August, 2022 File history Document title Everon 6000 G2(3500) commissioning instruction manual Document resume Edition Organizatio n Date Changes (terms) V1. 0 Xionglin He 2022-08-01 First release Content Foreword .............................................................................................................................. 2 1 Operating environment ................................................................................................... 4 1.1 Computer hardware configuration requirements ............................................ 4 1.2 Computer software configuration requirements .............................................. 4 2 Overview ........................................................................................................................... 4 3. System connection description of RIU+DCU+DEU+dLRU (1+1+1+1) .................. 5 4 Configuration instructions before accessing WEB OMT ........................................... 6 5 Software upgrade operation instructions ..................................................................... 7 5.1 RIU software upgrade instructions ........................................................................ 8 5.2 DCU software upgrade instructions....................................................................... 9 5.3 DEU software upgrade instructions ..................................................................... 12 5.4 dLRU software upgrade instructions ................................................................... 14 6 System WEB configuration description ...................................................................... 15 6.1 RIU WEB configuration description ..................................................................... 16 6.2 DCU WEB configuration description ................................................................... 17 6.3 DEU WEB configuration description ................................................................... 19 6.4 dLRU WEB configuration description .................................................................. 22 Foreword This manual introduces the Everon 6000 G2 commissioning instructions and relevant operating instructions WEB OMT configuration through IE7/IE8, Firefox and Chrome browsers. Since the system of this product will be constantly updated and the software will be constantly upgraded, the software version described in this manual may be different from the pictures. Therefore, the parameters, specifications, and others in this manual are subject to change without notice. Abbreviation notes are shown in the following table: Abbreviation notes Table 1 ALC Automatic Level Control AGC Automatic Gain Control ATT Attenuation BTS Base Transceiver Station DL Downlink UL Uplink ANT Antenna MCU Main Control Unit LNA Low Noise Amplifier OMT Operation & Maintenance Terminal WebOMT Web Operation & Maintenance Terminal OP Optical Fiber WDM Wavelength Division Multiplexer WCDMA Wideband Code Division Multiple Access CDMA Code Division Multiple Access FCC Federal Communications Commission LTE (3G) Long Term Evolution MIMO Multiple Input Multiple Output Abbreviation notes Table 2 DAS Distributed Antenna System dLRU-G2-678 Low Power Remote (20dBm) for 600, 700L/700U/700FN, 850, 2T2R MIMO (requires 1x10G SFP, ordered separately) dLRU-G2- 17192325 Low Power Remote (20dBm) for AWS, PCS, WCS and 2.5GHz (194MHz), 2T2R MIMO (requires 3x10G SFP, ordered separately) dLRU-G2-25 Low Power Remote (23dBm) for 2.5GHz (194MHz), 2T2R MIMO (requires 1x25G SFP, ordered separately) dLRU-G2-35 Low Power Remote (26dBm) for C-Band, 2T2R MIMO (requires 2x25G SFP, ordered separately) dMRU-G2-25 Mid power remote (8W) for 2.5GHz, 2T2R MIMO, AC power (requires 1x25G SFP, ordered separately) dMRU-G2-35 Mid power remote (8W) for C-Band, 2T2R MIMO, AC power (requires 2x25G SFP, ordered separately) RIU-G2-25 Radio Interface Unit (RIU) for 2.5GHz, 8 x 4.3-10 ports, support for either 2 x 4T4R2 or 4 x 2T2R, input power range: -10~37 dBm RIU-G2-35 Radio Interface Unit (RIU) for C-Band, 8 x 4.3-10 ports, support for either 2 x 4T4R2 or 4 x 2T2R, input power range: -10~37 dBm DCU-G2 Digital Conversion Unit (DCU) for FDD and TDD bands. Supports 2 x 8T8R/4 x 4T4R/8 x 2T2R, up to 16 RF Channels, 8 optical ports for DEU connection, 4 optical ports for cascading DAU (requires 25G SFPs, ordered separately) DEU-G2 Digital Extension Unit (DEU) includes 28 optical ports (HW line rate up to 25Gbps), 4 optical ports for DEU cascade (25Gbps), 24 optical ports for radio connection (dLRU/dMRU/dHRU) (requires 25G SFPs, ordered separately) DEU-G2-PS Digital Extension Unit (DEU) includes 28 optical ports (HW line rate up to 25Gbps), 4 optical ports for DEU cascade (25Gbps), 24 optical ports for radio connection (dLRU/dMRU/dHRU). Include 12 x power supply ports (max 100W) (requires 25G SFPs, ordered separately) dLRU-G2-678 Low Power Remote (20dBm) for 600, 700L/700U/700FN, 850, 2T2R MIMO (requires 1x10G SFP, ordered separately) dLRU-G2- 17192325 Low Power Remote (20dBm) for AWS, PCS, WCS and 2.5GHz (194MHz), 2T2R MIMO (requires 3x10G SFP, ordered separately) dLRU-G2-25 Low Power Remote (23dBm) for 2.5GHz (194MHz), 2T2R MIMO (requires 1x25G SFP, ordered separately) dLRU-G2-35 Low Power Remote (26dBm) for C-Band, 2T2R MIMO (requires 2x25G SFP, ordered separately) dMRU-G2-25 Mid power remote (8W) for 2.5GHz, 2T2R MIMO, AC power (requires 1x25G SFP, ordered separately) 1 Operating environment 1.1 Computer hardware configuration requirements ⚫ Computer: main frequency above 2GHz, memory above 512MB, display resolution: 1024×768 above; ⚫ With an RJ45 network port; ⚫ Or with a USB port, external USB to RJ45 network port. 1.2 Computer software configuration requirements ⚫ Operating system: Windows XP, Windows 7, windows 10 and above; ⚫ Browser: Mozilla Firefox and above, Google Chrome 67 and above, IE9/IE10 and above are recommended; 2 Overview The product can use the network management system to query and set …
Text truncated - open the document above for the full version.
Corning Optical Communications Everon™ 6000 Gen 2 DAS Solution Specification Sheet | CMA-818-AEN Corning Restricted Everon ™ 6000 Gen 2 DAS Solution Specification Sheet Features and Benefits Corning’s Everon 6000 Gen 2 DAS Solution is an advanced inbuilding cellular service solution for small, medium, and large size venues, supporting a broad range of cellular generations: 3G,4G and 5G. This solution is based on a point-to-multipoint distribution architecture, advanced digital transport and processing, and channelized implementation, enabling efficient utilization of digital links. It is designed to support multi-band, multi- technology, and multi-operator networks over the single fiber-based infrastructure. The Corning Everon™ 6000 Gen 2 DAS Solution is a high bandwidth distribution architecture that provides preparedness for future radio technologies, broader spectrum, and new frequency bands. Due to its modular design and configuration flexibility, this solution is highly scalable in terms of supported capacity (number of sectors, frequency bands, channels) and remote units (coverage), and can be easily configured to support a large variety of deployment scenarios including single and multi-building (“campus”) network topologies. This solution offers multiple types of digital remote units, supporting a variety of frequency band combinations, with different power levels ranging from 20 dBm per band to 46 dBm per band. Advanced network configuration and management capabilities enable on-site as well as remote end-to-end configuration, system diagnostics, maintenance, and support network operations center (NOC) connectivity. Features Benefits Comprehensive Service Support 600 MHz, 700 MHz, FirstNet, 800/850 MHz, 1900 MHz (PCS), EAWS, 2300 MHz (WCS), 2500 MHz (TDD), 3500 MHz (TDD). Support of MIMO services, FDD and TDD. Supports 3G, 4G, 5G technologies. Multi-X System Supports multi-operator, multi-band, multi-technology services over a single infrastructure. Supports single and multi-building (“campus”) network solutions. Highly Modular/Highly Scalable Can be easily expanded to support additional capacity: sectors, frequency bands, channels, and coverage areas, by increasing the number of remotes. Advanced Digital Signal Processing Provides higher dynamic range, enables per-channel granularity, delivers enhanced overall power efficiency, and improves overall system performance. Digital Common Public Radio Interface (CPRI) based Transport Provides robust signal distribution with flexible scalability. Digital Service and Capacity Routing Enables advanced capacity and coverage management through flexible routing configuration management. Carrier-Grade Network Management Network configuration and management capabilities enable on-site and remote end-to-end configuration, system diagnostics, maintenance, support management and control by network management system. Corning Optical Communications Everon™ 6000 Gen 2 DAS Solution Specification Sheet | CMA-818-AEN Corning Restricted System Architecture: Everon™ 6000 Gen 2 Solution RIU—Radio Interface Unit The RIU provides an interface and signal conditioning to signals coupled between the base station RF antenna ports and the DCU. DCU—Digital Conversion Unit The DCU provides RF to CPRI (Downlink) and CPRI to RF (Uplink) conversion, where the well-known CPRI (Common Public Radio Interface) standard is used for representing the RF signals. DEU– Distributed Extension Unit The DEU is the central Hub and Distribution element for the Everon™ 6000 Gen 2 Solution. The DEU interfaces between the DCU and the remote unit, allowing it to receive the operators service signals in CPRI format, and to route these signals to the remote antenna units. The DEU supports all Corning digital remote antenna units’ flavors, for all services, power levels and antenna configurations (SISO or MIMO). Each DEU includes 2 optical ports connected to a DCU, 2 optical ports for cascade, and 24 optical ports for connection to remote units. When more remote antenna units are needed, the system scales up easily by adding additional DEUs. Service Provider #N A RIU A DCU A DEU Base stations Digital Conversion Units Radio Interface Units Distributed Extension Units A DHRU A DLRU A DMRU Medium Power Remote Units High Power Remote Units Remote Operator Configuration and NMS Local Configuration Low Power Remote Units Corning Optical Communications Everon™ 6000 Gen 2 DAS Solution Specification Sheet | CMA-818-AEN Corning Restricted dLRU—Digital Low-power Remote Unit The dLRU is a low-power remote antenna unit with 20~24 dBm per MIMO stream per band output RF power and native support of 2x2 MIMO antenna scheme. There are four types of dLRU: 1.Low band dLRU - supports 600 MHz (band 71), 700 MHz Low (band 12), 700 MHz High (band 13), FirstNet (band 14), 800/850 MHz (band 26) bands via one fiber connection. 2.Medium Band dLRU - supports EAWS (band 66), PCS (band 25), WCS (band 30) and 2.5 GHz TDD (band 41) services via 3 fiber connections. 3.Band 41 dLRU - supports single band 2.5 GHz TDD via single fiber. 4.High Band dLRU - supports 3500 MHz TDD (CBRS/C-Band) services via 2 fiber connections. The dLRU cooling is natural convection with no fans. Due to its IP66 enclosure design the dLRU can also be installed outdoors. dMRU—Digital Medium-power Remote Unit The dMRU is a medium-power remote antenna unit with 37~40 dBm per MIMO stream per band output RF power and native support of 2x2 MIMO antenna scheme. The dMRU cooling is based on natural convection, requiring no fans. Due to its IP65 enclosure design, the dMRU can also be installed outdoors. dHRU—Digital High-power Remote Unit The dHRU is a high-power modular remote antenna unit which provides 43~46 dBm output RF power per service module, and native support of 2x2 MIMO antenna scheme. The dHRU modular structure enables set ups of up to 8 service modules in 600 MHz, 700 MHz Low/700 MHz High/FirstNet, 800/850 MHz, EAWS, PCS, WCS, 2.5 GHz TDD an…
Text truncated - open the document above for the full version.
Corning Optical Communication LLC Attestation To whom it may concern, We Corning Optical Communication LLC declare that warning label messages will be also shown in online and point-of-sale marketing marterials and on outside packaging of device. WARNING! This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC License to operate this device. Unauthorized use may result in significant forfeiture penalties, including penalties in excess of $100,000 for each continuing violation. Name (Printed): Jyotin Basrur Title:Senior Director, Product Line Management Signature: On behalf of Company: Corning Optical Communication LLC
Corning Optical Communication LLC Corning Restricted Authority letter FCC Date: 7/29/2022 TO: Federal Communication Commission Equipment Authorization Branch 7435 Oakland Mills Road Columbia, MID 21046 Regarding: FCC ID: OJFDLRUG235 To whom it may concern: We, the undersigned, hereby authorize SGS-CSTC Standards Technical Services Co., Ltd. (SGS) Guangzhou branch and Kobe Jian in SGS-CSTC Standards Technical Services Co., Ltd. (SGS) Guangzhou branch to act on our behalf in all manners relating to application for equipment authorization with respect to the FCC ID above, including signing of all documents relating to these matters. Any and all acts carried out by the agent on our behalf shall have the same effect as acts of our own. We, the undersigned, hereby certify that we are not subject to a denial of federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Where our agent signs the application for certification on our behalf, I acknowledge that all responsibility for complying with the terms and conditions for Certification, as specified by SGS North America, Inc., still resides with Corning Optical Communication LLC. This authorization is valid until further written notice from the applicant. Name (Printed): Jyotin Basrur Title: Senior Director, Product Line Management Signature: On behalf of Company: Corning Optical Communication LLC
Corning Optical Communication LLC Corning Restricted Confidential letter FCC To: SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia United States From: Corning Optical Communication LLC 6 Concord Road Shrewsbury, Massachusetts, 01545, United States Regarding: Confidentiality Request regarding application for FCC ID: OJFDLRUG235 LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission’s rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Descriptions Tune-up procedure The documents above contain proprietary information not released to the public. Public disclosure of this information may prove harmful to the business of the applicant. Sincerely, Name (Printed): Jyotin Basrur Title: Senior Director, Product Line Management Signature: On behalf of Company: Corning Optical Communication LLC
SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Declaration Applicant Declaration Letter Applicant Legal Business Name Corning Optical Communication LLC Address 6 Concord RoadShrewsbury, 01545, Massachusetts, United States Grantee Code OJF FCC ID OJFDLRUG235 Authorized Contact Name Jyotin Basrur Contact Email [email protected] Contact Phone 817-431-7894 I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare; a) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b) in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in this application, the Applicant is responsible for: (1) labeling the equipment with the exact FCC ID as specified in this application, (2) compliance statement labeling pursuant to the applicable rules, (3) compliance of the equipment with the applicable technical rules, c) if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. d) in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e) in accordance with ISO17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements. (1) the Applicant understands, accepts and agrees that a sample may be requested for surveillance testing. (2) the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. (3) the Applicant shall, upon request by SGS, at the Applicant’s expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Applicant Signature: Date: 7/29/2022 Print Name: Jyotin Basrur Title: Senior Director, Product Line Management *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database Applicant Declaration Rev:0.0
Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 1 of 5 External Photos for FYCR2207000277AT FCC ID: OJFDLRUG235 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 2 of 5 EUT Constructional Details (EUT Photos) Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 3 of 5 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 4 of 5 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 5 of 5
dLRU-G2-35 FCC warning label Product label
Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 1 of 3 Internal Photos for FYCR2207000277AT FCC ID: OJFDLRUG235 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 2 of 3 EUT Constructional Details (EUT Photos) Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Page: 3 of 3 \
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR220700091604 Page: 1 of 11 FCC ID: OJFDLRUG235 Kobe Jian EMC Laboratory Manager RF EXPOSURE EVALUATION REPORT Application No.: GZCR2207000916AT Applicant: Corning Optical Communication LLC Address of Applicant: 6 Concord Road, Shrewsbury, MA 01545 United States Manufacturer: Comba Network System Company Limited Address of Manufacturer: No.10 Shenzhou Road, Guangzhou Science City, Guangzhou, Guangdong Factory: Comba Telecom Technology (Guangzhou) Ltd. Address of Factory: No.6 Jinbi Road, Economics and Technology Development District, Guangdong, China Equipment Under Test (EUT): EUT Name: Digital Low-power Remote Unit High Band Supporting 3.5G Model No.: dLRU-G2-35 Standard(s) : 47 CFR Part 2.1091 47 CFR Part 1.1310, Part 1.1307 Date of Receipt: 2022-07-15 Date of Evaluation: 2022-08-04 Date of Issue: 2022-08-05 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR220700091604 Page: 2 of 11 Revision Record VersionChapterDateModifier Remark 01GZCR2207000916042022-08-05Original Authorized for issue by: Kevin Zhang /Project Engineer Jerry Chan /Reviewer SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR220700091604 Page: 3 of 11 2Evaluation Summary Radio Spectrum Technical Requirement ItemStandardRequirementMethodResult RF Exposure 47 CFR Part 2.1091 47 CFR Part 1.1310 47 CFR Part 1.1307 47 CFR Part 1.131047 CFR Part 1.1310PASS SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR220700091604 Page: 4 of 11 3Contents Page 1 Covers Page................................................................................................................................................1 2Evaluation Summary..................................................................................................................................3 3Contents......................................................................................................................................................4 4General Information....................................................................................................................................5 4.1Details of E.U.T...............................................................................................................................................5 4.2Evaluated Location........................................................................................................................................6 4.3Test Facility......................................................................................................................................................7 4.4Deviation from Standards............................................................................................................................7 4.5Abnormalities from Standard Conditions................................................................................................7 5Radio Spectrum Technical Requirement..................................................................................................8 5.1RF Exposure....................................................................................................................................................8 5.1.1Requirement.................................................................................................................................................8 5.1.2Method...........................................................................................................................................................9 5.1.3Conclusion....................................................................................................................................................9 5.2EUT Constructional Details (EUT Photos).............................................................................................11 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR220700091604 Page: 5 of 11 4General Information 4.1Details of E.U.T. Power Supply:DC 38-58V Test Voltage:DC 48V Cable:N/A Operating Temperature:-40 to +55 °C Operating Humidity:≤95% Frequency Range: Uplink: 3450-3550MHz Downlink: 3450-3550MHz Uplink: 3550-3700MHz Downlink: 3550-3700MHz Uplink: 3700-3980MHz Downlink: 3700-3980MHz GSM WCDMA LTE Support Technology: 5G NR Modulation Type:PSK/QPSK/QAM/16QAM/64QAM/256QAM LTE10MHz/20MHz Support Channel Bandwidth: 5G NR10MHz/20MHz/40MHz/60MHz/80MHz/100MHz CPRI Port2 (SFP+) Antenna Port2 (4.3-10-Female, ANT1~ANT2) Power Jack1 Interface: Debug Port1 (RJ45) 3.45GHz Service:Maximum 24dBm CBRS:Maximum 19dBm/10MHz Normal Output Power: (only downlink, per antenna port) 3.7GHz Service:Maximum 24dBm Maximum System Gain:Uplink: 0dB Downlink: 0dB EUT Configuration:2T2R (2X2 MIMO, the internal circuit designs and the intend output power for each antenna port are identical, declared by the manufacturer) Antenna Type: External Dedicated Antenna Permission Antenna Gain: 0dBi or less (declared by the manufacturer) Software Version: DLRUG2_V01.00.01.23 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR220700091604 Page: 6 of 11 4.2Evaluated Location All evaluation were performed at: SGS-CSTC Standards Technical Services Co., Ltd., Guangzhou Branch EMC Laboratory, 198 Kezhu Road, Scientech Park, Guangzhou Economic & Technology Development District, Guangzhou, China 510663 Tel: +86 20 82155555Fax: +86 20 82075059 SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch EMC-TRF-03 Rev 1.1 Report No.: GZCR220700091604 Page: 7 of 11 4.3Test Facility The test facility is recognized, certified, or accredited by the following organizations: ● NVLAP (Lab Code: 200611…
Text truncated - open the document above for the full version.
Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Report No.: FYCR220700027701 Page: 1 of 45 Winkey Wang EMC Technical Manager TEST REPORT Application No.: FYCR2207000277AT Applicant:Corning Optical Communication LLC Address of Applicant:6 Concord Road, Shrewsbury, MA 01545 United States Manufacturer:Comba Network System Company Limited. Address of Manufacturer:No.10 Shenzhou Road, Guangzhou Science City, Guangzhou, Guangdong Factory:Comba Telecom Technology (Guangzhou) Ltd. Address of Factory:No.6 Jinbi Road, Economics and Technology Development District, Guangdong, China Equipment Under Test (EUT): EUT Name:Digital Low-power Remote Unit High Band supporting 3.5G Model No.: dLRU-G2-35 FCC ID:OJFDLRUG235 Standard(s) : FCC Part 2, FCC Part 20, FCC Part 96 Date of Receipt: 2022-07-21 Date of Test: 2022-07-26 to 2022-08-02 Date of Issue: 2022-08-03 Test Result: Pass* * In the configuration tested, the EUT complied with the standards specified above. Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Report No.: FYCR220700027701 Page: 2 of 45 Revision Record VersionChapterDateModifierRemark 012020-08-03Original Authorized for issue by: Tree Zhan/Project Engineer Winkey Wang/Reviewer Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Report No.: FYCR220700027701 Page: 3 of 45 2Test Summary Test ItemReferenceResult RF Output Power, Amplifier Gain and Peak to Average Ratio FCC PART 2.1046; FCC PART 96.41PASS Conducted Spurious Emissions FCC PART 2.1051; FCC PART 96.41PASS Out-of-band/out-of-block (including intermodulation) Emissions FCC PART 2.1051; FCC PART 96.41PASS Adjacent Channel Leakage Ratio (ACLR) FCC PART 96.41PASS Radiated Spurious EmissionsFCC PART 2.1053; FCC PART 96.41PASS Occupied Bandwidth and Input- versus-output signal comparison FCC PART 2.1049PASS Frequency StabilityFCC PART 2.1055PASS Out of Band RejectionKDB 935210 D05 v01r04 3.3PASS Remark: EUT: In this whole report EUT means Equipment Under Test. Tx: In this whole report Tx (or tx) means Transmitter. Rx:In this whole report Rx (or rx) means Receiver. All modes have been tested and only record the worst test result. This is a DAS, no need to implement uplink test as it is cable connect to BTS (No air radiation), then the test about Uplink would be ignored. Test method standard: ANSI C63.26-2015 KDB 935210 D05 Indus Booster Basic Meas v01r04 KDB 935210 D02 Signal Booster Certification v04r02 KDB 940660 D01 Part 96 CBRS v03 Compliance Certification Services (Kunshan) Inc. Shenzhen Branch Report No.: FYCR220700027701 Page: 4 of 45 3Contents Page 1COVER PAGE...........................................................................................................................................1 2TEST SUMMARY..................................................................................................................................3 3CONTENTS...........................................................................................................................................4 4GENERAL INFORMATION....................................................................................................................6 4.1Details of E.U.T................................................................................................................................................6 4.2Test Environment.............................................................................................................................................7 4.3Description of Support Units..........................................................................................................................7 4.4Measurement Uncertainty..............................................................................................................................8 4.5Test Location....................................................................................................................................................9 4.6Test Facility.......................................................................................................................................................9 4.7Deviation from Standards..............................................................................................................................9 4.8Abnormalities from Standard Conditions....................................................................................................9 5EQUIPMENT LIST...............................................................................................................................10 6TEST PROCEDU…
Text truncated - open the document above for the full version.
No.198 Kezhu Road, Science City Economic & · Guangzhou, Guangdong · China
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 96 | 3.55 GHz - 3.70 GHz | 170.00 mW | W7D | Amp |

Remote Unit, Radio Node
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
HRU Digital High Power Amplifier Module supporting PCS
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
Low Band dRAU
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
digital Medium-power Remote Unit
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)
digital Medium-power Remote Unit
Equipment Class
B2I - Part 20 Industrial Booster (CMRS)