Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
PRECISION INDUSTRIAL CO., LTD NO.192 Shun-Reen Rd. Wu-Fong Taichung Taiwan TEL:886-4-3391802 FAX:886-4-3304924 MESSERS: Max Light Technology Co.,LtdDATE: 06/01/1999 POWER OF ATTORNEY SUBJECT: FCC APPLICATION We, the undersigned, hereby authorize Max Light Technology Co.,Ltd. To act on our behalf in all matters relating to application for equipment authorization of our model: RL101 & RT111 including the signing of all documents relating to these matters. Any and all acts carried out by Max Light Technology Co.,Ltd. On our behalf shall have the same effect as acts of our own. Applicant: FEGO PRECISION INDUSTRIAL CO., LTD. By: BRUCE CHANG Signature Printed Title: DIRECTOR
MAX LIGHT Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab MAX LIGHT Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab MAX LIGHT Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab MAX LIGHT Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab
MAX LIGHT Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab Label Format: Label Position: This device complies with Part15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,and (2) This device must accept any interference received ,including. Interference that may cause undesired operation. Model: RL101 FCC ID: M8CRL101 MADE IN TAIWAN Equipment Lable 3CMX2CM Rear View
1234 A B C D 4321 D C B A 0 FEGO PRECISION INDUSTRIAL CO.,LTD NO.947 LIN SEN RD.,WU FONG SHANG TAICHUNG HSIEN, TAWIWAN TEL : 00886-4-3391802 FAX : 00886-4-3399374 0 2 7-Feb-1999 17:02:40D:\Client98\Sch\Bc3003a.sch Title Size:Number: Date:File: Revision: SheetofTime: A4 TP06 EF0 59 TEST 58 ROSC 57 RESET 56 CD3 55 CD2 54 CD1 53 CD0 52 X32O 51 X32I 50 VDD 49 AUD 48 CUP2 47 EF2 1 EF3 2 EF4 3 EF5 4 AB0 5 AB1 6 SEG31 7 SEG30 8 SEG29 9 SEG28 10 SEG27 11 SEG26 12 SEG25 13 SEG24 14 SEG23 15 SEG22 16 SEG21 17 SEG20 18 SEG18 20 SEG17 21 SEG14 24 SEG13 25 SEG12 26 SEG19 19 SEG11 27 SEG10 28 SEG9 29 SEG8 30 SEG7 31 SEG6 32 SEG5 33 SEG4 34 SEG3 35 SEG2 36 SEG1 37 SEG0 38 COM3 39 COM2 40 COM1 41 COM0 42 VSS 43 VDD1 44 VDD2 45 SEG16 22 SEG15 23 CUP1 46 EF1 60 U1 SPL10A C2 13 C1 12 C0 11 S8 10 S7 9 S6 8 S5 7 S4 6 S3 5 S2 4 S1 3 S0 2 NC 1 LCD1 WK-TZ9040-RG C2 104 CODE VCC R3 20K Y1 32K C3 15P C415P 1 2 3 45 6 7 8 SW1 SW-DIP4 D6 4148 D5 4148 D4 4148 D3 4148 LOBAT 12 J4 JUMPER R2 56K VCC RESET D7 4148 D2 4148 D1 4148 SKY1 FAN SPD SKY2 LT ON/OFF SKY3 DIMER SKY4 FAN ON/OFF EF0 EF0 1 2 J2 JUMPER 1 2 J3 JUMPER R1 150K C1 104 RESET VCC 1:Light On/Off1:Light dimmer 1:RF 0:IR 0:Nonreverst 1:Reverse IN 1 GND 2 OUT 3 U2 HT7070A9V R4 20K VCC LOBAT IN 1 GND 2 OUT 3 U3HT1034 C5 104 + C6 100uF/16V 9VVCC N1N2N3N4N5N6N7N8N9 N10 N11N12 N13 N14 N15 N16 N17 N18 N19 N20 N21 N22 N23 N24 N25 N26 N27 N28 N29 N30 N31 N32 BC3003 1 2 J1 SKY1 SKY2SKY3 SKY4 Q1 MPSH-10 R6 330 CODE R5 39K 9V C7 3P C9 1P C8 4P L1 IuH ANT
1234 A B C D 4321 D C B A 0 FEGO PRECISION INDUSTRIAL CO.,LTD NO.947 LIN SEN RD.,WU FONG SHANG TAICHUNG HSIEN, TAWIWAN TEL : 00886-4-3391802 FAX : 00886-4-3399374 0 2 7-Feb-1999 17:02:40D:\Client98\Sch\Bc3003a.sch Title Size:Number: Date:File: Revision: SheetofTime: A4 TP06 EF0 59 TEST 58 ROSC 57 RESET 56 CD3 55 CD2 54 CD1 53 CD0 52 X32O 51 X32I 50 VDD 49 AUD 48 CUP2 47 EF2 1 EF3 2 EF4 3 EF5 4 AB0 5 AB1 6 SEG31 7 SEG30 8 SEG29 9 SEG28 10 SEG27 11 SEG26 12 SEG25 13 SEG24 14 SEG23 15 SEG22 16 SEG21 17 SEG20 18 SEG18 20 SEG17 21 SEG14 24 SEG13 25 SEG12 26 SEG19 19 SEG11 27 SEG10 28 SEG9 29 SEG8 30 SEG7 31 SEG6 32 SEG5 33 SEG4 34 SEG3 35 SEG2 36 SEG1 37 SEG0 38 COM3 39 COM2 40 COM1 41 COM0 42 VSS 43 VDD1 44 VDD2 45 SEG16 22 SEG15 23 CUP1 46 EF1 60 U1 SPL10A C2 13 C1 12 C0 11 S8 10 S7 9 S6 8 S5 7 S4 6 S3 5 S2 4 S1 3 S0 2 NC 1 LCD1 WK-TZ9040-RG C2 104 CODE VCC R3 20K Y1 32K C3 15P C415P 1 2 3 45 6 7 8 SW1 SW-DIP4 D6 4148 D5 4148 D4 4148 D3 4148 LOBAT 12 J4 JUMPER R2 56K VCC RESET D7 4148 D2 4148 D1 4148 SKY1 FAN SPD SKY2 LT ON/OFF SKY3 DIMER SKY4 FAN ON/OFF EF0 EF0 1 2 J2 JUMPER 1 2 J3 JUMPER R1 150K C1 104 RESET VCC 1:Light On/Off1:Light dimmer 1:RF 0:IR 0:Nonreverst 1:Reverse IN 1 GND 2 OUT 3 U2 HT7070A9V R4 20K VCC LOBAT IN 1 GND 2 OUT 3 U3HT1034 C5 104 + C6 100uF/16V 9VVCC N1N2N3N4N5N6N7N8N9 N10 N11N12 N13 N14 N15 N16 N17 N18 N19 N20 N21 N22 N23 N24 N25 N26 N27 N28 N29 N30 N31 N32 BC3003 1 2 J1 SKY1 SKY2SKY3 SKY4 Q1 MPSH-10 R6 330 CODE R5 39K 9V C7 3P C9 1P C8 4P L1 IuH ANT
Product : REMOTE CONTROL TRANSMITTER Manufacture : FEGO PRECISION INDUSTRIAL CO., LTD. FCC ID : M8CRL101 Model : RL101 Report No. : MLT9905P15006 Test Date : JUNE.04.1999 Test By Max Light Technology Co.,Ltd. Room 5, 8F, No.125, Section 3 Roosevelt Road, Taipei, Taiwan., R.O.C. Tel: 886-2-363-2447 Fax: 886-2-363-2597 MAX LIGHT MEASUREMENT REPORT Page: 2/20 Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab Table of Contents : I. General 4. II. Conducted Emissions Requirements 6. III. Radiated Emissions Requirements 7. IV.Transmitter Bandwidth Measurements 13. V. Transmitter Duty Cycle Measurements 15. Appendix I (EUT Test Setup) 17. MAX LIGHT MEASUREMENT REPORT Page: 3/20 Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab CERTIFICATION We here by verify that : The test data, data evaluation, test procedures and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.4-1992. All test were conducted by MLT (Max Light Technology Co.,Ltd) Room 5, 8F, No.125, Section 3 Roosevelt Road, Taipei, Taiwan, R.O.C Also, we attest to the accuracy of each. We further submit that the energy emitted by the sample EUT tested as described in the report is in compliance with radiated emission limit of FCC Rules Part 15 Subpart C Section 15.231. EUT: REMOTE CONTROL TRANSMITTER Applicant: FEGO PRECISION INDUSTRIAL CO., LTD. NO. 947 LIN-SEN RD., WU FONG SHIANG, TAICHUNG HSIEN, TAIWAN Manufacturer: FEGO PRECISION INDUSTRIAL CO., LTD. NO. 947 LIN-SEN RD., WU FONG SHIANG, TAICHUNG HSIEN, TAIWAN Model No: RL101 FCC ID: M8CRL101 Prepared by : Approved by : Country Huang Roger Chen MAX LIGHT MEASUREMENT REPORT Page: 4/20 Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab I. GENERAL 1.1 Introduction The following measurement report is submitted on behalf of Fego Precision Industrial Co., Ltd. In support of an Intentional Periodic Radiator certification in accordance with Part 2 Subpart J and Part 15 Subpart A And C of the Commissionβs and Regulations. 1.2 Description of EUT EUT: REMOTE CONTROL TRANSMITTER Applicant: FEGO PRECISION INDUSTRIAL CO., LTD. NO. 947 LIN-SEN RD., WU FONG SHIANG, TAICHUNG HSIEN, TAIWAN Manufacturer: FEGO PRECISION INDUSTRIAL CO., LTD. NO. 947 LIN-SEN RD., WU FONG SHIANG, TAICHUNG HSIEN, TAIWAN Model No: RL101 FCC ID : M8CRL101 Power Type: Powered by DC 9V Battery The EUT(RL101) is Remote Control of Lamp/Fan Controller. The operation frequency is 314.681Mhz.Press the button on remote transmitter, can set the ON/OFF(FAN) / SPEED(FAN) / ON/OFF(LIGHT) / DIMMER(LIGHT) button. MAX LIGHT MEASUREMENT REPORT Page: 5/20 Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab 1.3 Description of Support Equipment The EUT itself forms a system. No support equipment is required for its normal operation. 1.4 Configuration of System Under Test 1.5 Test Procedure All measurements contained in this report were performed according to the techniques described in Measurement procedure ANSI C63.4-1992 "Measurement of Intentional Radiators." EUT MAX LIGHT MEASUREMENT REPORT Page: 6/20 Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab 1.6 General Test Condition The conditions under which the EUT operates were varied to determine their effect on the equipment's emission characteristics. The final configuration of the test system and the mode of operation used during these tests was chosen as that which produced the highest emission levels. However, only those conditions which the EUT was considered likely to encounter in normal use were investigated. MAX LIGHT MEASUREMENT REPORT Page: 7/20 Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab II. Conducted Emissions Requirements The EUT operates solely by the battery. According to the rule of Section 15.207(c), the EUT exempt to the power line conducted test. MAX LIGHT MEASUREMENT REPORT Page: 8/20 Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab III. Radiated Emissions Requirements 3.1 General Configuration: Prior to open-field testing, the EUT was placed in a shielded enclosure and scanned at a close distance to determine its emission characteristics. The physical arrangement of the EUT was varied (within the scope of arrangements likely to be encountered in actual use) to determine the effect on the unit's emanations in amplitude, directivity, and frequency. The exact system configuration which produced the highest emissions was noted so it could be reproduced later during the open-field tests. This was done to ensure that the final measurements would demonstrate the worst-case interference potential of the EUT. 3.2 General Configuration: Final radiation measurements were made on a three-meter, open- field test site. The EUT system was placed on a nonconductive turntable which is 0.8 meters height, top surface 1.0 x 1.5 meter. The spectrum was examined from 250 MHz to 4 GHz in order to cover the whole spectrum below10th harmonic which could generate from the EUT. During the test,EUT was set to transmit continuously and the switch was positioned to yield the maximum duty cycle which had measured before radiated emissions test. A nonconductive material surrounded the EUT to supporting the EUT for standing on tree orthogonal planes. At each condition, the EUT was rotated 360 degrees, and the antenna was raised and lowered from one to four meters to find the maximum emission levels. Measurements were taken using both horizontal and vertical antenna polarization. The field strength below 1 GHz was measured by EMCO Biconilog Antenna (mode 3142) at 3 Meter and the EMCO Double Ridged Guide Antenna (model 3115) was used in frequencies 1 β 4 GHz at a distance of I meter. All test results were extrapolated to equivalent signal at 3 meters utilizing an inverse linear distance extrapolation Factor (20dB/decade). MAX LIGHT MEASUREMENT REPORT Page: 9/20 Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab Appropriate preamplifiers were used for improving sβ¦
Text truncated - open the document above for the full version.
P.O.Box 5-86,Shen Keng Β· Taipei Hsien Β· Taiwan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 314.68 MHz - 314.68 MHz | - |

Remote control transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote control transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote Controller
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Remote Controller
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Transmitter
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter