December 2000 APREL Project No.: Consulting * Research * Training * Certification Testing Since 1981 FCC ID: O2SNURIT3010RT Exhibit 9 User’s Manual 082-32-001 NURIT /3010 User Manual1 NURIT 3010 POS/EDC TERMINAL USER MANUAL NURIT 3010 POS/EDC TERMINAL USER MANUAL NOTICEThe information contained in this publication is for informational purposes only and subject to change without notice. It does not represent a commitment on the part of Lipman USA Inc. or Lipman Electronic Engineering Ltd. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated to any language in any form by any means without the prior written permission of Lipman. Copyright © 1999 by Lipman Electronic Engineering Ltd. All rights reserved. TRADEMARKSTrademarks and trade names contained in this manual belong to their respective companies. LIPMAN USA INC.January 1999 50 Gordon DriveOriginal Syosset, NY 11791Publication No. 082-32-001 Tel: (1) 516-484-9898 Fax: (1) 516-484-9057 E-mail: [email protected] 082-32-001 WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC compliance statement This equipment has been tested to be found to comply with the limits for class A digital device, pursuant to Part 15 of the FCC Rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Class A limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult your dealer or an experienced technician for help. FCC requirements The Federal Communications Commission (FCC) has established rules permitting this device to be directly connected to the telephone network. Standardized jacks are used for these connections. This equipment should not be used on party or coin lines. If this devise is malfunctioning, it may be causing harm to the telephone network; this devise should be disconnected until the source of the problem can be determined and until repair has been made. If this is not done, the telephone company may temporarily disconnect service. The telephone company may make changes in its technical operations and procedures; if such changes affect the compatibility or use of this devise, the telephone company is required to give adequate notice of the changes. You will be advised to file a complaint with the FCC. If the telephone company requests information on what equipment is connected to their lines, inform them of: One. The telephone number this unit is connected to Two. The ringer equivalence number: 0.3B Three. The USOC jack required: RJ-11C Four. The FCC Registration number: 3D7ISR-25066-DT-E The Ringer Equivalence Number (REN) is used to determine how many devices can be connected to your telephone line. In most areas, the sum of the RENs of all devices on any one line should not exceed five (5). If too many devices are attached, they may not ring properly. FCC Part 15 Requirements Notice • This device must not be installed on coin-operated telephone lines or party lines. • This device (equipment) complies with the requirements in Part 15 of FCC Rules of a Class B computing device. Operation of this device (equipment) is subject to the following two conditions: o This device (equipment) may not cause harmful interference, and o This device (equipment) must accept any interference received, including interference that may cause undesired operation. • If this device (equipment) is used in a residential area, it may cause unacceptable interference to radio and TV reception requiring the operator to take whatever steps necessary to correct the interference. • Repair work on this device (equipment) must by done by Lipman USA, Inc, or an authorized repair station. 082-32-001 LIPMAN USA - NURIT /3010 Limited Warranty Lipman USA Inc. will repair this product with new or rebuilt parts, free of charge, in the U.S.A. for one (1) year from the date of original purchase in the event of a defect in materials or workmanship. Carry-in or mail-in service in the continental U.S.A. can be obtained during the warranty period from our N.Y. Service Center or call 1-800-4-LIPMAN toll free. In New York State call (516) 484-9898. This warranty is extended only to the original purchaser. A purchase receipt or other proof of date of original purchase will be required in order to exercise your rights under this warranty. This warranty only covers failures due to defects in materials or workmanship which occur during normal use. It does not cover damage which occurs in shipment; failures which are caused by products not supplied by Lipman USA; or failures which result from accident, misuse, abuse, neglect, mishandling, misapplication, alteration or modification; service by anyone other than the Lipman USA Service Center or accredited service centers, or damage that is attributable to acts of God. Limits and Exclusions There are no express warranties except as listed above. LIPMAN USA SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQ…
Text truncated - open the document above for the full version.
December 2000 APREL Project No.: Consulting * Research * Training * Certification Testing Since 1981 FCC ID: O2SNURIT3010RT Exhibit 10 Attestation Statements FCC Part 15, Subpart B Certificate of Conformity FCC Part 2 & 22 Declaration of Compliance October 2000 APREL Project No.: Consulting * Research * Training * Certification Testing Since 1981 FCC ID: O2SNURIT3010RT PRODUCT: Point of Sale Device MODEL: Nurit 3010 with TNC Carrrent Antenna MANUFACTURER: Lipman USA, Inc. We certify that the pertinent tests have been performed on the above described equipment and that this equipment conforms FCC Parts 2 and 22. See Exhibit 2, Engineering Reports, of this application.
December 2000 APREL Project No.: Consulting * Research * Training * Certification Testing Since 1981 FCC ID: O2SNURIT3010RT Table of Contents List of Exhibits Submitted E E X X H H I I B B I I T T 1 1 : : C C O O V V E E R R L L E E T T T T E E R R S S a)Application overview b)Equipment: Point of Sale Device(Using an approved radio transmitter FCC ID:L6AR902M-2-0) c)Authorization Letter /Agent Designated (Jay Sarkar) d)Request for confidentiality e)Letter from Research In Motion authorizing to use FCC approved (FCC ID L6AR902M-2-0) radio transmitter in Lipman USA, Inc.’s NURIT 3010 with TNC Carrent Antenna Exhibit 2:Engineering Reports (Test Reports) a)ERP (2.1046) b)Radiated Spurious Emissions (2.1053) c)Bandwidth (2.1049) Bandwidth Limitations (2.1047) d)Spurious Emissions, Antenna Terminal (2.1051) e)Frequency Stability (2.1055) Exhibit 3: Operational/Technical Description Exhibit 4: ID Label/Location Exhibit 5:External Photographs of the Equipment Internal Photographs of the equipment Exhibit 6:Block Diagram (Confidential) Exhibit 7: Schematic Diagram (Confidential) Exhibit 8:Parts List (Confidential), Tune–up Procedure Exhibit 9:User’s Manual Exhibit 10:a) Attestation Statement: FCC Part 15 Declaration of Conformance (DoC) certificate b)Attestation Statement: the equipment complies with Part 22 (see page 2 of Users’ Manual) Exhibit 11:RF Exposure Information: SAR Report (Includes Test Set-up Photographs)
December 2000 APREL Project No.: Consulting * Research * Training * Certification Testing Since 1981 FCC ID: O2SNURIT3010RT Exhibit 1 a)Application overview b)Equipment: Rugged handheld computer with integrated wireless communications(Using an approved radio modem FCC ID: L6AR902M-2-0) c)Authorization Letter /Agent Designated (Jay Sarkar) d)Request for confidentiality e)Letter from Research In Motion authorizing to use FCC approved (FCC ID L6AR902M-2-0) radio Transmitter in Lipman USA, Inc.’s NURIT 3010 with TNC Carrent Antenna October 2000 APREL Project No.: Consulting * Research * Training * Certification Testing Since 1981 EQUIPMENT PRODUCT: Point of Sale Device using an FCC approved radio transmitter MODEL: Nurit 3010 with TNC Carrent Antenna MANUFACTURER: Lipman USA, Inc. FCC ID: O2SNURIT3010RT PRODUCT: Point of Sale Device with FCC approved radio transmitter (FCC ID:L6AR902M-2-0) MODEL: Nurit 3010 with TNC Carrent Antenna EUT TYPE: Licensed Non-Broadcast Station Transmitter (TNB) TX Frequency: 896-902 MHz MEASURED ERP:2.239 W
December 2000 APREL Project No.: Consulting * Research * Training * Certification Testing Since 1981 FCC ID: O2SNURIT3010RT Exhibit 5 Photographs of the Equipment Internal Photos
December 2000 APREL Project No.: Consulting * Research * Training * Certification Testing Since 1981 FCC ID: O2SNURIT3010RT Exhibit 4 FCC ID Label/Location NOTICE This device complies with Part 15 of FCC Rules. Operation is subject to the following two conditions: (1) this device may cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Lip Lipman USA, Incorporated P/N: 3010-US-02-GRY-A04 MODEL: NURIT 3010 RIM FCC ID: O2SNURIT3010RT MOBITEX ESN: 031/02/107719 Assembled in Israel
December 2000 APREL Project No.: Consulting * Research * Training * Certification Testing Since 1981 FCC ID: O2SNURIT3010RT Exhibit 11 RF Exposure Information Sar Report This report shall not be reproduced, except in full, without the express written permission of APREL Laboratories 51 Spectrum Way Nepean ON K2R 1E6 Tel: (613) 820-2730 Fax: (613) 820-4161 email: [email protected] Certification Report on Specific Absorption Rate (SAR) Experimental Analysis Lipman USA Inc. Nurit 3010 with a RIM R902-M-2-0 modem and a TNC Carrant Antenna Wireless POS EDC Terminal Test Date: 1 December, 2000 LPMB-Nurit 3010 POS-3618 A0C1-Nurit 3010 Page 2 of 17 Project #: LPMB-Nurit 3010 POS-3618 51 Spectrum WayTel. (613) 820-2730 Nepean, Ontario, K2R 1E6 Fax (613) 820 4161 e-mail: [email protected] © APREL 2000 This report shall not be reproduced, except in full, without the express written approval of APREL Laboratories. FCC ID:02SNURIT3010RT Applicant:Lipman USA Inc. Equipment:Wireless POS EDC Terminal Model:Nurit 3010 with a RIM R902-M-2-0 modem and a TNC Carrant Antenna Standard:FCC 96 –326, Guidelines for Evaluating the Environmental Effects of Radio- Frequency Radiation ENGINEERING SUMMARY This report contains the results of the engineering evaluation performed on a Lipman Nurit 3010 EDC point of sale terminal which incorporates a RIM Mobitex R902M-2-0 modem. The measurements were carried out in accordance with FCC 96-326. The wireless desktop device was evaluated for its maximum power level (ERP 2.239 W). The duty factor of the radio modem is intrinsically restricted to 25% (See Appendix E). The wireless desktop device was tested at low, middle and high channels for the left, right, and keyboard up sides, with the antenna at the 0, 90, and 180 degree positions. The maximum 10g SAR (0.56 W/kg) was found to coincide with the peak performance RF output power of channel 0720 (middle, 899 MHz) for the left side of the device, with the antenna in the 90 degree position. (The hot spot is located on the antenna). At a separation distance of 0 cm from the antenna of the device, the maximum 1g SAR is 0.99 W/kg. Test data and graphs are presented in this report. Based on the test results and on how the device will be marketed and used, it is certified that the product meets the requirements as set forth in the above specifications, for uncontrolled RF exposure environment. (The results presented in this report relate only to the sample tested.) Page 3 of 17 Project #: LPMB-Nurit 3010 POS-3618 51 Spectrum WayTel. (613) 820-2730 Nepean, Ontario, K2R 1E6 Fax (613) 820 4161 e-mail: [email protected] © APREL 2000 This report shall not be reproduced, except in full, without the express written approval of APREL Laboratories. TABLE OF CONTENTS 1.Introduction...................................................................................................................4 2.Applicable Documents..................................................................................................4 3.Device Under Investigation...........................................................................................4 4.Test Equipment..............................................................................................................5 5.Test Methodology..........................................................................................................5 5.Test Results....................................................................................................................6 5.1.Transmitter Characteristics............................................................................................6 5.2.SAR Measurements.......................................................................................................7 6.User’s Hand Exposure...................................................................................................8 7.Bystander Exposure......................................................................................................9 8.Conclusions.................................................................................................................10 APPENDIX A. Measurement Setup, Tissue Properties and SAR Graphs.............................11 APPENDIX B. Uncertainty Budget........................................................................................13 APPENDIX C. Validation Scan on a Flat Phantom...............................................................14 APPENDIX D. Probe Calibration...........................................................................................15 APPENDIX E. Duty Factor Limiting Algorithm for the OEM Radio Module R902M-2-O.16 TABLES AND FIGURES Table 1. Sampled Conducted RF Power..................................................................................6 Table 2. SAR Measurements...................................................................................................8 Figure 1. Setup........................................................................................................................11 Table 3. Dielectric Properties of the Simulated muscle Tissue at 899 MHz.........................11 Figure 2. Surface Plot of the Area Scan 2.5mm Above Phantom Surface.............................12 Figure 3. Contour Plot of the Area Scan 2.5mm Above Phantom Surface............................12 Table 4. Uncertainty Budget..................................................................................................13 Figure 4. Contour Plot of the Reference Area Scan 2.5mm Above Phantom........................14 Figure 5. Surface Plot of the Reference Area Scan 2.5mm Above Phantom.........................14 Page 4 of 17 Project #: LPMB-Nurit 3010 POS-3618 51 Spectrum WayTel. (613) 820-2730 Nepean, Ontario, K2R 1E6 Fax (613) 820 4161 e-mail: [email protected] © APREL 2000 This report shall not be reproduced, except in full, without the express written approval of APREL Laboratories. 1. INTRODUCTION Tests were cond…
Text truncated - open the document above for the full version.
December 2000 APREL Project No.: Consulting * Research * Training * Certification Testing Since 1981 FCC ID: O2SNURIT3010RT Exhibit 2 Engineering Report a)ERP (2.1046) Assessment of Compliance for Measurement of Effective radiated Power (ERP) in Accordance with the FCC Rules & Regulations Part 2.1046 Point of Sale Device Nurit 3010 with a Research In Motion R902-M-2-0 radio transmitter and TNC Carrant Antenna Lipman USA, Inc. 51 Spectrum Way Nepean ON K2R 1E6 Tel: (613) 820-2730 Fax: (613) 820-4161 email: [email protected] December 2000 LPMB-NURIT3010-POS-3619 This report shall not be reproduced, except in full, without the express written approval of APREL Laboratories December, 2000 Page 2 APREL Project No: LPMB-NURIT3010 POS 3619 This report shall not be reproduced, except in full, without the express written approval of APREL Inc. Consulting * Research * Training * Certification Testing Since 1981 FCC ID:O2SNURIT3010RT Applicant:Lipman USA, Inc. Equipment:Point of Sale Device Model:Nurit 3010 with a Research in Motion R902-M-2-0 Mobitex radio transmitter and with TNC Carrant Antenna Standard:FCC Rules and Regulations Part 2.1046 and 90 ENGINEERING SUMMARY This report contains the results of the effective radiated power (ERP) measurement performed on a LIPMAN Point of Sale Device operating with a built-in Research in Motion R902M-2-0 MOBITEX radio transmitter and equipped with a TNC Carrant Antenna. The measurements were carried out in accordance with the FCC Rules and Regulations Part 2.1046 and 90. The product was evaluated for ERP when it was set at the maximum power level. Nurit 3010 was tested for ERP at high, middle, and low frequencies with the maximum ERP obtained at channel No.: 720 with the frequency being 899.00 MHz. The test data is presented in this report under the section: Test Results. The measured ERP is 2.239 W (The results presented in this report relate only to the sample tested.) December, 2000 Page 3 APREL Project No: LPMB-NURIT3010 POS 3619 This report shall not be reproduced, except in full, without the express written approval of APREL Inc. Consulting * Research * Training * Certification Testing Since 1981 Summary of the Results Test DescriptionPage No. Test Set-up Figure No. Results Summary RF Power Output as Radiated Ref. Paragraph 2.1046 and 9081 Passed December, 2000 Page 4 APREL Project No: LPMB-NURIT3010 POS 3619 This report shall not be reproduced, except in full, without the express written approval of APREL Inc. Consulting * Research * Training * Certification Testing Since 1981 INTRODUCTION General This report describes the results of the effective radiated power (ERP) measurement conducted on a Lipman USA Point of Sale Device model Nurit 3010 operating with a built-in Research in Motion R902M-2-0 MOBITEX radio transmitter and equipped with a TNC Carrant Antenna. Test Facility The tests were performed for Lipman USA, Inc. by APREL Laboratories at APREL’s EMI facility located in Nepean, Ontario, Canada. The laboratory operates an (3m and 10m) Open Area Test Site (OATS). The measurement facility is calibrated in accordance with ANSI C63.4-1992. A description of the measurement facility in accordance with the radiated and AC line conducted test site criteria per ANSI C63.4-1992 is on file with the Federal Communications Commission and is in compliance with the requirements of Section 2.948 of the Commissions rules and regulations. APREL’s registration number is: 90416 APREL is accredited by Standard Council of Canada, under PALCAN program (ISO Guide 25). APREL is also accredited by Industry Canada (formerly DOC) and recognised by the Federal Communications Commissions (FCC). Standard The evaluation and analysis were conducted in accordance with FCC Rules and Regulations Parts 2.1046 and the appropriate limits. Test Equipment The test equipment used during the evaluation is listed in Appendix A with calibration due dates. Environmental Conditions Measurements were conducted in open area test site. - Temperature:15 °C ± 2 - Relative Humidity:30 - 50 % - Air Pressure:101 kPa ± 3 December, 2000 Page 5 APREL Project No: LPMB-NURIT3010 POS 3619 This report shall not be reproduced, except in full, without the express written approval of APREL Inc. Consulting * Research * Training * Certification Testing Since 1981 FCC SUBMISSION INFORMATION FCC ID:O2SNURIT3010RT Equipment:Point of Sale Device Model:Nurit 3010 with a Research in Motion R902-M-2-0 Mobitex radio transmitter and w ith TNC Carrant Antenna For:Certification Applicant:Lipman USA, Inc. 50 Gordon Drive Syosset, NY 11791 U.S.A. Manufacturer: Lipman USA, Inc. 50 Gordon Drive Syosset, NY 11791 U.S.A. Evaluated by:APREL Laboratories 51 Spectrum Way Nepean, Ontario Canada K2R 1E6 December, 2000 Page 6 APREL Project No: LPMB-NURIT3010 POS 3619 This report shall not be reproduced, except in full, without the express written approval of APREL Inc. Consulting * Research * Training * Certification Testing Since 1981 Test:RF Power Output as Radiated (ERP) Ref.:FCC Part 2 paragraph 2.1046 Criteria:N/A Set-up:See Figure No. 1. Equipment:See Appendix A. Methodology:RF Power Measurement by Radiated Method (ERP): Test site: The radiated RF power measurement was taken at APREL Laboratory’s open area test site (OATS). This open area test site is calibrated to ANSI C63.4 document and a description of the measurement facility is on file with the Federal Communications Commission and is in compliance with the requirement of Section 2.948 of the Commissions rules and regulations. (FCC File No.: 90416) The test was set-up as illustrated in Fig.1. The Point of Sale Device was configured to operate at maximum power with carrier unmodulated. The equipment under test was placed on a turntable positioned 3 m away from the calibrated receiving antenna, which in turn was connected to the spectrum analyzer. For each transmitter frequency, the received signal was maximised by rotating the turntable and adjusting the height o…
Text truncated - open the document above for the full version.
December 2000 APREL Project No.: Consulting * Research * Training * Certification Testing Since 1981 FCC ID: O2SNURIT3010RT Exhibit 2 Engineering Reports b)Radiated Spurious Emissions (2.1053) Assessment of Compliance for Measurement of Field Strength of Spurious Radiation in Accordance with the FCC Rules & Regulations Part 2.1053 Point of Sale Device Nurit 3010 with a Research In Motion R902-M-2-0 radio transmitter and TNC Carrant Antenna Lipman USA, Inc. 51 Spectrum Way Nepean ON K2R 1E6 Tel: (613) 820-2730 Fax: (613) 820-4161 email: [email protected] December 2000 LPMB-NURIT3010-POS-3620 This report shall not be reproduced, except in full, without the express written approval of APREL Laboratories December, 2000 Page 2 APREL Project No. LPMB-NURIT3010 POS-3620 This report shall not be reproduced, except in full, without the express written approval of APREL Laboratories Consulting * Research * Training * Certification Testing Since 1981 FCC ID:O2SNURIT3010RT Applicant:Lipman USA, Inc. Equipment:Point of Sale Device Model:Nurit 3010 with a Research in Motion R902-M-2-0 Mobitex radio transmitter and with TNC Carrant Antenna Standard:FCC Rules and Regulations Part 2.1053 and 90 ENGINEERING SUMMARY This report contains the results of Field Strength of Spurious Radiation measurement performed on a LIPMAN Point of Sale Device operating with a built-in Research in Motion R902M-2-0 MOBITEX radio transmitter and equipped with a TNC Carrant Antenna. The measurements were carried out in accordance with the FCC Rules and Regulations Part 2.1053 and 90. The product was evaluated for spurious when it was set at the maximum power level. (The results presented in this report relate only to the sample tested.) December, 2000 Page 3 APREL Project No. LPMB-NURIT3010 POS-3620 This report shall not be reproduced, except in full, without the express written approval of APREL Laboratories Consulting * Research * Training * Certification Testing Since 1981 Summary of the Results Test DescriptionPage No. Test Set-up Figure No. Results Summary Field Strength of Spurious Radiation Ref. Paragraph 2.1053 and 9081 Passed December, 2000 Page 4 APREL Project No. LPMB-NURIT3010 POS-3620 This report shall not be reproduced, except in full, without the express written approval of APREL Laboratories Consulting * Research * Training * Certification Testing Since 1981 INTRODUCTION General This report describes the results of the Field Strength of Spurious Radiation measurement conducted on a Lipman USA Point of Sale Device model Nurit 3010 operating with a built-in Research in Motion R902M-2-0 MOBITEX radio transmitter and equipped with a TNC Carrant Antenna. Test Facility The tests were performed for Lipman USA, Inc. by APREL Laboratories at APREL’s EMI facility located in Nepean, Ontario, Canada. The laboratory operates an (3m and 10m) Open Area Test Site (OATS). The measurement facility is calibrated in accordance with ANSI C63.4-1992. A description of the measurement facility in accordance with the radiated and AC line conducted test site criteria per ANSI C63.4-1992 is on file with the Federal Communications Commission and is in compliance with the requirements of Section 2.948 of the Commissions rules and regulations. APREL’s registration number is 90416 APREL is accredited by Standard Council of Canada, under PALCAN program (ISO Guide 25). APREL is also accredited by Industry Canada (formerly DOC) and recognised by the Federal Communications Commissions (FCC). Standard The evaluation and analysis were conducted in accordance with FCC Rules and Regulations Parts 2.1053 and the appropriate limits. Test Equipment The test equipment used during the evaluation is listed in Appendix A with calibration due dates. Environmental Conditions Measurements were conducted in open area test site. - Temperature:24 °C ± 2 - Relative Humidity:30 - 50 % - Air Pressure:101 kPa ± 3 December, 2000 Page 5 APREL Project No. LPMB-NURIT3010 POS-3620 This report shall not be reproduced, except in full, without the express written approval of APREL Laboratories Consulting * Research * Training * Certification Testing Since 1981 FCC SUBMISSION INFORMATION FCC ID:O2SNURIT3010RT Equipment:Point of Sale Device Mode:Nurit 3010 with a Research in Motion R902-M-2-0 Mobitex radio transmitter and with TNC Carrant Antenna For:Certification Applicant:Lipman USA, Inc. 50 Gordon Drive Syosset, NY 11791 U.S.A. Manufacturer: Lipman USA, Inc. 50 Gordon Drive Syosset, NY 11791 U.S.A. Evaluated by:APREL Laboratories 51 Spectrum Way Nepean, Ontario Canada K2R 1E6 December, 2000 Page 6 APREL Project No. LPMB-NURIT3010 POS-3620 This report shall not be reproduced, except in full, without the express written approval of APREL Laboratories Consulting * Research * Training * Certification Testing Since 1981 L L i i p p m m a a n n U U S S A A , , I I n n c c . . TEST RESULTS FOR Field Strength of Spurious Radiation Of Point of Sale Device Nurit 3010 MOBITEX (TNC) And With TNC Carrant Antenna December, 2000 Page 7 APREL Project No. LPMB-NURIT3010 POS-3620 This report shall not be reproduced, except in full, without the express written approval of APREL Laboratories Consulting * Research * Training * Certification Testing Since 1981 Test:Field Strength of Spurious Radiation Ref:FCC Parts 2.1046 and 90 Criteria:Emission : The permitted maximum level of spurious emission is 50 + 10 log (P) dB below the unmodulated carrier power of the transmitter (P). Set-up:See Figure 1.a Conditions:Voltage Supply: 7.4/8.4 DC Battery Equipment:See Appendix A. Procedure:The final measurements were taken at APREL Laboratory’s open area test site (OATS) measurement facility. This open area test site is calibrated to ANSI C63.4 document and a description of the measurement facility is on file with the Federal Communications Commission and is in compliance with the requirements of Section 2.948 of the Commissions rules and regulations. (FCC Registration No.:90416). The Point of Sa…
Text truncated - open the document above for the full version.
December 2000 APREL Project No.: Consulting * Research * Training * Certification Testing Since 1981 FCC ID: O2SNURIT3010RT Exhibit 2 Engineering Report c)Bandwidth (2.1049) Bandwidth Limitations (2.1047) RESEARCH IN MOTION Document R902M-2-O RADIO MODEM DEVICE OCCUPIED BANDWIDTH/BANDWIDTH LIMITATIONS Page 1(4) Author Data Masud S. Attayi Date April 8, 1999 Document No. 01947-CERT-FCC-TEST-BW_MASK ApprovedRevFile / Reference BW_MASK Copyright 1999, Research In Motion, Limited OCCUPIED BANDWIDTH/BANDWIDTH LIMITATIONS TEST PROCEDURE: The Research In Motion Limited R902M-2-O radio modem device was connected together with a radio monitor board 02120-001, host computer, external power supply, a 20 dB external attenuator, and a coaxial cable. The R902M-2-O antenna output terminal was connected to the input of a 50 : spectrum analyzer through a matched 20 dB attenuator and a coaxial cable. The R902M-2-O transmitter was operating at full and low output power with and without internal data modulation. TEST RESULTS: UNMODULATED CARRIER, High Power: 11.97 dBm with a 20 dB external attenuator and a 1 m coaxial cable. a)Internal Modulation: Please refer to the attached spectrum analyzer plots. 100% of the in-band modulation is below the specified mask per 90.210(j) UNMODULATED CARRIER, Low Power: -2.53 dBm with a 20 dB external attenuator and 1 m coaxial cable. b)Internal Modulation: Please refer to the attached spectrum analyzer plots. 100% of the in-band modulation is below the specified mask per 90.210(j) Below is the description of the mask for band 896-901/935-940 MHz (Mobitex) : 2 Watts transmitter Frequency (MHz) FormulaUpper Limit (dB) Lower Limit (dB) -2650050+10 log (P)-53-175 -0.0115 157 log (f d e 5.3) -53-175 -0.0095 157 log (f d e 5.3) or 103 log(f d e 3.9) -39.8-175 -0.0062 103 log (f d e 3.9) or 53 log (f d e 2.5) -21.1-175 -0.0025 53 log (f d e 2.5) 0.0-175 0.0025 53 log (f d e 2.5) 0.0-175 0.0062 103 log (f d e 3.9) or 53 log (f d e 2.5) -21.1-175 Document R902M-2-O RADIO MODEM DEVICE OCCUPIED BANDWIDTH/BANDWIDTH LIMITATIONS Page 2(4) Date Apri…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 1 | 90 | 896 MHz - 901 MHz | 2.03 W | 12K8FID | 1.5000000000 ppm |

Hand held Payment Terminal
Equipment Class
PCB - PCS Licensed Transmitter
PCS Payment Terminal
Equipment Class
PCB - PCS Licensed Transmitter
PCSPayment Terminal
Equipment Class
PCB - PCS Licensed Transmitter
Hand Held Point of Sale Device
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
POINT OF SALE DEVICE
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter