Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Wireless Solutions 48 Mivtza Kadesh St. Bene Beraq 51203 , ISRAEL Tel: +972-3-6175639 Fax:+972-3-6175962 3RIHPDLO [email protected] :HEVLWHZZZPZHOLVUDFRP5HY% INSTALLATION AND OPERATING INSTRUCTIONS FOR MW-CBDA-TDMAB-1W60-A CELLULAR BI-DIRECTIONAL AMPLIFIER Wireless Solutions 48 Mivtza Kadesh St. Bene Beraq 51203 , ISRAEL Tel: +972-3-6175639 Fax:+972-3-6175962 3RIHPDLO [email protected] :HEVLWHZZZPZHOLVUDFRP5HY% TABLE OF CONTENTS PARAGRAPHPAGE No BDA OVERVIEW3 BLOCK DAIGRAM DESCRIPTION3 BDA OPERATION4 AGC & MGC FUNCTION5 RF EXPOSURE WARNING6 ELECTRICAL SPECIFICATIONS7 MECHANICAL SPECIFICATIONS7 ENVIRONMENTAL CONDITIONS7 LIST OF DRAWINGS DRAWINGPAGE No BDA (WITH AGC) RF BLOCK DIAGRAM DRAWING 4 AGC & MGC CONTROL5 MECHANICAL OUTLINE8 Wireless Solutions 48 Mivtza Kadesh St. Bene Beraq 51203 , ISRAEL Tel: +972-3-6175639 Fax:+972-3-6175962 3RIHPDLO [email protected] :HEVLWHZZZPZHOLVUDFRP5HY% BDA OVERVIEW: The Bi-Directional Amplifier (BDA) assembly provides an exceptional repeater/booster performances to extend the coverage area of radio communications in buildings and RF shielded environments. Features such as high linearity power amplifiers are contributing for the overall improved system linearity performances. The unit is based on a duplexed path configuration, having sharp out of band attenuation for improved isolation between the receiving and transmitting paths. BLOCK DIAGRAM DESCRIPTION: The CBDA Downlink path receives the RF signals from base station amplifies them and transmits them to the subscriber. The BDA Uplink path receives the RF signals from the subscriber amplifies them and transmits them to the base station. Two duplexers frequency separate the signals to the proper amplifying path and isolate the two signals. For each path there is an AGC amplifier. The amplifier has an AGC option switch. When switched on, the AGC circuit limits the amplifier output power. The AGC circuit senses the output power and introduces more attenuation, when the output power exceeds the preset level. This way the gain of the amplifier is reduced, its output power is limited and the intermodulations products are kept below the desired level. In this manner the output power cannot exceed the +24 dBm preset power and the IMD levels are 13 dBm. The AGC amplifier has a Power LED lamp that illuminates when the output power has reached the preset power limit. In addition the BDA has a trimmer that enables continuos reduction of the gain by 15 dB. Wireless Solutions 48 Mivtza Kadesh St. Bene Beraq 51203 , ISRAEL Tel: +972-3-6175639 Fax:+972-3-6175962 3RIHPDLO [email protected] :HEVLWHZZZPZHOLVUDFRP5HY% BDA with AGC & MGC DETAILED RF BLOCK DIAGRAM BDA OPERATION connected to the antenna pointing into the area to be covered by the BDA. The isolation between the base station antenna and the mobile antenna should be at least 12 dB higher than the BDA gain. If the isolation were less than the BDA gain, oscillation would start and would saturate the amplifier. Isolation few dB higher than the BDA gain cannot start oscillations but would causes gain ripple in the band. 'XSOH[HU 'RZQOLQN 'XSOH[HU 8SOLQN 72 %$6( 67$7,21 $17(11$ 72 $5($ $17(11$ 17<3( 17<3( $*&5)$03/,),(5 $*&&,5&8,7 '(7(&7(5 $*&&,5&8,7 '(7(&7(5 $*&5)$03/,),(5 &283/(5 &283/(5 0*& 0*& Wireless Solutions 48 Mivtza Kadesh St. Bene Beraq 51203 , ISRAEL Tel: +972-3-6175639 Fax:+972-3-6175962 3RIHPDLO [email protected] :HEVLWHZZZPZHOLVUDFRP5HY% AGC & MGC FUNCTION The BDA has AGC function. Their amplifier has a directional coupler and a detector at the output of the high power amplifier to monitor the output power. When a high signal is received the automatic level control detects the amplitude and sends a feedback signal to a voltage variable attenuator which attenuates the signal level so that the output power of the amplifier does not exceed the preset limit. The LED on the amplifier illuminates when the power out the amplifier is within the set limit (both when the AGC is On and when the AGC is OFF). The switch on the RF amplifier enables the AGC function. If the AGC is disabled then the amplifier gives maximum gain. MGC: The RF gain of the BDA can be reduced by about 15 dB using the continuos trimmer on the amplifier. The RF gain is at maximum when the trimmer is at anti-clockwise direction. To reduce the gain, turn the trimmer clockwise using a screwdriver. Turning it halfway would reduce the gain by 7.5 dB. The AGC and MGC functions for the uplink path are reached by opening a small cover located on the DBA side adjacent to the Mobile antenna port. For the downlink path the window is located on the side near the Base antenna port. Note: The BDA is shipped with the AGC switch in the OFF position and maximum RF gain. AGC Enable Switch Power Out LED Gain Control Trimmer (MGC) AGC & MGC CONTROL (Control Window Located at BDA sides) Wireless Solutions 48 Mivtza Kadesh St. Bene Beraq 51203 , ISRAEL Tel: +972-3-6175639 Fax:+972-3-6175962 3RIHPDLO [email protected] :HEVLWHZZZPZHOLVUDFRP5HY% RF EXPOSURE WARNING In order to satisfy the FCC RF exposure requirements, you must ensure that the installation complies with the following: One antenna is connected via cable that has typical 1~10 dB attenuation (depends on the length of the cable) to the BDA BASE port. This antenna is installed outdoor and has very sharp beam (Yagi type or similar) pointed to the donor (BTS). This type of antenna has about 10 dBi gain. Typical specifications: gain: 8 dBd (=10.1 dBi), VSWR: better than 1.5:1 , Impedance: 50 ohm. The outdoor antenna must be installed to provide a minimum separation distance of 0.3 m (30 cm) from persons within the area. The second antenna is connected via cable that has typical 1~10 dB attenuation (depends on the length of the cable) to the CBDA MOBILE port. This type of antenna is omnidirecttional (isotropic), or wide beam, with 0 to 2 dBi typical gain and is installed and distribute…
Text truncated - open the document above for the full version.
:LUHOHVV6ROXWLRQV 0LYW]D.DGHVK6W%HQH%HUDT,65$(/7HO)D[ /$%(/)250$7)25&%'$7'0$:$
0$< 6800(5,=('352'8&7,1)250$7,21 0:&%'$7'0$%:$0RGHO1R &'0$ 7'0$$SSOLFDWLRQ ,6,60RGXODWLRQ 0+]8/ 0+]'/ )UHTXHQF\UDQJH G%P8/ G%P'/ 2XWSXWSRZHU
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±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° &WR ° & 6WRUDJHWHPSHUDWXUH ° &WR ° & ':*125HY3DJHRI 0(&+$1,&$/287/,1(
:LUHOHVV6ROXWLRQV &%'$7'0$%:$3$576/,67 3DUW1R'HVFULSWLRQ4XDQWLW\ 36$&213:5),/7(5$&$ 9+= =:$3:5683$&'&,19 2879$ 7(50,1$/&5,03+286,1* '$+($76,1. '$%'$&203$&7&+$66,6 '%%'$&203$&7&29(5 6060$ ; &0&$%/($66</ &060$3;&211 6060$ ; &0&$%/($66</ &060$3;&211 6060$ ; &0&$%/($66</ &060$3;&211 6060$ ; &0&$%/($66</ &060$3;&211 &'6.$',3/(;(50+])25%'$ '$$03:
FCC MPE Calculation Indoor Antenna RF Power = 0.250 W Cable Attenuation = 1 dB Power to Antenna = 0.199 W General Population Limit = (890/150) = 5.93 W/m 2 Antenna Gain = 2.0 dBi Numeric Antenna Gain = 1.58 Minimum Distance The user manual specifies 0.2 m minimum separation distance on page 6 which would result in a power density of: This provides a safety factor of 9.8 dB. m xP GP R D 0650.0 93.54 199.058.1 4 = × == ππ 2 22 /626.0 2.04 199.058.1 4 mW x x R GP P D === ππ
FCC MPE Calculation Outdoor Antenna RF Power = 0.250 W Cable Attenuation = 1 dB Power to Antenna = 0.199 W General Population Limit = (849/150) = 5.66 W/m 2 Antenna Gain = 10.1 dBi Numeric Antenna Gain = 10.2 Minimum Distance The user manual specifies 0.3 m minimum separation distance on page 6 which would result in a power density of: This provides a safety factor of 5 dB. m xP GP R D 169.0 66.54 199.02.10 4 = × == ππ 2 22 /79.1 3.04 199.02.10 4 mW x x R GP P D === ππ
:LUHOHVV6ROXWLRQV 0LYW]D.DGHVK6W%HQH%HUDT,65$(/7HO)D[ 'XSOH[HU '2:1/,1. $03/,),(5 'RZQOLQN 'XSOH[HU 83/,1. $03/,),(5 72 %$6( 67$7,21 $17(11$ 72 02%,/( $17(11$ 32:(5 6833/< 17<3( 17<3( 67$1'$5' :,5( ,1387$& &211(&725 '&9 &%'$7'0$%:$(/(&75,&$/6&(0$7,&6 3RZHU 0RQLWRU 3$ $*& 3RZHU 0RQLWRU 3$ $*&
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
&%'$7'0$:/$<287
Master: FCC Part22H Date: February 25, 2001 Test Report:1W03849 Applicant:Elisra Electronic Systems Ltd. 48 Mivtza Kadesh Street 51203, Bene-Beraq Israel Equipment Under Test:MW-CBDA-TDMA-B-1W60-A (EUT)Bi-Directional Amplfier FCC ID:OIWCBDATDMAB1W60 In Accordance With:FCC Part 22 Tested By:Nemko Canada Inc. (Formerly KTL Ottawa Inc.) 3325 River Road, R.R. 5 Ottawa, Ontario K1V 1H2 Authorized By: R. Grant, Wireless Group Manager Date: Total Number of Pages:53 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 2 of 49 Table of Contents Section 1. Summary of Test Results......................................................................................3 Section 2. General Equipment Specification........................................................................5 Section 3. RF Power Output..................................................................................................6 Section 4. Occupied Bandwidth............................................................................................9 Section 5. Spurious Emissions at Antenna Terminals........................................................22 Section 6. Field Strength of Spurious..................................................................................47 Section 7. Test Equipment List...........................................................................................49 Annex A Test Diagrams....................................................................................................A1 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 3 of 49 Section 1.Summary of Test Results General All measurements are traceable to national standards. These tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with FCC Part 22, Subpart H. New SubmissionProduction Unit Class II Permissive ChangePre-Production Unit AMP Equipment Code THIS TEST REPORT RELATES ONLY TO THE ITEM(S) TESTED. THE FOLLOWING DEVIATIONS FROM, ADDITIONS TO, OR EXCLUSIONS FROM THE TEST SPECIFICATIONS HAVE BEEN MADE. See “ Summary of Test Data”. NVLAP LAB CODE: 100351-0 TESTED BY: _____________________________________ DATE: ___________________ Wayne Clarke, Wireless Technologist Nemko Canada Inc. authorizes the above named company to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. Nemko Canada Inc. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. This report applies only to the items tested. Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 4 of 49 Summary Of Test Data Name Of TestPara. No.Result RF Power Output22.913(a)Complies Occupied Bandwidth22.917Complies Spurious Emissions at Antenna Terminals22.917Complies Field Strength of Spurious Emissions22.917Complies Frequency Stability22.355N/A Footnotes For N/A’s:This equipment does not have any frequency generating circuits. Test Conditions: IndoorTemperature:21 °C Humidity:30 % OutdoorTemperature:18 °C Humidity:70 % . Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 5 of 49 Section 2.General Equipment Specification Manufacturer: Elisra Electronic Systems Model No.: MW-CBDA-TDMA-B-1W60-A Serial No.: 0104D001 Date Received In Laboratory: May 23, 2001 Nemko Identification No.: Item #1 Supply Voltage Input: 120 VAC Frequency Range: Uplink:835 – 849MHz Frequency Range: Downlink:880 – 894MHz Type of Modulation and Designator: AMPS:F1D CDMA:DXW TDMA:F9W Output Impedance: 50Ω Gain: 60dB RF Output (Rated): +24dBm Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 6 of 49 Section 3.RF Power Output Para. No.: 2.985 Test Performed By: Wayne ClarkeDate of Test: May 24, 2001 Minimum Standard:Para. No. 22.913(a). Test Results:Complies. Measured Power:Uplink:+24dBm Downlink:+24dBm Measurement Data:See attached graphs. Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 7 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 8 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 9 of 49 Section 4.Occupied Bandwidth Para. No.: 2.917(c) Test Performed By: Wayne ClarkeDate of Test: May 24, 2001 Minimum Standard:22.917 Test Results:Complies. There was no degradation in the output signal. Test Data:See attached graph(s). Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 10 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 11 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 12 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 13 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 14 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 15 o…
Text truncated - open the document above for the full version.
Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 22 of 49 Section 5.Spurious Emissions at Antenna Terminals Para. No.: 2.917(e) Test Performed By: Wayne ClarkeDate of Test: May 24, 2001 Minimum Standard:Para. No. 22.917(e). Test Results:Complies. Test Data: Name Of TestWorst-Case Spurious Level(dBm) 0 to 10 GHz Spurious (Uplink)None-Detected 0 to 10 GHz Spurious (Downlink)None-Detected 2 - Signal Intermodulation (Uplink)Below –13dBm 2 - Signal Intermodulation (Downlink)Below –13dBm Lower Band Edge Spurious (Uplink)Below –13dBm Lower Band Edge Spurious (Downlink)Below –13dBm Upper Band Edge Spurious (Uplink)Below –13dBm Upper Band Edge Spurious (Downlink)Below –13dBm Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 23 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 24 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 25 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 26 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 27 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 28 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 29 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 30 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 31 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 32 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 33 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 34 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 35 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 36 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 37 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 38 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 39 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 40 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 41 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 42 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 43 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 44 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 45 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 46 of 49 Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 47 of 49 Section 6.Field Strength of Spurious Para. No.: 2.917(e) Test Performed By: Wayne ClarkeDate of Test: May 30, 3001 Minimum Standard:Para. No. 22.917 Test Results:Complies. There were no emissions detected at 3m on the oats. The spectrum was searched up to the 10 th harmonic of the fundamental frequency of operation. Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 48 of 49 Photographs of Test Setup (Worst Case Configuration) Front View Nemko Canada Inc.FCC PART 22 PROJECT NO.: 1W03849 EQUIPMENT: MW-CBDA-TDMA-B-1W60-A Bi-Directional Amplifier FCC ID: OIWCBDATDMAB1W60 Page 49 of 49 Section 7.Test Equipment List CAL CYCLE EQUIPMENTMANUFACTURERMODELSERIALLAST CAL.NEXT CAL. 1 YearSpectrum AnalyzerHewlett Packard8565EFA000981June 16/00June 16/01 2 YearRF MillivoltmeterRohde & SchwarzURV5FA000420Oct. 6/99Oct. 6/01 2 YearInsertion UnitRohde & SchwarzURV5-Z4FA000905Oct. 6/99Oct. 6/01 2 YearPower SensorRohde & SchwarzURV5-Z5FA000419Oct. 6/99Oct. 6/01 1 YearPower MeterHewlett PackardE4448BFA001413Jan. 16/01Jan. 16/02 1 YearPower SensorHewlett Packard8487AFA001419Jan. 16/01Jan. 16/02 1 YearHorn AntennaEMCO #231154336Dec. 1/00Dec. 1/01 1 Year50 ohm Combiner PadMini CircuitsZFC-3-4922603Nov. 19/99Nov. 19/00 3 YearSignal GeneratorRohde & SchwarzSM1Q03DE22004Sept. 18/00Sept. 18/03 3 YearSignal GeneratorRohde & SchwarzSM1Q03EDE24154Oct. 4/99Oct. 4/92 1 YearRF AMPJCA2-4 GHzFA001496May 31/00May 31/01 1 YearRF AMPJCA1-2 GHzFA001498May 31/00May 31/01 1 YearRF AMPJCA4-8…
Text truncated - open the document above for the full version.
| # | Rule Parts | Frequency Range | Power Output | Emission |
|---|---|---|---|---|
| 8 | 22H | 880 MHz - 894 MHz | 250.00 mW | F8W |

Digital Channel Selective Amplifier-UHF (DCSA-UHF)
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
DUAL BAND IDEN REPEATER
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
CDMA MIDI REPEATER UNIT 80DB/30DBM WITH CCD
Equipment Class
PCB - PCS Licensed Transmitter
Digital Channel Selective Amplifier � UHF
Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Multi-Band iDEN and WPCS Booster
Equipment Class
PCB - PCS Licensed Transmitter