Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Copyright 2005 Arcwave, Inc. ARCXtend Wireless Plant Extension Solution 5.8 GHz Operation User Manual R1.0 Issue 1 P/N: Preliminary Arcwave, Inc. 910 Campisi Way, Suite 1C, Campbell, CA 95008 USA, Phone: 408-558-2300 www.arcwaveinc.com ARCXTEND 5.8 GHZ USER MANUAL – R1.0, ISSUE 1 Copyright 2005 Arcwave, Inc. ii REVISION HISTORY ISSUE # AUTHOR CHECK OUT CHECK IN COMMENTS 1.0 CM 08/29/2005 ARCXTEND 5.8 GHZ USER MANUAL – R1.0, ISSUE 1 Copyright 2005 Arcwave, Inc. iii NOTICES The information in this publication is subject to change without notice. Arcwave shall not be liable for technical or editorial errors or omissions nor for any damages resulting from the use of this material. Each configuration tested or described may or may not be the only available solution. This test is not a determination of product quality or correctness, nor does it ensure compliance with any federal, state or local requirements. Arcwave does not warrant products other than its own strictly as stated in Arcwave’s product warranties. U.S. Federal Communication Commission (FCC) Notification This device complies with part 15 of the U. S. FCC Rules and Regulations and with is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the U.S. FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with these instructions, may cause harmful interference to radio communications. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to correct the interference by one or more of the following measures: Increase the separation between the affected equipment and the unit; Connect the affected equipment to a power outlet on a different circuit from that which the receiver is connected to; Consult the dealer and/or experienced radio/TV technician for help. Part 15, Section 15.21 Warning Changes or modifications not expressly approved by Arcwave, Inc. could void the user's authority to operate the equipment. FCC IDs Numbers are listed below: FCC Identifier: TBD ARCXTEND 5.8 GHZ USER MANUAL – R1.0, ISSUE 1 Copyright 2005 Arcwave, Inc. iv RF Safety Warning: To insure compliance with FCC recommended General Population/Uncontrolled exposure limits the ARCXtend Hub and CPE must be installed a minimum of one foot from areas frequented by the general population. To insure compliance with FCC recommended Occupational/Controlled exposure limits, field engineers and technicians should maintain a minimum working distance of six inches, as measure from the front of the units to the front of their bodies, from the front of the Hub and CPE. For working distance inside six inches, RF exposure should be limited to an average of 30 minutes at a time. All Arcwave equipment, however, has been designed to allow installation and maintenance at a range well within FCC RF exposure levels. For further information, please refer to: http://www.fcc.gov/Bureaus/Engineering_Technology/Documents/bulletins/oet56/oet56e4.pdf. Arcwave and the Stylized Arcwave Logo, ARCXtend, ARCSmart, and PureBurst are trademarks of Arcwave, Inc. All other product or service names are the property of their respective owners. © Arcwave, Inc. 2005. Arcwave, Inc. 910 Campisi Way, Campbell, Ca, 95008 http://www.arcwaveinc.com ARCXTEND 5.8 GHZ USER MANUAL – R1.0, ISSUE 1 Copyright 2005 Arcwave, Inc. v TABLE OF CONTENTS INTRODUCTION 1 About this Document 1 Purpose 1 Audience 1 Prerequisites 1 Feedback 1 PRODUCT DESCRIPTION 2 Overview 2 System Configuration 2 Cable and Wireless Network Interfaces 3 Frequency Mapping 3 Signal Levels 3 Element Management 4 Applications 4 ARCXtend Wireless Drop 5 Wireless Overlay and Upstream 5 Equipment Description 6 ARCXtend Network Hub 6 Hub Interfaces 6 Hub Configurations 7 Hub Mounting Kits 8 ARCXtend CPE 9 CPE Configuration and Accessories 9 Downstream Signal Attenuators 10 ARCSmart TM 2.1 Intelligent Network Management 10 DOCSIS 2.0 Compliant ECM 10 Watchdog Timer 10 SNMP-compliant Arcwave Enterprise MIB 11 HTTP-based user interface 12 ARCSmart firmware upgrade 12 Advanced Network Management Features 12 Plug-n-Play 12 Downstream frequency agility 12 Settable Hub Transmit Power 12 PureBurst Ingress Noise Suppression 13 PRE-DEPLOYMENT PLANNING 14 Hub Site Selection 14 Line of Site 14 Range 14 Equipment Location 15 Checking for Upstream Interference 15 CPE Site Selection 16 Height and Location 16 Checking for Interference 17 Channel Plan 17 Downstream Configuration 17 Downstream Block Diagram 17 Upstream Configuration 18 Upstream Block Diagram 18 ARCXtend Multiple Hub Configurations 19 IP Network Preparation 19 Hub’s Default IP Address 19 ARCXTEND 5.8 GHZ USER MANUAL – R1.0, ISSUE 1 Copyright 2005 Arcwave, Inc. vi Cable Network IP Address 19 ECM Configuration File 20 TCP/IP Port Filtering 20 Hub Electrical Interface 20 AC Powering and Surge Protection 20 DC Powering 21 RF Signal Power Level and Quality 21 CPE Electrical Interface 21 AC Powering and Surge Protection 21 Lightning Protection 21 INSTALLATION AND COMMISSIONING 22 Prerequisites 22 Link Budget 22 Personnel 22 Equipment and Materials 22 Equipment Ordering and Staging 23 Hub installation & commissioning 24 Setup the Hub Power and RF Connection 24 Secure the Hub to the Strand 24 Establish a Local Connection to the Hub 25 Verify the Embedded Cable Modem has achieved operational maintenance state. 25 Set up and verify the Hub’s cable plant interface 25 Set up and verify the Hub’s wireless interface 26 Set the Hub Management Mod…
Text truncated - open the document above for the full version.
Chris Harvey From: Claire Hoque [[email protected]] Sent: Monday, August 29, 2005 6:55 PM To: Chris Harvey Cc: Chuck Cowden; Jack He Subject: answer: Arcwave, Inc. , FCC ID: PLRAX145500, Assessment NO.: AN05T5009, Notice#1 Page 1 of 1answer: Arcwave, Inc. , FCC ID: PLRAX145500, Assessment NO.: AN05T5009, Notice#1 8/30/2005 Hi Chris, Pls see our answer below. 1. The Test Report and the Theory of Operation exhibit have antenna descriptions of 20 degree 19dBi and 60 degree 15dBi. This differs from the manual specifications which have listed: AX1255-SM-90, 90 degree beam (10dBi), AX1255-SM-25, 20 degree beam (20dBi) and AX1255-VM-90, 90 degree beam (13dBi gain). Please correct this discrepancy and confirm if all 3 antennas mentioned in the Users Manual are to be approved in this application. <answer>user manual is revised to show the correct antenna gain(20 degree 19dBi and 60 degree 15dBi). 2. The maximum output power section of the report indicates operation of 5813-5845 MHz, however the remainder of the report indicates operation of 5813-5843 MHz. The Theory of Operation states that this device is capable of operation from 5813-5867 MHz. Please correct these discrepancies. <answer>test report and theory of op. are revised to show the correct operation of 5813-5843 MHz. Thanks, Claire <<AX1455 Theory of Operation(revised).pdf>> <<ARCXtend 5.8 GHz Users Manual(revised).pdf>> <<05U3489-1B FCC DTS Report(revised).pdf>>
PROPOSED FCC ID LABEL AND LOCATION ARCWAVE, INC This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID: PLRAX145500 FCC ID LABEL
FCC CFR47 PART 15 SUBPART C CERTIFICATION TEST REPORT FOR ArcXtend TM MODEL NUMBER: AX1455 FCC ID: PLRAX145500 REPORT NUMBER: 05U3489-1B ISSUE DATE: JUNE 23, 2005 Prepared for ARCWAVE INCORPORATED 910 CAMPISI WAY, #1C CAMPBELL, CA 95008, USA Prepared by COMPLIANCE ENGINEERING SERVICES, INC. d.b.a. COMPLIANCE CERTIFICATION SERVICES 561F MONTEREY ROAD, MORGAN HILL, CA 95037, USA TEL: (408) 463-0885 FAX: (408) 463-0888 REPORT NO: 05U3489-1B DATE: AUGUST 22, 2005 EUT: ArcXtend TM FCC ID: PLRAX145500 Page 2 of 68 COMPLIANCE CERTIFICATION SERVICES DOCUMENT NO: CCSUP4031A 561F MONTEREY ROAD, MORGAN HILL, CA 95037 USA TEL: (408) 463-0885 FAX: (408) 463-0888 This report shall not be reproduced except in full, without the written approval of CCS. Revision History Rev. Issue Date Revisions Revised By A 6/23/05 Initial Issue YZ B 8/22/05 Corrected typo in section 5.2 MH REPORT NO: 05U3489-1B DATE: AUGUST 22, 2005 EUT: ArcXtend TM FCC ID: PLRAX145500 Page 3 of 68 COMPLIANCE CERTIFICATION SERVICES DOCUMENT NO: CCSUP4031A 561F MONTEREY ROAD, MORGAN HILL, CA 95037 USA TEL: (408) 463-0885 FAX: (408) 463-0888 This report shall not be reproduced except in full, without the written approval of CCS. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS............................................................................................. 4 2. TEST METHODOLOGY .................................................................................................................. 5 3. FACILITIES AND ACCREDITATION .......................................................................................... 5 4. CALIBRATION AND UNCERTAINTY.......................................................................................... 5 4.1. MEASURING INSTRUMENT CALIBRATION ............................................................................. 5 4.2. MEASUREMENT UNCERTAINTY ............................................................................................... 5 5. EQUIPMENT UNDER TEST............................................................................................................6 5.1. DESCRIPTION OF EUT ..............................................................................................................6 5.2. MAXIMUM OUTPUT POWER .................................................................................................... 6 5.3. DESCRIPTION OF AVAILABLE ANTENNAS ............................................................................. 7 5.4. SOFTWARE AND FIRMWARE .................................................................................................... 7 5.5. WORST-CASE CONFIGURATION AND MODE......................................................................... 7 5.6. DESCRIPTION OF TEST SETUP ................................................................................................ 8 6. TEST AND MEASUREMENT EQUIPMENT .............................................................................. 10 7. CHANNEL TESTS ........................................................................................................................... 11 7.1.1. 6 dB BANDWIDTH ........................................................................................................... 11 7.1.2. 99% BANDWIDTH............................................................................................................ 15 7.1.3. PEAK OUTPUT POWER .................................................................................................. 19 7.1.4. MAXIMUM PERMISSIBLE EXPOSURE ........................................................................ 27 7.1.5. AVERAGE POWER........................................................................................................... 30 7.1.6. PEAK POWER SPECTRAL DENSITY ............................................................................ 31 7.1.7. CONDUCTED SPURIOUS EMISSIONS.......................................................................... 38 7.2. RADIATED EMISSIONS.............................................................................................................51 7.2.1. TRANSMITTER RADIATED SPURIOUS EMISSIONS ................................................. 51 7.2.2. TRANSMITTER ABOVE 1 GHz WITH 19dBi ANTENNA ............................................ 54 7.2.3. TRANSMITTER ABOVE 1 GHz WITH 15dBi ANTENNA ............................................ 55 7.2.4. WORST-CASE RADIATED EMISSIONS BELOW 1 GHz WITH 19dBi ANTENNA... 56 7.2.5. WORST-CASE RADIATED EMISSIONS BELOW 1 GHz WITH 15dBi ANTENNA... 60 8. SETUP PHOTOS .............................................................................................................................. 64 REPORT NO: 05U3489-1B DATE: AUGUST 22, 2005 EUT: ArcXtend TM FCC ID: PLRAX145500 Page 4 of 68 COMPLIANCE CERTIFICATION SERVICES DOCUMENT NO: CCSUP4031A 561F MONTEREY ROAD, MORGAN HILL, CA 95037 USA TEL: (408) 463-0885 FAX: (408) 463-0888 This report shall not be reproduced except in full, without the written approval of CCS. 1. ATTESTATION OF TEST RESULTS COMPANY NAME: ARCWAVE, INC. 910 CAMPISI WAY, #1C CAMPBELL, CA 95008 U.S.A EUT DESCRIPTION: ArcXtend TM MODEL: AX1455 (TESTED AX1455-SM-25 AND AX1455-SM-60) SERIAL NUMBER: 00001 DATE TESTED: JUNE 13 –JUNE 14, 2005 APPLICABLE STANDARDS STANDARD TEST RESULTS FCC PART 15 SUBPART C NO NON-COMPLIANCE NOTED Compliance Certification Services, Inc. tested the above equipment in accordance with the requirements set forth in the above standards. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Note: The results documented in this report apply only to the tested sample, under the conditions and modes of operation as described herein. This document may not be altered or revised in any way unless done so by Compliance Certification Services and all revisions are duly noted in the revisions section. Any alteration of this document not carried o…
Text truncated - open the document above for the full version.
REPORT NO: 05U3489 DATE: JUNE 23, 2005 EUT: ArcXtend TM FCC ID: PLRAX145500 Page 64 of 68 COMPLIANCE CERTIFICATION SERVICES DOCUMENT NO: CCSUP4031A 561F MONTEREY ROAD, MORGAN HILL, CA 95037 USA TEL: (408) 463-0885 FAX: (408) 463-0888 This report shall not be reproduced except in full, without the written approval of CCS. 8. SETUP PHOTOS ANTENNA PORT CONDUCTED RF MEASUREMENT SETUP ANTENNA PORT CONDUCTED PHOTO REPORT NO: 05U3489 DATE: JUNE 23, 2005 EUT: ArcXtend TM FCC ID: PLRAX145500 Page 65 of 68 COMPLIANCE CERTIFICATION SERVICES DOCUMENT NO: CCSUP4031A 561F MONTEREY ROAD, MORGAN HILL, CA 95037 USA TEL: (408) 463-0885 FAX: (408) 463-0888 This report shall not be reproduced except in full, without the written approval of CCS. RADIATED EMISSION SETUP WITH 19 dBi ANTENNA RADIATED FRONT PHOTO REPORT NO: 05U3489 DATE: JUNE 23, 2005 EUT: ArcXtend TM FCC ID: PLRAX145500 Page 66 of 68 COMPLIANCE CERTIFICATION SERVICES DOCUMENT NO: CCSUP4031A 561F MONTEREY ROAD, MORGAN HILL, CA 95037 USA TEL: (408) 463-0885 FAX: (408) 463-0888 This report shall not be reproduced except in full, without the written approval of CCS. RADIATED BACK PHOTO REPORT NO: 05U3489 DATE: JUNE 23, 2005 EUT: ArcXtend TM FCC ID: PLRAX145500 Page 67 of 68 COMPLIANCE CERTIFICATION SERVICES DOCUMENT NO: CCSUP4031A 561F MONTEREY ROAD, MORGAN HILL, CA 95037 USA TEL: (408) 463-0885 FAX: (408) 463-0888 This report shall not be reproduced except in full, without the written approval of CCS. RADIATED EMISSION SETUP WITH 15 dBi ANTENNA RADIATED FRONT PHOTO REPORT NO: 05U3489 DATE: JUNE 23, 2005 EUT: ArcXtend TM FCC ID: PLRAX145500 Page 68 of 68 COMPLIANCE CERTIFICATION SERVICES DOCUMENT NO: CCSUP4031A 561F MONTEREY ROAD, MORGAN HILL, CA 95037 USA TEL: (408) 463-0885 FAX: (408) 463-0888 This report shall not be reproduced except in full, without the written approval of CCS. END OF REPORT RADIATED BACK PHOTO
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 5.81 GHz - 5.84 GHz | 120.23 mW |

Point-to-Point Wireless Internet System
Equipment Class
DTS - Digital Transmission System
Point to Multipoint Wireless Internet System
Equipment Class
DTS - Digital Transmission System
Downstream Transmitter - Omnidirectional
Equipment Class
DTS - Digital Transmission System
Point To Multipoint Wireless System
Equipment Class
DTS - Digital Transmission System
Point To Multipoint Wireless System
Equipment Class
NII - Unlicensed National Information Infrastructure TX