Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
95 Series RFID System User’s Guide Lyngsoe 95 Series RFID System User’s Guide Part Number: 950119 Fourth Edition April 2002 The information in this manual is for reference purposes only and is subject to change without notice. The contents of this manual and the associated Lyngsoe 95 Series hardware are the property of Lyngsoe Industries and are copyrighted©. All rights are reserved by Lyngsoe Industries. In no event is Lyngsoe Industries liable for incidental or consequential damages in connection with or arising from the use of this manual or any related documentation. This document may not, in whole or in part, be copied, photocopied, reproduced, translated, or reduced to an electronic medium or machine readable form without prior written consent from Lyngsoe Industries. © 1997 - 2002 Lyngsoe Industries. All Rights Reserved. Lyngsoe is a registered trademark® of Lyngsoe Industries. All other product names and services listed are copyright and registered trademarks/trade names of their respective owners. Use, duplication or disclosure by the Government is subject to restrictions as set forth in subdivision (b)(3)(ii) of the Rights in Technical Data and Computer Software clause at 252.227-7013. Lyngsoe Industries. Printed in Canada. Lyngsoe Industries 5570 Kennedy Road, Unit B Mississauga, Ontario L4Z 2A9 CANADA Tel: +1 (905) 501-1533 Fax: +1 (905) 501-1538 FCC CLASS A Digital Device or Peripheral - Information to the User NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio energy and, if not installed and used in accordance with this guide, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case, the user will be required to correct the interference at his own expense. WARNING: Changes or modifications not expressly approved by Lyngsoe Industries could void the user’s authority to operate the equipment. This page intentionally left blank. Table of Contents Table of Contents 1 Table of Contents Preface What This Manual Contains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i Related Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii Text Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii Chapter 1: Introduction Transponder Identification System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 RFID Specific Terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Transponder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 Excitation Signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Response Signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Reading Points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Communication Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 RFID System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Postal RFID System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 95 Series RFID System Configuration Principles . . . . . . . . . . . . . . . . . . 1-3 Communication Links . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 System Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 System Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4 Reader Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Real Time Clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Receiving UHF Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Reader Data Handling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Reader Serial Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 Reader Reset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4 Exciter Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Chapter 2: Reader R95 Installation and Connections Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 Mechanical Assembling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 Connecting the RS-232 Communication Line. . . . . . . . . . . . . . . . . . . . . . 2-2 Connecting the RS-485 Two-Wire Communication Line . . . . . . . . . . . . .2-3 Connecting the RS-485 Four-Wire Communication Line. . . . . . . . . . . . .2-4 Connecting the Exciter Communication Line. . . . . . . . . . . . . . . . . . . . . . 2-6 Connecting the Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Connecting External Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 Chapter 3: Exciter E95 Installation and Connections Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1 Mechanical Assembling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2 Assembling …
Text truncated - open the document above for the full version.
Annex 3 - External Photographs of EUTPhoto # 1 PT21 Postal Tag, Model PT21FCC ID: PQGPT21 Annex 3 - External Photographs of EUTPhoto # 2 PT21 Postal Tag, Model PT21FCC ID: PQGPT21
Annex 4 - Internal Photographs of EUTPhoto # 1 PT21 Postal Tag, Model PT21FCC ID: PQGPT21 Annex 4 - Internal Photographs of EUTPhoto # 2 PT21 Postal Tag, Model PT21FCC ID: PQGPT21
April 12, 2002 TIMCO ENGINEERING INC. P O BOX 370 849 N.W. STATE ROAD 45 NEWBERRY, FLORIDA USA 32669 Subject:FCC Certification Authorization Application under FCC PART 15, Subpart C, Sec. 15.231(a) - Momentarily Operation at 433.92 MHz. Product:PT21 Postal Tag Model No.:PT21 FCC ID:PQGPT21 Dear Sir/Madam As appointed agent for Lyngsoe Industries Ltd., we would like to submit the application to the Federal Communications Commission for certification of the above product. Please review all necessary files uploaded to FCC OET site for detailed information. If you have any queries, please do not hesitate to contact us. Yours truly, Tri Minh Luu, P. Eng., V.P., Engineering Encl UltraTech Group of Labs 31040/SIT A96/TH/0093 46390-2049 200093-0 2 00-034 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 Telephone (905) 829-1570 Facsimile (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected] April 12, 2002 Lyngsoe Industries Ltd. 5570 Kennedy Road, Unit B Mississauga, Ontario Canada, L4Z 2A9 Attn.:Don Ferguson Subject:FCC Certification Application Testing under FCC PART 15, Subpart C, Sec. 15.231(a) - Momentarily Operation at 433.92 MHz. Product:PT21 Postal Tag Model No.:PT21 FCC ID:PQGPT21 Dear Mr. Ferguson, The product sample, as provided by you, has been tested and found to comply with FCC PART 15, Subpart C, Sec. 15.231(a) - Momentarily Operation at 433.92 MHz. Enclosed you will find copies of the engineering report. If you have any queries, please do not hesitate to contact us. Yours truly, Tri Minh Luu, P. Eng., V.P., Engineering Encl UltraTech Group of Labs 31040/SIT A96/TH/0093 46390-2049 200093-0 2 00-034 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4 Telephone (905) 829-1570 Facsimile (905) 829-8050 Website: www.ultratech-labs.com Email: [email protected] PT21 Postal Tag Model No.: PT21 FCC ID: PQGPT21 Applicant: Lyngsoe Industries Ltd. 5570 Kennedy Road, Unit B Mississauga, Ontario Canada, L4Z 2A9 In Accordance With FEDERAL COMMUNICATIONS COMMISSION (FCC) PART 15, SUBPART C Sec. 15.231(a) - Momentarily Operation at 433.92 MHz UltraTech's File No.: LYT-003FTX This Test report is Issued under the Authority of Tri M. Luu, Professional Engineer, Vice President of Engineering UltraTech Group of Labs Date: April 12, 2002 Report Prepared by: Tri M. Luu, P.Eng.Tested by: Hung Trinh, RFI Technician Issued Date: April 12, 2002Test Dates: Mar. 22-25, 2002 ß The results in this Test Report apply only to the sample(s) tested, and the sample tested is randomly selected. ß This report must not be used by the client to claim product endorsement by NVLAP or any agency of the US Government. UltraTech 3000 Bristol Circle, Oakville, Ontario, Canada, L6H 6G4 Telephone (905) 829-1570 Facsimile (905) 829-8050 Website: www.ultrat4ech-labs.com Email: [email protected] FCC PART 15, SUB. C, Sec. 15.231(a) - 433.92 MHz Momentarily Operated TransmitterPage 2 PT21 Postal Tag, Model PT21FCC ID: PQGPT21 ULTRATECH GROUP OF LABSFile #: LYT-003FTX 3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4April 12, 2002 Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: [email protected], Website: http://www.ultratech-labs.com ß Accreditation: FCC & NVLAP (USA), ACA (Australia), VCCI (Japan), ITI (UK), ACC-LAB (Canada, Europe/APEC/Canada MRA) ß All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST) TABLE OF CONTENTS EXHIBIT 1.SUBMITTAL CHECK LIST....................................................................................................................................4 EXHIBIT 1.INTRODUCTION.....................................................................................................................................................5 1.1.SCOPE.......................................................................................................................................................................................5 1.2.RELATED SUBMITAL(S)/GRANT(S)........................................................................................................................................5 1.3.NORMATIVE REFERENCES.................................................................................................................................................5 EXHIBIT 2.PERFORMANCE ASSESSMENT.........................................................................................................................6 2.1.CLIENT INFORMATION........................................................................................................................................................6 2.2.EQUIPMENT UNDER TEST (EUT) INFORMATION...........................................................................................................6 2.3.EUT’S TECHNICAL SPECIFICATIONS..............................................................................................................................7 2.4.LIST OF EUT’S PORTS..............................................................................................................................................................7 2.5.ANCILLARY EQUIPMENT.......................................................................................................................................................7 2.6.GENERAL TEST SETUP.........................................................................................................................................................7 EXHIBIT 3.EUT OPERATING CONDITIONS AND CONFIGURATIONS DURING TESTS.........................................8 3.1.CLIMATE TEST CONDITIONS.................................................................................................................................................8 3.2.OPERATIONAL TEST CONDITIONS & ARRANGEMENT FOR TESTS.................................................................................8 EXHIBIT 4.SUMMARY OF TEST RESULTS............................…
Text truncated - open the document above for the full version.
ANNEX 1 - PLOTS OF MEASUREMENTSPLOT # 1 PT21 Postal Tag, Model PT21FCC ID: PQGPT21 Remark: The typical duty was measured to be 9.2%. The maximum duty cycle of 27.28% was used for E-field measurements as worst case. ANNEX 1 - PLOTS OF MEASUREMENTSPLOT # 2 PT21 Postal Tag, Model PT21FCC ID: PQGPT21 20 dB BANDWIDTH MEASUREMENTS
Annex 2 - Photographs of Test SetupPhoto # 1 PT21 Postal Tag, Model PT21FCC ID: PQGPT21 Remark: The radiated emissions tests were repeated with EUT was placed in 3 different orthogonal positions Annex 2 - Photographs of Test SetupPhoto # 2 PT21 Postal Tag, Model PT21FCC ID: PQGPT21 Remark: The radiated emissions tests were repeated with EUT was placed in 3 different orthogonal positions Annex 2 - Photographs of Test SetupPhoto # 3 PT21 Postal Tag, Model PT21FCC ID: PQGPT21 Remark: The radiated emissions tests were repeated with EUT was placed in 3 different orthogonal positions
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15.231 | 433.42 MHz - 434.42 MHz | - |

PT40 Postal Tag
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
PT40A Postal tag
Equipment Class
DSR - Part 15 Remote Control/Security Device Transceiver
RFID READER
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
RFID READER
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
RFID PORTAL FOR POSTAL/DELIVERY TRACKING
Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz