Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Product Information Management Marketing Sales of new Cars Aftersales Sales of used Cars Administration Product description The “Telematics Platform Accessory” (TPA) is the name given to the system installed anonymously (i.e. it is undetectable from the outside) into the vehicle that forms the basis for various services. To this end, TPA establishes a GSM connection between the vehicle and a central server via which information can be exchanged. By doing this, the TPA facilitates a broad spectrum of application options that can be converted into services for the customer. These services are dened by and oered to the customer as a service package by the individual BMW subsidiaries in cooperation with local service providers who provide the appropriate infrastructure. These packages are therefore local products that can vary from market to market. The following services packages are currently available: •Stolen Vehicle Tracking/Recovery including an optional driver authorisation performed via transponders. •Log book/eet management, i.e. the date, time, location and distance travelled is documented for each journey. •Vehicle position query from the customer. •Triggering of an automatic call to the emergency services (non-verbal) in the event of an accident. •Recording of insurance-relevant usage data, including accident data recording (pre- and post- crash). When certain services are used, some insurance companies oer discounts. These discount rules depend on the service packages available locally and the service portfolios of the individual insur- ance companies, and can therefore vary tremen- dously. In individual cases, the customer should ask their insurance company directly about these services. Sales features/benets •BMW-tested hardware (electromagnetic com- patibility, vehicle electrical system connection, standby current consumption, etc.). •Platform system for capturing safety-related information (theft, logbook/eet management, insurance-relevant usage data). •WEB-based customer access to various data and services. •Discounts on insurance premiums (depending on the insurance company and the services taken). •Stolen Vehicle Tracking/Recovery (SVR): •Satises all currently applicable European standards. •Theft alarm by the customer or through the sensors built into the car. •Tracking and function blocking of a stolen vehicle. •In some cases this is a prerequisite for acceptance of a theft insurance policy. Note The hardware can only be used in conjunction with a service agreement which incurs additional costs. Please nd out in advance from your sales company whether a local service provider is available and what service packages are oered! (continued on page 2) Accessories April 2009 Aftersales/Accessories/Infotainment and Communication/Communication in general PI: SZ_041_04_09 BMW Group Telematics Platform Accessory TPA – BMW E 53, E 60, E 61,E 63, E 64, E 65, E 66, E 67, E 70, E 71, E 72, E 81, E 82, E 83, E 84, E 85, E 86, E 87, E 88, E 89, E 90, E 91, E 92, E 93, F01, F02, F03, F04, F07, F10, F11 – MINI R 55, R56, R57 Supplied package • The retrofit kit contains the wiring harness required for installation, the GSM and GPS aerial and various small parts required for the installation of the system. • The TPA control unit must be ordered separately and comprises the following modules: • GSM module with integrated SIM card • GPS receiver • Integrated back-up battery • Vehicle bus interface • Radio receiver for transponders • Optionally, up to 8 transponders (radio key for driver authorisation) can be used per car. Availability since 04/2007 Installation time The installation time is approx. 2,5 hours, but this may vary depending on the condition of the car and the equipment in it. EPC DVD from 04/2007 Installation instructions see BMW Aftersales Assistance Portal (ASAP) Part number The following workshop equipment will also be required (one for each dealership) for TPA pro- gramming/coding: BMW01 29 0 429 160 MINI01 29 0 429 161 TPA retrofit kit 84 10 0 428 480 TPA control unit: – ECE84 10 0 441 998 – Mexico84 10 2 154 189 Transponders for SVR 84 10 0 428 486 Programming system84 10 0 429 159 Telematics Platform Accessory TPA – BMW E 53, E 60, E 61, E 63, E 64, E 65, E 66, E 67, E 70, E71, E 72, E 81, E 82, E 83, E 84, E 85, E 86, E 87, E 88, E 89, E 90, E 91, E 92, E 93, F01, F02, F03, F04, F07, F10, F11 – MINI R 55, R 56, R 57 Please refer to your price system or the latest price publica- tions for the latest prices. This device complies with Part 15 of the FCC rules subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept all interference received, including interference that may cause undesired operation.” FCC ID: P3O96902
Eurofins Product Service External Photos page 1 Model No.: TPA GEN.2 FCC ID: P3O96902 Project No.: E7M21001-2817 Eurofins Product Service GmbH Storkower Str. 38C, D-15526 Reichenwalde, Germany Eurofins Product Service External Photos page 2 Model No.: TPA GEN.2 FCC ID: P3O96902 Project No.: E7M21001-2817 Eurofins Product Service GmbH Storkower Str. 38C, D-15526 Reichenwalde, Germany
Eurofins Product Service Internal Photos page 1 Model No.: TPA GEN.2 FCC ID: P3O96902 Project No.: E7M21001-2817 Eurofins Product Service GmbH Storkower Str. 38C, D-15526 Reichenwalde, Germany Eurofins Product Service Internal Photos page 2 Model No.: TPA GEN.2 FCC ID: P3O96902 Project No.: E7M21001-2817 Eurofins Product Service GmbH Storkower Str. 38C, D-15526 Reichenwalde, Germany
TEST REPORT File name: ~WRO2531 Pag. 1 of 9 DVP-S112.DOC 25/07/2002 REV.000 GSM ANTENNAS COMPARISON 1. INDICE 1.1. GENERAL INFORMATION ................................................................................................................................. 2 1.2. TEST EQUIPMENTS............................................................................................................................................. 2 1.3. TEST SET-UP ........................................................................................................................................................ 3 1.3.1. TEST DETAILS .............................................................................................................................................4 1.4. COMPARISON GRAPHS ..................................................................................................................................... 6 1.4.1. GAIN GRAPH f=900MHz ............................................................................................................................ 6 1.4.2. GAIN GRAPH f=1750MHz ........................................................................................................................... 7 1.4.3. FREQUENCY BAND GRAPH f=900MHz ................................................................................................... 8 1.4.4. FREQUENCY BAND GRAPH f=1750MHz ................................................................................................. 9 1.5. TEST RESULTS .................................................................................................................................................... 9 SIGNATURE SIMONE CASTAGNETTI TEST REPORT File name: ~WRO2531 Pag. 2 of 9 DVP-S112.DOC 25/07/2002 REV.000 1.1. GENERAL INFORMATION Product description n° 1 Meta System GSM antenna, n° 2 Distar GSM antennas, n° 2 CIA GSM antennas, n° 1 Richardson Electronics GSM antenna Serial n° n.a. GSM antennas comparison Test type ref. Meta System Test started 12/05/08 Test finished 12/05/08 Tested by Simone Castagnetti 1.2. TEST EQUIPMENTS TYPE MODEL META SYSTEM INTERNAL CODE Digital multimeter FLUKE 175 S0945 Signal generator ROHDE & SCHWARZ SMY 02 S0845 PC G@VI COMPUTERS PC620 Spectrum analyzer AGILENT E4407B S0995 Anechoic chamber FRANKONIA S0939 Horn antenna AR AT4510 S0895 TEST REPORT File name: ~WRO2531 Pag. 3 of 9 DVP-S112.DOC 25/07/2002 REV.000 1.3. TEST SET-UP TEST REPORT File name: ~WRO2531 Pag. 4 of 9 DVP-S112.DOC 25/07/2002 REV.000 1.3.1. TEST DETAILS Horn Antenna Meta System GSM Antenna Richardson Electronics GSM Antenna . TEST REPORT File name: ~WRO2531 Pag. 5 of 9 DVP-S112.DOC 25/07/2002 REV.000 Distar n°1 and 2 GSM Antennas CIA n°1 and 2 GSM Antennas TEST REPORT File name: ~WRO2531 Pag. 6 of 9 DVP-S112.DOC 25/07/2002 REV.000 1.4. COMPARISON GRAPHS 1.4.1. GAIN GRAPH f=900MHz -90 -80 -70 -60 -50 -40 -30 -20 -10 0 -100-80-60-40-20020 Input (dBm) Output (dBm) META SYSTEM DISTAR1 DISTAR2 CIA1 CIA2 RICHARDSON TEST REPORT File name: ~WRO2531 Pag. 7 of 9 DVP-S112.DOC 25/07/2002 REV.000 1.4.2. GAIN GRAPH f=1750MHz -100 -90 -80 -70 -60 -50 -40 -30 -20 -10 0 -100-80-60-40-20020 Input (dBm) Output (dBm) META SYSTEM DISTAR1 DISTAR2 CIA1 CIA2 RICHARDSON TEST REPORT File name: ~WRO2531 Pag. 8 of 9 DVP-S112.DOC 25/07/2002 REV.000 1.4.3. FREQUENCY BAND GRAPH f=900MHz -90 -85 -80 -75 -70 -65 -60 -55 820840860880900920940960 Frequency (MHz) Output (dBuV) META SYSTEM DISTAR1 DISTAR2 CIA1 CIA2 RICHARDSON TEST REPORT File name: ~WRO2531 Pag. 9 of 9 DVP-S112.DOC 25/07/2002 REV.000 1.4.4. FREQUENCY BAND GRAPH f=1750MHz -80 -75 -70 -65 -60 -55 -50 -45 1700175018001850190019502000 Frequency (MHz) Output (dBuV) META SYSTEM DISTAR1 DISTAR2 CIA1 CIA2 RICHARDSON 1.5. TEST RESULTS Richardson Electronics antenna is the worst between those tested. Meta System and Distar antenna are comparable but Distar antennas are slightly better.
Mr. Armellini, I confirm you that the external antenna gain at FCC frequency is -2.1dBi, like indicated in FCC.TR.08.1019 issued 21/10/2008 Regard Giorgio Maldini R&D Homologation Manager. Meta System S.p.A. MetaSystem Group www.metasystem.it Via Galimberti 9 42124 Reggio Emilia Tel. +39 0522 364111 Fax +39 0522 364122 e-mail [email protected]
31 Page 1 of 3 Prima Ricerca & Sviluppo Srl. – C.I. 026347801 Sede legale : 22100 Tavernola (CO) Via Conciliazione, 1 Cod. FISC. e N. R.I. CO 02635860139 Sede operativa : Laboratori Via Campagna, 92 22020 Faloppio fraz. Gaggino (CO) Tel. +39 03135000.11 Fax +39 031991309 MPE CALCULATION APPLICANT: META SYSTEM S.p.A. Via Majakovskij 10/b/c/d/e - 42124 Reggio Emilia - Italy EUT DESCRIPTION GSM-GPS CONTROL UNIT EUT TRADEMARK META SYSTEM S.p.A. EUT MODEL TPA Gen2 REFERENCE STANDARDS : FCC RULES PART 22 and 24 DATE OF ISSUE 30/03/2010 LABORATORY Prima Ricerca & Sviluppo S.r.l. Via Campagna, 92 -22020 Faloppio (Co) –Italy ISSUED BY Giacomo Armellini The calculation results reported in this document shall refer only to Test Report above indicated and relevant tested sample 32 Page 2 of 3 Prima Ricerca & Sviluppo Srl. – C.I. 026347801 Sede legale : 22100 Tavernola (CO) Via Conciliazione, 1 Cod. FISC. e N. R.I. CO 02635860139 Sede operativa : Laboratori Via Campagna, 92 22020 Faloppio fraz. Gaggino (CO) Tel. +39 03135000.11 Fax +39 031991309 Test Report reference FCCTR_090921-5 issued 30/03/2010 by Prima Ricerca & Sviluppo 22345 RET Issued 29/11/2005 by CETECOM GSM 850 Internal Antenna Not applicable: the frequency range of the Internal Antenna is 880-960 MHz (declared by the manufacturer) GSM 850: Channel 128 External Antenna (Worst Case) Calculation Results Conducted Antenna Connector Radiated Power at the Antenna 2.06 W 1,552 W Antenna Gain in dB -2,1 dBi n.a. Distance to the Area of Interst 0.656 feet 0.1999 metres 0.656 feet 0.1999 metres Frequency of Operation 824,12 MHz 824,12 MHz Are Ground reflections Calculated Yes n.a. Estimated RF Power Density 0.252 mW/cm 2 0.309 mW/cm 2 Controlled Environment Uncontrolled Environment Controlled Environment Uncontrolled Environment Maximum Permissible Exposure (MPE) 2.7521 mW/cm 2 0.5544 mW/cm 2 2.7521 mW/cm 2 0.5544 mW/cm 2 Distance to Compliance From Centre of Antenna 0.2487 feet 0.0758 metres 0.4943 feet 0.1507 metres 0.27 feet 0.0823 metres 0.5419 feet 0.1652 metres Does the Area of Interest Appear to be in Compliance yes yes yes yes 33 Page 3 of 3 Prima Ricerca & Sviluppo Srl. – C.I. 026347801 Sede legale : 22100 Tavernola (CO) Via Conciliazione, 1 Cod. FISC. e N. R.I. CO 02635860139 Sede operativa : Laboratori Via Campagna, 92 22020 Faloppio fraz. Gaggino (CO) Tel. +39 03135000.11 Fax +39 031991309 PCS 1900: Channel 512 Internal Antenna (worst case) Conducted Antenna Connector Radiated Power at the Antenna 0.9 W 0.579 W Antenna Gain in dB 1 dBi n.a. Distance to the Area of Interst 0.656 feet 0.1999 metres 0.656 feet 0.1999 metres Frequency of Operation 1850.335MHz 1850.335MHz Are Ground reflections Calculated Yes n.a. Estimated RF Power Density 0.2256 mW/cm 2 0.1153 mW/cm 2 Controlled Environment Uncontrolled Environment Controlled Environment Uncontrolled Environment Maximum Permissible Exposure (MPE) 5.005 mW/cm 2 1.005 mW/cm 2 5.005 mW/cm2 1.005 mW/cm2 Distance to Compliance From Centre of Antenna 0.1893 feet 0.0577 metres 0.3615 feet 0.1102 metres 0.1496 feet 0.0456 metres 0.2727 feet 0.0831 metres Does the Area of Interest Appear to be in Compliance yes yes yes yes
FCCTR TEST REPORT 090921-5 Prima Ricerca & Sviluppo Srl soggetta a direzione e coordinamento da parte della Giovanni Maspero & C. S.p.A. – C.I. 02634780130 Sede legale : 22100 Tavernola (CO) Via Conciliazione, 1 Cod. FISC. e N. R.I. CO 02635860139 Sede operativa : Laboratori Via Campagna, 92 22020 Faloppio fraz. Gaggino (CO) Tel. +39 03135000.11 Fax +39 031991309 Issue date:30/03/2010 sheet 1 of 37 EQUIPMENT UNDER TEST : APPARECCHIO IN PROVA : Telematics Platform Accessory TPA TPA Gen2 REFERENCE STANDARDS: NORME DI RIFERIMENTO : FCC RULES PART 22 and 24 Customer: RICHIEDENTE: • Dept. / Firm : Ente / Società’: META SYSTEM S.p.A. • Mr.: Sig.: Maldini • Address: Indirizzo: Via Majakovskij 10/b/c/d/e - 42124 Reggio Emilia - Italy • Tel. : Telefono : +39 0522 364111 • Telefax: Fax : +39 0522 308382 • E-mail: [email protected] Site of test execution: Via Campagna, 92 - 22020 Gaggino Faloppio (CO) - Italy Località esecuzione prove: Date of test samples receipt: 31/08/09 Date of start test: 30/09/2009 Data ricevimento campioni: Data inizio prove: Date of end test: 16/03/2010 Data fine prove: Witness to the test: Presenti alle prove: Signature of the engineers: Firma esecutore prove: Approvato da: Approved by: Nobody / Nessuno ......................................................... .......................................................... Giacomo Armellini .......................................................... Giovanni Molteni The test results recorded in this Test Report are exclusively referred to the tested samples. I risultati del presente rapporto di prova si riferiscono esclusivamente al campione sottoposto a prova. Reproduction of this EMC-Test Report in whole or in part is prohibited without the written authorization of the Laboratory Director La riproduzione di questo Rapporto in modo parziale o totale è PROIBITO senza l’autorizzazione scritta della Direzione del Laboratorio FCCTR TEST REPORT 090921-5 Prima Ricerca & Sviluppo Srl soggetta a direzione e coordinamento da parte della Giovanni Maspero & C. S.p.A. – C.I. 02634780130 Sede legale : 22100 Tavernola (CO) Via Conciliazione, 1 Cod. FISC. e N. R.I. CO 02635860139 Sede operativa : Laboratori Via Campagna, 92 22020 Faloppio fraz. Gaggino (CO) Tel. +39 03135000.11 Fax +39 031991309 Issue date:30/03/2010 sheet 2 of 37 0. CONTENTS Page 0. CONTENTS ........................................................................................................... 2 1. TECHNICAL INFORMATION OF EQUIPMENT UNDER TEST (EUT) .................. 3 1.1 Identification ................................................................................................... 3 1.2 Technical data ................................................................................................ 3 1.3 Modifications incorporated in E.U.T. ............................................................... 4 1.4 Ports identification ........................................................................................... 4 1.5 Auxiliary equipment........................................................................................ 4 2. TEST CONDITIONS .............................................................................................. 5 2.1 Operating test modes and test conditions...................................................... 5 3. Summary of test results ......................................................................................... 6 3.1 Tests............................................................................................................... 6 4. TEST RESULTS .................................................................................................... 7 5. LIST OF EQUIPMENT USED ...............................................................................39 6 .Photographic documentation ...............................................................................40 FCCTR TEST REPORT 090921-5 Prima Ricerca & Sviluppo Srl soggetta a direzione e coordinamento da parte della Giovanni Maspero & C. S.p.A. – C.I. 02634780130 Sede legale : 22100 Tavernola (CO) Via Conciliazione, 1 Cod. FISC. e N. R.I. CO 02635860139 Sede operativa : Laboratori Via Campagna, 92 22020 Faloppio fraz. Gaggino (CO) Tel. +39 03135000.11 Fax +39 031991309 Issue date:30/03/2010 sheet 3 of 37 1. TECHNICAL INFORMATION OF EQUIPMENT UNDER TEST (EUT) 1.1 Identification Brand name: META SYSTEM S.P.A. Manufacturer: META SYSTEM S.P.A. Equipment : GSM-GPS CONTROL UNIT Model name : TPA Gen2 Country of manufacturer: ITALY 1.2 Technical data FCC class: FCC RULES PART 22 and 24 FCC ID: P3O96902 Supply voltage: 12 Vdc EUT standing: Car power supply EUT single or system: Single EUT dimensions : See photographic documentation GSM module manufacturer Telit Communications SpA Module type : GE864 QUAD Type of antenna : Integral External Dedicated Frequency range TX - GSM 850 824.2 – 848.80 MHz Frequency range TX - PCS 1850.2 – 1909.8 MHz Frequency range RX – GSM 850 869.2 – 893.8 MHz Frequency range RX – PCS 1930.2 – 1989.8 MHz External Antenna gain 810 - 960 MHz → -2.1dBi 1710 – 1990 MHz → -2.1dBi Dedicated Antenna gain 880-960 MHz → 1dBi 1710 – 1990 MHz → 1dBi Power supply 3.22 – 4.5 Vdc (3,8 Vdc recommended) Operating mode Duplex Type of modulation GMSK (GSM modulation) Emission GXW Software Fully GSM software Stack Temperature range Operating: -40°C to +85°C Storage: -40°C to +85°C FCCTR TEST REPORT 090921-5 Prima Ricerca & Sviluppo Srl soggetta a direzione e coordinamento da parte della Giovanni Maspero & C. S.p.A. – C.I. 02634780130 Sede legale : 22100 Tavernola (CO) Via Conciliazione, 1 Cod. FISC. e N. R.I. CO 02635860139 Sede operativa : Laboratori Via Campagna, 92 22020 Faloppio fraz. Gaggino (CO) Tel. +39 03135000.11 Fax +39 031991309 Issue date:30/03/2010 sheet 4 of 37 1.3 Modifications incorporated in E.U.T. The following items are the modifications introduced in the equipment under test : • None 1.4 Ports identification This section contains …
Text truncated - open the document above for the full version.
Report No.: 22345RET Date: 2005-11-29 Page: 2 of 10 FDT08_04 INDEX 1. COMPETENCE AND GUARANTEES..........................................................................................3 2. GENERAL CONDITIONS..............................................................................................................3 3. CHARACTERISTICS OF THE TEST............................................................................................3 3.1 TEST REQUESTED.................................................................................................................3 3.2 REQUIREMENTS AND METHOD........................................................................................4 4. IDENTIFICATION DATA SUPPLIED BY THE APPLICANT.....................................................5 4.1 APPLICANT.............................................................................................................................5 4.2 REPRESENTATIVE................................................................................................................5 4.3 TEST SAMPLES SUPPLIER...................................................................................................5 4.4 IDENTIFICATION OF ITEM/ITEMS TESTED.....................................................................6 5. USAGE OF SAMPLES, PERIOD OF TESTING AND ENVIRONMENTAL CONDITIONS.....6 5.1 USAGE OF SAMPLES............................................................................................................6 5.2 PERIOD OF TESTING............................................................................................................7 5.3 ENVIROMENTAL CONDITIONS..........................................................................................7 6. TEST RESULTS..............................................................................................................................9 7. REMARKS AND COMMENTS......................................................................................................9 8. SUMMARY....................................................................................................................................10 ANNEXES ANNEX A. TEST RESULTS FOR FCC PART 22 ANNEX B. TEST RESULTS FOR FCC PART 24 ANNEX C. MEASURING RESULTS FOR ELECTROMAGNETIC EMISSION ANNEX D. PHOTOGRAPHS Report No.: 22345RET Date: 2005-11-29 Page: 3 of 10 FDT08_04 1. COMPETENCE AND GUARANTEES Centro de Tecnología de las Comunicaciones (CETECOM), S.A. is a laboratory with a measurement facility in compliance with the requirements of Section 2.948 of the FCC rules and has been added to the list of facilities whose measurements data will be accepted in conjunction with applications for Certification under Parts 15 or 18 of the Commission's Rules. Registration Number: 905266. Centro de Tecnología de las Comunicaciones (CETECOM), S.A. is a laboratory with a measurement site in compliance with the requirements of RSS 212, Issue 1 (Provisional) and has been added to the list of filed sites of the Canadian Certification and Engineering Bureau. Reference File Number: IC 4621. In order to assure the traceability to other national and international laboratories, CETECOM has a calibration and maintenance programme for its measuring equipment. CETECOM guarantees the reliability of the data presented in this report, which is the result of measurements and tests performed to the item under test on the date and under the conditions stated on the report and is based on the knowledge and technical facilities available at CETECOM at the time of execution of the test. CETECOM is liable to the client for the maintenance by its personnel of the confidentiality of all information related to the item under test and the results of the test. 2. GENERAL CONDITIONS 1. This report only refers to the item that has undergone the test. 2. This report does not constitute or imply by its own an approval of the product by the Certification Bodies or competent Authorities. 3. This document is only valid if complete; no partial reproduction can be made without written approval of CETECOM. 4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous written approval of CETECOM and the Accreditation Bodies. 3. CHARACTERISTICS OF THE TEST 3.1 TEST REQUESTED 1. Measurements for PCS 850 and PCS 1900 device according to FCC parts 22 and 24 2. Continuous conducted emission, power leads: Standard: FCC Rules and Regulations 47 CFR Part 15 Limit: Class B Method: FCC Rules and Regulations 47 CFR Part 15, Subpart B y C 3. Radiated emission, electromagnetic field: Standard: FCC Rules and Regulations 47 CFR Part 15 Limit: Class B Method: FCC Rules and Regulations 47 CFR Part 15, Subpart B Report No.: 22345RET Date: 2005-11-29 Page: 4 of 10 FDT08_04 3.2 REQUIREMENTS AND METHOD The test has been carried out according to the following documents and standards: 1. FCC part 22. 2. FCC part 24. 3. FCC Rules and Regulations 47 CFR Part 15, Subpart B: Limits and methods of measurements for radio frequency devices. Unintentional radiators. 4. FCC Rules and Regulations 47 CFR Part 15, Subpart C: Limits and methods of measurements for radio frequency devices. Intentional radiators. Radiated testing was performed in Cetecom's semi-anechoic chamber. This site has been fully described in a report submitted to the FCC and was accepted in a letter dated July 25, 2002. Radiated measurements were made in accordance with the general procedures of ANSI C63.4 and substitution method according to TIA/EIA 603. The testing procedures used are: 1. PEEM001: Medida de la tensión perturbadora en bornes de alimentación según EN 55022. 2. PEEM002: Medida del campo perturbador radiado según EN 55022. Uncertainty (factor k=2) was calculated according to the following CETECOM's internal documents: 1. PODT000: Procedimiento para el cálculo de incertidumbres de medida 2. FEM12_07: Formato de cálculo de incertidumbre a aplicar en l…
Text truncated - open the document above for the full version.
Eurofins Product Service Test Set-Up Photos page 1 Model No.: TPA GEN.2 FCC ID: P3O96902 Project No.: E7M21001-2817 Eurofins Product Service GmbH Storkower Str. 38C, D-15526 Reichenwalde, Germany Eurofins Product Service Test Set-Up Photos page 2 Model No.: TPA GEN.2 FCC ID: P3O96902 Project No.: E7M21001-2817 Eurofins Product Service GmbH Storkower Str. 38C, D-15526 Reichenwalde, Germany Eurofins Product Service Test Set-Up Photos page 3 Model No.: TPA GEN.2 FCC ID: P3O96902 Project No.: E7M21001-2817 Eurofins Product Service GmbH Storkower Str. 38C, D-15526 Reichenwalde, Germany Eurofins Product Service Test Set-Up Photos page 4 Model No.: TPA GEN.2 FCC ID: P3O96902 Project No.: E7M21001-2817 Eurofins Product Service GmbH Storkower Str. 38C, D-15526 Reichenwalde, Germany Eurofins Product Service Test Set-Up Photos page 5 Model No.: TPA GEN.2 FCC ID: P3O96902 Project No.: E7M21001-2817 Eurofins Product Service GmbH Storkower Str. 38C, D-15526 Reichenwalde, Germany Eurofins Product Service Test Set-Up Photos page 6 Model No.: TPA GEN.2 FCC ID: P3O96902 Project No.: E7M21001-2817 Eurofins Product Service GmbH Storkower Str. 38C, D-15526 Reichenwalde, Germany Eurofins Product Service Test Set-Up Photos page 7 Model No.: TPA GEN.2 FCC ID: P3O96902 Project No.: E7M21001-2817 Eurofins Product Service GmbH Storkower Str. 38C, D-15526 Reichenwalde, Germany Eurofins Product Service Test Set-Up Photos page 8 Model No.: TPA GEN.2 FCC ID: P3O96902 Project No.: E7M21001-2817 Eurofins Product Service GmbH Storkower Str. 38C, D-15526 Reichenwalde, Germany
VIA MAJAKOVSKIJ 10 b/c/d/e · REGGIO EMILIA · Italy
| # | Rule Parts | Frequency Range | Power Output | Emission | Tolerance |
|---|---|---|---|---|---|
| 2 | 24E | 1.85 GHz - 1.91 GHz | 579.00 mW | 300KGXW | 0.009 ppm |

OBD device (On Board Diagnostic device) with Bluetooth 4.0 low energy
Equipment Class
DTS - Digital Transmission System
OBD device (On Board Diagnostic device) with Bluetooth 4.0 Low Energy
Equipment Class
DTS - Digital Transmission System
Microwave Sensor for intrusion and movement detection
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
TXBMWMR
Equipment Class
DSC - Part 15 Security/Remote Control Transmitter
Telematic Tracking System
Equipment Class
PCB - PCS Licensed Transmitter