FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

Β© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. G4S Technology Limited/
  3. OE5S854

OE5S854S854 Inductive Reader

G4S Technology Limited
S854 Inductive Reader - FCC ID OE5S854 - G4S Technology Limited
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Dec 27, 2010
Application Purpose
Original Equipment
Date of Application
Dec 27, 2010
Equipment Note
S854 Inductive Reader
Frequency Range
13.55000000 - 13.56000000
Company
G4S Technology Limited
Country
United Kingdom

Documents & Files

Select a file to view

Users Manual

β†—

Attestation Statements

β†—

Cover Letter(s)

β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Installation and User Instructions for S854 Readers You should find that the backplate has holes for connection to most standard electrical backboxes. With the backplate off (see above), mount the backplate adjacent to the opening edge of the door and at a convenient height. Feed the required cables through the backplate: The cable from the controller. The cable from the heater, if used (must be a separate cable). A cable from a Remote Interface Module (RIM), if used. A RIM can reduce cable lengths to door furniture. 2 The optional heater kit maintains the reader at the correct temperature when mounted outside. With the backplate off, remove the backing paper from the two elements, then stick them to the inner sides of the reader. The heaters must be connected to a 24V AC supply (min 25VA). When mounting outside, the two-part gasket kit must be fitted: a)Remove the backplate from the reader by releasing the two securing screws. b)Remove the cutouts and backing paper from the two gaskets, then stick them to the backplate as shown. Outer gasket Inner gasket Backplate securing screws Backplate 1 Fit the Weatherproofing Kit Mount the Backplate Set LK1 (USER FB) to 1 for sound on, or 0 for sound off. Set LK3 (COMMS) across the center and WGD pin for Wiegand communications, or across the center and C/L pin for 20mA current loop communications. 3 Reader Links The S854 is a combined contact and with LCD and keypad. The reader can be set to use Wiegand or p The S854 is able to read Personal Identity Verification (PIV II) type A and B, Philips MIFARE and Philips MIFARE DESfire smart cards. For Philips MIFARE and Philips MIFARE DESfire cards, the S854 supports the use of unencoded cards (where only the unique card serial number is read), or cards encoded with a card number. Several encoding formats are supported. The reader can simultaneously support two different card types/formats (e.g. non-encoded MIFARE and smartMAX-encoded MIFARE DESfire, or non-encoded MIFARE and smartMAX-encoded MIFARE). The reader is automatically configured to accept the first two card types/formats presented after power is applied. contactless smart-card reader, 20mA current loop seudo-random communications. 0VRX+RX-TX+TX-12V Reader Controller 20mA current loop The I/O terminal is for connection to a RIM (see the RIM Instructions). 0V TX+ TX- I/0 RX+ RX- +V GroundData 0Green Data 112V Reader Controller Wiegand 0V 0 GRN 1 +V For a contactless card presentthe cardface-ontothereaderuntilyouhear a"bleep". For a contact card, insert the card (chip upwards and facing you) into the slot at the bottom of the reader until you hear a β€œbleep”. Cards can be presented in rapid succession; there is no need, for example, to wait for "UNLOCKED" to disappear before presenting another. If the reader has been enabled for user-code mode at the controller, you can gain access by pressing the # key, entering your card number, then pressing the * key. A Setup menu can be displayed by pressing the * and # keys simultaneously while power is applied. You can use the menu to change the contrast and language used for the LCD (default English). At the prompts, press 9600-0453. Installation and User Instructions for S854 Readers, Issue 1.0.2 26th November 2010. G4S Technology, 2009. FCC Notice: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any unauthorized modification to this device may void the authority of the user to operate it. All trademarks acknowledged. Β© About the Reader Messages } READY – UNLOCKED – The lock is released and you may open the door. ACCESS DENIED & LOCKED – You do not have access rights to gain entry, or the reader did not read your card properly (in this case, present it again). ENTER PIN – Enter your PIN. If you make a mistake, the message INCORRECT PIN is momentarily displayed, followed by ENTER PIN, to prompt you to try again. CARD PIN AND # – Enter the DESfire card PIN, then press # if the PIN is less than 8 digits. The reader is waiting for a valid card to be presented. (Flashing or steady) – These auxiliary indicators can be configured to operate in conjunction with conditional commands. Specifications Input voltage: 10.2-14Vdc. Input current (excl. heater): 180mA @ nom. 12Vdc. Operating temperature: -4 to 158F (-20 to 70C) without heater. Operating humidity: 15 to 90%, non-condensing. Maximum read range: 3/4" (20mm). °° 5 Using the Reader 4 Reader Connections Note: Use LK3 to select the communications mode (see step 3). Connect shield at controller end only Twisted pairs (use Belden 9503 cable) Connect shield at controller end only. Use Belden 9537 cable Slide the ferrite sleeve onto cable before wiring terminal block. Ferrite to be placed 50mm (2") up cable and held in place with cable ties. Note: The FERRITE must be fitted!

ID Label/Location Info

Serial Label Position 91 mm 1 12 mm

Test Report

Total number of pages: 39 TRaC Wireless Test Report:TTR003012WUS1 Applicant:G4S Technology Ltd. Apparatus:S854 Specification(s):CFR47 Part 15.225 July 2008 Purpose of Test: Certification FCCID: OE5S854 Authorised by: : Radio Product Manager Issue Date:22 nd December 2010 Authorised Copy Number: PDF Radio Test Report: TTR003012WUS1 2 Contents Section 1:Introduction3 1.1General3 1.2Tests Requested By4 1.3Manufacturer4 1.4Apparatus Assessed4 1.5Test Result Summary5 1.6Notes Relating To The Assessment6 1.7Deviations from Test Standards6 Section 2:Measurement Uncertainty7 2.1Measurement Uncertainty Values7 Section 3:Modifications9 3.1Modifications Performed During Assessment9 Appendix A:Formal Emission Test Results10 A1Transmitter Intentional Emission Radiated11 A2Radiated Electric Field Emissions12 A3Power Line Conducted Emissions15 A4Frequency Stability17 Appendix B:Supporting Graphical Data18 Appendix C: Additional Test and Sample Details23 Appendix D:Additional Information29 Appendix E:Photographs and Figures30 Radio Test Report: TTR003012WUS1 3 Section 1:Introduction 1.1General This report contains an assessment of an apparatus against Electromagnetic Compatibility Standards based upontests carried out on samples submitted to the Laboratory. Test performed by:TRaC Telecoms & Radio[ ] Unit E South Orbital Trading Park Hedon Road Hull, HU9 1NJ. United Kingdom. Telephone:+44 (0) 1482 801801 Fax:+44 (0) 1482 801806 TRaC Telecoms & Radio[X] Unit 1 Pendle Place, Skelmersdale, WestLancsWN8 9PN Telephone:+44 (0) 1695 556666 Fax:+44 (0) 1695 577077 Email:[email protected] Web site:http://www.tracglobal.com Tests performed by:Steve Hodgkinson Report author:Steve Hodgkinson This report must not be reproduced except in full without prior written permission from TRaC Telecoms & Radio. Radio Test Report: TTR003012WUS1 4 1.2Tests Requested By This testing in this report was requested by : G4S Technology Ltd. International Division Challenge House International Drive Tewkesbury GL20 8UQ 1.3Manufacturer As above. 1.4Apparatus Assessed The following apparatus was assessed between1st - 3rd November 2010. The S854 is a HF RFID card reader operating on 13.56MHz. Radio Test Report: TTR003012WUS1 5 1.5Test Result Summary Full details of test results are contained within Appendix A. The following table summarises the results of the assessment. The statements relating to compliance with the standards below apply ONLY as qualified in the notes and deviations stated in sections 1.6 to 1.7 of this test report. Full details of test results are contained within Appendix A.The following table summarises the results of the assessment. Test TypeRegulation Measurement standard Result Spurious Emissions Radiated <1000MHz Title 47 of the CFR: Part 15 Subpart (c) 15.225 -15.209 ANSI C63.10Pass Spurious Emissions Radiated >1000MHz Title 47 of the CFR: Part 15 Subpart (c) ANSI C63.10N/A AC Power conducted emissions Title 47 of the CFR: Part 15 Subpart (c) 15.207 ANSI C63.10Pass Intentional Emission Frequency Title 47 of the CFR: Part 15 Subpart (c) 15.255 ANSI C63.10Pass Intentional Emission Field Strength Title 47 of the CFR: Part 15 Subpart (c) 15.225 ANSI C63.10Pass Intentional Emission Band Occupancy Title 47 of the CFR: Part 15 Subpart (c) 15.225 ANSI C63.10Pass Antenna Arrangements Integral: Title 47 of theCFR: Part 15 Subpart (c) 15.203 -Pass Antenna Arrangements External Connector Title 47 of the CFR: Part 15 Subpart (c) 15.204 -Pass Restricted Bands Title 47 of the CFR: Part 15 Subpart (c) 15.205 -Pass Maximum Frequency of Search Title 47 of the CFR: Part 15 Subpart (c) 15.33 -N/A Extrapolation Factor Title 47 of the CFR: Part 15 Subpart (c) 15.31(f) -N/A Abbreviations used in the above table: CFR: Code of Federal RegulationsANSI: American National Standards Institution REFE: Radiated Electric Field EmissionsPLCE: Power Line Conducted Emissions Radio Test Report: TTR003012WUS1 6 1.6Notes Relating To The Assessment With regard to this assessment, the following points should be noted: The results contained in this report relate only to the items tested and were obtained in the period between the date of initial receipt of samples and the date of issue of the report. The apparatus was set up and exercised using the configurations, modes of operation and arrangements defined in this report only. Particular operating modes, apparatus monitoring methods and performance criteria required by the standards tested to have been performed except where identified in Section 1.7 of this test report (Deviations from Test Standards). For emissions testing, throughout this test report, β€œPass” indicates that the results for the sample as tested were below the specified limit (refer also to Section 2, Measurement Uncertainty). Where relevant, the apparatus was only assessed using the monitoring methods and susceptibility criteria defined in this report. All testing with the exception of testing at the Open Area Test Site was performed under the following environmental conditions: Temperature: 17 to 23 ο‚°C Humidity : 45 to 75 % Barometric Pressure: 86 to 106 kPa All dates used in this report are in the format dd/mm/yy. This assessment has been performed in accordance with the requirements of ISO/IEC 17025. 1.7Deviations from Test Standards There were no deviations from the standards tested to. Radio Test Report: TTR003012WUS1 7 Section 2:Measurement Uncertainty 2.1Measurement UncertaintyValues Radio Testing – General Uncertainty Schedule All statements of uncertainty are expanded standard uncertaintyusing a coverage factor of 1.96 to give a 95% confidence where no required test level exists. [1] Adjacent Channel Power Uncertainty in test result = 1.86dB [2] Carrier Power Uncertainty in test result (Equipment - TRLUH120) = 2.18dB Uncertainty in test result (Equipment – TRL05) = 1.08dB Uncertainty in test result (Equipment – TRL479) = 2.48dB [3] Effective Radiated Power Uncertainty in test result = 4.71dB [4] Spurious Emissions Uncertain…

Text truncated - open the document above for the full version.

Contact Information

Applicant

ANDY WATTS(Mr)
[email protected]+44 1684 850977Fax: +44 1684 277308

Test Firm

Element Materials Technology Warwick LtdMax Leach
[email protected]4401482801801Fax: 44 (0) 1482 801 806

Technical Specifications

#Rule PartsFrequency RangePower Output
115C13.55 MHz - 13.56 MHz-
Confidentiality
Long Term

Other Applications from G4S Technology Limited

Proximity card reader with keypad for access control systems - FCC ID OE5S870C - G4S Technology Limited
OE5S870C

Proximity card reader with keypad for access control systems

Dec 22, 2025

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
Access Control Keypad Reader 884 MKII - FCC ID OE5S884C - G4S Technology Limited
OE5S884C

Access Control Keypad Reader 884 MKII

Dec 22, 2025

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Smartcard reader with keypad for access control systems 874 MKII - FCC ID OE5S874C - G4S Technology Limited
OE5S874C

Smartcard reader with keypad for access control systems 874 MKII

Dec 19, 2025

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
S884O Proximity Reader - FCC ID OE5S884O - G4S Technology Limited
OE5S884O

S884O Proximity Reader

Jan 20, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
S680 Proximity Card Reader - FCC ID OE5S680A - G4S Technology Limited
OE5S680A

S680 Proximity Card Reader

Nov 19, 2013

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter