
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Preliminary OEM installation manual FCC ID: OSZ38001M Page 1 of 10 Intersil ISL38001M IEEE 802.11g MiniPCI WLAN Card OEM installation Manual Version 0.1 Preliminary OEM installation manual FCC ID: OSZ38001M Page 2 of 10 Table of Contents 0-INTRODUCTION .................................................................................................... 3 1-OEM INSTALLATION PROCEDURE ................................................................ 3 1.1 INSTALLING THE MINIPCI CARD INTO THE HOST PC NOTEBOOK.................... 3 1.2 INSTALLING THE SOFTWARE DRIVERS................................................................ 3 1.3 WIRELESS LAN INSTALLATION GUIDE LINES AND AUTHORIZATION FOR USE.7 2-REGULATORY INFORMATION ........................................................................ 7 2.1 FCC INFORMATION TO USER............................................................................. 7 2.2 FCC GUIDELINES FOR HUMAN EXPOSURE........................................................ 7 2.3 FCC ELECTRONIC EMISSION NOTICES.............................................................. 7 2.4 FCC RADIO FREQUENCY INTERFERENCE STATEMENT..................................... 8 2.5 EXPORT RESTRICTIONS....................................................................................... 8 2.6 EUROPE - EU DECLARATION OF CONFORMITY................................................. 9 3-TECHNICAL SPECIFICATIONS....................................................................... 10 Preliminary OEM installation manual FCC ID: OSZ38001M Page 3 of 10 0-Introduction The Intersil ISL38001M WLAN NIC is a complete wireless high speed Network Interface Card (NIC). It conforms to the IEEE 802.11g protocol and operates in the 2.45 GHz ISM frequency bands. It provides a complete reference design evaluation platform of hardware and software to system providers or integrators requiring wireless data communications capability and is ideal for integration into computer platforms. โข Fully compliant with the IEEE 802.11g WLAN standards โข FCC Certified Under Part 15 (pending) to Operate in the 2.45 Bands โข Support for 54, 48, 36, 24, 18, 12, 9, and 6 Mbps OFDM, 11 and 5.5 Mbps CCK and legacy 2 and 1 Mbps data rates โข Driver Supports Microsoft Windows ยฎ 98/SE, ME, XP and 2000 (SR1) 1-OEM Installation procedure 1.0 Host PC Notebook The Intersil ISL38001M WLAN MiniPCI Card is authorized to be installed into the following host PC notebooks: 1โIBM Thinkpad type R30 series 1.1 Installing the miniPCI card into the host PC Notebook a-open miniPCI slot cover of host PC Notebook housing (please observe the necessaru ESD precautions). b-insert miniPCI card into miniPCI slot c-connect the host PC notebook antennas to the miniPCI card antenna connectors (Hirose type UFL connector) d-close miniPCI slot cover of host PC Notebook housing 1.2 Installing the software drivers a-Start windows b-When windows detects new hardware and asks for drivers, point to directory where the Intersil driver is located (for example floppy drive, cdrom , harddisk) to install. c-after drivers are installed, restart windows d-the Intersil WLAN icon will appear in system tray on the bottom right of the screen (see yellow arrow in fig. 01) fig, 01: Intersil WLAN icon Preliminary OEM installation manual FCC ID: OSZ38001M Page 4 of 10 e-double click the Intersil WLAN icon to open the WLAN settings, the following window will appear (see fig.02) fig, 02: Intersil WLAN settings window f-click on configuration tab and select which type of network is required (access point or Peer-to-peer mode), see fig. 03. fig, 03: WLAN network type setting window Preliminary OEM installation manual FCC ID: OSZ38001M Page 5 of 10 g-select what TX rate is required (default setting is fully automatic) see fig. 04. fig, 04: WLAN tx rate setting window h-select what encryption type is required, 64 or 128 bit WEP (default setting is disabled) see fig. 05. fig, 05: WLAN encryption rate setting window Preliminary OEM installation manual FCC ID: OSZ38001M Page 6 of 10 i-click on the status tab to see the connection status (fig.06). fig, 06: WLAN network status j-click on the about tab to see the software drivers versions and MAC address (fig.07). fig, 07: WLAN driver and MAC addres information Preliminary OEM installation manual FCC ID: OSZ38001M Page 7 of 10 1.3 Wireless LAN installation guide lines and Authorization for use Installation and use of this Wireless LAN device must be in strict accordance with the instructions included in the user documentation provided with the product. Any changes or modifications made to this device that are not expressly approved by Intersil may void the userโs authority to operate the equipment. Intersil is not responsible for any radio or television interference caused by unauthorized modification of this device, or the substitution or attachment of connecting cables and equipment other than specified. It is the responsibility of the user to correct any interference caused by such unauthorized modification, substitution or attachment. Intersil and its authorized resellers or distributors will assume no liability for any damage or violation of government regulations arising from failing to comply with these guidelines. The use of Wireless LAN devices may be restricted in some situations or environments for example: * On board of airplanes, or * In an explosive environment, or * In case the interference risk to other devices or services is perceived or identified as harmful. In case the policy regarding the use of Wireless LAN devices in specific organizations or environments (e.g. airports, hospitals, chemical/oil/gas industrial plants, private buildings etc.) is not clear, please first verify authorization to use these devices prior to operating the equipment. 2-Regulatory information 2.1 FCC Information to User This product does not contain any user serviceable components and is to be used with approved antennas only. Any product changes or moโฆ
Text truncated - open the document above for the full version.
TNO Electronic Products & Services (EPS) B.V. Nederlandse Organisatie voor toegepast-natuurwetenschappelijk onderzoek / Netherlands Organisation for Applied Scientific Research Smidshornerweg 18 P.O. Box 15 9822 ZG Niekerk The Netherlands www.tno.nl T +31 594 505005 F +31 594 504804 E [email protected] Subject Cover letter Date May 21, 2003 Our reference 02K1256-3a Your reference - Page 1 of 1 Our General Terms and Conditions, as filed at the Chamber of Commerce in Groningen, are applicable to all orders given to TNO Electronic Products & Services (EPS) B.V. TNO Electronic Products & Services (EPS) B.V. is registered at the Chamber of Commerce in Groningen with no. 27247331. Return address: P.O. Box 15, 9822 ZG Niekerk, The Netherlands Telefication B.V. Attn.: W. Blom Edisonstraat 12a 6902 PK Zevenaar The Netherlands Dear Mr. Blom, On behalf of our customer Intersil Corporation, we hereby would like to apply for FCC certification of the following device: FCC ID : OSZ38001M Brand : Intersil Model number : ISL38001M Description : 2.4 GHz 802.11g WLAN MiniPCI card Type : 2.4 GHz WLAN MiniPCI card The usage of this transmitter will be limited to the following specific host (notebook PC): brand: IBM, model: 2656 (Thinkpad R30 series). The following PDF files (exhibits) are electronically submitted: 1. Cover letter containing the request for FCC certification 2. Request for confidentiality 3. Form 731 4. Test report in conformity with 47 CFR Part 15 5. Bill of materials 6. Circuit diagram 7. Block diagram 8. Operational description 9. Interior photographs 10. Exterior photographs 11. Test setup photographs 12. SAR test report 13. SAR calibration data 14. Authorization letter 15. User manual 16. Label information 17. Antenna information Best regards, TNO Electronic Products & Services (EPS) B.V. P.A.J.M. Robben, B.Sc.E.E. Marketing Manager
TNO Electronic Products & Services (EPS) B.V. Nederlandse Organisatie voor toegepast-natuurwetenschappelijk onderzoek / Netherlands Organisation for Applied Scientific Research Smidshornerweg 18 P.O. Box 15 9822 ZG Niekerk The Netherlands www.tno.nl T +31 594 505005 F +31 594 504804 E [email protected] Subject Request for confidentiality Date May 21, 2003 Our reference 02K1256-3b Your reference - Page 1 of 1 Our General Terms and Conditions, as filed at the Chamber of Commerce in Groningen, are applicable to all orders given to TNO Electronic Products & Services (EPS) B.V. TNO Electronic Products & Services (EPS) B.V. is registered at the Chamber of Commerce in Groningen with no. 27247331. Return address: P.O. Box 15, 9822 ZG Niekerk, The Netherlands Telefication B.V. Attn.: W. Blom Edisonstraat 12a 6902 PK Zevenaar The Netherlands Dear Mr. Blom, Pursuant to section 0.457 of the FCC rules we herewith request the following exhibits, related to this application for FCC ID: OSZ38001M, to be withheld from public inspection and to be kept confidential. The contents of these exhibits may not be disclosed to other parties than Intersil Corporation and TNO Electronic Products & Services (EPS) B.V.: 1. Bill of materials 2. Circuit diagram 3. Operational description 4. Block diagram The reason for this request for confidentiality is that the information contained in the exhibits as listed above has been classified as company confidential. Disclosure of any portion of this information to other parties would cause substantial competitive harm. Best regards, TNO Electronic Products & Services (EPS) B.V. P.A.J.M. Robben, B.Sc.E.E. Marketing Manager
www.intersil.com ING Bank: 65.02.63.049 Swift code: INGBNL2A VAT / BRW: NL8039.66.659.B.01 Chamber of Commerce Utrecht: 30139807 Date 13 May 2003 Your reference -- Our reference 2003-mansup-585d Subject Agent authorization letter for FCC ID: OSZ38001M To whom it may concern To whom it may concern, This letter confirms the agreement that; TNO Electronic Products & Services (EPS) B.V. Smidshornerweg 18 9822 TL Niekerk The Netherlands is authorized as an agent for Company Intersil Corp. The Netherlands Address, City Rembrandtlaan 1a, Bilthoven Country The Netherlands Phone number +31 30 2296060 Fax number +31 30 2296061 and is authorized to sign application forms and act on behalf of Intersil Corp. The Netherlands and is authorized to receive and exchange data between Intersil Corp. The Netherlands and European/non-European national authorities regarding the -certification of- and/or -arranging type approvals for the following product: Intersil model ISL38001M WLAN MiniPCI Card with FCC ID: OSZ38001M This authorization will expire on November, 2003 or upon earlier written notice from Intersil Corp. The Netherlands. Yours sincerely, Derick Sariredjo ( [email protected] ) Intersil Corp. The Netherlands ( www.intersil.com ) Rembrandtlaan 1a, 3723 BG Bilthoven, The Netherlands Phone: +31.30.225.9742 Fax: +31.30.229.6061
FCC ID: OSZ38001M Page 1 of 4 Internal / external photographs of Description: 2.4 GHz IEEE 802.11g WLAN miniPCI Card FCC ID: OSZ38001M Brand name: Intersil Model number: ISL38001M FCC ID: OSZ38001M Page 2 of 4 ISL38001M PCB front with shield FCC ID: OSZ38001M Page 3 of 4 ISL38001M PCB front without shield FCC ID: OSZ38001M Page 4 of 4 ISL38001M PCB rear
FCC ID: OSZ38001M Page 1 of 6 Photographs of IBM notebook PC antennas for Description: 2.4 GHz IEEE 802.11g WLAN MiniPCI Card FCC ID: OSZ38001M Brand name: Intersil Model number: ISL38001M Notebook Host: IBM Thinkpad R30 series FCC ID: OSZ38001M Page 2 of 6 Overview of Host PC of ISL38001M MiniPCI card FCC ID: OSZ38001M Page 3 of 6 Overview of position of embedded 2.4 GHz WLAN antennas of IBM R30 notebook FCC ID: OSZ38001M Page 4 of 6 Detail of 2.4 GHz WLAN dipole antenna mounted on left side of LCD screen Dipole antenna FCC ID: OSZ38001M Page 5 of 6 Detail of 2.4 GHz WLAN Inverted F antenna mounted near LCD screen hinge Inverted F antenna FCC ID: OSZ38001M Page 6 of 6 Overview of ISL38001M card mounted in miniPCI slot on bottom of IBM R30 Detail of ISL38001M card mounted in miniPCI slot of IBM R30
FCC ID: OSZ38001M Page 1 of 3 FCC and CE Label info of Description: 2.4 GHz IEEE802.11g WLAN MiniPCI Card FCC ID: OSZ38001M Brand name: Intersil Model number: ISL38001M FCC ID: OSZ38001M Page 2 of 3 ISL38001M FCC and CE Label Label material: Tamper evident 0.002" polyester. This material is durable, tamper proof and legible. Tamper proof: If the label is removed after 48 hours (time for the adhesive to cure) it will separate which will leave label material on the attached surface that it was removed from. This label material will spell out the word "VOID". The label will also show the word "VOID" where the label material was pulled away. The end result is the word " VOID " on both the mating surface and label, leaving both unusable. FCC ID: OSZ38001M Page 3 of 3 ISL38001M FCC and CE label on Mini PCI Card
FCC ID: OSZ38001M Page 1 of 4 Internal / external photographs of Description: 2.4 GHz IEEE 802.11g WLAN miniPCI Card FCC ID: OSZ38001M Brand name: Intersil Model number: ISL38001M FCC ID: OSZ38001M Page 2 of 4 ISL38001M PCB front with shield FCC ID: OSZ38001M Page 3 of 4 ISL38001M PCB front without shield FCC ID: OSZ38001M Page 4 of 4 ISL38001M PCB rear
CETECOM ICT Services GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken, GermanyPhone: +49 (0) 681 598-0Fax: -8475 SAR-Laboratory Phone: +49 (0) 681 598-8454 . As of May 19, 2003Page 1 of 47 Accredited testing laboratory DAR registration number: TTI-P-G 166/98 Federal Motor Transport Authority (KBA) DAR registration number: KBA-P 00070-97 Test report no. : 4-0990-01-02/03 Type identification: ISL 38001M Test specification : Draft IEEE Std 1528-200X FCC-ID: OSZ38001M Test specification : CETECOM ICT Services GmbH Test report no.: 4-0990-01-02/03 As of May 19, 2003Page 2 of 47 Table of Contents 1General Information............................................................................................................................................................... 3 1.1Notes .............................................................................................................................................................................. 3 1.1.1Statement of Compliance ....................................................................................................................................... 3 1.2Testing laboratory .......................................................................................................................................................... 4 1.3Details of applicant ........................................................................................................................................................ 4 1.4Application details ......................................................................................................................................................... 4 1.5Test item ........................................................................................................................................................................ 5 1.6Test specification(s) ....................................................................................................................................................... 6 1.6.1RF exposure limits ................................................................................................................................................. 6 2Technical test ......................................................................................................................................................................... 7 2.1Summary of test results.................................................................................................................................................. 7 2.2Test environment ........................................................................................................................................................... 7 2.3Measurement and test set-up.......................................................................................................................................... 7 2.4Measurement system...................................................................................................................................................... 8 2.4.1System Description ................................................................................................................................................ 8 2.4.2Test environment ................................................................................................................................................... 9 2.4.3Probe description ................................................................................................................................................... 9 2.4.4Phantom description............................................................................................................................................. 10 2.4.5Device holder description .................................................................................................................................... 10 2.4.6Scanning procedure.............................................................................................................................................. 11 2.4.7Spatial Peak SAR Evaluation............................................................................................................................... 12 2.4.8Data Storage and Evaluation................................................................................................................................ 13 2.4.9Test equipment utilized ........................................................................................................................................ 15 2.4.10Tissue simulating liquids : dielectric properties................................................................................................... 16 2.4.11Tissue simulating liquids : parameters ................................................................................................................. 17 2.4.12Measurement uncertainties .................................................................................................................................. 18 2.4.13System validation................................................................................................................................................. 19 2.4.14Validation procedure............................................................................................................................................ 20 2.5Test results (Body SAR) .............................................................................................................................................. 21 2.5.1Description of test positions during SAR evaluation ........................................................................................... 21 2.6Test results (conducted power measurement) .............................................................................................................. 22 Annex 1System performance verification .....................................โฆ
Text truncated - open the document above for the full version.
CETECOM ICT Services GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken, GermanyPhone: +49 (0) 681 598-0Fax: -8475 SAR-Laboratory Phone: +49 (0) 681 598-8454 . As of May 19, 2003Page 1 of 30 Accredited testing laboratory DAR registration number: TTI-P-G 166/98 Federal Motor Transport Authority (KBA) DAR registration number: KBA-P 00070-97 Calibration data and Phantom information for test report no. 4-0990-1-2/03 Test specification : CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 2 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 3 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 4 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 5 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 6 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 7 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 8 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 9 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 10 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 11 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 12 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 13 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 14 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 15 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 16 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 17 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 18 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 19 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 20 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 21 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 22 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 23 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 24 of 30 CETECOM ICT Services GmbH Calibration Data and Phantom Information; Report No.: 4-0990-1-2/03 As of May 19, 2003Page 25 of 30 Application Note Validation and system Check Purpose of validation The Validation and system check verify that the system operates within ist specifications. System and operator errors can be detected and corrected. It is recommended that the validation be performed prior to any usage of the system in order to guarantee reproducible results. The measurement of the Specific Absorption Rate (SAR) is a complicated task and the resultdepends on the proper functioning of many components and the correct settings of manyparameters. Faulty results due to drift, failures or incorrect parameters might not berecognized, since they often look similar in distribution to the correct ones. The DosimetricAssessment System DASY3 incorporates a validation procedure to test the properfunctioning of the system. The system validation uses normal SAR measurements in asimplified setup (the flat phantom section of the Generic Twin Phantom) with a wellcharacterized source (a matched dipole of a specified distance). This setup was selected to give a high sensitivity to all parameters that might fail or vary over time (e.g. probe, liquid parameters, and software settings) and a low sensitivity to external effects inherent in the system (e.g. positioning uncertainty of the device holder). The validation does not replace the calibration of the components. The accuracy of the validation is not sufficient for calibration purposes. It is possible to calculate the field quite accurately in this simple setup; however, due to the open field situation some factors (e.g. laboratory reflections) cannot be accounted for. Calibrations in the flat phantom are possible with transfer calibration methods, using either temperature probes or calibrated E-field probes. The validation also does not test the system performance for arbitrary field situations encountered during real measurements of mobile phones. These checks are performed at SPEAG by testing the components under various conditions (e.g. spherical isotropy measurements in liquid, linearity measurements, temperature variations, etc.), the results of which are used for an error estimation of the system. The validation will indicate situations where the system uncertainty is exceeded due to drift or failure. Validation procedure Preparation The conductivity should be measured before the validation and the measured liquid parameters must be entered in the software. If the measured values differ from targeted values in the dipole document, the liquid composition should be adjusted. If the โฆ
Text truncated - open the document above for the full version.
Testing and certification of, consultancy and research concerning, electronic and electric appliances, systems, installations and telecommunication systems TNO Electronic Products & Services (EPS) B.V. P.O. Box 15 9822 ZG Niekerk (NL) Smidshornerweg 18 9822 TL Niekerk (NL) Telephone: +31 594 505005 Telefax: +31 594 504804 E-mail: [email protected] Project number: 03042802.r01 Page 1 of 58 TEST REPORT OF A 2.4 GHZ 802.11g WLAN MINIPCI CARD, BRAND INTERSIL, MODEL ISL38001M, IN CONFORMITY WITH 47 CFR PART 15 (2002-08-23). FCC listed Industry Canada : : 90828 IC3501 Test specification(s): Description of EUT: Manufacturer: Brand mark: Model: FCC ID: 47 CFR Part 15 (2002-08-23) 2.4 GHz 802.11g WLAN MiniPCI card Intersil Corporation Intersil ISL38001M OSZ38001M Project number: 03042802.r01 Page 2 of 58 MEASUREMENT/TECHNICAL REPORT Intersil Corporation Model : ISL38001M FCC ID: OSZ38001M May 20, 2003 This report concerns: Original grant/certification Class 2 change Verification Equipment type: Digital Transmission System Deferred grant requested per 47 CFR 0.457(d)(1)(ii) ? Yes No Report prepared by: Name : P.A.J.M. Robben, B.Sc.E.E. Company name : TNO Electronic Products & Services (EPS) B.V. Address : Smidshornerweg 18 Postal code/city : 9822 ZG Niekerk Mailing address : P.O. Box 15 Postal code/city : 9822 TL Niekerk Country : The Netherlands Telephone number : + 31 594 505 005 Telefax number : + 31 594 504 804 E-mail : [email protected] The data taken for this test and report herein was done in accordance with 47 CFR Part 15 and the measurement procedures of ANSI C63.4-1992. TNO Electronic Products & Services (EPS) B.V. at Niekerk, The Netherlands, certifies that the data is accurate and contains a true representation of the emission profile of the Equipment Under Test (EUT) on the date of the test as noted in the test report. I have reviewed the test report and find it to be an accurate description of the test(s) performed and the EUT so tested. Date: May 20, 2003 Signature: P. de Beer TNO Electronic Products & Services (EPS) B.V. Test specification(s): Description of EUT: Manufacturer: Brand mark: Model: FCC ID: 47 CFR Part 15 (2002-08-23) 2.4 GHz 802.11g WLAN MiniPCI card Intersil Corporation Intersil ISL38001M OSZ38001M Project number: 03042802.r01 Page 3 of 58 Description of test item Test item : 2.4 GHz 802.11g WLAN MiniPCI card Manufacturer : Intersil Corporation Brand : Intersil Model : ISL38001M Serial numbers : 03110062 Revision : n.a. Receipt number : 1 Receipt date : May 6, 2003 Applicant information Applicant's representative : Mr. D. Sariredjo Company : Intersil Corporation Address : Rembrandtlaan 1a Postal code : 3723 BG City : Bilthoven PO-box : 343 Postal code : 3720 AH City : Bilthoven Country : The Netherlands Telephone number : +31 30 2259742 Telefax number : +31 30 2296061 Test(s) performed Location : Niekerk Test(s) started : May 6, 2003 Test(s) completed : May 9, 2003 Purpose of test(s) : Type approval / certification Test specification(s) : 47 CFR Part 15 (2002-08-23) Test engineer : O.H. Hoekstra Report written by : P.A.J.M. Robben, B.Sc.E.E. Project leader : P.A.J.M. Robben, B.Sc.E.E. This report is in conformity with NEN-EN-ISO/IEC 17025. This report shall not be reproduced, except in full, without the written permission of TNO Electronic Products & Services (EPS) B.V. The test results relate only to the item(s) tested. Test specification(s): Description of EUT: Manufacturer: Brand mark: Model: FCC ID: 47 CFR Part 15 (2002-08-23) 2.4 GHz 802.11g WLAN MiniPCI card Intersil Corporation Intersil ISL38001M OSZ38001M Project number: 03042802.r01 Page 4 of 58 Table of contents 1 General information ...............................................................................................................................................................6 1.1 Product description.........................................................................................................................................................6 1.2 Related submittal(s) and/or Grant(s) ..............................................................................................................................6 1.3 Tested system details......................................................................................................................................................6 1.4 Test methodology ...........................................................................................................................................................7 1.5 Test facility.....................................................................................................................................................................7 1.6 Product labeling....................................................โฆ
Text truncated - open the document above for the full version.
Smidshornerweg 18 ยท Niekerk ยท Netherlands
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 78.00 mW |

2.4/5 GHz IEEE 802.11g/a WLAN Cardbus card
Equipment Class
NII - Unlicensed National Information Infrastructure TX
2.4/5 GHz IEEE 802.11g/a WLAN Cardbus card
Equipment Class
DTS - Digital Transmission System
2.4/5 GHz IEEE 802.11g/a WLAN Cardbus card
Equipment Class
DTS - Digital Transmission System
2.4 GHz/5 GHz IEEE 802.11a/g WLAN MiniPCI card
Equipment Class
NII - Unlicensed National Information Infrastructure TX
5 GHz IEEE 802.11a WLAN MiniPCI card
Equipment Class
NII - Unlicensed National Information Infrastructure TX