FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. LINKSYS LLC/
  3. Q87-E800

Q87-E800Linksys E800

LINKSYS LLC
Linksys E800 - FCC ID Q87-E800 - LINKSYS LLC
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 28, 2013
Application Purpose
Original Equipment
Date of Application
Jan 28, 2013
Equipment Note
Linksys E800
Frequency Range
2412.00000000 - 2462.00000000
Company
LINKSYS LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

Operational Description

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

User Guide Linksys E800 i Contents Linksys E800 i Contents Product overview Package contents 1 Features 1 Back view 2 Bottom view 2 Setting Up: Basics How to create a home network 3 What is a network? 3 How to set up a home network 3 Where to find more help 3 How to set up your router 3 How to start Cisco Connect 4 How to improve your wireless connection speed 5 How to test your Internet connection speed 5 How to connect devices to your network 6 How to connect a computer to your network 6 How to connect a printer 8 How to connect other devices 8 How to change your router’s name and password 10 Setting Up: Advanced How to open the browser-based utility 11 How to manually set up your router 11 How to manually set up your Internet connection 12 How to set up the DHCP server on your router 13 How to set up DHCP reservation 13 How to find your network on the Internet 14 How to clone a MAC address 15 How to connect to your corporate office using a VPN 15 How to optimize your router for gaming and voice 16 How to remotely change your router settings 17 How to enable Voice over IP on your network 18 How to configure UPnP 19 How to use a router as an access point 19 How to put your new router behind an existing router 21 To add your router to an existing router or gateway 21 To share an Internet connection 21 To extend your network 23 How to expose a device to the Internet 23 Improving Security How do I know if my network is secure? 28 Network security following a manual setup 28 How to set up wireless security using Wi-Fi Protected Setup 29 Wi-Fi Protected Setup activity light 29 Connecting a device using the Wi-Fi Protected Setup button 29 How to connect a device using its Wi-Fi Protected Setup PIN 30 How to connect a device using the router’s Wi-Fi Protected Setup PIN 30 How to connect a device manually 30 How to control access to your wireless network 31 How to improve security using the built-in firewall 32 ii Contents Linksys E800 Port Forwarding and Port Triggering How to set up port forwarding 34 How to set up port forwarding for a single port 34 How to set up port forwarding for multiple ports 35 How to set up port forwarding for a range of ports 35 How to set up port range triggering for online gaming 36 How to configure your Xbox for online gaming 37 Maintaining and Monitoring How to back up and restore your router configuration 38 How to restore factory defaults 38 How to upgrade the router’s firmware 39 How to check the status of your router 40 How to disable the Ethernet port status lights 42 How to test your Internet connection 42 How to configure and use logs 43 Specifications Linksys E800 45 1 Product overview Linksys E800 1 Product overview Package contents In addition to your router, your router package includes: •Network (Ethernet) cable •AC power adapter •Setup CD containing router setup software and documentation Features Wireless-N technology Built with leading 802 11n technology, create a powerful home wireless network in minutes Connect your computers, Internet-ready TVs, game consoles, smartphones, and other Wi-Fi devices at fast transfer rates for an unrivaled experience Advanced security Keep Wi-Fi freeloaders and Internet threats at bay with WPA2 encryption and SPI firewall to help keep your network protected Benefits of Fast Ethernet Use the four Fast Ethernet (10/100) ports for quick file sharing between computers and servers Home network ready Connect computers, printers, and more to your wireless network and the Internet QoS traffic prioritization technology delivers maximum speed and performance so you can enjoy fast downloads and reliable gaming Easy to manage Cisco Connect software helps you customize your settings and quickly add multiple devices to your network: IPv6 enabled Supports the latest Internet protocol technology to future-proof your network 2 Product overview Linksys E800 Back view Ethernet ports Wi-Fi Protected Setup button Internet port Power port •Ethernet ports—Connect Ethernet cables (also called network cables) to these Fast Ethernet (10/100) ports, color coded blue, and to wired Ethernet network devices on your network •Internet port—Connect an Ethernet cable (also called a network or Internet cable) to this port, color coded yellow, and to your modem •Wi-Fi Protected Setup™ button—Press this button to easily configure wireless security on Wi-Fi Protected Setup-enabled network devices For more information, see “How to set up wireless security using Wi-Fi Protected Setup” on page 43 •Power indicator—Stays on steadily while power is connected and following a successful Wi-Fi Protected Setup connection Flashes slowly during bootup, during firmware upgrades, and during a Wi-Fi Protected Setup connection Flashes quickly when there is a Wi-Fi Protected Setup error •Power—Connect the included AC power adapter to this port CAUTION Use only the adapter that came with your router Port activity indicator Green network activity indicator Network and Internet port •Green activity indicator—On Ethernet ports, stays on when a cable connects the port to another Ethernet port On the Internet port, stays on while connected to a modem On both port types, it flashes while transferring data Bottom view •Reset button—Press and hold this button for 5-10 seconds (until the port lights flash at the same time) to reset the router to its factory defaults You can also restore the defaults using the browser-based utility For more information, see “How to restore factory defaults” on page 61 Wi-Fi Protected Setup indicator 3 Setting Up: Basics Linksys E800 3 How to create a home network What is a network? A network is any group of devices that can communicate with each other A home network can also include Internet access, which requires a router like this one A typical home network may include multiple computers, a printer, a modem, and a router A large home network may also have a switch, additional routers, access points, and many Internet-capable media devices such …

Text truncated - open the document above for the full version.

Users Manual

Linksys Wireless N Routers and Bridges Regulatory Information Contents i Linksys Wireless N Routers and Bridges Table of Contents Regulatory Information 1 FCC Statement 1 FCC Radiation Exposure Statement 1 Safety Notices 1 Safety guidelines 1 Industry Canada Statement 2 Avis d’Industrie Canada 2 Wireless Disclaimer 2 Avis de non-responsabilité concernant les appareils sans fil 2 Mexico 2 Declaration of Conformity with Regard to EU Directive 1999/5/EC (R&TTE Directive) 3 Wireless Equipment (Wireless-AC/N/G/A/B Products) 4 National Restrictions 4 Product Usage Restrictions 5 Technical Documents on www myciscohome com 5 WEEE Information 6 User Information for Consumer Products Covered by EU Directive 2002/96/EC on Waste Electric and Electronic Equipment (WEEE) 6 1 Linksys Wireless N Routers and BridgesRegulatory Information Regulatory Information FCC Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation This product has been tested and complies with the specifications for a Class B digital device, pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used according to the instructions, may cause harmful interference to radio communications However, there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception, which is found by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •Reorient or relocate the receiving antenna •Increase the separation between the equipment or devices •Connect the equipment to an outlet other than the receiver’s •Consult a dealer or an experienced radio/TV technician for assistance FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter IEEE 802 11b or 802 11g operation of this product in the USA is firmware-limited to channels 1 through 11 Safety Notices WARNING: Do not use this product near water, for example, in a wet basement or near a swimming pool WARNING: Avoid using this product during an electrical storm There may be a remote risk of electric shock from lightning WARNING: This product contains lead, known to the State of California to cause cancer, and birth defects or other reproductive harm Wash hands after handling Safety guidelines WARNING: Use the following safety guidelines to ensure your own personal safety and to help protect your product from potential damage To reduce the risk of bodily injury, electrical shock, fire, and damage to the equipment, observe the following precautions Do not service this product except as explained in your system documentation If any of the following conditions occur, unplug the product from the electrical outlet and replace the part or contact your service provider/retailer: The power cable or plug is damaged An object has fallen into the product The product has been exposed to water The product has been dropped or damaged The product does not operate correctly when you follow the operating instructions Keep your system away from radiators and heat sources Install product in a manner and location to assure ventilation openings are not blocked Do not spill food or liquids on your system components, and never operate the product in a wet environment If the system gets wet, contact your service provider/retailer Do not push any objects into the openings of your system Doing so can cause fire or electric shock by shorting out interior components Operate the product only from the type of external power source indicated on the electrical ratings label Be sure that attached devices are electrically rated to operate with the power available in your location 2 Linksys Wireless N Routers and BridgesRegulatory Information Position system cables and power cables carefully; route cables so that they cannot be stepped on or tripped over Be sure that nothing rests on any cables Do not modify power cables or plugs Always follow your local and national wiring rules Industry Canada Statement This Class B digital apparatus complies with Canadian ICES-003 and RSS210 Operation is subject to the following two conditions: 1 This device may not cause interference and 2 This device must accept any interference, including interference that may cause undesired operation of the device This device has been designed to operate with an antenna having a maximum gain of 1 5 dBi Antenna having a higher gain is strictly prohibited per regulations of Industry Canada The required antenna impedance is 50 ohms Industry Canada Radiation Exposure Statement: This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter Avis d’Industrie Canada Cet appareil numérique de la classe B est conforme aux normes NMB-003 et RSS210 du Canada L’utilisation de ce dispositif est autorisée seulement aux conditions suivantes : 1 il ne doit pas produire de brouillage et 2 …

Text truncated - open the document above for the full version.

Cover Letter(s)

Cisco Consumer Products LLC 121 Theory Drive Irvine, CA 92617(USA) Phone: ( 949 ) 823-3188 Fax: ( 949 ) 823-3002 Federal Communications Commission Authorization and Evaluation Division Date: January 24, 2013 Confidentiality Request FCC ID: Q87-E800 Pursuant to DA 04-1705 of the Commission’s Rules, we request short-term confidential treatment for the following information until June 30, 2013 of Equipment Authorization in order to ensure sensitive business information remains confidential until the actual marketing of the device: External Photos Test Setup Photos User’s Manual Internal Photo Thank you! Sincerely yours,

External Photos

Report No.:110907E06C 1 of 12 Reference No.: 120903E08 CONSTRUCTION PHOTOS OF EUT Report No.:110907E06C 5 of 12 Reference No.: 120903E08 Adapter: HK-Q106-A12 Report No.:110907E06C 6 of 12 Reference No.: 120903E08 Adapter: MU08-6120050-A1 Report No.:110907E06C 7 of 12 Reference No.: 120903E08 Adapter: DSA-6E-12 US 120050 Report No.:110907E06C 8 of 12 Reference No.: 120903E08 Report No.:110907E06C 9 of 12 Reference No.: 120903E08 Adapter: CAD0612 Report No.:110907E06C 10 of 12 Reference No.: 120903E08 Report No.:110907E06C 11 of 12 Reference No.: 120903E08 Adapter: CAD0612L Report No.:110907E06C 12 of 12 Reference No.: 120903E08

ID Label/Location Info

FCC ID:Q87-E800 LABEL LOCATION The label will be permanently affixed at a conspicuous location on the device.

Internal Photos

Report No.:110907E06C 2 of 12 Reference No.: 120903E08 Report No.:110907E06C 3 of 12 Reference No.: 120903E08 Report No.:110907E06C 4 of 12 Reference No.: 120903E08

Operational Description

FCC ID: Q87-E800 Report No.: RF130111E03 Operational Description This device is a Linksys E800, which operates in 2.4GHz band; the maximum data rate could be up to 135Mbps which OFDM technique. If the signal to noise radio is too poor which could not support 135Mbps, the 11Mbps data rate with DSSS technique will be applied. The transmitter of the EUT is powered by 12Vdc power adapter. The antenna is Dipole antenna without antenna connector. For more detailed instruction, please take a look at the user’s manual.

RF Exposure Info

Report No.: SA110907E06D 1 of 6 Report Format Version 4.0.0 Reference No.: 111107E01, 120903E08, 130111E03 RF EXPOSURE REPORT REPORT NO.: SA110907E06D MODEL NO.: E800 FCC ID: Q87-E800 RECEIVED: Jan. 11, 2013 TESTED: Jan. 16, 2013 ISSUED: Jan. 21, 2013 APPLICANT: Cisco Consumer Products LLC ADDRESS: 121 Theory Drive Irvine, CA 92617(USA) ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory LAB ADDRESS: No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. This report should not be used by the client to claim product certification, approval, or endorsement by any government agencies. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Report No.: SA110907E06D 2 of 6 Report Format Version 4.0.0 Reference No.: 111107E01, 120903E08, 130111E03 TABLE OF CONTENTS RELEASE CONTROL RECORD ..................................................................................... 3 1. CERTIFICATION ...................................................................................................... 4 2. RF EXPOSURE LIMIT .............................................................................................. 5 3. MPE CALCULATION FORMULA ............................................................................. 5 4. CLASSIFICATION .................................................................................................... 5 5. ANTENNA GAIN....................................................................................................... 5 6. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER ........................... 6 Report No.: SA110907E06D 3 of 6 Report Format Version 4.0.0 Reference No.: 111107E01, 120903E08, 130111E03 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED SA110907E06D Original release Jan. 21, 2013 Report No.: SA110907E06D 4 of 6 Report Format Version 4.0.0 Reference No.: 111107E01, 120903E08, 130111E03 1. CERTIFICATION PRODUCT: Linksys E800 BRAND NAME: Cisco MODEL NO.: E800 TEST SAMPLE: ENGINEERING SAMPLE APPLICANT: Cisco Consumer Products LLC TESTED DATE: Jan. 16, 2013 STANDARDS: FCC Part 2 (Section 2.1091) FCC OET Bulletin 65, Supplement C (01-01) IEEE C95.1 The above equipment (Model: E800) has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. PREPARED BY : , DATE: Oct. 26, 2012 ( Lori Chung, Specialist ) APPROVED BY : , DATE: Oct. 26, 2012 ( May Chen, Deputy Manager ) Report No.: SA110907E06D 5 of 6 Report Format Version 4.0.0 Reference No.: 111107E01, 120903E08, 130111E03 2. RF EXPOSURE LIMIT LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) FREQUENCY RANGE (MHz) ELECTRIC FIELD STRENGTH (V/m) MAGNETIC FIELD STRENGTH (A/m) POWER DENSITY (mW/cm 2 ) AVERAGE TIME (minutes) LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 3. MPE CALCULATION FORMULA Pd = (Pout*G) / (4*pi*r 2 ) where Pd = power density in mW/cm 2 Pout = output power to antenna in mW G = gain of antenna in linear scale pi = 3.1416 r = distance between observation point and center of the radiator in cm 4. CLASSIFICATION The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So, this device is classified as Mobile Device. 5. ANTENNA GAIN Transmitter Circuit Gain (dBi) Antenna Type Connecter Type Frequency Range (MHz to MHz) Remark Chain (0) 4 Dipole NA 2400~2483.5 TX/RX Chain (1) 2 Dipole NA 2400~2483.5 No Function From the above antennas, antenna 1 was selected as representative mode for the test and its data was recorded in this report. Report No.: SA110907E06D 6 of 6 Report Format Version 4.0.0 Reference No.: 111107E01, 120903E08, 130111E03 6. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER FREQUENCY (MHz) MAX POWER (mW) ANTENNA GAIN (dBi) DISTANCE (cm) POWER DENSITY (mW/ cm 2 ) LIMIT (mW/cm 2 ) 2412-2462 234.423 4 20 0.11715 1 --- END --- CONCLUSION: Both of the 2.4GHz and 5GHz WLAN can transmit simultaneously, the formula of calculated the MPE is: CPD 1 / LPD 1 + CPD 2 / LPD 2 + ......etc. < 1 CPD = Calculation power density LPD = Limit of power density Therefore, the worst-case situation is 0.19107 / 1 + 0.26777 / 1 = 0.45884, which is less than “1”. This confirmed that the device comply with FCC 1.1310 MPE limit.

Test Report

Report No.: RF110907E06D 1 of 62 Report Format Version 4.0.0 Reference No.: 111107E01, 120903E08, 130111E03 FCC TEST REPORT REPORT NO.: RF110907E06D MODEL NO.: E800 FCC ID: Q87-E800 RECEIVED: Jan. 11, 2013 TESTED: Jan. 16, 2013 ISSUED: Jan. 21, 2013 APPLICANT: Cisco Consumer Products LLC ADDRESS: 121 Theory Drive Irvine, CA 92617(USA) ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory LAB ADDRESS : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. TEST LOCATION (1): No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. TEST LOCATION (2): No. 49, Ln. 206, Wende Rd., Shangshan Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Report No.: RF110907E06D 2 of 62 Report Format Version 4.0.0 Reference No.: 111107E01, 120903E08, 130111E03 Table of Contents RELEASE CONTROL RECORD ........................................................................................ 4 1. CERTIFICATION .................................................................................................... 5 2. SUMMARY OF TEST RESULTS ............................................................................ 6 2.1 MEASUREMENT UNCERTAINTY .......................................................................... 7 3. GENERAL INFORMATION ..................................................................................... 8 3.1 GENERAL DESCRIPTION OF EUT ....................................................................... 8 3.2 DESCRIPTION OF TEST MODES ....................................................................... 10 3.2.1 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL ........................ 11 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS ....................................... 14 3.4 DESCRIPTION OF SUPPORT UNITS .................................................................. 15 3.5 CONFIGURATION OF SYSTEM UNDER TEST ................................................... 16 4. TEST TYPES AND RESULTS .............................................................................. 18 4.1 CONDUCTED EMISSION MEASUREMENT ........................................................ 18 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ...................................... 18 4.1.2 TEST INSTRUMENTS .......................................................................................... 18 4.1.3 TEST PROCEDURES .......................................................................................... 19 4.1.4 DEVIATION FROM TEST STANDARD ................................................................. 19 4.1.5 TEST SETUP ....................................................................................................... 20 4.1.6 EUT OPERATING CONDITIONS ......................................................................... 20 4.1.7 TEST RESULTS (MODE 1) .................................................................................. 21 4.1.8 TEST RESULTS (MODE 2) .................................................................................. 23 4.1.9 TEST RESULTS (MODE 3) .................................................................................. 25 4.1.10 TEST RESULTS (MODE 4) .................................................................................. 27 4.1.11 TEST RESULTS (MODE 5) .................................................................................. 29 4.2 RADIATED EMISSION AND BANDEDGE MEASUREMENT ................................ 31 4.2.1 LIMITS OF RADIATED EMISSION AND BANDEDGE MEASUREMENT .............. 31 4.2.2 TEST INSTRUMENTS .......................................................................................... 32 4.2.3 TEST PROCEDURES .......................................................................................... 33 4.2.4 DEVIATION FROM TEST STANDARD ................................................................. 33 4.2.5 TEST SETUP ....................................................................................................... 34 4.2.6 EUT OPERATING CONDITIONS ......................................................................... 34 4.2.7 TEST RESULTS ................................................................................................... 35 4.3 6dB BANDWIDTH MEASUREMENT .................................................................... 48 4.3.1 LIMITS OF 6dB BANDWIDTH MEASUREMENT .................................................. 48 4.3.2 TEST INSTRUMENTS ....................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Report No.: 120927E07 1 of 7 PHOTOGRAPHS OF THE TEST CONFIGURATION CONDUCTED EMISSION TEST (With adapter 1) Report No.: 120927E07 2 of 7 CONDUCTED EMISSION TEST (With adapter 2) Report No.: 120927E07 3 of 7 CONDUCTED EMISSION TEST (With adapter 3) Report No.: 120927E07 4 of 7 CONDUCTED EMISSION TEST (With adapter 4) Report No.: 120927E07 5 of 7 CONDUCTED EMISSION TEST (With adapter 5) Report No.: 120927E07 6 of 7 RADIATED EMISSION TEST (Below 1GHz) Report No.: 120927E07 7 of 7 RADIATED EMISSION TEST (Above 1GHz)

Contact Information

Applicant

Po-Wen Cheng(Regulatory Compliance Manager)
[email protected]949-238-4518Fax: 949-265-1429

Test Firm

Bureau Veritas CPS (H.K.) Ltd., Taoyuan BranchRichard Chen
[email protected]+886-3-2600884Fax: +886-3-2115834

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.41 GHz - 2.46 GHz234.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.

Other Applications from LINKSYS LLC

WiFi Smart Light Switch with Dimmer - FCC ID Q87-WDS060 - LINKSYS LLC
Q87-WDS060

WiFi Smart Light Switch with Dimmer

Aug 11, 2020

Equipment Class

DTS - Digital Transmission System
Linksys Tri-Band Wireless-AC Router - FCC ID Q87-03564 - LINKSYS LLC
Q87-03564

Linksys Tri-Band Wireless-AC Router

Jun 28, 2020

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Linksys Tri-Band Wireless-AC Router - FCC ID Q87-03566 - LINKSYS LLC
Q87-03566

Linksys Tri-Band Wireless-AC Router

Jun 23, 2020

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Linksys MAX-STREAM AC1900+ WiFi Range Extender - FCC ID Q87-03530 - LINKSYS LLC
Q87-03530

Linksys MAX-STREAM AC1900+ WiFi Range Extender

Apr 29, 2020

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Linksys Dual-Band 802.11ax Wireless Router - FCC ID Q87-08151 - LINKSYS LLC
Q87-08151

Linksys Dual-Band 802.11ax Wireless Router

Mar 30, 2020

Equipment Class

DTS - Digital Transmission System