate instructions on the first page of text concerned with the installation of the device that these special accessories must be used with the device. It is the responsibility of the user to use the needed special accessories supplied with the equipment. Flom Test Labs 3356 N. San Marcos Place, Suite 107 Chandler, Arizona 85225-7176 p0690002, d0780025 (866) 311-3268 phone, (480) 926-3598 fax Testimonial And Statement Of Certification This is to certify that: 1. That the application was prepared either by, or under the direct supervision of, the undersigned. 2. That the technical data supplied with the application was taken under my direction and supervision. 3. That the data was obtained on representative units, randomly selected. 4. That, to the best of my knowledge and belief, the facts set forth in the application and accompanying technical data are true and correct. Certifying Engineer: Hoosamuddin S. Bandukwala, Lab Director Flom Test Labs 3356 N. San Marcos Place, Suite 107 Chandler, Arizona 85225-7176 p0690002, d0780025 (866) 311-3268 phone, (480) 926-3598 fax Table Of Contents Rule Description Page Test Report 1 2.1033(c) General Information Required 2 . Standard Test Conditions and Engineering Practices 4 Test Results Summary 5 15.249. Field Strength of Fundamental 6 15.249(d) Field Strength of Harmonics 6 15.249(c), Radiated Spurious Emissions 8 . Test Equipment Utilized 11 Flom Test Labs 3356 N. San Marcos Place, Suite 107 Page 1 of 11 Chandler, Arizona 85225-7176 p0690002, d0780025 (866) 311-3268 phone, (480) 926-3598 fax Required information per ISO 17025-2005, paragraph 5.10: a) Test Report b) Laboratory: (FCC: 31040/SIT) (Canada: IC 2044) Flom Test Lab, Inc. 3356 N. San Marcos Place, Suite 107 Chandler, AZ 85225 c) Report Number: d0780025 d) Client: International Electronics Inc. e) Identification: Push to Exit Description: Transmitter f) EUT Condition: Not required unless specified in individual tests. g) Report Date: August 22, 2007 EUT Received: h, j, k): As indicated in individual tests. i) Sampling method: No sampling procedure used. l) Uncertainty: In accordance with FTL internal quality manual. m) Supervised by: Hoosamuddin S. Bandukwala, Lab Director n) Results: The results presented in this report relate only to the item tested. o) Reproduction: This report must not be reproduced, except…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Barbara Kelkhoff(Manager of Regulatory Affairs)
[email protected]630 993 6306Fax: 630 516 6863

Technical Contact

Flom Test LabHoosamuddin Bandukwala
[email protected]480-926-3100

3356 S. San Marcos Pl. · Chandler, Arizona · United States

Test Firm

Compliance Testing, LLCMichael Schafer
[email protected]480-926-3100Fax: 480 926 3598

Technical Specifications

#Rule PartsFrequency RangePower Output
115C903 MHz - 926 MHz-
Confidentiality
Long Term

Other Applications from Chamberlain Wireless Products Inc.

Remote Control Device - FCC ID JLFPIR1 - Chamberlain Wireless Products Inc.
JLFPIR1

Remote Control Device

Mar 31, 2008

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
3 Button Push to Exit - FCC ID JLFOPB2 - Chamberlain Wireless Products Inc.
JLFOPB2

3 Button Push to Exit

Mar 12, 2008

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Gate Access System - FCC ID JLFOMG1 - Chamberlain Wireless Products Inc.
JLFOMG1

Gate Access System

Mar 12, 2008

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Push to Exit - FCC ID JLFPTE2 - Chamberlain Wireless Products Inc.
JLFPTE2

Push to Exit

Mar 12, 2008

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Wireless Keypad Interface - FCC ID JLFKPD1 - Chamberlain Wireless Products Inc.
JLFKPD1

Wireless Keypad Interface

Jan 02, 2008

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter