Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Salutron Inc. 40979 Encyclopedia Circle Fremont, CA 94538 Tel: 510-413-9030 Fax: 510-657-7334 www.salutron.com Version: 051012a User Manual for BTS Mod1 Module Note: This User Manual is for internal use only, as this device is a module that would be incorporated into a final assembly. The final assemblies using this module would each have an appropriate User Manual specific to their features/functions. The BTS Mod1 is an electronic sub-assembly for use within Salutron designed health and fitness tracking devices such as sports watches and heart rate monitoring chest straps. The BTS Mod1 will function as the Bluetooth Smart (Low Energy) radio to transmit data to Bluetooth compatible devices such as mobile phones, personal computers, notebooks, etc. For radio function, pairing will be required between the fitness tracking device and the receiving device (mobile phone, personal computer, etc.) Pairing will be automatic based on existing Bluetooth protocols. After the fitness tracking device is powered on, the receiving device will search for the transmitting device. The user will select and confirm the fitness tracking device, and pairing will be complete. After this first time pairing, the receiving device will automatically recognize the fitness tracking device. FCC : Compliance Statement (Part 15.19) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Warning (Part 15.21) Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC Interference Statement (Part 15.105 (b) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. This portable transmitter with its antenna complies with FCC/IC RF exposure limits for general population / uncontrolled exposure. Industry Canada: Section 7.1.2 of RSS-GEN Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. Section 7.1.3 of RSS-GEN This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device. SALUTRON Responsibilities to comply with FCC and Industry Canada Regulations The BTS Mod1 Module has been certified for integration into products only by SALUTRON integrators under the following conditions: -The transmitter module must not be co-located or operating in conjunction with any other antenna or transmitter. As long as this condition above is met, further transmitter testing will not be required. However, the SALUTRON integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed (for example, digital device emissions, PC peripheral requirements, etc.). IMPORTANT NOTE: In the event that this condition cannot be met (for certain configurations or co-location with another transmitter), then the FCC and Industry Canada authorizations are no longer considered valid and the FCC ID and IC Certification Number cannot be used on the final product. In these circumstances, the SALUTRON integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC and Industry Canada authorization. End Product Labeling The BTS Mod1 Module is labeled with its own FCC ID and IC Certification Number. If the FCC ID and IC Certification Number are not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. In that case, the final end product must be labeled in a visible area with the following: “Contains Transmitter Module FCC ID: N7P-BLEMOD1 “Contains Transmitter Module IC: 10274A-BLEMOD1 or “Contains FCC ID: N7P-BLEMOD1 “Contains IC: 10274A-BLEMOD1 The SALUTRON of the BTS Mod1 Module must only use the approved antenna(s) listed above, which have been certified with this module. The SALUTRON integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module or change RF related parameters in the user manual of the end product. To comply with FCC and Industry Canada RF radiation exposure limits for general population, the antenna(s) used for this transmitter must not be co-located or operating in con…
Text truncated - open the document above for the full version.
PRODUCT PHOTOS Company Name Salutron Inc Model # SAL‐BLEMOD1 FCC ID # N7P‐BLEMOD1 IC # 10274A‐BLEMOD1 Page 1 of 1 Front side of module Back side of Module Module compaired to dime
Actual Label Size – 0.25 in x 0.25 in Calibri (body) 1.5 font FCC ID: GDO‐BLEMOD1 IC: 10274A‐BLEMOD1 Model: SAL‐BLEMOD1
PRODUCT PHOTOS Company Name Salutron Inc Model # SAL‐BLEMOD1 FCC ID # N7P‐BLEMOD1 IC # 10274A‐BLEMOD1 Page 1 of 1 Front side of module Back side of Module Module compaired to dime
W66 N220 Commerce Court ● Cedarburg, WI 53012 USA ● Phone: 262.375.4400 ● Fax: 262.375.4248 ● www.lsr.com Prepared For: Salutron, Inc. Name: SAL-BLEMOD1 Report: TR 311272 A FCCICTX V3 Model: SAL-BLEMOD1 LSR: C-1426 Serial: RF Conducted: 12060022; Radiated: 12060028 Page 1 of 31 i. Title Page ENGINEERING TEST REPORT # 311272 (V3) LSR Job #: C-1426 Compliance Testing of: SAL-BLEMOD1 Test Date(s): March 23, 28, 30 2012 Prepared For: Salutron, Inc. 40979 Encyclopedia Circle Fremont, CA 94538 In accordance with: Federal Communications Commission (FCC) Part 15, Subpart C, Section 15.247 Industry Canada (IC) RSS-210 Annex 8 Digital Transmission System (DTS) Operating In the Frequency Band 2400-2483.5 MHz Intentional Radiators This Test Report is issued under the Authority of: Signature: Date: 4-17-12 Test Report Reviewed by: Khairul Aidi Zainal, Senior EMC Engineer Signature: Date: 4/16/12 Report by: Adam Alger Signature: Date: 4-04-12 This Test Report may not be reproduced, except in full, without written approval of LS Research, LLC. Prepared For: Salutron, Inc. Name: SAL-BLEMOD1 Report: TR 311272 A FCCICTX V3 Model: SAL-BLEMOD1 LSR: C-1426 Serial: RF Conducted: 12060022; Radiated: 12060028 Page 2 of 31 ii. Table of Contents Table of Contents i. Title Page ................................................................................................................................... 1 ii. Table of Contents ....................................................................................................................... 2 iii. LS Research, LLC Review ........................................................................................................ 3 1.0 Summary of Test Report ............................................................................................................ 4 2.0 Test Facilities ............................................................................................................................. 4 3.0 Client Information ...................................................................................................................... 5 3.1 Equipment Under Test (EUT) Information ................................................................................ 5 3.2 Product Description ................................................................................................................... 5 3.3 Modifications Incorporated In the EUT for Compliance Purposes ........................................... 6 4.0 Conditions of Test ...................................................................................................................... 6 5.0 Additional Information .............................................................................................................. 6 6.0 Test Equipment .......................................................................................................................... 6 7.0 Declaration of Conformity ......................................................................................................... 7 Appendix A – Test Equipment ............................................................................................................. 8 Appendix B – Setup Photos .................................................................................................................. 9 Appendix C – Test Data ...................................................................................................................... 11 C.1 – RF Conducted Emissions ...................................................................................................... 11 C.2 – Radiated Emissions ............................................................................................................... 17 C.3 – Power Line Conducted Emissions......................................................................................... 25 Appendix D - Uncertainty Summary .................................................................................................. 28 Appendix E - References .................................................................................................................... 29 Appendix F – RF Exposure Exemption .............................................................................................. 30 Prepared For: Salutron, Inc. Report: TR 311272 A FCCICTX V3 LSR: C-1426 iii. LS Research, LLC Review As an EMC Testing Laboratory, our Accreditation and Assessments following: A2LA – American Association for Laboratory Accreditation Accreditation based on ISO/IEC 17025: 2005 A2LA Certificate Number: 1255.01 Federal Communications Commission (FCC) Listing of 3 Meter Semi-Anechoic Chamber based on Title 47 CFR FCC Registration Number: 90756 Industry Canada On file, 3 Meter Semi-Anechoic Chamber based on RSS File Number: IC 3088-A On file, 3 and 10 Meter OATS based on RSS File Number: IC 3088 U. S. Conformity Assessment Body (CAB) Validation Validated by the European Commission as a U. S. Competent Body operating under the U. S./EU, Mutual Recognition A Electromagnetic Compatibility 10.2). Date of Validation: January 16, 2001 Validated by the European Commission as a U.S. Notified Body /EU, Mutual Recognition Agreement (MRA) operating under the European Union Telecommunication Equipment Date of Validation: November 20, 2002 Notified Body Identification Number: 1243 Name: SAL-BLEMOD1 Model: SAL-BLEMOD1 Serial: RF Conducted: 12060022; Radiated: 12060028 Page 3 of 31 LS Research, LLC Review LS Research, LLC in Review As an EMC Testing Laboratory, our Accreditation and Assessments are recognized through the American Association for Laboratory Accreditation Accreditation based on ISO/IEC 17025: 2005 with Electrical (EMC) Scope of A2LA Certificate Number: 1255.01 Federal Communications Commission (FCC) – USA Anechoic Chamber based on Title 47 CFR – Part 2.948 FCC Registration Number: 90756 Anechoic Chamber based on RSS-212 – Issue 1 On file, 3 and 10 Meter OATS based on RSS-…
Text truncated - open the document above for the full version.
TEST SETUP PHOTOS Company Name Salutron Inc Model # SAL-BLEMOD1 FCC ID # N7P-BLEMOD1 IC # 10274A-BLEMOD1 Page 1 of 2 Radiated Emissions Battery Powered (Flat) Radiated Emissions Battery Powered (Side) Radiated Emissions Battery Powered (Vertical) Radiated Emissions AC Powered (Flat) TEST SETUP PHOTOS Company Name Salutron Inc Model # SAL-BLEMOD1 FCC ID # N7P-BLEMOD1 IC # 10274A-BLEMOD1 Page 2 of 2 Radiated Emissions AC Powered (Side) Radiated Emissions AC Powered (Vertical) RF Conducted Emissions AC Power RF Conducted Emissions Battery Power AC Power Conducted Emissions
40979 Encyclopedia Circle · Fremont, California · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.40 GHz - 2.48 GHz | 1.15 mW |

R Series Activity & Wellness Monitor with Heart Rate Measurement, Spectral Ambient Light Sensor & Intelligent Alerts
Equipment Class
DTS - Digital Transmission System
R Series Activity & Wellness Monitor with Heart Rate Measurement, Spectral Ambient Light Sensor & Intelligent Alerts
Equipment Class
DTS - Digital Transmission System
C Series Free Living Monitor
Equipment Class
DTS - Digital Transmission System
Dual Mode Chest Strap BLE+5kHz Standard Soft Case
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
BLE/5kHz Heart Rate Monitor, Molded Chest Strap (Hard), Uncoded
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter