FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Xanboo, Inc./
  3. OU4-XPC240

OU4-XPC240XPC240 Power Module

Xanboo, Inc.
XPC240 Power Module - FCC ID OU4-XPC240 - Xanboo, Inc.
Click to zoom

Application Details

Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
Date of Grant
May 18, 2004
Application Purpose
Original Equipment
Date of Application
May 18, 2004
Equipment Note
XPC240 Power Module
Frequency Range
418.00000000 - 418.00000000
Company
Xanboo, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Block Diagram

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Exhibit J: Users Manual Xanboo XPC240 Power Module

Block Diagram

Exhibit F: Block Diagram Xanboo XPC240 Power Module

Cover Letter(s)

Exhibit K: Letter of Confidentiality Xanboo XPC240 Power Module

Cover Letter(s)

Exhibit I: Letter of Authorization Xanboo XPC240 Power Module

External Photos

Exhibit E1 – External EUT Photos Xanboo XPC240 Power Module Xanboo XPC Power Module Xanboo XPC Power Module

ID Label/Location Info

Exhibit C: Label Location Xanboo XPC240 Power Module Xanboo XPC240 Power Module

Internal Photos

Exhibit E2 – Internal EUT Photos Xanboo XPC240 Power Module Xanboo XPC240 Power Module Xanboo XPC240 Power Module Xanboo XPC240 Power Module

Test Report

Professional Testing (EMI), Inc. Report No. 04445-10 Page 1 of 20 Exhibit B: Test Report Xanboo, Inc. XPC240 Power Module Professional Testing (EMI), Inc. Report No. 04445-10 Page 2 of 20 Project Number: 04445-10 Prepared for: Xanboo, Inc. 400 Columbus Avenue Valhaua , New York 10595 By Professional Testing (EMI), Inc. 1601 FM 1460, Suite B Round Rock, Texas 78664 May 2004 CERTIFICATION Electromagnetic Interference Test Report Xanboo, Inc. XPC240 Power Module (Intentional Radiator Portion) Professional Testing (EMI), Inc. Report No. 04445-10 Page 3 of 20 Table of Contents Title Page .........................................................................................................................................1 Table of Contents .............................................................................................................................2 Certificate of Compliance ................................................................................................................3 Table of Contents .............................................................................................................................3 1.0 EUT Description ..................................................................................................................5 1.1 EUT Operation.....................................................................................................................5 2.0 Electromagnetic Emissions Testing.....................................................................................5 2.1 Conducted Emissions Measurements ..............................................................................5 2.1.1 Test Procedure .........................................................................................................6 2.1.2 Test Criteria .............................................................................................................6 2.1.3 Test Results ..............................................................................................................6 2.2 Radiated Emissions Measurements .................................................................................6 2.2.1 Test Procedure .........................................................................................................7 2.2.2 Test Criteria .............................................................................................................7 2.2.3 Test Results ..............................................................................................................7 3.0 Occupied Bandwidth Measurements ...................................................................................8 3.2 Test Criteria .....................................................................................................................8 3.3 Test Results ......................................................................................................................8 4.0 Antenna Requirement ..........................................................................................................8 4.1 Evaluation Procedure .......................................................................................................8 4.3 Evaluation Results ...........................................................................................................9 5.0 Modifications to Equipment ..............................................................................................10 6.0 List of Test Equipment.......................................................................................................10 Figures FIGURE 1: Conducted Emissions Mains Terminal Measurements ............................................. 11 FIGURE 2: Radiated Emissions Test Setup ................................................................................. 12 Appendices Appendix A: Emissions Data Sheet ...............................................................................................13 Appendix B: Occupied Bandwidth Data Sheets............................................................................. 18 THIS REPORT SHALL NOT BE REPRODUCED EXCEPT IN FULL, WITHOUT THE WRITTEN APPROVAL OF PROFESSIONAL TESTING (EMI), INC. Professional Testing (EMI), Inc. Report No. 04445-10 Page 4 of 20 Applicant: Xanboo, Inc. Applicant’s Address: 400 Columbus Avenue Valhaua, New York 10595 FCC ID: OU4-XPC240 Project Number: 04445-10 Test Dates: April 14, 2004 and April 15, 2004 I, Jeffrey A. Lenk, for Professional Testing (EMI), Inc., being familiar with the FCC rules and test procedures have reviewed the test setup, measured data and this report. I believe them to be true and accurate. The Xanboo, Inc., XPC240 Power Module was tested to and found to be in compliance with FCC Part 15 Subpart C for an Intentional Radiator. The highest emissions generated by the above equipment are listed below: Frequency (MHz) Level (dBμV/m) Limit (dBμV/m) Margin (dB) Fundamental 418 66.5 72.3 -5.8 Spurious 4940 44.7 52.3 -7.6 Conducted 0.15 44.1 66.0 -21.9 Occupied Bandwidth 128 (kHz) 1.045 (MHz) ______________________________ Jeffrey A. Lenk President This report has been reviewed and accepted by Xanboo, Inc.. The undersigned is responsible for ensuring that Xanboo, Inc., XPC240 Power Module will continue to comply with the FCC rules. Certificate Of Compliance Professional Testing (EMI), Inc. Report No. 04445-10 Page 5 of 20 1.0 EUT Description The XPC240 Power Module (EUT) is used to remotely control or determine the status of 120 VAC appliances. In Mode 1, the unit can notify the Xanboo system that an appliance, security light, computer, etc. has been turned on. When the appliance is activated, the unit transmits its unique ID number to the Xanboo unit on 418 MHz. In Mode 2, the XPC240 can be used by the Xanboo system to turn on and turn off appliances, security lights, etc. The 418 MHz signal is a 19mS long transmission uniquely identifying the sending station. The transmiss…

Text truncated - open the document above for the full version.

Test Setup Photos

Exhibit D – Test Setup Photographs Xanboo XPC240 Power Module Xanboo XPC240 Power Module Conducted Emissions Test Setup Xanboo XPC240 Power Module Conducted Emissions Test Setup Xanboo XPC240 Power Module Radiated Emissions Test Setup

Contact Information

Applicant

Kent E Britain(Sr. RF Engineer)
[email protected]972-660-2810Fax: 972-606-1909

Technical Contact

Professional Testing (EMI) Inc.Mike Royer
[email protected](512) 244 3371

1601 FM 1460, Suite B · Round Rock, Texas · United States

Test Firm

Professional Testing (EMI), Inc.Michael Royer
[email protected]5122443371Fax: 5122441846

Technical Specifications

#Rule PartsFrequency RangePower Output
115.231(e)418 MHz - 418 MHz-
Confidentiality
Long Term

Other Applications from Xanboo, Inc.

WIFI GATEWAY - FCC ID OU4-XG1000S-W - Xanboo, Inc.
OU4-XG1000S-W

WIFI GATEWAY

Jun 27, 2010

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
FIRST ALERT BRIDGE - FCC ID OU4-XCB80-FA - Xanboo, Inc.
OU4-XCB80-FA

FIRST ALERT BRIDGE

Feb 21, 2010

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
LAMP   DIMMER - FCC ID OU4XPC260 - Xanboo, Inc.
OU4XPC260

LAMP DIMMER

Mar 21, 2007

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
GARAGE DOOR CONTROL - FCC ID OU4XPC280 - Xanboo, Inc.
OU4XPC280

GARAGE DOOR CONTROL

Mar 21, 2007

Equipment Class

DSC - Part 15 Security/Remote Control Transmitter
OU4XG1000

XANBOO REMOTE MONITORING AND ACCESS GATEWAY

Jul 12, 2006

Equipment Class

DSR - Part 15 Remote Control/Security Device Transceiver