FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Salutron Inc./
  3. N7P-R450

N7P-R450R Series Activity & Wellness Monitor with Heart Rate Measurement, Spectral Ambient Light Sensor & Intelligent Alerts

Salutron Inc.
R Series Activity & Wellness Monitor with Heart Rate Measurement, Spectral Ambient Light Sensor & Intelligent Alerts - FCC ID N7P-R450 - Salutron Inc.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 16, 2015
Application Purpose
Original Equipment
Date of Application
Apr 15, 2015
Equipment Note
R Series Activity & Wellness Monitor with Heart Rate Measurement, Spectral Ambient Light Sensor & Intelligent Alerts
Frequency Range
2402.00000000 - 2480.00000000
Company
Salutron Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Goal Progress Bar Time/Date LightTrak Sensor Activity Value Activity Type Notification Alert Quick Start Guide BRITE R450 Welcome to LifeTrak. Let’s take a quick tour of the basic features. To turn on your life tracker, press and hold any button. Learn more For full instructions, helpful tips and product information, see the LifeTrak User Guide at www.lifetrakusa.com/user-guides. NOTE: Actual model/screen images may vary from images shown. Table of Contents Button Layout......................................................................................... User Info................................................................................................ Time Setup............................................................................................ Bluetooth® Connection...................................................................... Notifications...................................................................................... LightTrak.......................................................................................... Goal Setup........................................................................................... Heart Rate............................................................................................ SleepTrak 2.0.................................................................................. Inactivity Alert...................................................................................... Hourly Display................................................................................ Weekly Display.................................................................................... Workout Mode................................................................................ Contact.................................................................................. 1 2 3 4-6 7-10 11-12 13 14 15-19 20 21-22 23 24-25 Back Cover MODE Press to change modes: Time Notifications Hourly Weekly Workout START/STOP Press to start and stop in Workout Press to view: distance calories steps sleep Press & hold to read your heart rate LIGHT Press MODE + START/STOP, MODE + VIEW or double-click VIEW In the dark, pressing VIEW will also activate light VIEW NOTE: The buttons are not intended for use under water BUTTON LAYOUT 1 MODE Press to change modes: Time Notifications Hourly Weekly Workout In Time, hold MODE for 3 sec Select USER INFO 1 2 USER INFO INSIDE SETTING MODE gender birthday (year) birthday (month) birthday (day) unit format weight height Edit/increase value Edit/decrease value Press: go to next setting Press & hold: exit setting mode 2 seconds minute hour year month day month-day format 12/24 hr format In Time, hold MODE for 3 sec 1 2 TIME SETUP INSIDE SETTING MODE Select TIME Edit/increase value Edit/decrease value Press: go to next setting Press & hold: exit setting mode 3 Transfer data between your life tracker and Bluetooth Smart Ready devices. Even get notified of phone calls, emails and messages right on your tracker. Before you can transfer data, you must install our LifeTrak app on your Bluetooth Smart Ready device. You will also have the ability to set up your tracker (e.g., set user info and goals) through the app. Visit www.lifetrakusa.com/app or your app store. Bluetooth Smart Ready Device Setup Once the LifeTrak app is installed, make sure Bluetooth on your device is turned on and then open the app. Tap on “Connect a New Watch.” Locate your LifeTrak activity tracker and tap on “Connect to Device.” The device will now attempt to pair. Next step: set up your life tracker. BLUETOOTH ® CONNECTION 4 Brite R450 Setup Now that your device is attempting to pair, we need your life tracker to do the same. While in Time, press and hold START/STOP until it activates a signal animation on the screen. Your tracker will now attempt to pair with your device. NOTE: For best results, keep your devices within 2 meters of each other when pairing. START/STOP Hold to begin pairing (must be in Time). Button can be released once pairing action begins. Bluetooth Indicator BLUETOOTH CONNECTION 5 BLUETOOTH CONNECTION Syncing Data Once the life activity tracker and your device are paired, you can now sync fitness data and notifications. While notifications will sync automatically whenever one comes through, syncing your fitness data is done manually with a simple one-step process each time you wish to transfer the data. To transfer your fitness data from life tracker to device, simply open your app and click on the reload button at the top-right corner. See the Bluetooth Indicator Status on this page for detailed information. Indicator Status (activity tracker) Solid: Bluetooth is on and linked to a device Flashing: Bluetooth is trying to establish a connection No icon: Bluetooth is off 6 NOTE: Bluetooth on your device must be turned on to receive notifications. NOTIFICATIONS You will be able to receive notifications like phone calls, emails and messages right on your life tracker. You must pair your tracker with our LifeTrak app to receive notifications. Visit www.lifetrakusa.com/app or your app store to download. Once paired, calls and messages from your Bluetooth Smart Ready device will automatically be sent to your tracker. Displayed if there are no messages on your tracker Notifications mode Example of an email notification on your tracker 7 NOTIFICATIONS Symbol Notification Type Generic/Social Alert SMS/MMS Message Instant Message News Feed Calendar/Planner Alert High Priority Alert Incoming Call Missed Call or Email Symbol Notification Type 8 NOTIFICATIONS START/STOP Press to browse through your messages VIEW Press & hold to delete messages From Time, press MODE until you reach Notifications Up to 20 notifications can be stored on your activity tracker. Select which types of notifications you want sent to your tracker through the LifeTrak app settings. 9 NOTIFICATIONS Delete notifications You can delete a single message or all messages depending on h…

Text truncated - open the document above for the full version.

Cover Letter(s)

Salutron Inc. Date: 02/21/2015 Authority to Act as an Agent We declare that the following representative (agent) Name Bovey yang Position Manager Company Name BZT Testing Technology Co., Ltd. Address 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street Bao an District Tel / Fax (86)-0755-61156588/(86)-0755-61156599 Email [email protected] to act on our behalf on all matters concerning the application and documents submitted to PHOENIX TEST-LAB for product certification below Product Name R Series Activity & Wellness Monitor with Heart Rate Measurement, Spectral Ambient Light Sensor & Intelligent Alerts Model Name R450, LTK7R45002R, LTK7R45004R, LTK7R45005R, R450 E Brand Name Life Trak FCC ID N7P-R450 . Yours sincerely, Signatory Name Yong Jin Lee Position VP Engineering Company Name Salutron Inc. Address 47787 Fremont Blvd, Fremont, California 94538,United States Tel 510-413-9030 Fax 510-657-7334 Email [email protected] In case of FCC, we certify that we are not subject to a denial of Federal benefits, that include FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance.

Cover Letter(s)

Salutron Inc. Federal Communications Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MD 21046 Request for Confidentiality Company name: Salutron Inc. FCC ID : N7P-R450 FCC Part 15 Certification Gentlemen, Pursuant to 47 CFR 0.457(d)(1)(ii) and 0.459 we hereby requests permanent confidentiality of the following documents for the subject application: Exhibit Type Description ☒ Schematics All circuitry of devices and component values ☒ Block Diagrams Details of device showing the frequency of all oscillators ☒ Operational Description Description of the circuit functions Note: Exhibit types that are commonly held confidential are: (1) Schematics, (2) Block Diagrams, (3) Bill Of Materials, (4) Operational Descriptions. Any exhibit NOT granted confidentiality is viewable on the FCC website as soon as a grant is issued. These documents contain detailed system and equipment description and related information about the product which we considers to be proprietary, confidential and a custom design and otherwise would not release to the general public. Since the design is a basis from which future technological products will evolve, we consider that this information would be of benefit to its competitors and that the disclosure of the information in these documents would give competitors an unfair advantage in the market. Yours sincerely, Signatory Name Yong Jin Lee Position VP Engineering Company Name Salutron Inc. Address 47787 Fremont Blvd, Fremont, California 94538,United States Tel 510-413-9030 Fax 510-657-7334 Email [email protected] Date 02.21.2015

Cover Letter(s)

Differences Description We Salutron Inc. state: Product name: R Series Activity & Wellness Monitor with Heart Rate Measurement, Spectral Ambient Light Sensor & Intelligent Alerts Model: R450, LTK7R45002R, LTK7R45004R, LTK7R45005R, R450 E All model’s the function, software and electric circuit are the same , only with a product color and model named different. Signatory Signature Name(in block letter) Yong Jin Lee Title (in block letter) VP Engineering Company Name Salutron Inc. Address 47787 Fremont Blvd, Fremont, California 94538,United States Te l 510-413-9030 Fax 510-657-7334 Email [email protected] Date 03.2 5.2015

External Photos

Full View Top View Bottom View Rear View Left View Right View Front View

ID Label/Location Info

Label Location

ID Label/Location Info

Label: FCC ID: N7P-R450 IC: 10274A-R450 Salutron Inc. Model name: R450

Internal Photos

Internal View Internal View Internal View Internal View Internal View Internal View Internal View Antenna

Test Report

FCC RADIO TEST REPORT FCC ID: N7P-R450 IC: 10274A-R450 Product: R Series Activity & Wellness Monitor with Heart Rate Measurement, Spectral Ambient Light Sensor & Intelligent Alerts Trade Name: Life Trak Model Name: R450 Serial Model: LTK7R45002R, LTK7R45004R, LTK7R45005R, R450 E Report No.: BZT-2014NT0925271F Prepared for Salutron Inc. 47787 Fremont Blvd, Fremont, California 94538,United States Prepared by BZT Testing Technology Co., Ltd Add. : 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao’an District, Shenzhen P.R. China. Page 2 of 39 Report No.: BZT-2014NT0925271F TEST RESULT CERTIFICATION Applicant’s name .............. Salutron Inc. Address .............................. 47787 Fremont Blvd, Fremont, California 94538,United States Manufacture's Name ......... Fairlegend Electronics, Ltd. Address .............................. Shang Cun, Yuan Shan Industrial Zone B, Gongming, Guangming New District, Shenzhen, China Product description Product name ....................... R Series Activity & Wellness Monitor with Heart Rate Measurement, Spectral Ambient Light Sensor & Intelligent Alerts Model and/or type reference ........................... R450 Serial Model .......................... LTK7R45002R, LTK7R45004R, LTK7R45005R, R450 E DIFF ....................................... All model’s the function, software and electric circuit are the same, only with a product color and model named different.Test sample model: R450 Standards .......................... FCC Part15.247 RSS 210 ISSUE 8 Test procedure ...................... ANSI C63.4-2 003 This device described above has been tested by BZT, and the test results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only to the tested sample identified in the report. This report shall not be reproduced except in full, without the written approval of BZT, this document may be altered or revised by BZT , personal only, and shall be noted in the revision of the document. Date of Test .......................................... Date (s) of performance of tests ........... 25 August. 2014 ~29 August. 2014 Date of Issue ......................................... 30 August. 2014 Test Result ............................................. Pass Testing Engineer : (Lynn Chen) Technical Manager : (Carlen Liu) Authorized Signatory : (Tommy zhang) Page 3 of 39 Report No.: BZT-2014NT0925271F Table of Contents Page 1 . SUMMARY OF TEST RESULTS 5 1.1 TEST FACILITY 6 1.2 MEASUREMENT UNCERTAINTY 6 2 . GENERAL INFORMATION 7 2.1 GENERAL DESCRIPTION OF EUT 7 2.2 DESCRIPTION OF TEST MODES 9 2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10 2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE) 11 2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS 12 3 . EMC EMISSION TEST 13 3.1 CONDUCTED EMISSION MEASUREMENT 13 3.1.1 POWER LINE CONDUCTED EMISSION LIMITS 13 3.1.2 TEST PROCEDURE 14 3.1.3 DEVIATION FROM TEST STANDARD 14 3.1.4 TEST SETUP 14 3.1.5 EUT OPERATING CONDITIONS 14 3.1.6 TEST RESULTS 15 3.2 RADIATED EMISSION MEASUREMENT 16 3.2.1 RADIATED EMISSION LIMITS 16 3.2.2 TEST PROCEDURE 17 3.2.3 DEVIATION FROM TEST STANDARD 17 3.2.4 TEST SETUP 18 3.2.5 EUT OPERATING CONDITIONS 18 3.2.6 TEST RESULTS (BETWEEN 9KHZ – 30 MHZ) 19 3.2.7 TEST RESULTS (BETWEEN 30MHZ – 1GHZ) 20 3.2.8 TEST RESULTS (ABOVE 1000 MHZ) 22 3.2.9 TEST RESULTS (RESTRICTED BANDS REQUIREMENTS) 25 4 . POWER SPECTRAL DENSITY TEST 29 4.1 APPLIED PROCEDURES / LIMIT 29 4.1.1 TEST PROCEDURE 29 4.1.2 DEVIATION FROM STANDARD 29 4.1.3 TEST SETUP 29 4.1.4 EUT OPERATION CONDITIONS 29 4.1.5 TEST RESULTS 30 5 . BANDWIDTH TEST 32 5.1 APPLIED PROCEDURES / LIMIT 32 Page 4 of 39 Report No.: BZT-2014NT0925271F Table of Contents Page 5.1.1 TEST PROCEDURE 32 5.1.2 DEVIATION FROM STANDARD 32 5.1.3 TEST SETUP 32 5.1.4 EUT OPERATION CONDITIONS 32 5.1.5 TEST RESULTS 33 6 . PEAK OUTPUT POWER TEST 36 6.1 APPLIED PROCEDURES / LIMIT 36 6.1.1 TEST PROCEDURE 36 6.1.2 DEVIATION FROM STANDARD 36 6.1.3 TEST SETUP 36 6.1.4 EUT OPERATION CONDITIONS 36 6.1.5 TEST RESULTS 37 7 . ANTENNA REQUIREMENT 38 7.1 STANDARD REQUIREMENT 38 7.2 EUT ANTENNA 38 8 . EUT TEST PHOTO 39 APPENDIX-PHOTOGRAPHS OF EUT CONSTRUCTIONAL DETAILS Page 5 of 39 Report No.: BZT-2014NT0925271F 1. SUMMARY OF TEST RESULTS Test procedures according to the technical standards: FCC Part15 (15.247) , Subpart C RSS 210 ISSUE 8 Standard Section Test Item Judgment Remark 15.207 Conducted Emission N/A 15.247 (a)(2) 6dB Bandwidth PASS 15.247 (b) Peak Output Power PASS 15.247 (c) Radiated Spurious Emission PASS 15.247 (d) Power Spectral Density PASS 15.205 Band Edge Emission PASS 15.203 Antenna Requirement PASS NOTE: (1)” N/A” denotes test is not applicable in this Test Report Page 6 of 39 Report No.: BZT-2014NT0925271F 1.1 TEST FACILITY BZT Testing Technology Co., Ltd Add.:1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao’an District, Shenzhen P.R. China. FCC Registration No.: 701733 1.2 MEASUREMENT UNCERTAINTY The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of approximately 95 %。 No. Item Uncertainty 1 Conducted Emission Test ±1.38dB 2 RF power,conducted ±0.16dB 3 Spurious emissions,conducted ±0.21dB 4 All emissions,radiated(<1G) ±4.68dB 5 All emissions,radiated(>1G) ±4.89dB 6 Temperature ±0.5°C 7 Humidity ±2% Page 7 of 39 Report No.: BZT-2014NT0925271F 2. GENERAL INFORMATION 2.1 GENERAL DESCRIPTION OF EUT Equipment R Series Activity & Wellness Monitor with Heart Rate Measurement, Spectral Ambient Light Sensor & Intelligent Alerts Trade Name Life Trak Model Name R450 Serial Model LTK7R45002R, LTK7R45004R, LTK7R45005R, R450 E Model Difference All model’s the function, software and electric circuit are the same, only with a product color and model named different.Test sample model: R450 Product Description The EUT is a R Series Activity & Wellness Monitor w…

Text truncated - open the document above for the full version.

Test Setup Photos

Radiated Emission Test Setup in Chamber

Contact Information

Applicant

Bill Chau(Sr.Hardware Engineering Manager)
[email protected]510-795-2876Fax: 510-795-2829

Test Firm

BZT Testing Technology Co., Ltd.Bruce Zhang
[email protected](86)-0755-33071680Fax: (86)-0755-27341758

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz239.00 µW
Confidentiality
Long Term
Grant Notes
Output power listed is peak conducted.

Other Applications from Salutron Inc.

R Series Activity & Wellness Monitor with Heart Rate Measurement, Spectral Ambient Light Sensor & Intelligent Alerts - FCC ID N7P-HRW03 - Salutron Inc.
N7P-HRW03

R Series Activity & Wellness Monitor with Heart Rate Measurement, Spectral Ambient Light Sensor & Intelligent Alerts

Dec 21, 2015

Equipment Class

DTS - Digital Transmission System
C Series Free Living Monitor - FCC ID N7P-HRW01 - Salutron Inc.
N7P-HRW01

C Series Free Living Monitor

Dec 12, 2013

Equipment Class

DTS - Digital Transmission System
Dual Mode Chest Strap BLE+5kHz Standard Soft Case - FCC ID N7P-HRS02 - Salutron Inc.
N7P-HRS02

Dual Mode Chest Strap BLE+5kHz Standard Soft Case

Aug 29, 2012

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
BLE/5kHz Heart Rate Monitor, Molded Chest Strap (Hard), Uncoded - FCC ID N7P-HRS01 - Salutron Inc.
N7P-HRS01

BLE/5kHz Heart Rate Monitor, Molded Chest Strap (Hard), Uncoded

Aug 14, 2012

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
BTS Mod1 (Module) - FCC ID N7P-BLEMOD1 - Salutron Inc.
N7P-BLEMOD1

BTS Mod1 (Module)

May 14, 2012

Equipment Class

DTS - Digital Transmission System