FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Xplore Technologies Corp of America/
  3. Q3QWM3B2915ABG

Q3QWM3B2915ABGDigital Transmission System Transceiver

Xplore Technologies Corp of America
Digital Transmission System Transceiver - FCC ID Q3QWM3B2915ABG - Xplore Technologies Corp of America
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
May 10, 2006
Application Purpose
Original Equipment
Date of Application
Mar 28, 2006
Equipment Note
Digital Transmission System Transceiver
Frequency Range
2412.00000000 - 2462.00000000
Company
Xplore Technologies Corp of America
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗
↗

External Photos

↗
↗

ID Label/Location Info

↗
↗
↗

Internal Photos

↗
↗

RF Exposure Info

↗
↗
↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

MOTION COMPUTING LE1600 AND LS800 TABLET PC MICROSOFT WINDOWS XP TABLET PC EDITION 2005 USER GUIDE Motion Computing LE1600 and LS800 Tablet PC User Guide ii Copyright Information Acrobat is a registered trademark of Adobe Systems Incorporated. Atheros. the Atheros logo, Super G, Super A/G, Wake-on-Wireless, and Wake-on-Theft are registered trademarks of Atheros Communications, Inc. AuthenTec is a registered trademark of AuthenTec, Inc. BLUETOOTH is a registered trademark owned by the Bluetooth SIG, Inc., U.S.A. and licensed to Motion Computing, Inc. Intel, Intel Inside, the Intel Inside logo, Pentium, and PROSet are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Knowles and IntelliSonic are trademarks or registered trademarks of Knowles Acoustics, Inc. Microsoft Windows, Windows XP, Windows XP Tablet PC Edition, and Windows Journal are either registered trademarks or trademarks of Microsoft Corporation in the United States and/ or other countries. Motion Computing, Speak Anywhere, and View Anywhere are trademarks or registered trademarks of Motion Computing, Inc. in the U.S. and other countries. OmniPass is a trademark of Softex, Inc. Realtek is a trademark of Realtek Semiconductor Corporation. SigmaTel is a registered trademark and Universal Jacks is a trademark of SigmaTel Corporation. Wi-Fi is a registered trademark of the Wi-Fi Alliance. Motion Computing, Inc. has made every effort to identify trademarked properties and owners on this page. All brands and product names used in this document are for identification purposes only and may be trademarks or registered trademarks of their respective companies. PATENTS: The Motion Computing products and services may be covered by one or more of the following protected inventions. Additional patents may also be pending. US PATENTS: D480,730. OTHER PATENTS: GB3009545, BG3009546, AUS154529, CAN101617, J1188539. For more information, see www.motioncomputing.com/info/patents. NOTICE: The information in this publication is subject to change without notice. MOTION COMPUTING, INC. SHALL NOT BE HELD LIABLE FOR TECHNICAL OR EDITORIAL ERRORS OR OMISSIONS CONTAINED HEREIN NOR FOR ACCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE FURNISHING, PERFORMANCE, OR USE OF THIS MATERIAL. The information contained in this document is provided “as is” without warranty of any kind and is subject to change without notice. The warranties for Motion Products are set forth in the express limited warranty statements accompanying such products. Nothing herein should be construed as constituting an additional warranty. This publication contains information protected by copyright. No part of this publication may be photocopied or reproduced in any form without prior written consent from Motion Computing, Inc. © 2005 Motion Computing, Inc. (April 2005) P/N 024-02-00xx Rev. X00 About This User Guide Motion Computing LE1600 and LS800 Tablet PC User Guide iii About This User Guide HOW TO SEARCH T HE PDF D OCUMENTATION You can search for and locate information in this user guide by using the following methods: • In the Bookmark navigation tab (left frame of PDF), select the section of the user guide you want to view. The section opens in the right frame of the PDF window. • In the Table of Contents, click on the section of the user guide you want to open. The section opens in the right frame of the window. • In the tool bar at the top of the PDF window, click the binoculars icon or select the menu Edit > Search, and enter the text describing the topic you want to view, and then tap (click) Search. Narrow your search by selecting the search settings options. • From the menu, select Edit > Find or press Ctrl+F, and type the text describing the topic you want to view, and then tap (click) Next. C AUTIONS, W ARNINGS AND N OTICES The following notices are found in this user guide: WARNING: Text set off in this way indicates that failure to follow directions in the warning could result in bodily harm or loss of life. CAUTION: Text set off in this way indicates that failure to follow directions in the CAUTION could result in damage to the equipment or loss of information. IMPORTANT: Text set off in this way presents information or instructions that should be followed or information of particular interest. NOTE: Text set off in this way presents information or instructions. M ENU ITEMS, B UTTONS, ICONS Menu items, icons, and instructions found in the procedures in this user guide are set apart by capitalizing them exactly as shown on screen. Examples are the Start menu, Dashboard, Tablet and Pen Settings icon, and Apply buttons. W RITING ON THE D ISPLAY Writing on the Motion Tablet PC digitizer display in this user guide refers to any handwritten input using the specially-designed Motion digitizer pen, that is provided. The display responds only to this pen and not to any other type of pen or to a stylus or other device such as those used with personal digital assistants (PDAs). The display surface may be damaged by ink pens or other pointed objects. I NKThe term ink refers to digital ink, i.e., hand-drawn or handwritten input and that can be displayed or converted into text. R EFERENCES TO U SING THE PEN AND P EN FUNCTION B UTTON Notations for using the Motion Digitizer Pen, which are found throughout this user guide, are described below: • Tap — Firmly tap the pen on the Tablet PC display, without pressing the function button on the pen; a tap equals a mouse left-click About This User Guide Motion Computing LE1600 and LS800 Tablet PC User Guide iv • Double-tap — Tap the pen twice on the display, without pressing the function button on the pen • Right-click — Press the function button on the pen and tap the pen on the display (equals a mouse right-click) • Press and hold — Press and hold the tip of the pen to the display with- out pressing the pen function button (equals a mouse right-click) • Tap and drag — T…

Text truncated - open the document above for the full version.

Cover Letter(s)

March15, 2006 Federal Communications Commission 7435 Oakland Mills Road Columbia, MD 21046 Gentlemen: This letter is to comply with Section 0.457 and 0.459 pertaining to confidential material. Motion Computing Incorporated would like the following documents regarding this submission for FCC ID: Q3QWM3B2915ABG and IC ID: 4587A-LE1600 to be kept confidential. 1) All Schematics (e.g. Schematic & Block Diagram LE1600.pdf) 2) All Block Diagrams (e.g. LE1600 USB port layout.ppt) 3) All Bill of Materials (e.g. LE1600 ME BOM.xls; LE1600 (BOM) Key Parts List.xls) 4) Product Specification (e.g. LE1600 Product Spec 0.80.doc) The above material contains trade secrets or technical data, which would customarily be guarded from competitors. We do not want these documents to be accessible to the general public. Please contact me if there is any further information you may need. Sincerely, Don Bobo Motion Computing Inc. 8601 Ranch Road 2222 Building 2; Austin, TX 78730 512-637-1149 (Direct) 512-637-1199 (Fax) [email protected]

Cover Letter(s)

Response to Correspondence 30672 I have uploaded the requested information again, but I do have print screen documentation that the requested items were uploade don 3/29/06 and accepted on the FCC website.

Cover Letter(s)

2 nd Response to Correspondence 30672 I have uploaded the requested information again, but I do have print screen documentation that the requested items were uploaded on 3/29/06 and accepted on the FCC website. Upon further examination of the exhibits on the FCC website, 10 additional files were missing, so they have also been uploaded.

Cover Letter(s)

Response to EA178850 Request 5-3-06 1. Additional photos have been uploaded 2. Additional SAR data uploaded. SAR report was broken into 3 parts due to size. 3. A test report has been uploaded.

External Photos

LE1600 Top LE1600 Bottom View LE1600 Left Side LE1600 Right Side

External Photos

Figure 1: Tablet PC Figure 2: Aux (left side) and Main (right side) Antenna location Figure 3: Aux and Main Antenna locations on product’s side covers Aux Main Aaaa Figure 4: Aux Antenna location inside the product Figure 5: Main Antenna location inside the product Figure 6: Product Enclosure seams (Top/Bottom)

ID Label/Location Info

Intel Pro/Wireless 2915ABG Top View Intel Pro/Wireless 2915ABG Bottom View

Internal Photos

Bluetooth Module DDR SODIMM Ram Board Bottom View DDR SODIMM Ram Board Docking Board Bottom View Docking Board Top View DSCN7790 DSCN7791 LE1600 802.11 and DDR Memory Location LE1600 Aux Antenna Location 2 LE1600 Biosboard LE1600 HDD Location LE1600 Main Antenna Location 2 LE1600 Top LCD Digitizer Motherboard Bottom Side Motherboard Top Side

Internal Photos

Aux Antenna Aux Antenna Location 2 Main Antenna Main Antenna 2

RF Exposure Info

RF Exposure The Motion Computing LE1600 series tablet is portable and will operate with a separation distance less than 20 cm between the radiating element and the user. The operating environment of the device must be described. The following categories are identified by FCC: 1) Portable – Devices that are operated with a separation distance less than 20 cm. between the radiating element and the user. These devices are usually held to the head or worn on the body. These devices usually require a SAR (Specific Absorption Rate) evaluation and report. 2) Mobile – Devices that can be re-located but maintains a minimum separation distance of 20 cm. between the radiating element and the user. These devices usually require a MPE (Maximum Permissible Exposure) evaluation. This evaluation is performed by CKC Services if it is deemed necessary. 3) Fixed – Devices with their antennas mounted outdoors on a permanent, fixed structure.

RF Exposure Info

© 2006 RF Exposure Lab, LLC This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. 2867 Progress Place, Suite 4D • Escondido, CA 92029 • U.S.A. TEL (760) 737-3131 • FAX (760) 737-9131 http://www.rfexposurelab.com CERTIFICATE OF COMPLIANCE SAR EVALUATION Motion Computing Dates of Test: March 8-11, 2006 8601 Ranch Road 2222, Building 2 Test Report Number: SAR.20060303 Austin, TX 78730 This wireless mobile and/or portable device has been shown to be compliant for localized specific absorption rate (SAR) for uncontrolled environment/general exposure limits specified in ANSI/IEEE Std. C95.1-1999 and had been tested in accordance with the measurement procedures specified in IEEE 1528-2003, OET Bulletin 65 Supp. C, RSS-102 and Safety Code 6 (See test report). I attest to the accuracy of the data. All measurements were performed by myself or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. RF Exposure Lab, LLC certifies that no party to this application has been denied FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Jay M. Moulton Vice President Certificate # 2387.01 FCC ID: Q3QWM3B2915ABG IC Certificate: 4587A-LE1600 Model(s): T004 Test Sample: Production Unit Serial No.: 20401001 Equipment Type: Tablet PC Classification: Portable Transmitter Next to Body TX Frequency Range: 2412 - 2462 MHz, 5180 - 5240 MHz, 5260 - 5320 MHz, 5745 - 5825 MHz Frequency Tolerance: 2.4 GHz - ± 25 ppm, 5 GHz - ± 20 ppm, BT - ± 75 kHz Maximum RF Output: 2.4 GHz–18 dBm, 5.2 GHz–14 dBm, 5.8 GHz–14 dBm, Bluetooth–4 dBm Conducted Signal Modulation: DSSS/OFDM/Bluetooth Antenna Type (Length): (2) Internal, Part Number DC330018100 Battery: Sanyo Model BATEDX20L4 Application Type: Certification FCC Rule Parts: Part 15E IC Specification: RSS-102 FCC ID: Q3QWM3B2915ABG © 2006 RF Exposure Lab, LLC Page 2 of 244 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Table of Contents 1. Introduction ...........................................................................................................................3 SAR Definition [5]......................................................................................................................3 2. SAR Measurement Setup .....................................................................................................4 Robotic System .........................................................................................................................4 System Hardware .....................................................................................................................4 System Description ...................................................................................................................4 E-Field Probe ALS-E-020 ......................................................................................................... 5 3. Robot Specifications .............................................................................................................7 4. Probe and Dipole Calibration ................................................................................................8 5. Phantom & Simulating Tissue Specifications........................................................................9 SAM Phantom ...........................................................................................................................9 Brain & Muscle Simulating Mixture Characterization ................................................................9 Device Holder ...........................................................................................................................9 6. Definition of Reference Points.............................................................................................10 Ear Reference Point................................................................................................................10 Device Reference Points ........................................................................................................10 7. Test Configuration Positions ...............................................................................................11 Positioning for Cheek/Touch [5] ..............................................................................................11 Positioning for Ear / 15 ̊ Tilt [5]................................................................................................12 Body Worn Configurations ......................................................................................................13 8. ANSI/IEEE C95.1 – 1999 RF Exposure Limits [2]...............................................................14 Uncontrolled Environment.......................................................................................................14 Controlled Environment .......................................................................................................... 14 9. Measurement Uncertainty ...................................................................................................15 10. System Validation ........................................................................................................... 16 Tissue Verification...................................................................................................................16 Test System Verification ......................................................................................................... 17 11. SAR Test Data Summary ................................................................................................18 Procedures Used To Establish Test Signal.............................................................................18 Device Test C…

Text truncated - open the document above for the full version.

RF Exposure Info

FCC ID: Q3QWM3B2915ABG © 2006 RF Exposure Lab, LLC Page 93 of 244 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. SAR Test Report By Operator : Jay Measurement Date : 09-Mar-2006 Starting Time : 09-Mar-2006 03:26:22 PM End Time : 09-Mar-2006 03:39:08 PM Scanning Time : 766 secs Product Data Device Name : Motion Computing Serial No. : 20401001 Type : Other Model : T004 Frequency : 2450.00 MHz Max. Transmit Pwr : 0.065 W Drift Time : 0 min(s) Length : 295 mm Width : 245 mm Depth : 23 mm Antenna Type : Internal - Main Orientation : End Power Drift-Start : 1.176 W/kg Power Drift-Finish: 1.232 W/kg Power Drift (%) : 4.774 Phantom Data Name : APREL-Uni Type : Uni-Phantom Size (mm) : 280 x 280 x 200 Serial No. : System Default Location : Center Description : Uni-Phantom Tissue Data Type : BODY Serial No. : 2450 Frequency : 2450.00 MHz Last Calib. Date : 09-Mar-2006 Temperature : 20.00 °C Ambient Temp. : 22.00 °C Humidity : 44.00 RH% Epsilon : 51.72 F/m Sigma : 1.95 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 10-Jun-2005 Frequency : 2450.00 MHz Duty Cycle Factor: 1 Conversion Factor: 4.6 Probe Sensitivity: 1.20 1.20 1.20 μV/(V/m) 2 Compression Point: 95.00 mV Offset : 1.56 mm FCC ID: Q3QWM3B2915ABG © 2006 RF Exposure Lab, LLC Page 94 of 244 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 22.00 °C Set-up Date : 09-Mar-2006 Set-up Time : 12:20:11 PM Area Scan : 5x5x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : End Separation : 0 Channel : Low - 1 1 gram SAR value : 0.962 W/kg 10 gram SAR value : 0.427 W/kg Area Scan Peak SAR : 1.261 W/kg Zoom Scan Peak SAR : 2.201 W/kg FCC ID: Q3QWM3B2915ABG © 2006 RF Exposure Lab, LLC Page 95 of 244 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. FCC ID: Q3QWM3B2915ABG © 2006 RF Exposure Lab, LLC Page 96 of 244 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. SAR Test Report By Operator : Jay Measurement Date : 09-Mar-2006 Starting Time : 09-Mar-2006 03:06:38 PM End Time : 09-Mar-2006 03:19:27 PM Scanning Time : 769 secs Product Data Device Name : Motion Computing Serial No. : 20401001 Type : Other Model : T004 Frequency : 2450.00 MHz Max. Transmit Pwr : 0.065 W Drift Time : 0 min(s) Length : 295 mm Width : 245 mm Depth : 23 mm Antenna Type : Internal - Aux Orientation : End Power Drift-Start : 0.818 W/kg Power Drift-Finish: 0.801 W/kg Power Drift (%) : -2.002 Phantom Data Name : APREL-Uni Type : Uni-Phantom Size (mm) : 280 x 280 x 200 Serial No. : System Default Location : Center Description : Uni-Phantom Tissue Data Type : BODY Serial No. : 2450 Frequency : 2450.00 MHz Last Calib. Date : 09-Mar-2006 Temperature : 20.00 °C Ambient Temp. : 22.00 °C Humidity : 44.00 RH% Epsilon : 51.72 F/m Sigma : 1.95 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 10-Jun-2005 Frequency : 2450.00 MHz Duty Cycle Factor: 1 Conversion Factor: 4.6 Probe Sensitivity: 1.20 1.20 1.20 μV/(V/m) 2 Compression Point: 95.00 mV Offset : 1.56 mm FCC ID: Q3QWM3B2915ABG © 2006 RF Exposure Lab, LLC Page 97 of 244 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 22.00 °C Set-up Date : 09-Mar-2006 Set-up Time : 12:20:11 PM Area Scan : 5x5x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : End Separation : 0 Channel : High - 11 1 gram SAR value : 0.714 W/kg 10 gram SAR value : 0.294 W/kg Area Scan Peak SAR : 0.900 W/kg Zoom Scan Peak SAR : 1.781 W/kg FCC ID: Q3QWM3B2915ABG © 2006 RF Exposure Lab, LLC Page 98 of 244 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. SAR Test Report By Operator : Jay Measurement Date : 10-Mar-2006 Starting Time : 10-Mar-2006 08:02:55 AM End Time : 10-Mar-2006 08:16:19 AM Scanning Time : 804 secs Product Data Device Name : Motion Computing Serial No. : 20401001 Type : Other Model : T004 Frequency : 2450.00 MHz Max. Transmit Pwr : 0.025 W Drift Time : 0 min(s) Length : 295 mm Width : 245 mm Depth : 23 mm Antenna Type : Internal - Main Orientation : End Power Drift-Start : 1.577 W/kg Power Drift-Finish: 1.655 W/kg Power Drift (%) : 4.924 Phantom Data Name : APREL-Uni Type : Uni-Phantom Size (mm) : 280 x 280 x 200 Serial No. : System Default Location : Center Description : Uni-Phantom Tissue Data Type : BODY Serial No. : 5200 Frequency : 5200.00 MHz Last Calib. Date : 10-Mar-2006 Temperature : 20.00 °C Ambient Temp. : 22.00 °C Humidity : 46.00 RH% Epsilon : 48.11 F/m Sigma : 5.36 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 10-Jun-2005 Frequency : 5200.00 MHz Duty Cycle Factor: 1 Conversion Factor: 2.8 Probe Sensitivity: 1.20 1.20 1.20 μV/(V/m) 2 Compression Point: 95.00 mV Offset : 1.56 mm FCC ID: Q3QWM3B2915ABG © 2006 RF Exposure Lab, LLC Page 99 of 244 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 22.00 °C Set-up Date : 10-Mar-2006 Set-up Time : 7:58:50 AM Area Scan : 5x5x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : End Separation : 0 Channel : Low - 36 1 gram SAR value : 1.083 W/kg 10 gram SAR value : 0.437 W/kg Area Scan P…

Text truncated - open the document above for the full version.

RF Exposure Info

FCC ID: Q3QWM3B2915ABG © 2006 RF Exposure Lab, LLC Page 173 of 244 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 22.00 °C Set-up Date : 11-Mar-2006 Set-up Time : 11:28:42 AM Area Scan : 5x9x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Front Separation : 0 Channel : Low - 149 1 gram SAR value : 0.336 W/kg 10 gram SAR value : 0.287 W/kg Area Scan Peak SAR : 0.344 W/kg Zoom Scan Peak SAR : 0.480 W/kg FCC ID: Q3QWM3B2915ABG © 2006 RF Exposure Lab, LLC Page 174 of 244 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. SAR Test Report By Operator : Jay Measurement Date : 11-Mar-2006 Starting Time : 11-Mar-2006 04:53:04 PM End Time : 11-Mar-2006 05:05:57 PM Scanning Time : 773 secs Product Data Device Name : Motion Computing Serial No. : 20401001 Type : Other Model : T004 Frequency : 5800.00 MHz Max. Transmit Pwr : 0.025 W Drift Time : 0 min(s) Length : 295 mm Width : 245 mm Depth : 23 mm Antenna Type : Internal - Aux Orientation : Front Power Drift-Start : 0.303 W/kg Power Drift-Finish: 0.294 W/kg Power Drift (%) : -2.970 Phantom Data Name : APREL-Uni Type : Uni-Phantom Size (mm) : 280 x 280 x 200 Serial No. : System Default Location : Center Description : Uni-Phantom Tissue Data Type : BODY Serial No. : 5800 Frequency : 5765.00 MHz Last Calib. Date : 11-Mar-2006 Temperature : 20.00 °C Ambient Temp. : 22.00 °C Humidity : 43.00 RH% Epsilon : 48.23 F/m Sigma : 5.91 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 10-Jun-2005 Frequency : 5800 MHz Duty Cycle Factor: 1 Conversion Factor: 2.1 Probe Sensitivity: 1.20 1.20 1.20 μV/(V/m) 2 Compression Point: 95 mV Offset : 1.56 mm FCC ID: Q3QWM3B2915ABG © 2006 RF Exposure Lab, LLC Page 175 of 244 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 22.00 °C Set-up Date : 11-Mar-2006 Set-up Time : 8:34:09 AM Area Scan : 5x5x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Front Separation : 0 Channel : Low - 149 1 gram SAR value : 0.252 W/kg 10 gram SAR value : 0.135 W/kg Area Scan Peak SAR : 0.316 W/kg Zoom Scan Peak SAR : 0.700 W/kg FCC ID: Q3QWM3B2915ABG © 2006 RF Exposure Lab, LLC Page 176 of 244 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. SAR Test Report By Operator : Jay Measurement Date : 11-Mar-2006 Starting Time : 11-Mar-2006 10:53:04 AM End Time : 11-Mar-2006 11:05:57 AM Scanning Time : 773 secs Product Data Device Name : Motion Computing Serial No. : 20401001 Type : Other Model : T004 Frequency : 5800.00 MHz Max. Transmit Pwr : 0.025 W Drift Time : 0 min(s) Length : 295 mm Width : 245 mm Depth : 23 mm Antenna Type : Internal - Main Orientation : Side Power Drift-Start : 1.889 W/kg Power Drift-Finish: 1.846 W/kg Power Drift (%) : -2.296 Phantom Data Name : APREL-Uni Type : Uni-Phantom Size (mm) : 280 x 280 x 200 Serial No. : System Default Location : Center Description : Uni-Phantom Tissue Data Type : BODY Serial No. : 5800 Frequency : 5765.00 MHz Last Calib. Date : 11-Mar-2006 Temperature : 20.00 °C Ambient Temp. : 22.00 °C Humidity : 43.00 RH% Epsilon : 48.23 F/m Sigma : 5.91 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 10-Jun-2005 Frequency : 5800.00 MHz Duty Cycle Factor: 1 Conversion Factor: 2.1 Probe Sensitivity: 1.20 1.20 1.20 μV/(V/m) 2 Compression Point: 95.00 mV Offset : 1.56 mm FCC ID: Q3QWM3B2915ABG © 2006 RF Exposure Lab, LLC Page 177 of 244 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. Measurement Data Crest Factor : 1 Scan Type : Complete Tissue Temp. : 20.00 °C Ambient Temp. : 22.00 °C Set-up Date : 11-Mar-2006 Set-up Time : 8:34:09 AM Area Scan : 5x5x1 : Measurement x=10mm, y=10mm, z=4mm Zoom Scan : 5x5x8 : Measurement x=8mm, y=8mm, z=4mm Other Data DUT Position : Side Separation : 0 Channel : Low - 149 1 gram SAR value : 1.344 W/kg 10 gram SAR value : 0.559 W/kg Area Scan Peak SAR : 1.848 W/kg Zoom Scan Peak SAR : 4.263 W/kg FCC ID: Q3QWM3B2915ABG © 2006 RF Exposure Lab, LLC Page 178 of 244 This report shall not be reproduced except in full without the written approval of RF Exposure Lab, LLC. SAR Test Report By Operator : Jay Measurement Date : 11-Mar-2006 Starting Time : 11-Mar-2006 10:37:52 AM End Time : 11-Mar-2006 10:50:41 AM Scanning Time : 769 secs Product Data Device Name : Motion Computing Serial No. : 20401001 Type : Other Model : T004 Frequency : 5800.00 MHz Max. Transmit Pwr : 0.025 W Drift Time : 0 min(s) Length : 295 mm Width : 245 mm Depth : 23 mm Antenna Type : Internal - Aux Orientation : End Power Drift-Start : 2.187 W/kg Power Drift-Finish: 2.122 W/kg Power Drift (%) : -2.964 Phantom Data Name : APREL-Uni Type : Uni-Phantom Size (mm) : 280 x 280 x 200 Serial No. : System Default Location : Center Description : Uni-Phantom Tissue Data Type : BODY Serial No. : 5800 Frequency : 5765.00 MHz Last Calib. Date : 11-Mar-2006 Temperature : 20.00 °C Ambient Temp. : 22.00 °C Humidity : 43.00 RH% Epsilon : 48.23 F/m Sigma : 5.91 S/m Density : 1000.00 kg/cu. m Probe Data Name : Probe 215 - RFEL Model : E020 Type : E-Field Triangle Serial No. : 215 Last Calib. Date : 10-Jun-2005 Frequency : 5800.00 MHz Duty Cycle Factor: 1 Conversion Factor: 2.1 Probe Sensitivity: 1.20 1.20 1.20 μV/(V/m) 2 Compression Point: 95.00 mV Offset : 1.56 mm FCC ID: Q3QWM3B2915ABG © 2006 RF Exposure Lab, LLC Page 179 of 244 This report shall not be reproduced exce…

Text truncated - open the document above for the full version.

Test Report

Nemko Test Report: 4L0613RUS1Rev3 Applicant: Motion Computing, Inc. 8601 RR 2222 Bldg 2 Building 1, Suite 250 Austin, TX 78730 Equipment Under Test: LE1600 Series, Model T004 (E.U.T.) In Accordance With: FCC Part 15, Subpart C, 15.247 Digital Transmission System Transceiver Tested By: Nemko Dallas Inc. 802 N. Kealy Lewisville, Texas 75057-3136 Authorized By: Tom Tidwell, Frontline Group Manager Date: March 13, 2006 Nemko Dallas FCC PART 15, SUBPART C EQUIPMENT: LE 1600 Series, Model T004 TEST REPORT NO.: 4L0613RUS1Rev3 Page 2 of 61 Table of Contents Section 1. Summary of Test Results .....................................................................3 Section 2. Equipment Under Test (E.U.T.) ...........................................................5 Section 3. Powerline Conducted Emissions ..........................................................7 Section 4. Occupied Bandwidth ..........................................................................11 Section 5. Maximum Peak Output Power ...........................................................21 Section 6. RF Exposure .......................................................................................22 Section 7 Spurious Emissions at Antenna Terminals ........................................23 Section 8. Radiated Emissions............................................................................28 Section 9. Peak Power Spectral Density .............................................................33 Section 10. Receiver Spurious Emissions...............................................................43 Section 10. Test Equipment List .............................................................................47 ANNEX A - TEST DETAILS .................................................................................48 ANNEX B - TEST DIAGRAMS.............................................................................59 Nemko Dallas FCC PART 15, SUBPART C EQUIPMENT: LE 1600 Series, Model T004 TEST REPORT NO.: 4L0613RUS1Rev3 Page 3 of 61 Section 1. Summary of Test Results Manufacturer: Motion Computing, Inc. Model No.: T004 Serial No.: None General: All measurements are traceable to national standards. These tests were conducted on a sample of the equipment for the purpose of demonstrating compliance with Part 15, Subpart C, Paragraph 15.247 for Direct Sequence Spread Spectrum devices. Radiated tests were conducted is accordance with ANSI…

Text truncated - open the document above for the full version.

Contact Information

Applicant

David J Ball(Senior Regulatory and Compliance Specialist)
[email protected]512-485-1556Fax: 512-336-7791

Technical Contact

CKC Laboratories, Inc.Mary Ellen Clayton
[email protected]209-966-5240

5046 Sierra Pines Drive · Mariposa, California · United States

Non-Technical Contact

CKC Laboratories, Inc.Mary Ellen Clayton
[email protected]209-966-5240

Test Firm

Nemko Dallas, Inc.Michael Cantwell
@.972-436-9600Fax: 972-436-2667

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz53.33 mW
Confidentiality
Long Term

Other Applications from Xplore Technologies Corp of America

Wireless Keyboard - FCC ID Q3QHMRKB001 - Xplore Technologies Corp of America
Q3QHMRKB001

Wireless Keyboard

Jul 30, 2014

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
RFID Tag Reader - FCC ID Q3QHOK6321 - Xplore Technologies Corp of America
Q3QHOK6321

RFID Tag Reader

Mar 25, 2014

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
RFID Module - FCC ID Q3QUHFRFID - Xplore Technologies Corp of America
Q3QUHFRFID

RFID Module

Dec 12, 2013

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
MC-C5/MC-F5 - FCC ID Q3QTIRFID7960 - Xplore Technologies Corp of America
Q3QTIRFID7960

MC-C5/MC-F5

Feb 01, 2012

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Tablet PC MC-C5 / MC-F5 - FCC ID Q3QIHWM622ANH - Xplore Technologies Corp of America
Q3QIHWM622ANH

Tablet PC MC-C5 / MC-F5

May 05, 2010

Equipment Class

DTS - Digital Transmission System