FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. LINKSYS LLC/
  3. Q87-EA6500V2

Q87-EA6500V2Linksys Smart Wi-Fi Router AC1750

LINKSYS LLC
Linksys Smart Wi-Fi Router AC1750 - FCC ID Q87-EA6500V2 - LINKSYS LLC
Click to zoom

Application Details

Equipment Class
NII - Unlicensed National Information Infrastructure TX
Date of Grant
Jul 09, 2013
Application Purpose
Original Equipment
Date of Application
Jul 09, 2013
Equipment Note
Linksys Smart Wi-Fi Router AC1750
Frequency Range
5180.00000000 - 5240.00000000
Company
LINKSYS LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗

Attestation Statements

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Linksys Dual-Band Routers and Bridges Regulatory Information Table of Contents i Linksys Regulatory Information Table of Contents Wireless Regulatory Information 1 FCC Statement 1 FCC Radiation Exposure Statement 1 Safety Notices 1 Industry Canada Statement 1 Avis d’Industrie Canada 2 Wireless Disclaimer 2 Avis de non-responsabilité concernant les appareils sans fil 2 Declaration of Conformity with Regard to EU Directive 1999/5/EC (R&TTE Directive) 2 Wireless Equipment (Wireless-AC/N/G/A/B Products) 3 National Restrictions 3 Product Usage Restrictions 4 Technical Documents on www myciscohome com 4 WEEE Information 5 User Information for Consumer Products Covered by EU Directive 2002/96/EC on Waste Electric and Electronic Equipment (WEEE) 5 1 Linksys Regulatory InformationWireless Regulatory Information Wireless Regulatory Information FCC Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation This product has been tested and complies with the specifications for a Class B digital device, pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used according to the instructions, may cause harmful interference to radio communications However, there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception, which is found by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •Reorient or relocate the receiving antenna •Increase the separation between the equipment or devices •Connect the equipment to an outlet other than the receiver’s •Consult a dealer or an experienced radio/TV technician for assistance FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment IEEE 802 11b or 802 11g operation of this product in the USA is firmware-limited to channels 1 through 11 The device for the band 5150-5250 MHz is only for indoor usage to reduce the potential for harmful interference to co-channel mobile satellite systems FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20 cm between the radiator and your body This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter Safety Notices WARNING: Do not use this product near water, for example, in a wet basement or near a swimming pool WARNING: Avoid using this product during an electrical storm There may be a remote risk of electric shock from lightning WARNING: This product contains lead, known to the State of California to cause cancer, and birth defects or other reproductive harm Wash hands after handling Industry Canada Statement This Class B digital apparatus complies with Canadian ICES-003 and RSS210 Operation is subject to the following two conditions: 1 This device may not cause interference and 2 This device must accept any interference, including interference that may cause undesired operation of the device The device could automatically discontinue transmission in case of absence of information to transmit, or operational failure. Note that this is not intended to prohibit transmission of control or signaling information or the use of repetitive codes where required by the technology. The maximum antenna gain permitted for devices in the band 5725-5825 MHz shall comply with the e.i.r.p. limits specified for point-to-point and non point-to-point operation as appropriate. For products available in the US/Canada market, only channel 1~11 can be operated. Selection of other channels is not possible. Industry Canada Radiation Exposure Statement This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter Restrictions in the 5 GHz Band The device for the band 5150-5250 MHz is only for indoor usage to reduce potential for harmful interference to co- channel mobile satellite systems 2 Linksys Regulatory InformationWireless Regulatory Information Avis d’Industrie Canada Cet appareil numérique de la classe B est conforme aux normes NMB-003 et RSS210 du Canada L’utilisation de ce dispositif est autorisée seulement aux conditions suivantes : 1 il ne doit pas produire de brouillage et 2 il doit accepter tout brouillage radioélectrique reçu, même si ce brouillage est susceptible de compromettre le fonctionnement du dispositif Avis d’Industrie Canada concernant l’exposition aux radiofréquences Ce matériel est conforme aux limites établies par IC en matière d’exposition aux radiofréquences dans un environnement non contrôlé Ce matériel doit être installé et utilisé à une distance d’au moins 20 cm entre l’antenne et le corps de l’utilisateur L’émetteur ne doit pas être placé près d’une autre antenne ou d’un autre émetteur, ou fonctionner avec une autre antenne ou un autre émetteur Le dispositif pourrait automatiquement cesser d'émettre en cas d'absence d'informations à transmettre, ou une défaillance opérationnelle. Notez que ce n'est pas l'intention d'interdire la transmission des informations de contrôle ou de signalisation ou l'utilisation de codes répétitifs lorsque requis par la technologie. Le gain maxima…

Text truncated - open the document above for the full version.

Users Manual

User Guide SMART Wi-Fi Router AC1750, EA6500 v2 i Contents Linksys EA-Series i Product Overview EA6500 v2 1 Wall-mounting placement 4 Setting Up: Basics How to create a home network 5 What is a network? 5 How to set up a home network 5 Where to find more help 5 How to install your router 6 How to configure your router 7 How to connect to Linksys Smart Wi-Fi 7 How to connect directly to your router 8 How to improve your wireless connection speed 8 How to change your network’s name and password 9 How to change your router’s local access password 9 How to change your router’s time zone 10 How to test your Internet connection speed 10 How to connect devices to your network 11 How to connect a computer to your network 11 How to connect a USB printer 11 How to connect other devices 12 How to view device details 13 How to set up parental controls 14 How to set parental controls 14 How to configure your guest network 15 How to back up your router configuration 16 How to customize Linksys Smart Wi-Fi 17 Using widgets 17 Customizing the Device List 17 Using an External Drive Overview 18 How to attach a USB drive 18 How to use secured folder access 19 How to set up authorized users and shared folders 19 How to access shared folders 20 How to set up your router as a media server 21 How to connect your UPnP device to the media server 22 How to remotely access storage 22 Setting Up: Advanced How to manually set up your router 24 How to manually set up your Internet connection 24 How to associate a router with your Linksys Smart Wi-Fi account 25 How to get the most out of your dual-band router 26 How to control access to your network 27 How to improve security using the built-in firewall 29 How to set up the DHCP server on your router 30 How to set up DHCP reservation 31 How to access your network on the Internet 32 How to clone a MAC address 33 How to connect to your corporate office using a VPN 33 How to optimize your router for gaming and voice 34 How to enable Voice over IP on your network 35 How to configure UPnP 36 How to use a router as an access point 37 How to put your new router behind an existing router 38 Contents ii Contents Linksys EA-Series To add your router to an existing router or gateway 38 To share an Internet connection 39 To extend your network 41 How to expose a device to the Internet 41 Port Forwarding and Port Triggering How to set up port forwarding 43 How to set up port forwarding for a single port 43 How to set up port forwarding for multiple ports 44 How to set up port forwarding for a range of ports 44 How to set up port range triggering for online gaming 45 Maintaining and Monitoring How to back up and restore your router configuration 47 How to upgrade the router’s firmware 48 How to restore factory defaults 48 How to check the status of your router 49 How to disable the Ethernet port status lights 50 How to test your Internet connection 50 How to configure and use logs 51 Troubleshooting Your router was not successfully set up 52 Windows XP Service Pack update 52 Your Internet cable is not plugged in message 53 Cannot access your router message 53 After setup 55 The Internet appears to be unavailable 55 Linksys Smart Wi-Fi does not open in your web browser 55 You cannot access Linksys Smart Wi-Fi 56 All other troubleshooting has been unsuccessful 56 Specifications Linksys EA6500 v2 57 1 Product Overview Linksys EA-Series 1 Product Overview EA6500 v2 Package contents In addition to your router, your router package includes: •Network (Ethernet) cable •AC power adapter •SimpleTap™ card Features Wireless-AC technology Built with leading 802 11ac wireless technology, your router offers maximum speed and range to create an ultra-powerful network designed for home theater performance Connect your computers, Internet-ready TVs, game consoles, smartphones and other Wi-Fi devices at blazingly fast transfer rates for an unrivaled experience The power of dual band Double your network bandwidth with simultaneous dual-band wireless-AC The dual-band feature is designed to avoid interference and optimize throughput for smoother and faster HD video streaming, file transfers, and wireless gaming SpeedBoost Higher quality antenna technology helps maintain high speeds across greater distances throughout your home Advanced security Keep Wi-Fi freeloaders and Internet threats at bay with WPA2 encryption and SPI firewall to help keep your network protected Benefits of gigabit Use the four Gigabit Ethernet (10/100/1000) ports for quick file sharing (up to 10× faster than standard Ethernet) between other Gigabit-enabled devices like computers and servers Built-in USB ports and DLNA media server The USB ports let you add an external USB drive to your network and share files at home or over the Internet It also features a built-in DLNA media server for seamless streaming of your video and media files to an Xbox 360, PS3, or other DLNA-compatible device You can also connect a USB printer and share it across your network 2 Product Overview Linksys EA-Series Home theater ready Bring the ultimate entertainment experience to your home by connecting computers, Internet-ready TVs, game consoles, media players, and more to your wireless network and the Internet Simultaneous dual-band N and QoS traffic prioritization technology delivers maximum speed and performance so you can enjoy fast downloads, smooth video and music streaming, and reliable gaming and VoIP Quick to install Linksys Smart Wi-Fi software helps you easily set up your router IPv6 enabled Supports the latest Internet protocol technology to future-proof your network Easy to manage Linksys Smart Wi-Fi software helps you customize your settings and quickly add multiple devices to your network: Separate guest network Create a separate, password-protected network for guests Parental controls Limit access time and websites with parental controls Top view Indicator light •Indicator light—Stays on steadily while power is connected and following a s…

Text truncated - open the document above for the full version.

External Photos

Report No.:121222E03 Page 1 Reference No.: 130620E03 CONSTRUCTION PHOTOS OF EUT Type 1(Vendor: MINGTEK, Vendor P/N: HN1874CG) Report No.:121222E03 Page 2 Reference No.: 130620E03 Report No.:121222E03 Page 3 Reference No.: 130620E03 Type 2(Vendor: MYJWD, Vendor P/N: DG36005-1 G) Report No.:121222E03 Page 4 Reference No.: 130620E03 Report No.:121222E03 Page 5 Reference No.: 130620E03 Model No.: CAD4212CW-1 Report No.:121222E03 Page 6 Reference No.: 130620E03 Report No.:121222E03 Page 7 Reference No.: 130620E03 Model No.: CAD4212LW-1 Report No.:121222E03 Page 8 Reference No.: 130620E03 Report No.:121222E03 Page 9 Reference No.: 130620E03 Model No.: MU42-1120350-A Report No.:121222E03 Page 10 Reference No.: 130620E03 Report No.:121222E03 Page 11 Reference No.: 130620E03 Model No.: IU42-1120350-WP Report No.:121222E03 Page 12 Reference No.: 130620E03

ID Label/Location Info

(Fig.1) FCC ID: Q87-EA6500V2 Label FCC LABEL LOCATION The label will be permanently affixed at a conspicuous location on the device. A4L-SAB4C13-006 04/17/13 04/17/13 04/17/13 CIHYI CHIU CIHYI CHIU CISCO, EA6500, US/CA/4A, SAB4-C1 A4L-SAB4C13-006 REVAGILE No. B3600-02987 04/17/13A

Internal Photos

Report No.:121222E03 Page 1 Reference No.: 130620E03 CONSTRUCTION PHOTOS OF EUT Type 1(Vendor: MINGTEK, Vendor P/N: HN1874CG) Report No.:121222E03 Page 2 Reference No.: 130620E03 Report No.:121222E03 Page 3 Reference No.: 130620E03 Report No.:121222E03 Page 4 Reference No.: 130620E03 Report No.:121222E03 Page 5 Reference No.: 130620E03 Report No.:121222E03 Page 6 Reference No.: 130620E03 Report No.:121222E03 Page 7 Reference No.: 130620E03 Report No.:121222E03 Page 8 Reference No.: 130620E03 Report No.:121222E03 Page 9 Reference No.: 130620E03 Report No.:121222E03 Page 10 Reference No.: 130620E03 Report No.:121222E03 Page 11 Reference No.: 130620E03 Report No.:121222E03 Page 12 Reference No.: 130620E03 Report No.:121222E03 Page 13 Reference No.: 130620E03 Type 2(Vendor: MYJWD, Vendor P/N: DG36005-1 G) Report No.:121222E03 Page 14 Reference No.: 130620E03 Report No.:121222E03 Page 15 Reference No.: 130620E03 Report No.:121222E03 Page 16 Reference No.: 130620E03 Report No.:121222E03 Page 17 Reference No.: 130620E03 Report No.:121222E03 Page 18 Reference No.: 130620E03 Report No.:121222E03 Page 19 Reference No.: 130620E03 Report No.:121222E03 Page 20 Reference No.: 130620E03 Report No.:121222E03 Page 21 Reference No.: 130620E03 Report No.:121222E03 Page 22 Reference No.: 130620E03 Report No.:121222E03 Page 23 Reference No.: 130620E03 Report No.:121222E03 Page 24 Reference No.: 130620E03

RF Exposure Info

Report No.: SA121222E03A R1 1 of 6 Report Format Version 5.0.0 Reference No.: 130620E03 Cancels and replaces the report No.: SA121222E03A dated June 26, 2013 RF EXPOSURE REPORT REPORT NO.: SA121222E03A MODEL NO.: EA6500 V2 FCC ID: Q87-EA6500V2 RECEIVED: Jan. 07, 2013 TESTED: Jan. 07, 2013 ISSUED: June 28, 2013 APPLICANT: Cisco Consumer Products LLC ADDRESS: 121 Theory Drive Irvine California 92617 United States ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory LAB ADDRESS: No. 81-1, Lu Liao Keng, 9th Ling,Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. This report should not be used by the client to claim product certification, approval, or endorsement by any government agencies. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Report No.: SA121222E03A R1 2 of 6 Report Format Version 5.0.0 Reference No.: 130620E03 Cancels and replaces the report No.: SA121222E03A dated June 26, 2013 TABLE OF CONTENTS RELEASE CONTROL RECORD .................................................................................... 3 1. CERTIFICATION ...................................................................................................... 4 2. RF EXPOSURE LIMIT .............................................................................................. 5 3. MPE CALCULATION FORMULA ............................................................................. 5 4. CLASSIFICATION .................................................................................................... 5 5. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER ........................... 6 Report No.: SA121222E03A R1 3 of 6 Report Format Version 5.0.0 Reference No.: 130620E03 Cancels and replaces the report No.: SA121222E03A dated June 26, 2013 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED SA121222E03A Original release June 26, 2013 SA121222E03A R1 Modified the model name. June 28, 2013 Report No.: SA121222E03A R1 4 of 6 Report Format Version 5.0.0 Reference No.: 130620E03 Cancels and replaces the report No.: SA121222E03A dated June 26, 2013 1. CERTIFICATION PRODUCT: Linksys Smart Wi-Fi Router AC1750 BRAND NAME: Cisco MODEL NO.: EA6500 V2 TEST SAMPLE: ENGINEERING SAMPLE APPLICANT: Cisco Consumer Products LLC TESTED DATE: Jan. 07, 2013 STANDARDS: FCC Part 2 (Section 2.1091) FCC OET Bulletin 65, Supplement C (01-01) IEEE C95.1 The above equipment (Model: EA6500 V2) has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. PREPARED BY : , DATE: June 28, 2013 ( Phoenix Huang, Specialist ) APPROVED BY : , DATE: June 28, 2013 ( May Chen, Manager ) Report No.: SA121222E03A R1 5 of 6 Report Format Version 5.0.0 Reference No.: 130620E03 Cancels and replaces the report No.: SA121222E03A dated June 26, 2013 2. RF EXPOSURE LIMIT LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) FREQUENCY RANGE (MHz) ELECTRIC FIELD STRENGTH (V/m) MAGNETIC FIELD STRENGTH (A/m) POWER DENSITY (mW/cm 2 ) AVERAGE TIME (minutes) LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 3. MPE CALCULATION FORMULA Pd = (Pout*G) / (4*pi*r 2 ) where Pd = power density in mW/cm 2 Pout = output power to antenna in mW G = gain of antenna in linear scale pi = 3.1416 r = distance between observation point and center of the radiator in cm 4. CLASSIFICATION The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So, this device is classified as Mobile Device. Report No.: SA121222E03A R1 6 of 6 Report Format Version 5.0.0 Reference No.: 130620E03 Cancels and replaces the report No.: SA121222E03A dated June 26, 2013 5. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER For 15.247(2.4GHz): FREQUENCY (MHz) MAX POWER (mW) ANTENNA GAIN (dBi) DISTANCE (cm) POWER DENSITY (mW/ cm 2 ) LIMIT (mW/cm 2 ) 2412-2462 255.092 3.15 20 0.10482 1 For 15.247(5GHz): FREQUENCY (MHz) MAX POWER (mW) ANTENNA GAIN (dBi) DISTANCE (cm) POWER DENSITY (mW/ cm 2 ) LIMIT (mW/cm 2 ) 5745 ~ 5825 456.334 4.79 20 0.27353 1 For 15.407(5GHz): FREQUENCY (MHz) MAX POWER (mW) ANTENNA GAIN (dBi) DISTANCE (cm) POWER DENSITY (mW/ cm 2 ) LIMIT (mW/cm 2 ) 5180 ~ 5240 32.947 4.29 20 0.01760 1 CONCLUSION: Both of the 2.4GHz and 5GHz WLAN can transmit simultaneously, the formula of calculated the MPE is: CPD 1 / LPD 1 + CPD 2 / LPD 2 + ......etc. < 1 CPD = Calculation power density LPD = Limit of power density Ther…

Text truncated - open the document above for the full version.

Test Report

Report No.: RF121222E03A R1 1 of 109 Report Format Version 5.1.0 Reference No.: 130620E03 Cancels and replaces the report No.: RF121222E03A dated June 26, 2013 FCC TEST REPORT (15.247) REPORT NO.: RF121222E03A R1 MODEL NO.: EA6500 V2 FCC ID: Q87-EA6500V2 RECEIVED: Jan. 02, 2013 TESTED: Jan. 02 to 08, 2013 ISSUED: June 28, 2013 APPLICANT: Cisco Consumer Products LLC ADDRESS: 121 Theory Drive Irvine California 92617 United States ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory LAB ADDRESS : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. TEST LOCATION (1): No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. TEST LOCATION (2): No. 49, Ln. 206, Wende Rd., Shangshan Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Report No.: RF121222E03A R1 2 of 109 Report Format Version 5.1.0 Reference No.: 130620E03 Cancels and replaces the report No.: RF121222E03A dated June 26, 2013 Table of Contents RELEASE CONTROL RECORD ........................................................................................ 5 1. CERTIFICATION .................................................................................................... 6 2. SUMMARY OF TEST RESULTS ............................................................................ 7 2.1 MEASUREMENT UNCERTAINTY .......................................................................... 8 3. GENERAL INFORMATION ..................................................................................... 9 3.1 GENERAL DESCRIPTION OF EUT ....................................................................... 9 3.2 DESCRIPTION OF TEST MODES ....................................................................... 13 3.2.1 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL ........................ 14 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS ....................................... 17 3.4 DESCRIPTION OF SUPPORT UNITS .................................................................. 18 3.5 CONFIGURATION OF SYSTEM UNDER TEST ................................................... 19 4. TEST TYPES AND RESULTS (FOR 2.4GHZ, 2.400 ~ 2.4835GHZ BAND)........... 21 4.1 CONDUCTED EMISSION MEASUREMENT ........................................................ 21 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ...................................... 21 4.1.2 TEST INSTRUMENTS .......................................................................................... 21 4.1.3 TEST PROCEDURES .......................................................................................... 22 4.1.4 DEVIATION FROM TEST STANDARD ................................................................. 22 4.1.5 TEST SETUP ....................................................................................................... 22 4.1.6 EUT OPERATING CONDITIONS ......................................................................... 23 4.1.7 TEST RESULTS (MODE 1) .................................................................................. 24 4.1.8 TEST RESULTS (MODE 2) .................................................................................. 26 4.1.9 TEST RESULTS (MODE 3) .................................................................................. 28 4.2 RADIATED EMISSION AND BANDEDGE MEASUREMENT ................................ 30 4.2.1 LIMITS OF RADIATED EMISSION AND BANDEDGE MEASUREMENT .............. 30 4.2.2 TEST INSTRUMENTS .......................................................................................... 31 4.2.3 TEST PROCEDURES .......................................................................................... 32 4.2.4 DEVIATION FROM TEST STANDARD ................................................................. 32 4.2.5 TEST SETUP ....................................................................................................... 33 4.2.6 EUT OPERATING CONDITIONS ......................................................................... 33 4.2.7 TEST RESULTS ................................................................................................... 34 4.3 6DB BANDWIDTH MEASUREMENT ................................................................... 47 4.3.1 LIMITS OF 6DB BANDWIDTH MEASUREMENT ................................................. 47 4.3.2 TEST INSTRUMENTS .......................................................................................... 47 4.3.3 TEST PROCEDURE .....................................…

Text truncated - open the document above for the full version.

Test Report

Report No.: RF121222E03A-1 R1 1 of 59 Report Format Version 5.1.0 Reference No.: 130620E03 Cancels and replaces the report No.: RF121222E03A-1 dated June 26, 2013 FCC TEST REPORT (15.407) REPORT NO.: RF121222E03A-1 R1 MODEL NO.: EA6500 V2 FCC ID: Q87-EA6500V2 RECEIVED: Jan. 02, 2013 TESTED: Jan. 02 to 07, 2013 ISSUED: June 28, 2013 APPLICANT: Cisco Consumer Products LLC ADDRESS: 121 Theory Drive Irvine California 92617 United States ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory LAB ADDRESS : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. TEST LOCATION (1): No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. TEST LOCATION (2): No. 49, Ln. 206, Wende Rd., Shangshan Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan, R.O.C. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Report No.: RF121222E03A-1 R1 2 of 59 Report Format Version 5.1.0 Reference No.: 130620E03 Cancels and replaces the report No.: RF121222E03A-1 dated June 26, 2013 Table of Contents RELEASE CONTROL RECORD ........................................................................................ 4 1. CERTIFICATION .................................................................................................... 5 2. SUMMARY OF TEST RESULTS ............................................................................ 6 2.1 MEASUREMENT UNCERTAINTY .......................................................................... 7 3. GENERAL INFORMATION ..................................................................................... 8 3.1 GENERAL DESCRIPTION OF EUT ....................................................................... 8 3.2 DESCRIPTION OF TEST MODES ....................................................................... 12 3.2.1 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL ........................ 13 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS ....................................... 15 3.4 DUTY CYCLE OF TEST SIGNAL .........…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Po-Wen Cheng(Regulatory Compliance Manager)
[email protected]949-238-4518Fax: 949-265-1429

Test Firm

Bureau Veritas CPS (H.K.) Ltd., Taoyuan BranchRichard Chen
[email protected]+886-3-2600884Fax: +886-3-2115834

Technical Specifications

#Rule PartsFrequency RangePower Output
115E5.18 GHz - 5.24 GHz33.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is the maximum combined conducted output power. End-users and responsible parties must be provided with operating and installation instructions to ensure RF exposure compliance. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. Operations in the 5.15-5.25GHz band are restricted to indoor usage only.

Other Applications from LINKSYS LLC

WiFi Smart Light Switch with Dimmer - FCC ID Q87-WDS060 - LINKSYS LLC
Q87-WDS060

WiFi Smart Light Switch with Dimmer

Aug 11, 2020

Equipment Class

DTS - Digital Transmission System
Linksys Tri-Band Wireless-AC Router - FCC ID Q87-03564 - LINKSYS LLC
Q87-03564

Linksys Tri-Band Wireless-AC Router

Jun 28, 2020

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Linksys Tri-Band Wireless-AC Router - FCC ID Q87-03566 - LINKSYS LLC
Q87-03566

Linksys Tri-Band Wireless-AC Router

Jun 23, 2020

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Linksys MAX-STREAM AC1900+ WiFi Range Extender - FCC ID Q87-03530 - LINKSYS LLC
Q87-03530

Linksys MAX-STREAM AC1900+ WiFi Range Extender

Apr 29, 2020

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Linksys Dual-Band 802.11ax Wireless Router - FCC ID Q87-08151 - LINKSYS LLC
Q87-08151

Linksys Dual-Band 802.11ax Wireless Router

Mar 30, 2020

Equipment Class

DTS - Digital Transmission System