Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
MEDI-CALL UNIT USER MANUAL 1 TABLE OF CONTENTS TABLE OF CONTENTS...........................................1 INTRODUCTION......................................................1 SMARTLINK FEATURES........................................2 USING SMARTLINK................................................3 SPECIAL FUNCTIONS.............................................5 DISPLAYS AND WARNINGS..................................6 SPECIFICATIONS....................................................7 INTRODUCTION Your SmartLink Medi-Call unit has been designed to provide you with the freedom and peace of mind in that, should you need assistance or HELP, it is available to you 24 hours a day with the simple press of a Button. The modern slim line design of the SmartLink Medi-Call unit allows it to be installed unobtrusively anywhere and is ready when you need help. HELP can be summonsed by pressing a Button on your personal Pendant or Wristwatch, which you can wear both inside your home or outside in the garden, ready for any emergency, giving you the freedom you enjoy for total control at all times. The SmartLink Medi-Call unit has been built to the highest of technical standards for the protection of people and property and manufactured to Australian and International quality standards. Your SmartLink Medi-Call unit can be supplied with additional fixed or portable Radio Key Pendants, which can be worn or placed around the home as needed. Please contact your supplier for more information. 2 SMARTLINK FEATURES 3 PENDANTS (WRISTWATCH or CHAIN) DETECTORS USING SMARTLINK NORMAL OPERATION Your SmartLink unit will normally look like this: The MAINS ON Light should be ON and the CANCEL (GREEN) BUTTON will FLASH every 4 seconds. 4 TO CALL FOR HELP You can make your SmartLink Call for Help by either: Pressing the HELP (RED) BUTTON on the SmartLink unit. 2 The HELP (RED) BUTTON will FLASH rapidly and the SmartLink unit will start beeping. This is a Pre-Alarm warning, while this is sounding you can Cancel the Help alarm by pressing the CANCEL (GREEN) BUTTON on the SmartLink unit. OR Pressing the Large HELP (Panic) BUTTON on your Wristwatch/ Pendant for 2 Seconds 1 OR Pressing the Front or Side Lever HELP (Panic) Button(s) on your Box Style Pendant for 2 Seconds. 3 If the CANCEL (GREEN) BUTTON is not pressed within the pre-alarm time (0-60 seconds), then your SmartLink unit will dial your Control Centre using the telephone line. (NOTE: Your SmartLink unit will cut off your telephone for the duration of the call to ensure that there is no interference to the call, this will normally take about 15 seconds). When your Control Centre has received the Help Call, your SmartLink unit will beep 7 times to let you know that the call has been received. The HELP (RED) BUTTON will now FLASH slowly every 4 seconds to indicate that your SmartLink unit has called for Help. 5 SPECIAL FUNCTIONS Your SmartLink unit may have been programmed with one or more special features by your installer, these are described below, check with your Monitoring Company if you have any queries about these or other features. OVER DUE TIMER (PILL TIMER) Your SmartLink unit can be programmed to produce regular warning beeps such as a Medication reminder. When the Over Due Timer is active it will be pre-set by your Installer to provide warning beeps and flash the HELP (RED) BUTTON for 10 minutes as a reminder to take your Medication. You can stop the warning by pressing the CANCEL (GREEN) BUTTON while the warning is happening. NOTE: There is no Help message sent to your Control Centre, the warning is a reminder for you only. If you do not press the CANCEL (GREEN) BUTTON while the warning is sounding (10 minutes) the Over Due Timer will de-activate and it will not re-start until the CANCEL (GREEN) BUTTON is pressed again. You can use this as a useful feature if you wish to change the timer to commence at a different time. For example simply press the CANCEL (GREEN) BUTTON at 4pm to have the Over Due Timer warning sound every day at 4 o’clock in the afternoon. If you wish to change the timer to a different interval e.g. every week, then your Control Centre may be able to change this time over the phone or your Installer can change it for you. INACTIVITY MONITOR Your SmartLink unit may have been programmed by your Installer to ensure that you have not had an accident and are unable to move and you do not have a Pendant with you to call for Help. The Inactivity Monitor, after a fixed period of time without any activity, will automatically send a Help message to your Control Centre. The SmartLink unit will produce warning beeps and flash the HELP (RED) BUTTON. 6 DISPLAYS AND WARNINGS HELP (RED) BUTTON FLASHING QUICKLY WHILE BEEPING Your SmartLink unit is about to send a Help message to your Control Centre. HELP (RED) BUTTON FLASHING SLOWLY Your SmartLink unit has sent a Help message to your Control Centre and is waiting to send the I’m O.K message. The CANCEL (GREEN) BUTTON will need to be pressed to send the I’m O.K message. FAULT DISPLAYS MAINS ON LIGHT FLASHING AC Power Fail – Check and make sure that the MAINS Power Pack is plugged in and turned ON at the Power Point. BATTERY LOW LIGHT FLASHING Power has been off for too long and Battery is Low or Faulty. Contact your Installer or Control Centre. TO IS ON THE DISPLAY Pendant Low Battery – Contact your Installer or Control Centre. TO IS ON THE DISPLAY Detector Low Battery - Contact your Installer or Control Centre. IS ON THE DISPLAY The SmartLink unit failed to send a message to your Control Centre – Check and make sure that the telephone lead is plugged in and all normal telephones are working. IS ON THE DISPLAY The telephone line has failed – Check and make sure that the telephone lead is plugged in and all normal telephones are working. (SmartLink unit will also beep for 25 seconds). Part No. 890-293-2 7 SPECIFICATIONS WARNING: For safety reasons, only connect equipment with a telecommunications compl…
Text truncated - open the document above for the full version.
Top View Bottom View Side View
PL-ABS IPT8003 (AL MOND) LASER MARKED MODEL SW1B315 9 8 7 6 DEF 4 3 2 1 ECNSIG Drn: Title Ckd: Appd: Date: NESS SECURITY PRODUCTS DEF SHEET 1 of 1 Part No.Rev. C 6 7 8 9 A BC 1 2 3 4 55 AB FCC ID: 02K-1B315 IC: XXXXXXXXXX MATERIAL: COLOUR: TEXT: 217-02EWC 0-165-299 PLASTICBASEWRISTWATCH315MHz 15-10-2002 1 E.CIRCOSTA
Label Location FCC Label Location
Cover Open PCB Top PCB Bottom with Battery PCB Bottom without Battery
Document 7258-01, Rev. 0 FCC ID: 02K-1B315 FCC Certification Test Report Washington Laboratories, Ltd February 2003 FCC Certification Test Report for Ness Security Products Pty Ltd FCC ID: 02K-1B315 February 28, 2003 Prepared for: Ness Security Products Pty Ltd 4/167 Prospect Highway Seven Hills, NSW 2147 Australia Prepared By: Washington Laboratories, Ltd. 7560 Lindbergh Drive Gaithersburg, Maryland 20879 FCC Certification Test Report Document 7258-01, Rev. 0 FCC ID: 02K-1B315 FCC Certification Test Report Washington Laboratories, Ltd February 2003 FCC Certification Test Program FCC Certification Test Report for the Ness Security Products Pty Ltd SmartLink™ Medi-Call Radio Key Pendant FCC ID:02K-1B315 February 28, 2003 WLL JOB# 7258 Prepared by: Brian J. Dettling Documentation Specialist Reviewed by: Gregory M. Snyder Wireless/Telco Service Manager & Chief EMC Engineer Document 7258-01, Rev. 0 FCC ID: 02K-1B315 FCC Certification Test Report Washington Laboratories, Ltd February 2003 ii Abstract This report has been prepared on behalf of Ness Security Products Pty Ltd to support the attached Application for Equipment Authorization. The test report and application are submitted for a Periodic Intentional Radiator under Part 15.231 of the FCC Rules and Regulations. This Federal Communication Commission (FCC) Certification Test Report documents the test configuration and test results for a Ness Security Products Pty Ltd SmartLink™ Medi-Call Radio Key Pendant. Testing was performed on an Open Area Test Site (OATS) of Washington Laboratories, Ltd, 7560 Lindbergh Drive, Gaithersburg, MD 20879. Site description and site attenuation data have been placed on file with the FCC's Sampling and Measurements Branch at the FCC laboratory in Columbia, MD. Washington Laboratories, Ltd. has been accepted by the FCC and approved by NIST NVLAP (NVLAP Lab Code: 200066-0) as an independent FCC test laboratory. The Ness Security Products Pty Ltd SmartLink™ Medi-Call Radio Key Pendant complies with the limits for a Periodic Intentional Radiator device under Part 15.231 of the FCC Rules and Regulations. Document 7258-01, Rev. 0 FCC ID: 02K-1B315 FCC Certification Test Report Washington Laboratories, Ltd February 2003 iii Table of Contents Abstract......................................................................................................ii 1 Introduction...............................................................................................................1 1.1 Compliance Statement..........................................................................................1 1.2 Test Scope..........................................................................................................1 1.3 Contract Information............................................................................................1 1.4 Test Dates...........................................................................................................1 1.5 Test and Support Personnel..................................................................................1 1.6 Abbreviations.......................................................................................................2 2 Equipment Under Test................................................................................................3 2.1 EUT Identification & Description..........................................................................3 2.2 Test Configuration................................................................................................3 2.3 Testing Algorithm.................................................................................................3 2.4 Test Location.......................................................................................................4 2.5 Measurements......................................................................................................4 2.5.1 References...................................................................................................4 2.6 Measurement Uncertainty.....................................................................................4 3 Test Equipment..........................................................................................................5 4 Test Results...............................................................................................................6 4.1 Duty Cycle Correction.........................................................................................6 4.2 RF Power Output: (FCC Part §2.1046).............................................................10 4.3 Modulation Characteristics: (FCC Part §2.1047); Audio Frequency Response....10 4.4 Occupied Bandwidth: (FCC Part §2.1049)........................................................10 4.5 Radiated Spurious Emissions: (FCC Part §2.1053).............................................12 4.5.1 Test Procedure........................................................................................12 4.6 Frequency Stability: (FCC Part §2.1055)...........................................................17 Document 7258-01, Rev. 0 FCC ID: 02K-1B315 FCC Certification Test Report Washington Laboratories, Ltd February 2003 iv List of Tables Table 1. Device Summary....................................................................................................3 Table 2: Test Equipment List...............................................................................................5 Table 3. Duty Cycle Correction..........................................................................................10 Table 4. Occupied Bandwidth Results................................................................................12 Table 5. Radiated Spurious Emissions Limits.......................................................................12 Table 6: Radiated Emission Test Data................................................................................14 List of Figures …
Text truncated - open the document above for the full version.
Radiated Emissions Test Set-up
7560 Lindbergh Drive · Gaithersburg, Maryland · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 315 MHz - 315 MHz | - |

Universal Pendant KeyFob
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Smartfall Blue Pendant
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Medi-Minder Guardian
Equipment Class
PCB - PCS Licensed Transmitter
PENDANT TRANSMITTER
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Security Control with GSM Cellular
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver