FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Radwin Ltd./
  3. Q3KWL1000F49

Q3KWL1000F49Point to Point Radio System

Radwin Ltd.
Point to Point Radio System - FCC ID Q3KWL1000F49 - Radwin Ltd.
Click to zoom

Application Details

Equipment Class
TNB - Licensed Non-Broadcast Station Transmitter
Date of Grant
May 23, 2005
Application Purpose
Original Equipment
Date of Application
May 23, 2005
Equipment Note
Point to Point Radio System
Frequency Range
4950.00000000 - 4980.00000000
Company
Radwin Ltd.
Country
Israel

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Block Diagram

↗

Cover Letter(s)

↗
↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗
↗

Operational Description

↗

Parts List/Tune Up Info

↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

WinLink™1000 Installation and Operation Manual Point-to-Point Wireless Product Family Revision 3.0 WinLink 1000 Point-to-Point Wireless TDM/IP Revision 3.0 Installation and Operation Manual Notice This manual contains information that is proprietary to RADWin Ltd. ("RADWIN"). No part of this publication may be reproduced in any form whatsoever without prior written approval by RADWIN Ltd. Right, title and interest, all information, copyrights, patents, know-how, trade secrets and other intellectual property or other proprietary rights relating to this manual and to the WinLink 1000 and any software components contained therein are proprietary products of RADWIN protected under international copyright law and shall be and remain solely with RADWIN. WinLink 1000 is a registered trademark of RADWIN. No right, license, or interest to such trademark is granted hereunder, and you agree that no such right, license, or interest shall be asserted by you with respect to such trademark. You shall not copy, reverse compile or reverse assemble all or any portion of the Manual or the WinLink 1000. You are prohibited from, and shall not, directly or indirectly, develop, market, distribute, license, or sell any product that supports substantially similar functionality as the WinLink 1000, based on or derived in any way from the WinLink 1000. Your undertaking in this paragraph shall survive the termination of this Agreement. This Agreement is effective upon your opening of the WinLink 1000 package and shall continue until terminated. RADWIN may terminate this Agreement upon the breach by you of any term hereof. Upon such termination by RADWIN, you agree to return to RADWIN the WinLink 1000 and all copies and portions thereof. For further information contact RADWIN at the address below or contact your local distributor. International Headquarters RADWIN Ltd. 32 Habarzel Street Tel Aviv 69710 Israel Tel: 972-3-7662900 Fax: 972-3-7662902 E-mail: [email protected] U.S. Headquarters RADWIN Inc. 900 Corporate Drive Mahwah, NJ 07430 USA Tel: (201) 529-1100Fax: (201) 529- 5777 E-mail: [email protected] FCC-15 User Information This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. Changes or modifications to this equipment not expressly approved by the party responsible for compliance (RADWIN) could void the user’s authority to operate the equipment. It is the responsibility of the installer to ensure that when using the outdoor antenna kits in the United States (or where FCC rules apply), only those antennas certified with the product are used. The use of any antenna other than those certified with the product is expressly forbidden in accordance to FCC rules CFR47 part 15.204. Warning Installing WinLink 1000 Units 1 Quick Start Guide Installation of WinLink 1000 should be carried out only by a qualified technician. If you are familiar with WinLink 1000, use this guide to prepare the units for operation. 1. Installing WinLink 1000 Units ODU Package Contents: • ODU • Mast/Wall mounting kit • WinLink 1000 Management software installation CD • Mounting instructions • Spare RJ-45 connector • ODU to IDU cable at length ordered (optional) IDU-E Package Contents: • IDU-E • 110V/240V adaptor • IDU wall-mounting drilling template • Spare RJ-45 connector (Optional) IDU-C Package Contents: • IDU-C • For AC model, 110v/240 VAC with 3-prong connector cable • For DC model, -48 VDC with 3-pin terminal block connector (green) • IDU standard 1-U, 19” carrier rack • Spare RJ-45 connector Equipment Required: • RJ-45 crimp tool (If pre-assembled cable is not used) Quick Start Guide WinLink 1000 Installation and Operation Manual 2 Installing WinLink 1000 Units • Drill (for wall mounting only) • IDU and ODU grounding cable • 13 mm or 1/2′′ socket spanner • ODU to IDU cable if not ordered (Outdoor class, CAT-5e, 4 twisted pairs) • Cable ties • Laptop running Windows 2000 or Windows XP Before the installation 1. Install the WinLink 1000 software on the laptop. 2. Verify that all equipment and tools are available. Performing Installation Î To install the ODU: 1. At site A, route the ODU cable from the ODU location (on the roof) to the IDU location (inside the building). The maximum length is 100m. 2. Mount the ODU unit to the mast or wall, using the mounting kit. 3. Connect the RJ-45 connectors to both ends of the cable, use the pinout table and diagram below: IDU RJ-45 Wire Color Function ODU RJ-45 1 White/Green Ethernet (RxN) 1 Twisted 2 Green Ethernet (RxT) 2 3 White/Orange Ethernet (TxT) 3 Twisted 4 Blue Power (+) 4 5 White\Blue Power (+) 5 Twisted 6 Orange Ethernet (TxN) 6 7 White/Brown Power (−) 7 Twisted 8 Brown Power (−) 8 4. Secure the ODU and ground cables to the mast or brackets using cable ties. 5. Repeat the procedure at site B. WinLink 1000 Installation and Operation Manual Quick Start Guide Installing WinLink 1000 Units 3 Î To align the ODU: 1. Connect power to the IDU. Do not stand in front of a live outdoor unit. Th…

Text truncated - open the document above for the full version.

Attestation Statements

HERM O N LA BO RA TO RIES May 18, 2005 American TCB 6731 Whittier Ave Suite C110 McLean, VA 22101 Attn: Mr. Douglas E. Noble, Examining Engineer RE: your e-mail dated May 17, 2005; Radwin Ltd. FCC ID: Q3KWL1000F49, ATCB002347 Dear Mr. Noble, Please find below the answers to your questions. The spectrum analyzer readings are calibrated in terms of equivalent RMS voltage (dBuV) or power (dBm). The transmitter output power was measured in terms of equivalent RMS power with 100 kHz resolution bandwidth and 3 MHz video bandwidth and after that, the readings were integrated over channel bandwidth 20 MHz as provided in plots 7.1.1 to 7.1.21 of the test report. Obviously, the output power measured in terms of equivalent RMS power or in terms of equivalent RMS voltage may be obtained one from another using 107 dB conversion factor which represents 50 Ohm input impedance of the spectrum analyzer and conversion from mW to uV, but the limit of section 90.1215 is stated in dBm. The output power was provided in dBm to compare it with the standard limit. Sincerely, Michael Nikishin, EMC group leader Hermon Laboratories

Cover Letter(s)

RADWIN Ltd. 32 Habarzel St Tel-Aviv, 69710, Israel, Tel- 972-3-766-2901, Fax-972-3-766-2902 April 17, 2005 American TCB 6731 Whittier Ave Suite C110 McLean, VA 22101 USA Subject: Application for certification of a wireless point–to-point transmission system, FCC ID:Q3KWL1000F49 Dear Gentlemen, Please find attached our application for certification of a wireless point–to-point transmission system, model names WinLink 1000/F49, AirMux-200/F49, FibAir 4849, MRL-500, FCC ID:Q3K WL1000F49, prepared in accordance with FCC Rules, part 90, sections 90.210, 90.1215. The product testing and this application for certification were performed by Hermon Laboratories, which is listed by FCC, Registration Numbers 90623, 90624. Hermon Labs responsible person is Mr. Alex Usoskin, tel: 011 972 4628 8001, fax:011 972 4628 8277, e-mail:[email protected]. Please send an invoice to Hermon Labs. Sincerely yours, Dan Weitzman Professional services manager Radwin Ltd

Cover Letter(s)

RADWIN Ltd. 32 Habarzel St Tel-Aviv, 69710, Israel, Tel- 972-3-766-2901, Fax-972-3-766-2902 April 17, 2005 American TCB 6731 Whittier Ave Suite C110 McLean, VA 22101 USA Subject: Request for confidentiality for a wireless point–to-point transmission system, FCC ID:Q3KWL1000F49 Dear Gentlemen, We apply to you with request to withhold Radwin Ltd. trade secrets in Application for Certification for FCC ID:Q3KWL1000F49. These trade secrets can be found in the transmitter schematic diagram, file name “Schematics_16288” (2 pages of this Application). Many thanks in advance. Sincerely yours, Dan Weitzman Professional services manager Radwin Ltd

Cover Letter(s)

RADWIN Ltd. 32 Habarzel St Tel-Aviv, 69710, Israel, Tel- 972-3-766-2901, Fax-972-3-766-2902 Date: Feb 28 th 2005 Subject: Compliance of Model AirMux I would like to bring to your attention that the AirMux/WinLink system that was tested at Hermon Labs 02/2005 for FCC standards have four commercial models: AirMux-200/F49 WinLink 1000/F49 FibAir 4849 MRL-500 Therefore User Manual for WinLink 1000 is valid for AirMux-200, FibAir 4849, MRL-500. Please consider in reports and certifications. Sincerely Dan Weitzman Professional Services Manager

Cover Letter(s)

RADWIN Ltd. 32 Habarzel St Tel-Aviv, 69710, Israel, Tel- 972-3-766-2901, Fax-972-3-766-2902 Date: Mar. 22, 05 Subject: Final power amplifier DC Current consumption. I would like to bring to your attention that the AirMux/WinLink/FibAir/MRL system that was tested at Hermon Labs 02/2005 for FCC standards have final power amplifier with normal constant DC voltage/current consumption of: ICC= 100mA Vcc=3.3v Sincerely Dan Weitzman

Cover Letter(s)

FCC Declaration of Conformity (see notes) We, the undersigned, Company: RADWin Inc. Address: 900 corporate drive Country: Mahwah, N.J 07430 USA Tel. number: + 201 529 1100 Fax number: + 201 529 5777 are the Responsible Party for this Declaration, certify and declare under our sole responsibility that the following equipment: Brand Type Product description WinLink 1000/F49 AirMux 200/F49 FibAir 4849 MRL 500/F49 Point-to-point wireless transmission system complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Tel Aviv, Israel June 30 2004 (Company stamp) Sharon Sher, CEO and President note 1:This statement shall be supplied with the product at the time of marketing or importation. note 2: This statement shall be included in the user’s manual or as a separate sheet. note 3: The responsible party for a Declaration of Conformity must be located within the United States. note 4: The responsible party for a Declaration of Conformity can be either: manufacturer (if located within the United States), or the importer.

External Photos

Radwin Ltd. FCC ID: Q3KWL1000F49 Date: April 2005 Page 1 of 4 EXTERNAL PHOTOGRAPHS This document contains 3 photographs Radwin Ltd. FCC ID: Q3KWL1000F49 Date: April 2005 Page 2 of 4 Photograph No.1 Winlink 1000/F49 outdoor radio terminal Front view Radwin Ltd. FCC ID: Q3KWL1000F49 Date: April 2005 Page 3 of 4 Photograph No.2 Winlink 1000/F49 outdoor radio terminal Rear side view Radwin Ltd. FCC ID: Q3KWL1000F49 Date: April 2005 Page 4 of 4 Photograph No.3 Winlink 1000/F49 outdoor radio terminal Bottom view

ID Label/Location Info

FCC ID:Q3KWL1000F49 Date: April 2005 Page 1 of 3 Label with FCC ID:Q3KWL1000F49 FCC ID:Q3KWL1000F49 Date: April 2005 Page 2 of 3 An outdoor radio terminal shall bear the label with FCC ID: Q3KWL1000F49 and RADWIN logo on a back panel as shown in the drawing below: The statement according to FCC part 15 section 15.19 is affixed to indoor unit, connected by wires to outdoor unit and marketed together. WINLINK Manufacturer: Radwin Ltd. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC ID:Q3KWL1000F49 Date: April 2005 Page 3 of 3

Internal Photos

Radwin Ltd. FCC ID: Q3KWL1000F49 Date: April 2005 Page 1 of 8 INTERNAL PHOTOGRAPHS This document contains 7 photographs Radwin Ltd. FCC ID: Q3KWL1000F49 Date: April 2005 Page 2 of 8 Photograph No.1 Winlink 1000/F49 outdoor radio unit Internal view Radwin Ltd. FCC ID: Q3KWL1000F49 Date: April 2005 Page 3 of 8 Photograph No.2 Winlink 1000/F49 internal view without cover Radwin Ltd. FCC ID: Q3KWL1000F49 Date: April 2005 Page 4 of 8 Photograph No.3 Winlink 1000/F49 Main PCB front view

Internal Photos

Radwin Ltd. FCC ID: Q3KWL1000F49 Date: April 2005 Page 5 of 8 Photograph No.4 Winlink 1000/F49 main board Radwin Ltd. FCC ID: Q3KWL1000F49 Date: April 2005 Page 6 of 8 Photograph No.5 Winlink 1000/F49 Main PCB second side view Radwin Ltd. FCC ID: Q3KWL1000F49 Date: April 2005 Page 7 of 8 Photograph No.6 Winlink 1000/F49 RF board Radwin Ltd. FCC ID: Q3KWL1000F49 Date: April 2005 Page 8 of 8 Photograph No.7 Winlink 1000/F49 RF board second side

Operational Description

WinLink™ 1000 Family High Capacity Carrier Class Radio Systems WinLink™ 1000 family of products is a carrier-class, high capacity and extremely competitive Point to Point broadband wireless transmission solution. It packs Legacy TDM and Ethernet services over 2.4GHz and 4.9- 5.9GHz spectrum bands and is suitable for deployment in FCC and ETSI regulated countries. WinLink™ 1000 provides high capacity connectivity of up to 48 Mbps and allows for rapid deployment of E1/T1s and Ethernet links at a fraction of any alternatives' cost. WinLink™ 1000 efficiently addresses service providers and enterprises, requiring immediate deployment of affordable, carrier-class, long range and high capacity connectivity solutions. Available at multiple frequency bands and at various configurations, all WinLink™ 1000 products are highly robust, simple to install and extremely competitive. Highlights ƒ High data rate, up to 48Mbps ƒ Long Range, up to 80 Km ƒ Integrated solution for nxE1s/T1s and Fast Ethernet ƒ Carrier-Class in various spectrum bands: 5.725 – 5.850 GHz 5.470 – 5.725 GHz 5.250 – 5.350 GHz 4.940 – 4.990 GHz 2.400 – 2.4835 GHz ƒ Compliant with FCC, IC and ETSI regulations ƒ Complete SNMP based local and remote management, integrated with SNMPc and HPOV. Key Benefits ƒ Short time to service ƒ License exempt frequencies remove regulatory overhead and delays ƒ Wireless connectivity instead of private line leasing from service providers, reducing costs ƒ Compact integrated solution that is simple to install and operate Typical Applications Remote Sites Connectivity WinLink™ 1000 is offered to enterprises with multiple sites that require a cost effective and transparent connection of their LAN and PBX systems across their various campuses . Broadband Access WinLink™ 1000 provides a broadband access solution, offering broadband Ethernet and Leased Line services to Small and Medium Enterprises (SMEs). Backhauling WinLink™ 1000 backhauls traffic from cellular base-stations, Hotspots (WiFi) or points of presence (POPs) of wireless ISPs to the backbone network. Page 1 of 3 WinLink™ 1000 Family Product specifications Configuration Architecture Indoor Unit: IDU-E (Enterprise form-factor), IDU-C (Carrier form-factor) Outdoor Unit: ODU IDU to ODU Interface Outdoor CAT-5 cable; Maximum cable length: 100m Radio Frequency Bands 2.400 – 2.4835 GHz 4.940 – 4.990 GHz 5.250 – 5.350 GHz 5.470 – 5.725 GHz (includes DFS/TPC) 5.725 – 5.850 GHz Data Rate Configurable up to 48Mbps (bi-directional) Channel Bandwidth 20 MHz Duplex Technique TDD Modulation OFDM – BPSK/QPSK/16QAM/64QAM Transmit Power Configurable, 18dBm max, 12.8dBm max limited for 4.9GHz Received Dynamic Range >60dB Error Correction FEC k=1/2, 2/3, 3/4 Encryption AES 128 LAN Interface Type 10/100BaseT Interface with Auto-negotiation (IEEE 802.3) Number of Ethernet Ports 1, 2 Framing/Coding IEEE 802.3/U Bridging Self-learning up to 2047 MAC addresses IEEE 802.1Q Traffic Handling MAC layer bridging, self-learning Data Latency 3msec typical Line Impedance 100Ω VLAN Support Transparent Connector RJ-45 Page 2 of 3 E1/T1 Interface Framing Unframed (transparent) Number of E1/T1 Ports 1, 2, 4 Standard Compliance G.703, G.826 Timing Independent Tx and Rx timing Line Code E1: HDB3 @ 2.048 Mbps T1: B8ZS/AMI @ 1.544 Mbps Latency 8msec Impedance E1-120Ω, balanced T1-100Ω, balanced Connector RJ-45 Jitter & Wander According to G.823, G.824 Management Protocol SNMP based Network Management Supports SNMPc and HPOV Upgrade Capabilities Local and remote software upgrade Diagnostics Local and remote loopback testing Mechanics ODU Dimensions (includes 1ft flat integrated antenna) 30.5cm(H) x 30.5cm(W) x 5.8cm(D) Weight: 1.5kg/3.3lb ODU Dimensions (integrated antenna not included) 24.5cm(H) x 13.5cm(W) x 4.0cm(D) Weight: 1.0kg/2.2lb IDU-E Dimensions 16.5cm(H) x 23.6cm(W) x 4.5cm(D) Weight: 0.5kg/1.1lb IDU-C Dimensions 43cm(H) x 29cm(W) x 4.5cm(D) Weight: 1.5kg/3.3lb Power and Mounting Power Feeding 110/220VAC, 50/60Hz, -48VDC Power Consumption ODU with IDU-E, 10W Max ODU with IDU-C, 14W Max Mounting Pole and Wall Environmental Outdoor Unit Enclosure All weather cases ODU Operating Temperatures -35°C - 60°C / -31°F - 140°F IDU Operating Temperatures -5°C - 45°C / 23°F - 113°F Humidity Up to 90% non-condensing Page 3 of 3 Antennas 2.400-2.4835 GHz 4.940-4.990 GHz 5.250-5.350 GHz 5.470-5.725 GHz 5.725-5.850 GHz 1ft Integrated Antenna Gain 17dBi - external 22dBi 22dBi 22dBi Beam Width 20° 9° 9° 9° Polarization Linear N/A Linear Linear Linear 2ft External Antenna Gain 24dBi 27dBi 28dBi 28dBi 28dBi Beam Width 8° 4.5° 4.5° 4.5° 4.5° Polarization Linear Linear Linear Linear Linear * Higher gain antennas are available upon request Regulation 2.400-2.4835 GHz 4.940-4.990 GHz 5.250-5.350 GHz 5.470-5.725 GHz 5.725-5.850 GHz Radio FCC: 47CFR Part 15, Subpart C Part 90 Part 15, Subpart E Part 15, Subparts C&B IC RSS-210 RSS-210 RSS-210 ETSI EN 300 328 EN 300 216 V1.2.1 EN 300 440 V1.3.1 Dynamic Frequency Selection and Transmission Power Control (DFS/TPC) Supported Supported Supported Supported complies with EN 301 893 V1.2.2 Supported Safety TUV 60950, According to UL 60950 CAN-USA C22.2 No.60950 EMC FCC CFR Part15, Subpart B CAN-ETSI EN 301 489-1 Environmental ETSI IEC 60721-3-4 Class 4M5 IP67

Parts List/Tune Up Info

RADWIN Ltd. 32 Habarzel St Tel-Aviv, 69710, Israel, Tel- 972-3-766-2901, Fax-972-3-766-2902 Date: Mar. 22, 05 Subject: Final power amplifier DC Current consumption. I would like to bring to your attention that the AirMux/WinLink/FibAir/MRL system that was tested at Hermon Labs 02/2005 for FCC standards have final power amplifier with normal constant DC voltage/current consumption of: ICC= 100mA Vcc=3.3v This is the maximum consumption in order to obtain transmit power of 12.8dBm according to the final test results, and blocked by HW and SW and is not user configurable. Sincerely Dan Weitzman

Parts List/Tune Up Info

FCCID:Q3KWL1000F49 2/12/2004 HighLink - ODU CPU - AP0039180 ( rev 03 ) - BOM Quantity Description Reference V alue RADWIN 9 CAP.TAN SMD B 10uF 16V 10% C20 C97 C111 C112 C 10uF/16V EC0000420 90 CAP.CER SMD 0603 10nF 50V 10% ;X7R C8 C9 C11 C12 C13 C 1 10nF/50V EC0000430 2 "CAP.H.V,SMD,10nF,2KV,20%,0.2I,Z5V" C36 C203 10nF/2KV EC0000440 42 "CAP.CER SMD 0603 0.1uF 16V 5%,COG" C2 C3 C4 C5 C6 C10 C 0.1uF/16V EC0000450 1 CAP.CER SMD 0805 1uF 25V 10% ;X7R C144 1uF/25V EC0000470 5 "CAP.CER SMD 0603 1nF 50V 10%,X7R" C121 C170 C173 C17 6 1nF/50V EC0002620 2 CAP.CER SMD 0603 270pF 50V 5% ;COG C134 C135 270pF/50V EC0002800 1 CAP.CER SMD 2225 1uF 100V 10% ;X7R C204 1uF/100V EC0008500 1 CAP.CER SMD 0603 220pF 50V 5% ;COG C184 220pF/50V EC0010300 6 CAP.CER SMD 0805 0.1uF 50V 10% ;X7R C143 C146 C156 C16 2 0.1uF/50V EC0012690 2 CAP.CER SMD 1206 0.1uF 100V 5% ;X7R C153 C161 0.1uF/100V EC0016900 2 CAP.CER SMD 0805 47nF 100V 5% ;X7R C151 C157 47nF/100V EC0016970 6 CAP. TAN SMD D 330UF 10V LOW ESR C35 C37 C38 C116 C1 330UF/10V EC0020220 1 CAP. CER SMD 0805 330PF 50V 10% C139 330PF/50V EC0020250 1 CAP. CER SMD 0805 1000PF 50V 10% C136 1000PF/50V EC0020260 3 CAP. ELE T.H 8x11.5 22uF 100V C31 C32 C34 22uF/100V EC0020300 3 CAP. TAN SMD C 22uF 20V 10% C147 C149 C150 22uF/20V EC0020310 1 CAP. CER SMD 0805 22NF 50V 10% C154 22NF/50V EC0020320 1 CAP. CER SMD 0805 33NF 50V 10% C1 33NF/50V EC0020330 1 CAP. CER SMD 0805 220PF 50V 5% C137 220PF/50V EC0020340 1 CAP. CER SMD 0805 10nF 50V 10% C159 10nF/50V EC0020370 1 CAP. CER SMD 1812 470NF 100V C178 470NF/100V EC0020400 1 CAP. TAN SMD A 1.5UF 16V 10% C160 1.5UF/16V EC0020440 1 CAP. TAN SMD A 4.7UF 16V 10% C167 4.7UF/16V EC0020450 1 CAP. ELE SMD 18x15 150UF 100V ? C114 150UF/100V EC0020470 4 CAP.CER SMD 0805 10nF 100V 10% ;X7R C26 C27 C205 C206 10nF/100V EC0020960 0 CAP. ELE SMD 10x12.5 33uF 100V 33uF/100V EC0023350 4 "DIODE.LED,SMD,0805,GREEN" LD2 LD3 LD4 LD5 KPT-2012-SGC ED0000530 1 "DIODE,SMD,SCHOTTKY RECTIFIER,3A,40V" D12 30BQ040 ED0000590 2 "DIODE,DO-214,SIDUCTOR,Vs=77V,Ipp=150" D1 D19 P0640SA ED0013180 8 "DIODE,SMD,ULTRAFST RECTIFIER,1A,600V" D2 D3 D4 D5 D13 D14 MURS160 ED0013190 2 "DIODE,SMT,SMA,1A,600V" D34 D43 US1J ED0019430 1 "DIODE,SMD,SMB,ZENER,3W,3.9V" D38 1SMB5915BT3 ED0019440 4 "DIODE,SMD,SOD-323,FAST RECTIFIER,75V,250 m D15 D16 D30 D41 BAS316TRL ED0019450 3 "DIODE,SMD,SOD-323,ZENER,323mW,18V" D29 D32 D33 BZX384-C18 ED0019470 3 "DIODE,SMD,SOD-323,ZENER,323mW,15V" D36 D37 D39 BZX384-C15 ED0020600 2 "DIODE,SMD,SMA,SCHOTTKY,20V,3A" D28 D44 B230A-13 ED0020610 3 "DIODE,SMC,TVS,70V,1500W" D17 D18 D20 SMCJ70CA ED0021160 2 "DIODE,SMC,TVS,7.5V,1500W" D10 D35 SMCJ7V.5CA ED0039210 4 "FUSE SMT,1.25A ,250V" F3 F4 F5 F6 1.25A EF0013200 1 "FUSE SMT,2A ,125V ,S.B" F2 2A/125V EF0015710 1 "IC,SMD,TSSOP-20, OCTAL-BUS TRANSCEIVER, U6 74LCX245MTC EI0000900 1 "IC,SMD,TSSOP-20,CMOS,OCTAL D-TYPE Flip-F U5 74LVC273PW EI0000910 1 "IC,SMD,SOIC-8,CMOS,EEPROM 4K (512x8) WRI T U10 AT24C04N-10SC-2.7 EI0000940 1 "IC,SMD,TSSOP-14,CMOS,QUAD 2-INPUT NAND U14 74LCX00MTC EI0001000 1 "IC,SMD,SOT-223,ID CHIP,SILICON SERIAL NUM B U9 DS2401Z EI0001100 1 IC,SMD,TSSOP-16,RS-232,TRANSCEIVER U27 MAX3232EUE EI0001150 1 "IC,SMD,SO-8,CMOS UP SUPERVISORY CIRCUI T U15 ADM706TAR EI0001270 1 IC,SMD,PQFP-64,CMOS,DUAL-SPEED FAST ETH U12 LXT971ALE EI0013280 1 "IC, LOW POWER CURRENT MODE PWM" U1 UCC2813D-2 EI0019520 1 "IC, SMD,SOT-23,PRECISION MICROPOWER SH U U22 LM4041DIM3ADJ EI0019530 1 "IC,PHOTOCOUPLER" U7 TLP124TPR EI0019550 1 "IC,VOLTAGE MONITOR,SMD,SO-8" U23 MC33161DR2 EI0019570 1 O IC-8,10-BIT,DIGITAL THERMOMETER SENSOR" U11 AD7416AR EI0027650 1 "IC,SMD,SOT-23,SWITCHING VOLTAGE REGUL A U25 LTC1772ES6 EI0032630 1 "IC,PHOTOCOUPLER X 4" U13 TCMT4100 EI0035410 1 IC,SMD, 492 PBGA, IXP425 NETWORK PROCES S U20 IXP425BDT (533MHz) EI0038780 1 "IC,SMD,TSOP-56,STRATA FLASH MEMORY,3V ( U17 E28F640J3A-110 EI0038790 2 SDRAM 8Mx16 U2 U18 MT48LC8M16A2T6-75 IT EI0038940 1 IC SMD, SOT23-5, uP SUPERVISORY CIRCUIT U26 LTC1728ES5-2.5 EI0039190 1 "IC,SMD,SOT-23,LINEAR VOLTAGE REGULATO R U19 LP2981IM5-5.0 EI0039200 1 OSCILLATOR,SMD,33.333MHz, 3.3V Y3 C67-50-48-33.333 EI0039270 1 OSCILLATOR,SMD,33.000MHz, 3.3V Y1 C67-50-48-33.000 EI0039280 1 "IC,SMD,SO-8,CMOS,DIFFERENTIAL TRANSCEI V U24 MAX3085EESA EI0039290 1 OSC,SMD,25.000Mhz 3.3V Y2 C67-50-48-25.000 EI0039300 1 CONN.BOARD,T.H,2 PIN(M) (ST),H=8.54mm JP1 JUMPER EJ0000620 1 CONN.COVER,2 PIN (F) JUMPER,H=6.3mm CJP1 2 PIN (F) JUMPER,H=6. 3 EJ0002320 1 CONN .MCX SMD FOR RF J7 MCX EJ0024110 1 CONNECTOR, SMD, MINI PCI TYPE III J3 Mini PCI -Type III EJ0038740 1 CONNECTOR, SMD, UFL TYPE J6 UFL EJ0038750 2 CONNECTOR, TH, RJ45 WITH LEDS J1 J2 RJ45_W_LEDS EJ0038760 1 "CONN.BOARD,SMT,(ST),20 PIN(10x2),(F),H=?" J9 CH81202M100-00 EJ0039030 3 INDUCTOR SMD,1206,FERRITE 80R@100Mhz 4 A L9 L10 L11 FERRITE EL0000760 4 INDUCTOR SMD,2.2uH,POWER INDUCTOR L4 L5 L7 L8 2.2uH EL0019600 1 COIL common. Mode choke 1.2mH, 2A L3 B82721-K2202-N1 EL0019640 1 FERRITE SMD,1608, 600 ohm @ 100MHz L2 FB EL0028410 1 AUDIO INDICATOR B1 SEM-1205C EL0038980 1 "SMD Common Mode Choke, 35uH, 0.5A" L6 GSTTTRF02-350 EL0039220 11 RES.NET SMD 1206 4x10R 5% RN3 RN4 RN5 RN6 R N 4x10R ER0000020 2 RES.NET SMD 1206 4x330R 5% RN1 RN22 4x330R ER0000030 30 RES SMD 0603 10K 5% 1/10W R13 R15 R16 R41 R42 10K ER0000080 2 RES SMD 0603 49.9R 1% 1/10W R80 R81 49.9R ER0000100 2 RES SMD 0603 1K 1% 1/10W R4 R241 1K ER0000120 7 RES SMD 0603 330R 1% 1/10W R75 R188 R189 R199 R 330R ER0000130 1 RES SMD 0603 22.1K 1% 1/10W R158 22.1K ER0000140 49 RES SMD 0603 0R 5% 1/10W R11 R26 R27 R31 R35 0R ER0000150 4 RES SMD 0603 100R 5% 1/10W R107 R112 R172 R17 3 100R ER0000160 1 RES SMD 0603 4.7K 5% 1/10W R145 4.7K ER0000190 2 RES SMD 0603 100K 5% 1/10W R98 R106 100K ER0000210 2 RES SMD 0603 10R 1% 1/10W R14 R225 10R ER0000230 8 RES SMD 0603 33R 5% 1/10W R9 R12 R19 R37 R38 R 33R ER0000280 1 RES SMD 0603 120R 5% 1/10W R136 120R ER0000290 2 RES SMD 2512 0.1R 1% 1W R185 R186 0.1R ER0000370 5 RES SMD 0603 1K 5% 1/10W R7 R59 R64 R175 R22 1K ER0001490 10 RES SMD 120…

Text truncated - open the document above for the full version.

Test Report

Hermon Laboratories Ltd. P.O.Box 23, Binyamina 30500, Israel Tel. +972 4628 8001 Fax. +972 4628 8277 E-mail: [email protected] Page 1 of 156 Report ID: RADRAD_FCC.16288.doc Date of Issue: 3/20/2005 Electrical TEST REPORT ACCORDING TO: FCC CFR 47 PART 90 and part 15 subpart B FOR: RadWin Ltd. Wireless Radio Transmission System Model: WinLink 1000/F49 (AirMux-200/F49, FibAir 4849, MRL-500) This report is in conformity with ISO/ IEC 17025. The A2LA logo endorsement applies only to the test methods and the standards that are listed in the scope of Hermon Laboratories accreditation. The test results relate only to the items tested. This test report shall not be reproduced in any form except in full with the written approval of Hermon Laboratories Ltd. Report ID: RADRAD_FCC.16288.doc Date of Issue: 3/20/2005 Page 2 of 156 Table of contents 1 Applicant information..................................................................................................................................................... 3 2 Equipment under test attributes .................................................................................................................................... 3 3 Manufacturer information .............................................................................................................................................. 3 4 Test details.................................................................................................................................................................... 3 5 Tests summary.............................................................................................................................................................. 4 6 EUT description............................................................................................................................................................. 5 6.1 General information....................................................................................................................................................... 5 6.2 Ports and lines .............................................................................................................................................................. 5 6.3 Support and test equipment .......................................................................................................................................... 5 6.4 Operating frequencies ................................................................................................................................................... 5 6.5 Changes made in the EUT ............................................................................................................................................ 5 6.6 Transmitter characteristics ............................................................................................................................................ 6 6.7 Test configuration.......................................................................................................................................................... 7 7 Transmitter tests according to 47CFR part 90............................................................................................................... 8 7.1 Peak output power and power spectral density test ...................................................................................................... 8 7.2 Occupied bandwidth test ............................................................................................................................................. 35 7.3 Emission mask test ..................................................................................................................................................... 49 7.4 Spurious emissions at RF antenna connector test ...................................................................................................... 62 7.5 Radiated spurious emission measurements................................................................................................................ 85 7.6 Frequency stability test.............................................................................................................................................. 120 7.7 RF exposure.............................................................................................................................................................. 122 8 Emissions tests according to 47CFR part 15 subpart B requirements ...................................................................... 124 8.1 Conducted emissions ................................................................................................................................................ 124 8.2 Radiated emission measurements ............................................................................................................................ 131 9 APPENDIX A Test equipment and ancillar…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Shlomo Weiss(Standardization Officer)
[email protected]+97237662988Fax: +97237662902

Technical Contact

Hermon LaboratoriesAlex Usoskin
[email protected]972-4628-8001

Harakevet Industrial Zone, PO Box 23 · Binyamina · Israel

Test Firm

Hermon Laboratories Ltd.Alexander Usoskin
[email protected]972-4628-8001Fax: 972-4628-8277

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
190.2104.95 GHz - 4.98 GHz19.00 mW20M0D2W20.0000000000 ppm
Confidentiality
Long Term
Grant Notes
Power output listed is conducted. The antenna used for this transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Radwin Ltd.

5 GHz High Performance PtP Outdoor Unit - FCC ID Q3K-PTP5GAX - Radwin Ltd.
Q3K-PTP5GAX

5 GHz High Performance PtP Outdoor Unit

Feb 25, 2023

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Single Carrier 5.x GHz Base Station with Beamforming Antenna, Dual Carrier 5.x GHz Base Station with Beamforming Antenna - FCC ID Q3K-NEO5X - Radwin Ltd.
Q3K-NEO5X

Single Carrier 5.x GHz Base Station with Beamforming Antenna, Dual Carrier 5.x GHz Base Station with Beamforming Antenna

Apr 27, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX
5 GHz SU/Alpha Board - FCC ID Q3K-5XSUALMOD - Radwin Ltd.
Q3K-5XSUALMOD

5 GHz SU/Alpha Board

Apr 13, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX
5 GHz MS RF Module - FCC ID Q3K-5XACMODMS - Radwin Ltd.
Q3K-5XACMODMS

5 GHz MS RF Module

Sep 13, 2020

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Point to point/point to multipoint 57-71 GHz radio transceiver - FCC ID Q3K-TRBR600G - Radwin Ltd.
Q3K-TRBR600G

Point to point/point to multipoint 57-71 GHz radio transceiver

Aug 25, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter