Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
OWNER’S MANUAL TOUCHSCREEN MOVEMENT & SOUND MONITOR Model AC701 FOR YOUR PEACE OF MIND ES 55 FR 27 EN 2 TOUCHSHSCREEENNMOOVEVMEMENNT & SOUND MONITOR Model AC701 Pre-programmed to monitor sound and movement. Sensor Pad will alarm if no movement is detected. 01mf5_manuel_NA_AC701_12002.indd 12013-12-19 1:35 PM TABLE OF CONTENT OWNER’S MANUAL KEEP YOUR OWNER’S MANUAL FOR FUTURE REFERENCE. PLEASE READ THE WARNINGS AND INSTRUCTIONS CAREFULLY BEFORE ASSEMBLING & USING THE PRODUCT. FAILURE TO FOLLOW THE WARNINGS AND THE INSTRUCTIONS COULD RESULT IN SERIOUS INJURY OR DEATH OR DAMAGES TO THE PRODUCT. THE SENSOR PAD FEATURE IS NOT FOR USE WITH ADULTS, CHILDREN OR INFANTS OLDER THAN 24 MONTHS. THE SENSOR PAD IS NOT INTENDED TO BE USED TO DETERMINE IF A CHILD IS OUT OF THE CRIB. WARNING Adult assembly required. Keep small parts away from children when assembling. We, at Angelcare ® , stand behind all of our products. If you are not completely satisfied or have any questions, United States and Canada: please contact us at: [email protected] Other countries: please contact your local Distributor. WARNINGS .................................................................................. 3 AC701 SETUP REQUIREMENTS .................................................... 7 STEP 1 - Charging the parent unit (15 hours) ........................... 8 STEP 2 - Installing the sensor pad .............................................. 9 STEP 3 - Setting up the nursery unit ......................................... 12 STEP 4 - Turning on your monitor ..............................................13 STEP 5 - Testing and getting to know your monitor ............14 STEP 6 - To activate and deactivate additional functions ........................................................................18 Troubleshooting ............................................................................... 23 Limited warranty .............................................................................. 25 Technical specifications .................................................................26 FRANÇAIS .......................................................................................... 27 ESPAÑOL ............................................................................................55 2 01mf5_manuel_NA_AC701_12002.indd 22013-12-19 1:35 PM WARNINGS 1. THIS PRODUCT CANNOT REPLACE RESPONSIBLE ADULT SUPERVISION. This p ro d u c t i s d e s i g n e d to a i d i n t h e m o n i to r i n g of your child . When using the monitor, you must still provide the supervision necessary for the continued safety of your child. Monitoring of premature babies, or those considered to be at risk, should always be carried out under the supervision of a health professional. This monitor is not intended to be used as a medical monitor. 2. Strangulation Hazard—Children have STRANGLED in cords. Keep adapter cords out of the reach of children (more than 3 feet (1m) away) NEVER attempt to use Sensor Pad without the protective cord covering. Check protective cord covering before each use to ensure it is securely placed under the leg of the crib. Discontinue use of Sensor Pad if protective covering is damaged or broken. 3. Never use extension cords with AC adapters. ONLY use the AC adapters provided. 4. When an AC Adapter is plugged into an electrical outlet, DO NOT touch the exposed end. 5. ALWAYS be sure that both the transmitter and receiver are working properly and are within range of each other. Test monitor before first use, periodically and when changing location of the Nursery Unit. 6. ALWAYS be sure to immediately check on baby whenever an alarm sounds. 7. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN DO NOT EXPOSE TO RAIN OR MOISTURE DO NOT use monitor near water (such as bath tub, sink, etc.). 8. Keep monitor AWAY from heat sources (such as stoves, radiators, etc.). 9. ALWAYS place both the Nursery Unit and Parent Unit on a flat surface in an upright position and allow for proper ventilation. DO NOT place on sofas, cushions, beds, etc. which may block ventilation. 10. This monitor uses public airwaves to transmit signals. The Parent Unit may pick up signals or interference from other nursery monitors in your area. Your monitor may even be picked up by other households. To protect your privacy, make sure both units are turned OFF when not in use. If you experience interference, change the channel on both units. 11. This product is NOT a toy. DO NOT allow children to play with it. 12. This product contains small parts. Adult assembly required. Exercise care when unpacking and assembling the product and keep small parts away from children. 13. When using the monitor, the room temperature should be between 50°F (10°C) and 104°F (40°C). BATTERY WARNING 14. Use ONLY AAA RECHARGEABLE batteries for the Parent Unit. DO NOT mix old and new batteries. DO NOT mix alkaline, standard or rechargeable batteries. Insert batteries with correct polarity. DO NOT short-circuit supply terminals. ONLY use the recommended batteries or equivalent (volts and size) and the correct adapter. Remove batteries when product is stored for long periods of time or when batteries are exhausted. Dispose exhausted batteries properly. DO NOT recharge non-rechargeable batteries. Rechargeable batteries are ONLY to be charged under adult supervision. Keep all batteries away from children. 3 E N 01mf5_manuel_NA_AC701_12002.indd 32013-12-19 1:35 PM 15. IMPORTANT SAFETY INSTRUCTIONS 15.1 Read these instructions - All the safety instructions should be read before the product is operated. 15.2 Keep these instructions. The safety and operating instructions should be retained for future reference. 15.3 Heed all warnings – All warnings on the product and in the operating instructions should be adhered to. 15.4 Follow all instructions – All operating and use instructions should be followed. 15.5 Water and moisture - DO NOT use this apparatus near water. For example, near a bath tub, wash bow…
Text truncated - open the document above for the full version.
INTERTEK TESTING SERVICES External Photos FCC ID: N7TAC701R IC: 5786A-AC701Rexternal photos - 1 of 1 HK13080975 Job Number HK13080975 Job Number
00mA BC Use only power supplies listed on the user instructions Utiliser seulement les adaptateurs mentionés dans le manuel d'instructions AC701 Rev. 0 09/21/2013 Engrave AC701MODEL:AC701-PMODEL: (model # AC701-P for Canada) 18.5mm x 1.5mm 17.0mm x 1.5mm 22.0mm x 1.5mm 00mA BC Use only power supplies listed on the user instructions Utiliser seulement les adaptateurs mentionés dans le manuel d'instructions AC720 Rev. 0 11/14/2013 Engrave (model # AC720-P for Canada) 18.5mm x 1.5mm 17.0mm x 1.5mm 22.0mm x 1.5mm AC720MODEL:AC720-PMODEL:
INTERTEK TESTING SERVICES Internal photos FCC ID: N7TAC701R IC: 5786A-AC701R internal photos - 1 of 5 Parent Unit assembly Parent Unit Main PCB comp side INTERTEK TESTING SERVICES Internal photos FCC ID: N7TAC701R IC: 5786A-AC701R internal photos - 2 of 5 Parent Unit Main PCB solder side (View 1) Parent Unit Main PCB solder side (View 2) INTERTEK TESTING SERVICES Internal photos FCC ID: N7TAC701R IC: 5786A-AC701R internal photos - 3 of 5 Parent Unit Power Key front side Parent Unit Power Key rear side INTERTEK TESTING SERVICES Internal photos FCC ID: N7TAC701R IC: 5786A-AC701R internal photos - 4 of 5 Parent Unit Key Board front side Parent Unit Key Board rear side INTERTEK TESTING SERVICES Internal photos FCC ID: N7TAC701R IC: 5786A-AC701R internal photos - 5 of 5 Parent Unit Oscillator PCB comp side
Report No.: 13080977HKG-001 Page 1 of 81 - The test report only allows to be revised within the retention period unless further standard or the requirement was noticed. - This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com Specific Absorption Rate (SAR) Evaluation Report For Digital Baby Monitor (Parent Unit) Model Number: AC701 Brand Name: Angelcare FCC ID: N7TAC701R Test Report: 13080977HKG-001 Date of Report: 04 October, 2013 Prepared for Angelcare Monitors Inc. 9975, Av. De Catania, Local B, Brossard, Quebec, J4Z 3V6, Canada Prepared and Checked by: Approved by: Chan Chun Foo, Bike Senior Lead Engineer Date: 04 October, 2013 Nip Ming Fung, Melvin Assistant Manager Date: 04 October, 2013 2349 Report No.: 13080977HKG-001 Page 2 of 81 Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com Table of Contents 1.0 General Information.............................................................................................. 3 2.0 Measurement System Description and Procedure ............................................... 6 3.0 Tissue Verification .............................................................................................. 14 4.0 SAR Measurement System Verification ............................................................. 15 5.0 SAR Evaluation .................................................................................................. 18 6.0 Test Instruments ................................................................................................ 24 7.0 Measurement Uncertainty .................................................................................. 25 8.0 E-Field Probe and 1900 Dipole Antenna Calibration.......................................... 25 9.0 References ......................................................................................................... 25 APPENDIX A - System Verification Data .................................................................. 26 APPENDIX B - SAR Evaluation Data ....................................................................... 28 APPENDIX C - E-Field Probe and 1900MHz Dipole Antenna Calibration Data ....... 34 APPENDIX D - SAR Tissue Specification ................................................................ 80 APPENDIX E - SAR System Validation.................................................................... 81 Report No.: 13080977HKG-001 Page 3 of 81 - Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 1.0 General information 1.1 Test Result Summary Applicant : Angelcare Monitors Inc. Applicant Address : 9975, Av. De Catania, Local B, Brossard, Quebec, J4Z 3V6, Canada Model : AC701 Brand Name : Angelcare EUT Description : Digital Baby Monitor (Parent Unit) Exposure Category : General Population/Uncontrolled Exposure Test Device : Production Unit Date of Sample Received : 26 August, 2013 Date of Test: : 30 August, 2013 Date of Report: : 04 October, 2013 Place of Testing : Intertek Testing Services Hong Kong 5/F Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong Environmental Conidtions: : Temperature: +20 to 25°C Humidity: 30 to 70% Test Specification : ANSI/IEEE C95.1: 1992 IEEE Std 1528: 2003 IEEE Std 1528a: 2005 FCC KDB Publication 447498 D01 v05r01 FCC KDB Publication 865664 D01 v01r01 FCC KDB Publication 865664 D02 v01r01 The maximum spatial peak SAR value for the sample device averaged over 1g was found to be: Highest Reported SAR Band Operating Mode TX Frequency (MHz) 1 g Head 1g Body-Worn 1.9GHz DECT Voice 1921.536 – 1928.448 0.027 W/kg 0.044 W/kg This wireless portable device has been shown to be capable of compliance for localized specific absorption rate (SAR) for uncontrolled environment / general population exposure limits specified in ANSI/IEEE C95.1. Report No.: 13080977HKG-001 Page 4 of 81 - Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com 1.2 Description of Equipment under test (EUT) EUT Description : Digital Baby Monitor (Parent Unit) Model : AC701 Brand Name : Angelcare FCC ID : N7TAC701R Serial Number : N/A Manufacturer : Artcom Limited Manufacturer Address : Unit 301, 3/F., Hewlett Centre, 52-54 Hoi Yuen Road, Kwun Tong, Kowloon, Hong Kong Device dimension (L x W) : 125 (mm) x 58 (mm) Device thickness : 20 (mm) to 35 (mm) Operating Configuration(s) / mode : Face and Body-worn (Voice call) RF Exposure Condition(s) : In-front-of the face Body-worn Device Category : Portable Device Tx Frequency : 1921.536 – 1928.448 MHz (UPCS) Duty Cycle* : 1/24 Battery Type : 2 x 1.2V “AAA” 600mAH GP Ni-MH rechargeable battery 2 x 1.2V “AAA” 600mAH HFR Ni-MH rechar…
Text truncated - open the document above for the full version.
INTERTEK TESTING SERVICES Front position with 0mm separation Back position with 0mm separation
INTERTEK TESTING SERVICES Page 1 of 2 EUT Photo Figure 1 – Parent Unit front view Figure 2 – Parent Unit back view INTERTEK TESTING SERVICES Page 2 of 2 Figure 3 – 2 x 1.2V 600mAH GP Ni-MH rechargeable battery Figure 4 – 2 x 1.2V 600mAH HFR Ni-MH rechargeable battery
Issuing Laboratory: Intertek Testing Services Hong Kong Limited Hong Kong Accreditation Service (HKAS) has accredited this laboratory under the Hong Kong Laboratory Accreditation Scheme (HOKLAS) for specific laboratory activities as listed in the HOKLAS directory of accredited laboratories. The results shown in this report were determined by this laboratory in accordance with its terms of accreditation. Test Report Number: 13080975HKG-002 Page 1 of 64 FCC ID: N7TAC701R IC: 5786A-AC701R Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com GENERAL INFORMATION Angelcare Monitors Inc.: Angelcare Monitors Inc. Applicant Address: 9975, Av. De Catania Local B, Brossard, Quebec, J4Z 3V6 Canada FCC Specification Standard: FCC Part 15, October 1, 2012 FCC ID: N7TAC701R FCC Model(s): AC701, AC720 IC Specification Standard: RSS-213 Issue 2, December 2005 RSS-Gen Issue 3, December 2010 IC: 5786A-AC701R IC Model(s): AC701-P, AC720-P Type of EUT: Unlicensed Personal Communications Service Devices Description of EUT: 1.9GHz Digital Modulation Baby Monitor - Parent Unit Serial Number: N/A Sample Receipt Date: August 22, 2013 Date of Test: September 3, 2013 to September 22, 2013 Report Date: November 15, 2013 Environmental Conditions: Temperature: +10 to 40°C Humidity: 10 to 90% Issuing Laboratory: Intertek Testing Services Hong Kong Limited Hong Kong Accreditation Service (HKAS) has accredited this laboratory under the Hong Kong Laboratory Accreditation Scheme (HOKLAS) for specific laboratory activities as listed in the HOKLAS directory of accredited laboratories. The results shown in this report were determined by this laboratory in accordance with its terms of accreditation. Test Report Number: 13080975HKG-002 Page 2 of 64 FCC ID: N7TAC701R IC: 5786A-AC701R Intertek Testing Services Hong Kong Ltd. 2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. Tel: (852) 2173 8888 Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com Table of Contents 1.0 Test Results Summary & Statement of Compliance.............................................. 5 1.1 Summary of Test Results ....................................................................................... 5 1.2 Statement of Compliance ....................................................................................... 6 2.0 General Description................................................................................................. 8 2.1 Product Description ................................................................................................. 8 2.2 Technical Description .............................................................................................. 8 2.3 Test Methodology.................................................................................................... 9 2.4 Test Facility............................................................................................................. 9 3.0 System Test Configuration.................................................................................... 11 3.1 Justification ........................................................................................................... 11 3.2 Conducted Emission Test Configuration ................................................................ 12 3.3 Conducted Monitoring and Operational Test Configuration .................................... 12 3.4 EUT Exercising Software....................................................................................... 12 3.5 Details of EUT and Description of Accessories...................................................... 13 3.6 Measurement Uncertainty ..................................................................................... 13 4.0 Measurement Results............................................................................................ 15 4.1 Antenna Requirement........................................................................................... 15 4.2 Digital Modulation Techniques............................................................................... 15 4.3 Emission Bandwidth.............................................................................................. 16 4.4 Directional Gain of the Antenna ............................................................................. 19 4.5 Peak Transmit Power ............................................................................................ 20 4.6 Power Spectral Density ......................................................................................... 23 4.7 Automatic Discontinuation of Transmission............................................................ 26 4.8 Unwanted Emission Inside the Sub-Band .............................................................. 27 4.9 Emissions Outside the Sub-Band .......................................................................... 31 4.9.1 Radiated Emissions Configuration Photographs ................................................. 32 4.9.2 Radiated Emissions Data ................................................................................... 32 4.9.3 Field Strength Calculation................................................................................... 36 4.9.4 Average Factor Calculation and Transmitter ON Time Measurements ................ 37 4.10 AC Power Line Conducted Emissions ................................................................. 38 4.10.1 AC Power Line Conducted Emissions Configuration Photographs .................... 39 4.10.2 AC Power Line Conducted Emissions Data ...................................................... 39 4.11 Frame Repetition Stability .................................................................................. 44 4.12 Frame Period and Jitter ...................................................................................... 45 4.13 Ca…
Text truncated - open the document above for the full version.
INTERTEK TESTING SERVICES The Worst Case Configuration Photographs - Mode: Transmission FCC ID: N7TAC701R IC: 5786A-AC701R config photos (radiated emission) - 1 of 1 Radiated Emission Front View Rear View INTERTEK TESTING SERVICES The Worst Case Configuration Photographs - Mode: Receiving Mode and Sensor Pad Alarm On FCC ID: N7TAC701R IC: 5786A-AC701R config photos (conducted emission) - 1 of 2 Conducted Emission Front View Right Side View INTERTEK TESTING SERVICES The Worst Case Configuration Photographs - Mode: Receiving Mode and Sensor Pad Alarm On FCC ID: N7TAC701R IC: 5786A-AC701R config photos (conducted emission) - 2 of 2 Conducted Emission Left Side View
Flat D, 5/F., Garment Centre · Kowloon · Hong Kong
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15D | 1.92 GHz - 1.93 GHz | 74.00 mW |

Video Baby Monitor - Baby Unit
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Video Baby Monitor - Parent Unit
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
900MHz Superheterodyne Receiver (Parent Unit)
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
900MHz Analog Modulation Baby Monitor (Baby Unit)
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
1.9GHz DECT Baby Monitor - Baby Unit
Equipment Class
PUB - Part 15 Unlicensed PCS Base Station