FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Siemens AG/
  3. LYHMD720-3

LYHMD720-3GSM/GPRS Modem

Siemens AG
GSM/GPRS Modem - FCC ID LYHMD720-3 - Siemens AG
Click to zoom

Application Details

Equipment Class
PCB - PCS Licensed Transmitter
Date of Grant
Feb 06, 2006
Application Purpose
Original Equipment
Date of Application
Feb 06, 2006
Equipment Note
GSM/GPRS Modem
Frequency Range
824.20000000 - 848.80000000
Company
Siemens AG
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

Parts List/Tune Up Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Preface, Contents Introduction 1 Inserting the SIM card 2 Connecting the device and switching on the device 3 SINAUT MD720-3 in Terminal Mode 4 SINAUT MD720-3 in OPC Mode 5 Service function 6 Technical Data 7 Glossary SIMATIC NET GPRS/GSM-Modem SINAUT MD720-3 System manual C79000-G8976-C211 Edition 02/2006 2 Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. ! Danger indicates that death or severe personal injury will result if proper precautions are not taken. ! Warning indicates that death or severe personal injury may result if proper precautions are not taken. ! Caution with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. Caution without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. Notice indicates that an unintended result or situation can occur if the corresponding information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The device/system may only be set up and used in conjunction with this documentation. Commissioning and operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission, ground and label devices, systems and circuits in accordance with established safety practices and standards. Prescribed Usage Note the following: ! Warning This device may only be used for the applications described in the catalog or the technical description and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens. Correct, reliable operation of the product requires proper transport, storage, positioning and assembly as well as careful operation and maintenance. Trademarks All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Automation and Drives Postfach 48 48 90437 NÜRNBERG DEUTSCHLAND Order No.: C79000-G8976-C211 Edition 02/2006 Copyright © Siemens AG 2006 Technical data subject to change SINAUT MD720-3 C79000-G8976-C211 3 General The product SINAUT MD720-3 complies with European standard EN60950, 05.2003, Safety of Information Technology Equipment. Read the installation instructions carefully before using the device. Keep the device away from children, especially small children. The device must not be installed or operated outdoors or at damp locations. Do not operate the device if the connecting leads or the device itself are damaged. External power supply Use only an external power supply which also complies with EN60950. The output voltage of the external power supply must not exceed 30VDC. The output of the external power supply must be short-circuit proof. ! Warning The power supply unit to supply the SINAUT MD720-3 must comply with NEC Class 2 circuits as outlined in the National Electrical Code (ANSI/NFPA 70) only. When connecting to a battery or accumulator, make sure that an all-pole circuit- breaker (main battery switch) with sufficient selectivity and a fuse with sufficient selectivity are provided between the device and the battery or accumulator. Please pay regard to section 7 Technical Data of the system manual, as well as the installation and utilisation regulations of the respective manufacturers of the power supply, the battery or the accumulator. SIM card To install the SIM card the device must be opened. Before opening the device, disconnect it from the supply voltage. Static charges can damage the device when it is open. Discharge the electric static of your body before opening the device. To do so, touch an earthed surface, e.g. the metal casing of the switch cabinet. Please pay regard to section 2 Inserting the SIM card of this system manual. Handling cables Never pull a cable connector out of a socket by its cable, but pull on the connector itself. Cable connectors with screw fasteners (D-Sub) must always be screwed on tightly. Do not lay the cable over sharp corners and edges without edge protection. If necessary, provide sufficient strain relief for the cables. For safety reasons, make sure that the bending radius of the cables is observed. SINAUT MD720-3 4 C79000-G8976-C211 Failure to observe the bending radius of the antenna cable results in the deterioration of the system's transmission and reception properties. The minimum bending radius static must not fall below 5 times the cable diameter and dynamic below 15 times the cable diameter. Radio device ! Warning Never use the device in places where the operation of radio devices is prohibited. The device contains a radio transmitter which could in certain circumstances impair the functionality of electronic medical devices such as hearing aids or pacemakers. You can obtain advice from your physician or the manufacturer of such devices. To prevent data carriers from being demagnetised, do no…

Text truncated - open the document above for the full version.

External Photos

ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20511-9938-P-2224 Page 1 of 13 Appendix A. Pictures ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20511-9938-P-2224 Page 2 of 13 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20511-9938-P-2224 Page 3 of 13 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20511-9938-P-2224 Page 4 of 13 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20511-9938-P-2224 Page 5 of 13 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20511-9938-P-2224 Page 6 of 13

ID Label/Location Info

Version: Date: Written by: 1.0 5.2.2006 PAU Location FCC Label SIEMENS SINAUT MD720-3 By order of SIEMENS AG Doc.-No. : 3171PA010 SIEMENS_MD720-3_LabelLoc.doc Page 1/1

ID Label/Location Info

Version: Date: Written by: 1.0 5.2.2006 PAU FCC ID Label Sample SIEMENS SINAUT MD720-3 In order of SIEMENS AG Doc.-No. : 3171LB010 SIEMENS_MD720-3_LabelSmpl.doc Page 1/1 Th is de vi ce com pl ie s wi t h P a rt 15 of th e FCC Rul es . O pe rat i on i s su bje ct to the following two conditions: ( 1) this device may not cause harmful in te rfe re nce , an d (2 ) t hi s d evic e m ust acce pt any i n terf eren ce receiv e d, including inter fer ence that may cause undesired oper ation. FCC ID: LYHMD720-3

Internal Photos

ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20511-9938-P-2224 Page 7 of 13 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20511-9938-P-2224 Page 8 of 13 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20511-9938-P-2224 Page 9 of 13 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20511-9938-P-2224 Page 10 of 13

Parts List/Tune Up Info

Version: Date: Written by: 1.0 5.2.2006 PAU Tuning Procedure SIEMENS SINAUT MD720-3 By order of SIEMENS AG Doc.-No. : 3171PA011 3171PA010.doc Page 1/1 A tuning procedure is not applicable to the SIEMENS SINAUT MD720-3.

Test Report

ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH FCC - TEST - REPORT FCC RULES PARTS 22 and 24 FCC ID: LYHMD720-3 Test report no.: G0M20511-9938-P-2224 Certificate 1983-01 ELECTRONIC TECHNOLOGY SYSTEMS STORKOWER STRASSE 38C, D-15526 REICHENWALDE B. BERLIN DR. GENZ GMBH PHONE +49-33631-888 00 FAX +49-33631-888 660 ETS Dr. Genz GmbH, Germany Registration number: G0M20511-9938-P-2224 Page 1 of 41 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH TABLE OF CONTENTS 1 General information 1.1 Notes 1.2 Testing laboratory 1.3 Details of approval holder 1.4 Application details 1.5 Test item 1.6 Test standards 2 Technical test 2.1 Summary of test results 2.2 Test environment 2.3 Test equipment utilized 2.4 General Test Procedure 3 Test Results 4 RF Power Output, FCC 2.1046 4.1 Test Procedure 4.2 Test Results 5 Radiated Power FCC 22.913, FCC 24.232 5.1 Test Procedure 5.2 Test Results 6 Modulation Deviation Limiting, FCC 2.1047, 22.915(b)(c) 6.1 Test Procedure 6.2 Test Results 7 Audio Filter Characteristics, FCC 22.915(d) 7.1 Test Procedure 7.2 Test Results 8 Emission Limitations, , FCC 2.1049 8.1 Test Procedure 8.2 Test Results 9 Occupied Bandwidth FCC 22.917(b)(d); FCC 2.1049 9.1 Test Procedure 9.2 Test Results 10 Out of Band Emissions at Antenna Terminals, FCC 24.238(a) 10.1 Test Procedure 10.2 Test results ETS Dr. Genz GmbH, Germany Registration number: G0M20511-9938-P-2224 Page 2 of 41 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 11 Spurious Radiation, FCC 2.1053, 24.236 11.1 Test Procedure 11.2 Test Results 12 Line Conducted Emissions, FCC 15.207 12.1 Test Procedure 12.2 Test Results 13 Frequency Stability vs Temperature, FCC 2.1055, 22.355, 24. 235 13.1 Test Procedure 13.2 Test Equipment 14 Frequency Stability vs Voltage, FCC 2.1055, 22.355, 24.235 14.1 Test Procedure 14.2 Test Equipment ETS Dr. Genz GmbH, Germany Registration number: G0M20511-9938-P-2224 Page 3 of 41 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. The test results of this test report relate exclusively to the item tested as specified in 1.5. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH. Tester: 13.12.2005 M. Schostek Date ETS-Lab. Name Signature Technical responsibility for area of testing: 13.12.2005 N. Kaspar Date ETS Name Signature ETS Dr. Genz GmbH, Germany Registration number: G0M20511-9938-P-2224 Page 4 of 41 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.2 Testing laboratory 1.2.1 Location ELECTRONIC TECHNOLOGY SYSTEM DR. GENZ GMBH (ETS) Storkower Straße 38c D-15526 Reichenwalde b. Berlin Germany Telephone : +49 33631 888 00 Telefax : +49 33631 888 660 1.2.2 Details of accreditation status A CCREDITED TESTING LABORATORY DAR-REGISTRATION NUMBER: DAT-P-201/96 A CCREDITED COMPETENT BODY DAR-REGISTRATION NUMBER: BPT-ZE-026/96 FCC FILED TEST LABORATORY REG. NO. 96970 BLUETOOTH QUALIFICATION TEST FACILITY (BQTF) ACCREDITED BY: BLUETOOTH QUALIFICATION REVIEW BOARD (BQRF) I NDUSTRY CANADA FILED TEST LABORATORY REG. NO. IC 3470 A2LA ACCREDITED Certificate Number: 1983-01 1.3 Details of approval holder Name : Siemens AG Street : Gleiwitzer Str. 555 Town : 90475 Nürnberg Country : Germany Telephone : +49 911/ 895-5297 Fax : +49 911/ 895-155297 Contact : Herr Dietmar Herian E-Mail : [email protected] ETS Dr. Genz GmbH, Germany Registration number: G0M20511-9938-P-2224 Page 5 of 41 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.4 Application details Date of receipt of application : 10.11.2005 Date of receipt of test item : 10.11.2005 Date of test : 16.11.2005 - 07.12.2005 1.5 Test item Description of test item : GPRS/GSM Modem Type identification : Sinaut MD720-3 Serial number : Test model without serial number. Photos : See annex A. Technical data Frequency range Tx – GSM 850 : 824.2 – 848.80 MHz Frequency range Tx – PCS : 1850.2 – 1909.8 MHz Frequency range Rx - GSM 850 : 869.2 – 893.8 MHz Frequency range Rx - PCS : 1930.2 – 1989.8 MHz Antenna transmitter : fixed antenna Antenna connector : SMA (m)-Plug Antenna Gain : 0 dBi Power supply : 24 V DC Operating mode : duplex Type of modulation : GMSK (GSM modulation) Emission : GXW Manufacturer: (if applicable) Name : Street : Town : Country : ETS Dr. Genz GmbH, Germany Registration number: G0M20511-9938-P-2224 Page 6 of 41 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.6 Test standards Technical standard : FCC Parts 22, 24, 2, 15 Additional information : Because of using the GSM 850 as an alternative technology in 850 MHz band, not all test cases of FCC Part 22 are required. This device contains 900 MHz GSM and 1800 MHz DCS functions that are not operational in U.S. Territories. 2 Technical test 2.1 Summary of test results No deviations from the technical specification(s) were ascertained in the course : of the tests performed. or The deviations as specified in 2.5 were ascertained in the course of the tests … performed. 2.2 Test environment Temperature : 25 o C Relative humidity content : 20 ... 75 % Air pressure : 86 ... 103 kPa ETS Dr. Genz GmbH, Germany Registration number: G0M20511-9938-P-2224 Page 7 of 41 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 2.3 Test equipment ut…

Text truncated - open the document above for the full version.

Test Setup Photos

ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20511-9938-P-2224 Page 11 of 13 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20511-9938-P-2224 Page 12 of 13 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20511-9938-P-2224 Page 13 of 13

Contact Information

Applicant

Malgorzata Janson(Dr.)
[email protected]+4972166720125Fax: +4972166720125

Test Firm

Eurofins Product Service GmbHRobert Kschiwan-Kaspar
[email protected]49-33631-888-000Fax: 49-33631-888-660

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
222H824.2 MHz - 848.8 MHz2.09 W255KGXW44 Hz
Confidentiality
Long Term
Grant Notes
Power output listed is conducted for Part 22(GSM) and Part 24(PCS). The antenna installation and operating configurations of this transmitter, including antenna gain and cable loss must satisfy MPE categorical exclusion Requirements of �2.1091. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The antenna(s) used for this transmitter must not exceed a gain of 0dBi. This device contains 900/1800 MHz GSM functions that are not subject to this FCC filing. This filing is only applicable for PCS 1900 MHz and GSM 850 operations.

Other Applications from Siemens AG

LYHMRM85633M

SCALANCE MRM85633M

Aug 04, 2026

Equipment Class

CBD - Citizens Band Category A and B Devices
Vibration and temperature sensor - FCC ID LYH-MS200 - Siemens AG
LYH-MS200

Vibration and temperature sensor

May 10, 2023

Equipment Class

DTS - Digital Transmission System
MSAX-W1-RJ-E2 / MSAX-W1-RJ-E2-NO - FCC ID LYHMSAXV1 - Siemens AG
LYHMSAXV1

MSAX-W1-RJ-E2 / MSAX-W1-RJ-E2-NO

Apr 13, 2023

Equipment Class

JBP - Part 15 Class B Computing Device Peripheral
Industrial Wireless LAN Access Point Module - FCC ID LYHRAPACV1 - Siemens AG
LYHRAPACV1

Industrial Wireless LAN Access Point Module

Feb 20, 2020

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Industrial WLAN Access Point - FCC ID LYHELN1V1 - Siemens AG
LYHELN1V1

Industrial WLAN Access Point

Mar 31, 2014

Equipment Class

NII - Unlicensed National Information Infrastructure TX