Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Apr 14, 2008
Application Purpose
Original Equipment
Date of Application
Apr 14, 2008
Equipment Note
Synchronous Network Analog Clocks
Frequency Range
2412.00000000 - 2462.00000000
Company
Primex Wireless, Inc.
Country
United States

Documents & Files

Select a file to view

Users Manual

β†—

Cover Letter(s)

β†—
β†—

External Photos

β†—

ID Label/Location Info

β†—

Internal Photos

β†—

Test Report

β†—

Test Setup Photos

β†—

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

SNS Analog Clocks User Manual Page ii SNS Analog Clocks User Manual Notices Notices Β© Copyright 2008, Primex Wireless; all rights reserved. Trademarks Contact Primex Wireless Web: http://www.primexwireless.com/ Email: [email protected] United States Canada United Kingdom Telephone (800) 537-0464 (800) 330-1459 0800-3896996 Hours 7:00am - 5:00pm Central 7:00am - 5:00pm Central 8:30am – 5:00pm GMT Fax (262) 248-0061 (905) 952-0134 01422-349462 Mailing address Primex Wireless 965 Wells Street Lake Geneva, Wisconsin 53147 Primex Wireless 1310 Kerrisdale Blvd. Unit #4 Newmarket, ON L3Y 8V6 Primex Wireless Limited Dean Clough Halifax West Yorkshire HX3 5AX SNS Analog Clocks User Manual Page iii Contents Contents Introduction .............................................................................................................................................1 Precautions and regulatory compliance statements....................................................................................2 Equipment precautions..............................................................................................................................................2 Safety precautions......................................................................................................................................................2 FCC compliance.........................................................................................................................................................2 FCC radio frequency interference............................................................................................................................2 FCC radiation exposure limits...................................................................................................................................2 Power specifications for AC-powered devices.......................................................................................................2 SNS analog clocks..................................................................................................................................3 Configure an SNS analog clock................................................................................................................................5 Install an SNS analog clock....................................................................................................................................12 Install batteries in an SNS analog clock................................................................................................................15 Remove an Clock Lock-mounted SNS analog clock...........................................................................................16 Configuration tool procedures ............................................................................................................17 Set the password for a clock...................................................................................................................................18 Disconnect an SNS analog clock...........................................................................................................................19 Upgrade the firmware for an SNS analog clock...................................................................................................20 Configuration Templates..........................................................................................................................................21 Ping a clock...............................................................................................................................................................22 Display network information....................................................................................................................................23 Communication log procedures..............................................................................................................................24 Time zone information..............................................................................................................................................25 Set preferences.........................................................................................................................................................26 Troubleshoot..............................................................................................................................................................28 Appendix – Install/remove Configuration tool software ...................................................................29 Minimum system requirements.....................................................................................................................30 Install Configuration Tool software...............................................................................................................31 Uninstall Configuration Tool software..........................................................................................................33 Index ......................................................................................................................................................34 Introduction Primex Wireless’s SNS analog clocks are equipped with both an 802.11 b/g and Ethernet port interface. The clocks are able to connect in an existing wireless LAN (WLAN), supporting a wide variety of security protocols. Once the SNS clocks are configured using the Primex Wireless Configuration Tool, settings can be altered using Primex’s Applications Management Platform (AMP). SNS analog clocks will connect to the WLAN or Ethernet only at the times configured with AMP or the Configuration Tool. Any changes in configuration of an SNS analog clock via AMP are transmitted to the SNS analog clock the next time it connects to the WLAN or Ethernet. For detailed instructions on the use of AMP, please see the Primex AMP User Manual. SNS an…

Text truncated - open the document above for the full version.

Test Report

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 7 CERTIFICATION TEST REPORT FOR SYNCHRONOUS NETWORK ANALOG CLOCK (BATTERY &AC POWERED) MODEL NUMBER*: SNS4Z155, SNS4Z157, SNS4Z159, SNS7A306, SNS4Z164, SNS7A330, SNS4Z163, SNS4Z176, SNS4Z177, SNS4Z512, SNS4Z180, SNS4Z227 FCC ID: PZ3-SNSA IC: 4256A-SNSA REPORT NUMBER: 07U11496-1 ISSUE DATE: APRIL 2, 2008 Prepared for PRIMEX WIRELESS, INC. 965 WELLS STREET LAKE GENEVA, WI 53147, U.S.A. Prepared by COMPLIANCE CERTIFICATION SERVICES 47173 BENICIA STREET FREMONT, CA 94538, U.S.A. TEL: (510) 771-1000 FAX: (510) 661-0888 *Details of specific model(s) and model tested are listed in the body of this report REPORT NO: 07U11496-1 DATE: APRIL 2, 2008 FCC ID: PZ3-SNSA IC: 4256A-SNSA Page 2 of 106 COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of CCS. Revision History Rev. Issue Date Revisions Revised By -- 04/2/08 Initial Issue F. Ibrahim REPORT NO: 07U11496-1 DATE: APRIL 2, 2008 FCC ID: PZ3-SNSA IC: 4256A-SNSA Page 3 of 106 COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of CCS. TABLE OF CONTENTS 1. ATTESTATION OF TEST RESULTS.................................................................................... 5 2. TEST METHODOLOGY ........................................................................................................ 6 3. FACILITIES AND ACCREDITATION.................................................................................... 6 4. CALIBRATION AND UNCERTAINTY .................................................................................. 6 4.1. MEASURING INSTRUMENT CALIBRATION ............................................................... 6 4.2. MEASUREMENT UNCERTAINTY................................................................................ 6 5. EQUIPMENT UNDER TEST ................................................................................................. 7 5.1. DESCRIPTION OF EUT................................................................................................ 7 5.2. MODIFICATION (S) ...................................................................................................... 8 5.3. DESCRIPTION OF MODEL DIFFERENCES.............................................................. 10 5.4. MAXIMUM OUTPUT POWER..................................................................................... 11 5.5. DESCRIPTION OF AVAILABLE ANTENNAS............................................................. 11 5.6. SOFTWARE AND FIRMWARE................................................................................... 11 5.7. WORST-CASE CONFIGURATION AND MODE ........................................................ 11 5.8. DESCRIPTION OF TEST SETUP............................................................................... 12 6. TEST AND MEASUREMENT EQUIPMENT ....................................................................... 14 7. ANTENNA PORT TEST RESULTS .................................................................................... 15 7.1. 802.11b MODE IN THE 2.4 GHz BAND...................................................................... 15 7.1.1. 6 dB BANDWIDTH .............................................................................................. 15 7.1.2. 99% BANDWIDTH .............................................................................................. 19 7.1.3. OUTPUT POWER ............................................................................................... 23 7.1.4. AVERAGE POWER ............................................................................................ 27 7.1.5. POWER SPECTRAL DENSITY .......................................................................... 28 7.1.6. CONDUCTED SPURIOUS EMISSIONS............................................................. 32 7.2. 802.11g MODE IN THE 2.4 GHz BAND...................................................................... 39 7.2.1. 6 dB BANDWIDTH .............................................................................................. 39 7.2.2. 99% BANDWIDTH .............................................................................................. 43 7.2.3. OUTPUT POWER ............................................................................................... 47 7.2.4. AVERAGE POWER ............................................................................................ 51 7.2.5. POWER SPECTRAL DENSITY .......................................................................... 52 7.2.6. CONDUCTED SPURIOUS EMISSIONS............................................................. 56 REPORT NO: 07U11496-1 DATE: APRIL 2, 2008 FCC ID: PZ3-SNSA IC: 4256A-SNSA Page 4 of 106 COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of CCS. 8. RADIATED TEST RESULTS .............................................................................................. 63 8.1. LIMITS AND PROCEDURE ........................................................................................ 63 8.2. TRANSMITTER ABOVE 1 GHz .................................................................................. 64 8.2.1. TX ABOVE 1 GHz FOR 802.11b MODE IN THE 2.4 GHz BAND ....................... 64 8.2.2. TX ABOVE 1 GHz FOR 802.11g MODE IN THE 2.4 GHz BAND ....................... 73 8.3. RECEIVER ABOVE 1 GHz ......................................................................................... 82 8.3.1. RX ABOVE 1 GHz FOR 11B MODE ................................................................... 82 8.3…

Text truncated - open the document above for the full version.

Test Setup Photos

REPORT NO: 07U11496-1 DATE: APRIL 2, 2008 FCC ID: PZ3-SNSA IC: 4256A-SNSA Page 100 of 106 COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of CCS. 11. SETUP PHOTOS ANTENNA PORT CONDUCTED RF MEASUREMENT SETUP ANTENNA PORT CONDUCTED PHOTO REPORT NO: 07U11496-1 DATE: APRIL 2, 2008 FCC ID: PZ3-SNSA IC: 4256A-SNSA Page 101 of 106 COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of CCS. RADIATED RF MEASUREMENT SETUP RADIATED FRONT PHOTO – AC POWERED CLOCK REPORT NO: 07U11496-1 DATE: APRIL 2, 2008 FCC ID: PZ3-SNSA IC: 4256A-SNSA Page 102 of 106 COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of CCS. RADIATED BACK PHOTO – AC POWERED CLOCK REPORT NO: 07U11496-1 DATE: APRIL 2, 2008 FCC ID: PZ3-SNSA IC: 4256A-SNSA Page 103 of 106 COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of CCS. RADIATED FRONT PHOTO – BATTERY POWERED CLOCK REPORT NO: 07U11496-1 DATE: APRIL 2, 2008 FCC ID: PZ3-SNSA IC: 4256A-SNSA Page 104 of 106 COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of CCS. RADIATED BACK PHOTO – BATTERY POWERED CLOCK REPORT NO: 07U11496-1 DATE: APRIL 2, 2008 FCC ID: PZ3-SNSA IC: 4256A-SNSA Page 105 of 106 COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of CCS. POWERLINE CONDUCTED EMISSIONS MEASUREMENT SETUP LINE CONDUCTED FRONT PHOTO REPORT NO: 07U11496-1 DATE: APRIL 2, 2008 FCC ID: PZ3-SNSA IC: 4256A-SNSA Page 106 of 106 COMPLIANCE CERTIFICATION SERVICES FORM NO: CCSUP4031B 47173 BENICIA STREET, FREMONT, CA 94538, USA TEL: (510) 771-1000 FAX: (510) 661-0888 This report shall not be reproduced except in full, without the written approval of CCS. END OF REPORT LINE CONDUCTED BACK PHOTO

Contact Information

Applicant

Arthur John Mahanna(Product Manager)
[email protected]262-249-3280Fax: 262-248-0061

Test Firm

Compliance Certification ServicesThu Chan
[email protected]510-771-1122Fax: 510-661-0888

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz348.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Primex Wireless, Inc.

Synchronous Network System AC Temperature & Humidity Sensor - FCC ID PZ3-SNSH - Primex Wireless, Inc.
PZ3-SNSH

Synchronous Network System AC Temperature & Humidity Sensor

Nov 09, 2011

Equipment Class

DTS - Digital Transmission System
Emergency Lighting Controller - FCC ID PZ3-SNSE - Primex Wireless, Inc.
PZ3-SNSE

Emergency Lighting Controller

Mar 15, 2011

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Synchronous Network System Personal Series Clock - FCC ID PZ3-SNSP - Primex Wireless, Inc.
PZ3-SNSP

Synchronous Network System Personal Series Clock

Oct 19, 2010

Equipment Class

DTS - Digital Transmission System
SYNCHRONOUS NETWORK SYSTEM TEMPERATURE SENSOR - FCC ID PZ3-SNST - Primex Wireless, Inc.
PZ3-SNST

SYNCHRONOUS NETWORK SYSTEM TEMPERATURE SENSOR

May 03, 2010

Equipment Class

DTS - Digital Transmission System
Part 90.238 Telemetry Transmitter - FCC ID PZ3-FM72 - Primex Wireless, Inc.
PZ3-FM72

Part 90.238 Telemetry Transmitter

Dec 13, 2001

Equipment Class

TNB - Licensed Non-Broadcast Station Transmitter