M8CRT111Remote Controller

Fego Precision Industrial Co Ltd
Remote Controller - FCC ID M8CRT111 - Fego Precision Industrial Co Ltd
Click to zoom

Application Details

Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Date of Grant
Aug 23, 1999
Application Purpose
Original Equipment
Date of Application
Jun 13, 1999
Equipment Note
Remote Controller
Frequency Range
314.68000000 - 314.68000000
Company
Fego Precision Industrial Co Ltd
Country
Taiwan

Documents & Files

Select a file to view

Users Manual

β†—
β†—
β†—
β†—

Block Diagram

β†—
β†—
β†—

Cover Letter(s)

β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—
β†—

Schematics

β†—
β†—
β†—

Test Report

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

PRECISION INDUSTRIAL CO., LTD NO.192 Shun-Reen Rd. Wu-Fong Taichung Taiwan TEL:886-4-3391802 FAX:886-4-3304924 MESSERS: Max Light Technology Co.,LtdDATE: 06/01/1999 POWER OF ATTORNEY SUBJECT: FCC APPLICATION We, the undersigned, hereby authorize Max Light Technology Co.,Ltd. To act on our behalf in all matters relating to application for equipment authorization of our model: RL101 & RT111 including the signing of all documents relating to these matters. Any and all acts carried out by Max Light Technology Co.,Ltd. On our behalf shall have the same effect as acts of our own. Applicant: FEGO PRECISION INDUSTRIAL CO., LTD. By: BRUCE CHANG Signature Printed Title: DIRECTOR

Cover Letter(s)

PRECISION INDUSTRIAL CO., LTD NO.192 Shun-Reen Rd. Wu-Fong Taichung Taiwan TEL:886-4-3391802 FAX:886-4-3304924 MESSERS: Max Light Technology Co.,LtdDATE: 06/01/1999 POWER OF ATTORNEY SUBJECT: FCC APPLICATION We, the undersigned, hereby authorize Max Light Technology Co.,Ltd. To act on our behalf in all matters relating to application for equipment authorization of our model: RL101 & RT111 including the signing of all documents relating to these matters. Any and all acts carried out by Max Light Technology Co.,Ltd. On our behalf shall have the same effect as acts of our own. Applicant: FEGO PRECISION INDUSTRIAL CO., LTD. By: BRUCE CHANG Signature Printed Title: DIRECTOR

External Photos

MAX LIGHT Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab MAX LIGHT Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab MAX LIGHT Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab MAX LIGHT Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab

ID Label/Location Info

MAX LIGHT Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab Label Format: Label Position: This device complies with Part15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,and (2) This device must accept any interference received ,including. Interference that may cause undesired operation. Model: RL101 FCC ID: M8CRL101 MADE IN TAIWAN Equipment Lable 3CMX2CM Rear View

ID Label/Location Info

MAX LIGHT Report Number: MLT9905P15002 FCC ID: M8CRT111 Technology Lab Label Format: Label Position: This device complies with Part15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,and (2) This device must accept any interference received ,including. Interference that may cause undesired operation. Model: RT111 FCC ID: M8CRT111 MADE IN TAIWAN Equipment Lable 3CMX2CM Rear View

Test Report

Product : REMOTE CONTROL TRANSMITTER Manufacture : FEGO PRECISION INDUSTRIAL CO., LTD. FCC ID : M8CRL101 Model : RL101 Report No. : MLT9905P15006 Test Date : JUNE.04.1999 Test By Max Light Technology Co.,Ltd. Room 5, 8F, No.125, Section 3 Roosevelt Road, Taipei, Taiwan., R.O.C. Tel: 886-2-363-2447 Fax: 886-2-363-2597 MAX LIGHT MEASUREMENT REPORT Page: 2/20 Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab Table of Contents : I. General 4. II. Conducted Emissions Requirements 6. III. Radiated Emissions Requirements 7. IV.Transmitter Bandwidth Measurements 13. V. Transmitter Duty Cycle Measurements 15. Appendix I (EUT Test Setup) 17. MAX LIGHT MEASUREMENT REPORT Page: 3/20 Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab CERTIFICATION We here by verify that : The test data, data evaluation, test procedures and equipment configurations shown in this report were made in accordance with the procedures given in ANSI C63.4-1992. All test were conducted by MLT (Max Light Technology Co.,Ltd) Room 5, 8F, No.125, Section 3 Roosevelt Road, Taipei, Taiwan, R.O.C Also, we attest to the accuracy of each. We further submit that the energy emitted by the sample EUT tested as described in the report is in compliance with radiated emission limit of FCC Rules Part 15 Subpart C Section 15.231. EUT: REMOTE CONTROL TRANSMITTER Applicant: FEGO PRECISION INDUSTRIAL CO., LTD. NO. 947 LIN-SEN RD., WU FONG SHIANG, TAICHUNG HSIEN, TAIWAN Manufacturer: FEGO PRECISION INDUSTRIAL CO., LTD. NO. 947 LIN-SEN RD., WU FONG SHIANG, TAICHUNG HSIEN, TAIWAN Model No: RL101 FCC ID: M8CRL101 Prepared by : Approved by : Country Huang Roger Chen MAX LIGHT MEASUREMENT REPORT Page: 4/20 Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab I. GENERAL 1.1 Introduction The following measurement report is submitted on behalf of Fego Precision Industrial Co., Ltd. In support of an Intentional Periodic Radiator certification in accordance with Part 2 Subpart J and Part 15 Subpart A And C of the Commission’s and Regulations. 1.2 Description of EUT EUT: REMOTE CONTROL TRANSMITTER Applicant: FEGO PRECISION INDUSTRIAL CO., LTD. NO. 947 LIN-SEN RD., WU FONG SHIANG, TAICHUNG HSIEN, TAIWAN Manufacturer: FEGO PRECISION INDUSTRIAL CO., LTD. NO. 947 LIN-SEN RD., WU FONG SHIANG, TAICHUNG HSIEN, TAIWAN Model No: RL101 FCC ID : M8CRL101 Power Type: Powered by DC 9V Battery The EUT(RL101) is Remote Control of Lamp/Fan Controller. The operation frequency is 314.681Mhz.Press the button on remote transmitter, can set the ON/OFF(FAN) / SPEED(FAN) / ON/OFF(LIGHT) / DIMMER(LIGHT) button. MAX LIGHT MEASUREMENT REPORT Page: 5/20 Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab 1.3 Description of Support Equipment The EUT itself forms a system. No support equipment is required for its normal operation. 1.4 Configuration of System Under Test 1.5 Test Procedure All measurements contained in this report were performed according to the techniques described in Measurement procedure ANSI C63.4-1992 "Measurement of Intentional Radiators." EUT MAX LIGHT MEASUREMENT REPORT Page: 6/20 Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab 1.6 General Test Condition The conditions under which the EUT operates were varied to determine their effect on the equipment's emission characteristics. The final configuration of the test system and the mode of operation used during these tests was chosen as that which produced the highest emission levels. However, only those conditions which the EUT was considered likely to encounter in normal use were investigated. MAX LIGHT MEASUREMENT REPORT Page: 7/20 Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab II. Conducted Emissions Requirements The EUT operates solely by the battery. According to the rule of Section 15.207(c), the EUT exempt to the power line conducted test. MAX LIGHT MEASUREMENT REPORT Page: 8/20 Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab III. Radiated Emissions Requirements 3.1 General Configuration: Prior to open-field testing, the EUT was placed in a shielded enclosure and scanned at a close distance to determine its emission characteristics. The physical arrangement of the EUT was varied (within the scope of arrangements likely to be encountered in actual use) to determine the effect on the unit's emanations in amplitude, directivity, and frequency. The exact system configuration which produced the highest emissions was noted so it could be reproduced later during the open-field tests. This was done to ensure that the final measurements would demonstrate the worst-case interference potential of the EUT. 3.2 General Configuration: Final radiation measurements were made on a three-meter, open- field test site. The EUT system was placed on a nonconductive turntable which is 0.8 meters height, top surface 1.0 x 1.5 meter. The spectrum was examined from 250 MHz to 4 GHz in order to cover the whole spectrum below10th harmonic which could generate from the EUT. During the test,EUT was set to transmit continuously and the switch was positioned to yield the maximum duty cycle which had measured before radiated emissions test. A nonconductive material surrounded the EUT to supporting the EUT for standing on tree orthogonal planes. At each condition, the EUT was rotated 360 degrees, and the antenna was raised and lowered from one to four meters to find the maximum emission levels. Measurements were taken using both horizontal and vertical antenna polarization. The field strength below 1 GHz was measured by EMCO Biconilog Antenna (mode 3142) at 3 Meter and the EMCO Double Ridged Guide Antenna (model 3115) was used in frequencies 1 – 4 GHz at a distance of I meter. All test results were extrapolated to equivalent signal at 3 meters utilizing an inverse linear distance extrapolation Factor (20dB/decade). MAX LIGHT MEASUREMENT REPORT Page: 9/20 Report Number: MLT9905P15006 FCC ID: M8CRL101 Technology Lab Appropriate preamplifiers were used for improving s…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Bruce Chang(Director)
886 4 339-1802Fax: 886 4 330-4924

Technical Contact

Max Light Technology Co.,LtdCountry Huang
[email protected]886-2-26633486

P.O.Box 5-86,Shen Keng Β· Taipei Hsien Β· Taiwan

Non-Technical Contact

Max Light Technology Co.,LtdCountry Huang
[email protected]886-2-26633486

Technical Specifications

#Rule PartsFrequency RangePower Output
115C314.68 MHz - 314.68 MHz-

Other Applications from Fego Precision Industrial Co Ltd

Remote control transmitter - FCC ID M8C-EEC118RF433 - Fego Precision Industrial Co Ltd
M8C-EEC118RF433

Remote control transmitter

Jul 28, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote control transmitter - FCC ID M8C-TP36RF433-152 - Fego Precision Industrial Co Ltd
M8C-TP36RF433-152

Remote control transmitter

Apr 02, 2024

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote Controller - FCC ID M8C-TP48RF433 - Fego Precision Industrial Co Ltd
M8C-TP48RF433

Remote Controller

Jun 29, 2021

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Remote Controller - FCC ID M8C-TP50RF433 - Fego Precision Industrial Co Ltd
M8C-TP50RF433

Remote Controller

Jun 26, 2021

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
Transmitter - FCC ID M8CTP40RF304 - Fego Precision Industrial Co Ltd
M8CTP40RF304

Transmitter

Feb 22, 2020

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter