Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
.:WELCOME Congratulations! The FitSense™ FS-1 Speedometer is the world's first accurate pace and distance watch for walking and running with an optional wireless Internet link. The FS-1 measures every stride and reports your speed, pace, distance, and calorie burn. The FS-1 is a fully functional watch and exercise monitor. Its features include: • Time, day, and date • Chronograph • Current Speed and Pace • Average Pace • Distance (activity and total) • Calories • Heart Rate (using optional heart rate monitor) • Training Log • AutoSplitz™ • Pace Zones • Backlight • Wireless Connection to your PC and the Internet (using optional Netlink). GETTING THE MOST OUT OF YOUR FS-1 How can you use your FS-1? The options are limitless. Here are a few suggestions: • Tracking your Runs or Walks • Monitoring your Calorie Burn • Measuring your Courses • Tracking your Fitness • Training with Pace • Automating your Log WATCH FOOT POD NETLINK (OPTIONAL) .:CONTENTS .:BEFORE YOU BEGIN...................................................1 .:FS-1 COMPONENTS.....................................................1 Watch 1 Foot Pod 3 NetLink (Optional) 5 Heart Rate Monitor (Optional) 6 .:QUICK START...............................................................7 Mode Functionality 7 Learning New Sensors 8 Calibrating your FS-1 8 Running and Walking with your FS-1 9 Linking to FitSense Interactive (Using Optional Netlink) 10 Displaying Heart Rate on your FS-1 10 .:USING YOUR FS-1......................................................11 TIME Mode 11 SPED Mode: Speedometer 12 LOG Mode 15 ODOM Mode: Odometer 16 COMM Mode: Communication 17 CALB Mode: Calibration 19 ALARM Mode 22 .:CARE AND MAINTENANCE.......................................23 Replacing Batteries 23 Replacing the Rungee Cord 23 .:SPECIFICATIONS.......................................................24 .:REGULATORY INFORMATION..................................25 .:CUSTOMER SERVICE................................................25 .:LIMITED WARRANTY.................................................26 1 .:BEFORE YOU BEGIN ß Consult your physician prior to beginning or modifying any exercise program. ß DO NOT use the FS-1 heart rate monitor if you have a pace maker. ß DO NOT use FS-1 in an airplane. ß When exercising with FS-1, be aware of your surroundings and exercise safely. Remain alert to vehicles, footing and other potential hazards. .:FS-1 COMPONENTS WATCH The FS-1 watch is the window to your activity. It has a revolutionary side-mounted display. Your activity info is available at a glance without turning your wrist, pressing buttons, or breaking stride. Strap your FS-1 to your wrist with the buttons pointing up from the top of your wrist. 2 WATCH BUTTONS Button functions listed in normal font (MODE, SELECT, LIGHT, SPLIT, START/STOP) are performed by pressing and releasing the button. BUTTON FUNCTIONS MODE Cycles through the seven main modes. If you stay in any mode for more than three seconds, the title screen will disappear and the mode content screen will appear. The next press of the MODE button will return you to TIME mode. SELECT Toggles between "pace display" and "speed display" in SPED mode. Toggles between track and treadmill calibration in CALB mode. Accepts selected values and advances to next field while setting. LIGHT Turns on the light for 3 seconds. Holding LIGHT for 3 seconds turns on Night Mode. In Night Mode, pressing any button will turn on the light for 5 seconds. Holding LIGHT for 3 seconds turns off Night Mode. SPLIT In SPED mode, with the chronograph running, SPLIT freezes the screen and records a manual split in the daily chart. Holding for 3 seconds in TIME mode launches COMM mode. 3 The FS-1 foot pod may be placed on either your right or left foot. The stride characteristics of your right leg may be different from those of your left leg. Always keep the foot pod on the same foot. START Starts and stops the chronograph in SPED mode. /STOP Button functions listed in reverse font (SET , RESET) are performed by pressing and holding the button for 3 seconds. SET Hold SET in TIME mode to change time. Hold SET in SPED mode to set weight, view alert interval and toggle Pace Zones ON and OFF. Hold SET in ALRM mode to change alarm settings. RESET Hold RESET in SPED mode to store activity in your log and clear the display. Hold RESET in SPED mode when the chronograph is zeroed to enter the LOG clear menu. Hold RESET in the LOG clear menu to clear chart data and log data. Hold RESET in ODOM mode to zero the odometer. (+) BUTTON Increments values while setting. (-) BUTTON Decrements values while setting. FOOT POD 4 VIEW FROM ABOVE TOE SIDE VIEW Loosen your shoelaces. Place the rungee cord beneath 2 or 3 lace crossings. Snap the rungee cord into the slot at the front of the pod. Tighten your laces and tie your shoes comfortably. The foot pod should be firmly attached with the narrow end of the pod facing your toe. If the pod is loose, place the cord beneath another lace crossing. The pod may remain attached to your shoe between activities. Also, the cord may be laced into the shoe and remain there for convenience and added security. FOOT POD BUTTONS The foot pod has three states (ON, OFF and COMM LEARN) that are controlled by pressing the rubber button. Unique sounds confirm the state you have entered. PRESSES WHAT THEY DO ONE Turns pod ON. When the pod is off, push and hold the button until you hear a beep. On button release, you will hear a single confirmation beep. The pod is now ready for your activity. When the foot pod is communicating with the watch, the foot icon on the watch display will be lit. TWO Turns pod OFF. Pressing the button twice in quick succession turns the pod off. A descending tone confirms that the foot pod is off. THREE Allows a watch to learn a foot pod ID. Pressing the button three times in quick succession resets the COMM Address. Three beeps confirms that the foot pod is in COMM LEARN mode. Now any FS-1 watch can lear…
Text truncated - open the document above for the full version.
Federal Communications Commission FCC ID: O9DHA 7435 Oakland Mills Road Columbia MD 21046 Gentlemen: This letter is is to comply with Section 0.457(d)(2)(I) pertaining to confidential material. FitSense Technology requests that the following documents regarding this submission for FCC ID O9DHA be kept confidential; 1. Block diagram 2. Schematic 3. Circuit Description 4. Bill of Materials (parts list) The material above contains trade secrets or technical data which would customarily be guarded from competitors. It represents several years of research and development by FitSense Technology and its availability is normally subject to confidentiality and non-disclosure agreements. We respectfully request that these documents not be available to the general public. Sincerely, John Maclean Vice President of Manufacturing FitSense Technology Inc. 212 Worcester St. Wellesley MA 02481
Equipment Photographs External Photos FitSense FS-1 Heart Strap Unit FCC ID: O9DHA FitSense FS-1 Heart Strap Unit FCC ID: O9DHA FitSense FS-1 Heart Strap Unit FCC ID: O9DHA
Page 1 of 1 file://E:\FitSense\B0408\CD given to us\heart-FCCID.jpg4/13/01
Internal Photos FitSense FS-1 Heart Strap Unit FCC ID: O9DHA FitSense FS-1 Heart Strap Unit FCC ID: O9DHA FitSense FS-1 Heart Strap Unit FCC ID: O9DHA
MEASUREMENT/TECHNICAL REPORT Company - Model: FitSense Technology FS-1 Heart Rate Monitor FCC ID: O9DHA June 1, 2001 Description: This is a report to support a request for an original grant of equipment authorization. Equipment Type: Low Power Communications Device Transmitter (DXX) Report prepared for: FitSense Technology 212 Worcester Street Wellesly, MA 02481 Phone: (781) 237-2233 Fax: (781) 237-6669 Report prepared by: Evan D. Gould Curtis-Straus LLC 527 Great Road Littleton, MA 01460 USA Phone: 978-486-8880 FAX: 978-486-8828 FCC Application for FitSense Technology •• FCC ID: O9DHA •• Report No. EB0408-1 1-Jun-01 ______________________________________________________________________ _____________________________________________________________ Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828 page 2 of 13 Introduction This report is an application for Certification of a Transmitter operating pursuant to Part 15.249 of the FCC Rules, Code of Federal Regulations 47. The model number covered by this report is FS-1 Heart Rate Monitor. This report is designed to demonstrate the compliance of this device with the requirements outlined in Part 15 of CFR 47 using the methods outlined in Part 2 of CFR 47. The confidential information and descriptions included in this application are detailed descriptions of the products, block diagrams, component specifications, and schematic diagrams. We hereby respectfully request under the provision of section 0.457d of the code that the documents listed below be held confidential. Technical Descriptions and Block Diagrams Schematics Bill of Materials FitSense is requesting that the Technical Descriptions, Block Diagrams, Schematics and Bill of Materials be kept confidential in the FCC application because of the proprietary design developed by FitSense that is unique to the industry. FCC Application for FitSense Technology •• FCC ID: O9DHA •• Report No. EB0408-1 1-Jun-01 ______________________________________________________________________ _____________________________________________________________ Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828 page 3 of 13 Statement of Conformity The FitSense FS-1 Heart Rate Monitor has been found to conform with the following parts of the 47 CFR as detailed below: Part 2 Part 15 Comments 15.15(b) The product contains no user accessible controls that increase transmission power above allowable levels. 2.925 15.19 The label is shown in the label exhibit. 15.21 Information to the user is shown in the instruction manual exhibit. 15.27 No special accessories are required for compliance. 15.203 The antenna is built into the board and there is no external antenna connection. 15.205 15.209 The fundamental is not in a Restricted band and the spurious and harmonic emissions in the Restricted bands comply with the general emission limits of 15.209. 15.207 The unit is battery powered without the capability of being recharged or operated from the AC mains. 15.249(a) The unit complies with the field strength limits of the 15.249(a) table including the 20dB peak restriction of 15.35(b) and 15.249(d). 15.249(c) The unit complies with the field strength limits of the 15.209(a) table. FCC Application for FitSense Technology •• FCC ID: O9DHA •• Report No. EB0408-1 1-Jun-01 ______________________________________________________________________ _____________________________________________________________ Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828 page 4 of 13 Unit Tested Model Number: FS-1 Heart Rate Monitor FCC Application for FitSense Technology •• FCC ID: O9DHA •• Report No. EB0408-1 1-Jun-01 ______________________________________________________________________ _____________________________________________________________ Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828 page 5 of 13 Test Methodology Radiated emission testing was performed according to the procedures in ANSI C63.4 (1992). Radiated testing was performed at an antenna to EUT distance of 3 meters below 1 GHz, and at a distance of 3 or 1 meter(s) above 1 GHz. The actual test distance used is noted in the test data sheets. The device’s performance was investigated to 10GHz. The EUT was powered by a Maxell CR2032 3VDC battery for all tests. A fresh battery was used for all testing. Since the Heart Rate Monitor can be operated in any orientation, the emissions were maximized in each of the three orthogonal axes and the maximum reading was recorded. The integrated antenna cannot be maximized separately. All other performance tests were made in accordance with the procedures outlined in Part 15 of CFR 47. The applicable sections provided under Part 15 are provided in the measurement section of this report. Discussion of CFR47 Part 15.249 Testing Procedure The FS-1 Heart Rate Monitor is part of a system involving four separate units. The Heart Rate Monitor transmits heart rate data to the FS-1 Watch (a separate part of the FS-1 system). The unit was continuously activated by stimulating the sensors with a simulated heart beat (low voltage repetitive pulse). During the transmission cycle, peak readings were taken. FCC Application for FitSense Technology •• FCC ID: O9DHA •• Report No. EB0408-1 1-Jun-01 ______________________________________________________________________ _____________________________________________________________ Curtis-Straus LLC •• 527 Great Road •• Littleton, MA •• TEL (978) 486-8880 •• FAX (978) 486-8828 page 6 of 13 Test Facility Curtis-Straus LLC All testing for the range 30–10,000MHz was performed at Curtis-Straus (A2LA Certificate Number 1627-01). The open area test site used to collect the radiated data is located at 527 Great Road, Littleton, MA 01460. Site “T” was used. FCC Application for FitSense Technology •• FCC ID: O9DHA •• Report No. EB0408-1 1-Jun…
Text truncated - open the document above for the full version.
Page 1 of 1 file://E:\FitSense\B0408\Heart-Setup Photo.jpg4/13/01
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 916.5 MHz - 916.5 MHz | - |

Bluetooth Activity Sensor
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wireless Access Point
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wireless Activity Monitor
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Alere AirLink for INRatio
Equipment Class
DTS - Digital Transmission System
Wireless Step Sensor/Pedometer
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter