OKY1005500251A01BInductive Tag Reader

Baltech AG
Inductive Tag Reader - FCC ID OKY1005500251A01B - Baltech AG
Click to zoom

Application Details

Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Date of Grant
Aug 27, 2006
Application Purpose
Original Equipment
Date of Application
Aug 27, 2006
Equipment Note
Inductive Tag Reader
Frequency Range
13.56000000 - 13.56000000
Company
Baltech AG
Country
Germany

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Operation Manual 0055A01B-002 / ACCESS45-LP-5-232-LB-EQUITRAC REVISION 1.0, 2006-08-06 The ACCESS45-5-232-LEGP-LB is a RFID Read-/Write-Device (short: reader) which is compatible to all Legic Prime cards. It provides a serial interface RS232 to output or exchange data with a host computer (typically an Equitrac Page Counter Unit, a printer or a copy machine) and a 13.56MHz inductive interface to provide power to and exchange data with the Legic Prime card (or other available form-factors such as tags, key-fobs). The host computer can control a bi-colour LED and a beeper to interface with the user. Mounting and Connection The reader generates a magnetic field with the frequency of 13.56MHz which is influenced by any electrically conductive material in close proximity to the device. When mounting the unit, a distance to any such material of minimum 10 cm is required to ensure that there will be no significant degradation of the performance in terms of read range and reliability. Mounting the unit directly to metal would result in a severe reduction of read range down to zero functionality. Care should be taken when testing the device after mounting at a problematic environment: Read ranges and performance vary from card to card and very much from card to tag or key-fob. When mounting multiple readers, the distance between readers should be minimum 0.5 m to avoid degradation of performance due to interference. To connect the device to an Equitrac PageCounter, printer or copy machine, please make sure the host system provides an 8-pin Mini-DIN socket intended for connection of the reader. Alternatively, the reader can be connected to any serial RS232-interface by using a converter connector from 8-pin Mini-DIN female to D-Sub 9 female and suitable connection for a power supply. In case the LED and Beeper control lines should be operated, suitable control can be applied according to the below given specifications. Operation Whenever the device is connected to a proper power supply, it will switch on the internal antenna and periodically scan for a card. Once a card has been detected, the card number is read, the data converted and sent to the host system through the serial interface. To enable the device to read cards, tags and key-fobs successfully, they should be placed centred above the reader. Technical Data DC Electrical Characteristics Symbol Parameter Condition Min Typ Max Units Vdd Supply Voltage 4.75 5 5.5 VDC Idd Supply current 200 mA Idd1 Peak Supply current Inrush 450 mA Vih Input high voltage 3.3 Vdd+0.3 V Vil Input low voltage -0.3 0.8 V Ii Input leakage current 300 uA Additional requirements for the supply voltage: Vripple = 50mVpp max. RF Characteristics Operating frequency: 13.56 MHz Data transmission modulation reader to card: AM Data transmission modulation card to reader: AM/load modulation Pinout 8-Pin Mini-DIN plug and Signal Descriptions Pin Name Type Description 1 PWR Power 5V Power Supply 2 TXD Output RS232-data from reader 3 RXD Input RS232-data to reader 4 RED Input LED red (when LED green is low) 5 GRN Inpur LED green (when LED red is low) 6 - - Not connected 7 /SPKR Input Speaker enable (active low) 8 GND Power Signal and Power Ground Serial Interface The TXD/RXD signals are compatible with RS-232 level signals. The interface operates at 2400 baud, no parity, 8 data bits, 1 stop bit. Upon detection of a valid card swipe, the reader outputs the card number in ASCII format. Temperature Operating temperature range: 0...35°C Storage temperature range: -20...+60°C Thermal shock: 30°C/min maximum dT/dt Humidity Operating: 20% to 80% relative humidity; non condensing Non-operating: 10% to 90% relative humidity; non condensing FCC Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.

Cover Letter(s)

Federal Communications Commission 445 12 th Street SW Washington, DC 20554 USA Request for Confidentiality in accordance with CFR 0.457 and 0.459 25 August 2006 EMCCert DR. RAŠEK - Certification Institute - Boelwiese 5 D-91320 Ebermannstadt RE: Certification Application FCC ID: OKY1005500251A01B Please be advised that the following information is to be held confidential on behalf of Baltech AG: • Schematics • Parts List • Block Diagram • Technical Description The application contains technical information which Baltech AG deems to be trade secrets and proprietary. If made public, the information might be used to the disadvantage of the applicant in the market place. Thank you for your attention to this matter.

Internal Photos

FCC ID OKY1005500251A01B FCC ID OKY1005500251A01B

Test Report

Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Note: The test data of this report is related only to the individual item which has been tested. This report shall not be reproduced except in full extent without the written approval of the testing laboratory. Test Report No. 50235-060611-3 (Edition 1) Page 1 of 48 Pages Straubing, August 25, 2006 T E S T - R E P O R T No. 50235-060611-3 (Edition 1) for ACCESS45-LP-5-232-LB-EQUITRAC Inductive Tag Reader Applicant: BALTECH AG Test Specifications: FCC Code of Federal Regulations, CFR 47, Part 15, Sections 15.205, 15.207, 15.215 and 15.225 Industry Canada Radio Standards Specifications RSS-Gen Issue 1, Section 7.2.2 and RSS-210 Issue 6, Sections 2.2, 2.6, A2.6 (Category I Equipment) Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50235-060611-3 (Edition 1) Page 2 of 48 Pages Table of Contents 1 Description of the Equipment Under Test (EUT)......................................................... 3 2 Administrative Data..................................................................................................... 4 3 Identification of the Test Laboratory............................................................................ 5 4 Summary .................................................................................................................... 6 5 Operation Mode and Configuration of EUT ................................................................. 7 6 Measurement Procedures........................................................................................... 8 6.1 Bandwidth Measurements .................................................................................... 8 6.2 Conducted AC Powerline Emission.................................................................... 10 6.3 Radiated Emission Measurement 9 kHz to 30 MHz ........................................... 12 6.4 Radiated Emission in Fully or Semi Anechoic Room .......................................... 14 6.5 Radiated Emission at Open Field Test Site ........................................................ 16 6.6 Carrier Frequency Stability ................................................................................. 17 7 Photographs Taken During Testing .......................................................................... 19 8 Test Results .............................................................................................................. 27 8.1 Occupied Bandwidth........................................................................................... 29 8.2 Bandwidth of the Emission ................................................................................. 34 8.3 Designation of Emissions ................................................................................... 36 8.4 Conducted Powerline Emission Measurement 150 kHz to 30 MHz ................... 37 8.5 Spectrum Mask................................................................................................... 38 8.6 Radiated Emission Measurement 9 kHz to 30 MHz .......................................... 40 8.7 Radiated Emission Measurement 30 MHz to 1 GHz ......................................... 41 8.8 Carrier Frequency Stability ................................................................................. 42 8.9 Exposure of Humans to RF Fields...................................................................... 45 9 Referenced Regulations ........................................................................................... 47 10 Charts taken during testing ....................................................................................... 48 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50235-060611-3 (Edition 1) Page 3 of 48 Pages 1 Description of the Equipment Under Test (EUT) General data of EUT Type designation 1 : ACCESS45-LP-5-232-LB-EQUITRAC Parts 2 : --- Serial number(s): Sample no. 1 Manufacturer: BALTECH AG Type of equipment: Inductive Tag Reader Version: As delivered FCC ID: OKY1005500251A01B Additional parts/accessories: with tag "Legic Supertag 1024" Technical data of EUT Application frequency range: 13.110 – 14.010 MHz Frequency range: 13.560 MHz Operating frequency: 13.560 MHz Type of modulation: Amplitude Modulation (AM) Number of RF-channels: 1 Channel spacing: Not applicable Designation of emissions 3 : 10K0A1D Type of antenna: Integrated loop antenna (printed board) Size/length of antenna: Rectangle: 72 mm x 37 mm Connection of antenna: detachable not detachable Type of power supply: DC supply Specifications for power supply: nominal voltage: 5.00 V DC minimum voltage: 4.25 V DC maximum voltage: 5.50 V DC 1 Type designation of the system if EUT consists of more than one part. 2 Type designations of the parts of the system, if applicable. 3 Also known as "Class of Emission". Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50235-060611-3 (Edition 1) Page 4 of 48 Pages 2 Administrative Data Application details Applicant (full address): BALTECH AG Lilienthalstrasse 27 D-85399 Hallbergmoos Germany Contact person: Mr. Jürgen Rösch Contract identification: --- Receipt of EUT: August 1, 2006 Date(s) of test: August 8 and August 21 to 24, 2006 Note(s): --- Report details Report number: 50235-060611-3 Edition: 1 Issue date: August 25, 2006 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50235-060611-3 (Edition 1) Page 5 of 48 Pages 3 Identification of the Test Laboratory Details of the Test Laboratory Company name: Senton GmbH EMI/EMC Test Center Address: Aeussere Fruehlingstrasse 45 D-94315 Straubing Germany Laboratory accreditation: DAR-Registration No. DAT-P-171/94-02 FCC test site registration number 90926 Industry Canada test site registration: IC 3050 Contact person: Mr. Johann Roidt Phone: (+49) (0)9421 5522-0 Fax: (+49) (0)9421 5522-99 Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No.…

Text truncated - open the document above for the full version.

Test Setup Photos

Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50235-060611-3 (Edition 1) Page 20 of 48 Pages Test setup for conducted AC powerline emission measurement Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50235-060611-3 (Edition 1) Page 21 of 48 Pages Test setup for conducted AC powerline emission measurement - continued - Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50235-060611-3 (Edition 1) Page 22 of 48 Pages Test setup for radiated emission measurement 9 kHz – 30 MHz (prescan in fully anechoic room) Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50235-060611-3 (Edition 1) Page 23 of 48 Pages Test setup for radiated emission measurement 9 kHz – 30 MHz Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50235-060611-3 (Edition 1) Page 24 of 48 Pages Test setup for radiated emission measurement (prescan in fully anechoic room) Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50235-060611-3 (Edition 1) Page 25 of 48 Pages Test setup for radiated emission measurement (open field test site) Senton GmbH Aeussere Fruehlingstrasse 45 D-94315 Straubing Test Report No. 50235-060611-3 (Edition 1) Page 26 of 48 Pages Test setup for radiated emission measurement (open field test site) - continued -

Contact Information

Applicant

Juergen Roesch(President)
[email protected]0811/99 88 1-0Fax: 0811/99 88 1-11

Test Firm

TUV SUD Product Service GmbH PS-EMC-STRRainer Heller
[email protected]49-09421-5522-20Fax: 49-09421-5522-99

Technical Specifications

#Rule PartsFrequency RangePower Output
115C13.56 MHz - 13.56 MHz-
Confidentiality
Long Term

Other Applications from Baltech AG

RFID Card Reader - FCC ID OKY12117601A01A - Baltech AG
OKY12117601A01A

RFID Card Reader

Jan 15, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
RFID Card Reader - FCC ID OKY12115100A01A - Baltech AG
OKY12115100A01A

RFID Card Reader

Jan 04, 2023

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
RFID Card Reader - FCC ID OKY10115100A06A - Baltech AG
OKY10115100A06A

RFID Card Reader

Jul 26, 2021

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
IDE-XG-125-USB - FCC ID OKY10089200A03B - Baltech AG
OKY10089200A03B

IDE-XG-125-USB

May 05, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
IDE-XG-MUL-USB - FCC ID OKY10089300A03B - Baltech AG
OKY10089300A03B

IDE-XG-MUL-USB

May 05, 2015

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter