Model No. Notebook Adapter Wireless-N WPC300N User Guide WIRELESS GHz 2.4 Wireless-N Notebook Adapter Copyright and Trademarks Specifications are subject to change without notice. Linksys is a registered trademark or trademark of Cisco Systems, Inc. and/or its affiliates in the U.S. and certain other countries. Copyright © 2006 Cisco Systems, Inc. All rights reserved. Other brands and product names are trademarks or registered trademarks of their respective holders. How to Use this User Guide This user guide has been designed to make understanding networking with the Notebook Adapter easier than ever. Look for the following items when reading this User Guide: In addition to these symbols, there are definitions for technical terms that are presented like this: Also, each figure (diagram, screenshot, or other image) is provided with a figure number and description, like this: Figure numbers and descriptions can also be found in the "List of Figures" section. This exclamation point means there is a caution or warning and is something that could damage your property or the Notebook Adapter. word: definition. This checkmark means there is a note of interest and is something you should pay special attention to while using the Notebook Adapter. This question mark provides you with a reminder about something you might need to do while using the Notebook Adapter. Figure 0-1: Sample Figure Description wpc300n-UG-60313NC BW WARNING:This product contains chemicals, including lead, known to the State of California to cause cancer, and birth defects or other reproductive harm. Wash hands after handling. Wireless-N Notebook Adapter Table of Contents Chapter 1: Introduction1 Welcome1 What’s in this User Guide?1 Chapter 2: Planning your Wireless Network3 Network Topology3 Roaming3 Network Layout4 Chapter 3: Getting to Know the Wireless-N Notebook Adapter5 The LED Indicators5 Chapter 4: Setting up and Connecting the Wireless-N Notebook Adapter6 Starting the Setup6 Connecting the Adapter7 Setting up the Adapter7 Chapter 5: Using the Wireless Network Monitor17 Accessing the Wireless Network Monitor17 Using the Wireless Network Monitor17 Link Information17 Connect20 Profiles21 Create a New Profile22 Appendix A: Troubleshooting32 Common Problems and Solutions32 Frequently Asked Questions32 Appendix B: Windows XP Wireless Zero Configuration36 Windows XP Wireless Zero Configuration36 Appendix C: Wireless Security39 Security Precautions39 Security Threats Facing Wireless Networks39 Appendix D: Windows Help42 Appendix E: Glossary43 Appendix F: Specifications48 Wireless-N Notebook Adapter Appendix G: Warranty Information50 Appendix H: Regulatory Information51 Appendix I: Contact Information58 Wireless-N Notebook Adapter List of Figures Figure 3-1: Front Panel 5 Figure 4-1: Setup Wizard’s Welcome Screen 6 Figure 4-2: Setup Wizard’s License Agreement 6 Figure 4-3: Connecting the Adapter 7 Figure 4-4: Available Wireless Networks 7 Figure 4-5: WEP Key Needed for Connection 8 Figure 4-6: PSK Personal Needed for Connection 8 Figure 4-7: PSK2 Personal Needed for Connection 9 Figure 4-8: Congratulations 9 Figure 4-9: Available Wireless Network 10 Figure 4-10: Network Settings 10 Figure 4-11: Wireless Mode 10 Figure 4-12: Ad-Hoc Mode Settings 11 Figure 4-13: Wireless Security - WEP 11 Figure 4-14: Wireless Security - PSK 12 Figure 4-15: Wireless Security - PSK2 12 Figure 4-16: Wireless Security - PSK+RADIUS - EAP-TLS 13 Figure 4-17: Wireless Security - PSK+RADIUS - PEAP 13 Figure 4-18: Wireless Security - PSK2+RADIUS - EAP-TLS 14 Figure 4-19: Wireless Security - PSK2+RADIUS - PEAP 14 Figure 4-20: Wireless Security - RADIUS - EAP-TLS 15 Figure 4-21: Wireless Security - RADIUS - PEAP 15 Figure 4-22: Confirm New Settings 16 Figure 4-23: Congratulations screen 16 Figure 5-1: Wireless Network Monitor Icon 17 Figure 5-2: Link Information 17 Figure 5-3: More Information - Wireless Network Status 18 Figure 5-4: More Information-Network Statistics 19 Figure 5-5: Connect 19 Figure 5-6: WEP Key Needed for Connection 20 Wireless-N Notebook Adapter Figure 5-7: PSK Personal Needed for Connection 20 Figure 5-8: PSK2 Personal Needed for Connection 20 Figure 5-9: Profiles 21 Figure 5-10: Creating a Profile 22 Figure 5-11: WEP Key Needed for Connection 22 Figure 5-12: PSK Personal Needed for Connection 23 Figure 5-13: PSK2 Personal Needed for Connection 23 Figure 5-14: Congratulations 23 Figure 5-15: Available Wireless Networks 24 Figure 5-16: Network Settings 24 Figure 5-17: Wireless Mode 25 Figure 5-18: Ad-Hoc Mode Settings 25 Figure 5-19: Wireless Security - WEP 26 Figure 5-20: Wireless Security - PSK Personal27 Figure 5-21: Wireless Security - PSK2 Personal27 Figure 5-22: Wireless Security - PSK+RADIUS - EAP-TLS28 Figure 5-23: Wireless Security - PSK+RADIUS - PEAP 28 Figure 5-24: Wireless Security - PSK2+RADIUS - EAP-TLS 29 Figure 5-25: Wireless Security - PSK2+RADIUS - PEAP 29 Figure 5-26: Wireless Security - RADIUS - EAP-TLS 30 Figure 5-27: Wireless Security - RADIUS - PEAP 30 Figure 5-28: Confirm New Settings 31 Figure 5-29: Congratulations 31 Figure B-1: Wireless Network Monitor Icon 36 Figure B-2: Windows XP - Use Windows XP Wireless Configuration 36 Figure B-3: Windows XP Wireless Zero Configuration Icon 36 Figure B-4: Available Wireless Network 37 Figure B-5: No Wireless Security 37 Figure B-6: Network Connection - Wireless Security 38 Figure B-7: Wireless Network Connection 38 1 Chapter 1: Introduction Welcome Wireless-N Notebook Adapter Chapter 1: Introduction Welcome Thank you for choosing the Wireless-N Notebook Adapter. Setting up your network and your Wireless-N Notebook Adapter is easier than ever. How does the Adapter do this? Like all wireless products, the Adapter allows for greater range and mobility within your wireless network, whether it’s using the Wireless-G (802.11g) or Wireless-B (802.11b) standard. But with Wireless-N, it has even better range and speed. But what does all of this mean? Networks are useful tools…
Text truncated - open the document above for the full version.
25 Chapter 5: Using the Wireless Network Monitor Create a New Profile Wireless-N Notebook Adapter 3. The Wireless Mode screen shows a choice of two wireless modes. Click the Infrastructure Mode radio button if you want to connect to a wireless router or access point. Click the Ad-Hoc Mode radio button if you want to connect to another wireless device directly without using a wireless router or access point. Enter the Wireless Network Name for your network. Infrastructure Mode - Use this mode if you want to connect to a wireless router or access point. Ad-Hoc Mode - Use this mode if you want to connect to another wireless device directly without using a wireless router or access point. Wireless Network Name - This is the wireless network name (SSID) that must be used for all the devices in your wireless network. It is case- sensitive and should be a unique name to help prevent others from entering your network. Click the Next button to continue, or click the Back button to return to the previous screen. 4. If you chose Infrastructure Mode, go to Step 5 now. If you chose Ad-Hoc Mode, the Ad-Hoc Mode Settings screen will appear. Network Mode - Select the Network Mode in which your wireless network will operate. In Mixed mode, Wireless-N, Wireless-B and Wireless-G devices can operate on the same network. In Wireless-G Only mode, no Wireless-B devices can operate in the network. Standard Channel - Select the correct channel for your wireless network. The channel you choose should match the channel set on the other devices in your wireless network. If you are unsure about which channel to use, keep the default setting Auto. Click the Next button. Click the Back button to change any settings. Figure 5-17: Wireless Mode Figure 5-18: Ad-Hoc Mode Settings 26 Chapter 5: Using the Wireless Network Monitor Create a New Profile Wireless-N Notebook Adapter 5. If your wireless network doesn’t have wireless security, select Disabled and then click the Next button to continue. Proceed to Step 6. If your wireless network has wireless security, select the method of security used: WEP, PSK, PSK2, PSK+RADIUS, PSK2+RADIUS, or RADIUS. WEP stands for Wired Equivalent Privacy. PSK is a stronger security method than WEP. PSK2 is a stronger security method than PSK. RADIUS stands for Remote Authentication Dial-In User Service. Click the Next button to continue or the Back button to return to the previous screen. Proceed to the appropriate section for your security method: WEP, PSK, PSK2, PSK+RADIUS, PSK2+RADIUS, or RADIUS. WEP WEP - Select 64-bit or 128-bit encryption Passphrase - Enter a passphrase in the Passphrase field, so a WEP key is automatically generated. It is case- sensitive and should not be longer than 16 alphanumeric characters. This passphrase must match the passphrase of your other wireless network devices and is compatible with Linksys wireless products only. (If you have any non-Linksys wireless products, enter the WEP key manually on those products.) WEP Key - The WEP key you enter must match the WEP key of your wireless network. For 64-bit encryption, enter exactly 10 hexadecimal characters. For 128-bit encryption, enter exactly 26 hexadecimal characters. Valid hexadecimal characters are “0” to “9” and “A” to “F”. Advanced Users TX Key - The default transmit key number is 1. If your network’s access point or wireless router uses transmit key number 2, 3, or 4, select the appropriate number from the TX Key drop-down box. Authentication -The default is set to Auto, so it will auto-detect for Shared Key or Open System authentication. For Shared Key authentication, both the sender and the recipient share a WEP key for authentication. For Open System authentication, the sender and the recipient do not share a WEP key for authentication. If you are not sure which authentication method to select, keep the default, Auto. Click the Next button to continue, or click the Back button to return to the previous screen. wep (wired equivalent privacy): a method of encrypting network data transmitted on a wireless network for greater security. Figure 5-19: Wireless Security - WEP 27 Chapter 5: Using the Wireless Network Monitor Create a New Profile Wireless-N Notebook Adapter PSK PSK two encryption methods, TKIP and AES, with dynamic encryption keys. Select TKIP or AES for encryption. Then enter a Pre-shared Key that is 8-63 characters in length. Encryption - Select the type of algorithm you want to use, TKIP or AES, from the Encryption drop-down menu. Pre-shared Key - Enter a Pre-shared Key of 8-63 characters in the Pre-shared Key field. Click the Next button to continue or the Back button to return to the previous screen PSK2 Enter a Pre-shared Key that is 8-63 characters in length. Pre-shared Key - Enter a Pre-shared Key of 8-63 characters in the Pre-shared Key field. Click the Next button to continue or the Back button to return to the previous screen. wpa (wi-fi protected access: a wireless security protocol using TKIP (Temporal Key Integrity Protocol) encryption, which can be used in conjunction with a RADIUS server. Figure 5-20: Wireless Security - PSK Figure 5-21: Wireless Security - PSK2 28 Chapter 5: Using the Wireless Network Monitor Create a New Profile Wireless-N Notebook Adapter PSK+RADIUS PSK+RADIUS features PSK security used in coordination with a RADIUS server. (This should only be used when a RADIUS server is connected to the Router.) PSK+RADIUS offers two authentication methods, EAP- TLS and PEAP, as well as two encryption methods, TKIP and AES, with dynamic encryption keys. Authentication - Select the authentication method your network is using, EAP-TLS or PEAP. EAP-TLS If you selected EAP-TLS, enter the login name of your wireless network in the Login Name field. Enter the name of the authentication server in the Server Name field (this is optional). From the Certificate drop-down menu, select the certificate you have installed to authenticate you on your wireless network. Select the type of…
Text truncated - open the document above for the full version.
Cisco-Linksys LLC 121 Theory Drive Irvine, CA 92617(USA) Phone: ( 949 ) 823-3188 Fax: ( 949 ) 823-3002 Federal Communications Commission 7435 Oakland Mills Road Columbia MD 21046 Subject: Request for Confidentiality FCC ID: Q87-WPC300N To Whom It May Concern: Pursuant to the provisions of Sections 0.457 and 0.459 of the Commission’s rules (47 CFR §§ 0.457, 0.459), we are requesting the Commission to withhold the following attachments as confidential document from public disclosure indefinitely. Schematic Diagram Block Diagram Theory of Operation Above mentioned document contains detailed system and equipment description are considered as proprietary information in operation of the equipment. The public disclosure of above documents might be harmful to our company and would give competitor an unfair advantage in the market. In additional to above mentioned documents, pursuant to Public Notice DA 04-1705 of the Commission’s policy, in order to comply with the marketing regulations in 47 CFR §2.803 and the importation rules in 47 CFR §2.1204, while ensuring that business sensitive information remains confidential until the actual marketing of newly authorized devices. We are requesting the commission to grant short-term confidentiality request on the following attachments for 90 days after the grant letter released External Photos Internal Photos Test Setup Photos User Manual It is our understanding that all measurement test reports, FCC ID label format and correspondent during certification review process cannot be granted as confidential documents and those information will be available for public review once the grant of equipment authorization is issued. Best Regards ------------------------------------------------------------------------------ Jennifer Yu / Associate Engineer Cisco-Linksys LLC Phone: 949-823-3188 Fax: 949-823-3002 [email protected]
Cisco-Linksys LLC 121 Theory Drive Irvine, CA 92617(USA) Phone: ( 949 ) 823-3188 Fax: ( 949 ) 823-3002 Power of Attorney To whom it may concern: We, the undersigned Cisco-Linksys LLC hereby authorize Advance Data Technology Corporation (ADT) of Taiwan to act on our behalf in all matters relating to all processes required in the FCC Part 15C approval and any communication needed with the national authority. Any and all acts carried out by ADT on our behalf shall have the same effects as acts of our own. If you have any questions regarding the authorization, please don’t hesitate to contact us. Thank you! Sincerely yours, ------------------------------------------------------------------------------- Jennifer Yu / Associate Engineer Cisco-Linksys LLC Phone: 949-823-3188 Fax: 949-823-3002 [email protected]
Page 1 CONSTRUCTION PHOTOS OF EUT
(Fig. 1) FCC ID: Q87-WPC300N FCC LABEL LOCATION The label will be permanently affixed at a conspicuous location on the device. Label
Page 2 Page 3 Page 4 Page 5
Report no.: SA950407H041Report Format Version 2.0.3 SAR TEST REPORT REPORT NO.: SA950407H04 MODEL NO.: WPC300N RECEIVED: Apr. 07, 2006 TESTED: Apr. 17, 2006 ISSUED: Apr. 17, 2006 APPLICANT: Cisco-Linksys LLC ADDRESS: 121 Theory Drive Irvine, CA 92617 (USA) ISSUED BY: Advance Data Technology Corporation LAB ADDRESS: 47 14 th Lin, Chiapau Tsun, Linko, Taipei, Taiwan, R.O.C. TEST LOCATION: No. 19, Hwa Ya 2 nd Rd., Kueishan, Taoyuan, Taiwan, R.O.C. This test report consists of 41 pages in total except Appendix. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product endorsement by CNLA, A2LA or any government agencies. The test results in the report only apply to the tested sample. Report no.: SA950407H042Report Format Version 2.0.3 TABLE OF CONTENTS 1.CERTIFICATION..................................................................................................................3 2.GENERAL INFORMATION...................................................................................................4 2.1GENERAL DESCRIPTION OF EUT................................................................................4 2.2GENERAL DESCRIPTION OF APPLIED STANDARDS..................................................5 2.3GENERAL INOFRMATION OF THE SAR SYSTEM........................................................7 2.4GENERAL DESCRIPTION OF THE SPATIAL PEAK SAR EVALUATION......................10 3.DESCRIPTION OF SUPPORT UNITS................................................................................14 4.DESCRIPTION OF TEST MODES AND CONFIGURATIONS..............................................15 4.1.DESCRIPTION OF ANTENNA LOCATION...................................................................15 4.2.DESCRIPTION OF ASSESSMENT POSITION.............................................................16 4.3.DESCRIPTION OF TEST MODE..................................................................................17 4.4.SUMMARY OF TEST RESULTS...................................................................................17 5.TEST RESULTS.................................................................................................................19 5.1TEST PROCEDURES..................................................................................................19 5.2MEASURED SAR RESULTS........................................................................................21 5.3SAR LIMITS.................................................................................................................25 5.4RECIPES FOR TISSUE SIMULATING LIQUIDS...........................................................26 5.5TEST EQUIPMENT FOR TISSUE PROPERTY............................................................28 6.SYSTEM VALIDATION.......................................................................................................29 6.1TEST EQUIPMENT......................................................................................................29 6.2TEST PROCEDURE.....................................................................................................30 6.3VALIDATION RESULTS................................................................................................32 6.4SYSTEM VALIDATION UNCERTAINTIES....................................................................33 7.MEASUREMENT SAR PROCEDURE UNCERTAINTIES....................................................34 7.1.PROBE CALIBRATION UNCERTAINTY.......................................................................34 7.2.ISOTROPY UNCERTAINTY.........................................................................................35 7.3.BOUNDARY EFFECT UNCERTAINTY.........................................................................35 7.4.PROBE LINEARITY UNCERTAINTY............................................................................36 7.5.READOUT ELECTRONICS UNCERTAINTY................................................................36 7.6.RESPONSE TIME UNCERTAINTY..............................................................................36 7.7.INTEGRATION TIME UNCERTAINTY..........................................................................37 7.8.PROBE POSITIONER MECHANICAL TOLERANCE....................................................38 7.9.PROBE POSITIONING.................................................................................................38 7.10.PHANTOM UNCERTAINTY.........................................................................................39 7.11.DASY4 UNCERTAINTY BUDGET................................................................................40 8.INFORMATION ON THE TESTING LABORATORIES.........................................................41 APPENDIX A: TEST CONFIGURATIONS AND TEST DATA APPENDIX B: ADT SAR MEASUREMENT SYSTEM APPENDIX C: PHOTOGRAPHS OF SYSTEM VALIDATION APPENDIX D: SYSTEM CERTIFICATE & CALIBRATION Report no.: SA950407H043Report Format Version 2.0.3 1. CERTIFICATION PRODUCT: Wireless-N Notebook Adapter MODEL: WPC300N BRAND: Linksys APPLICANT: Cisco-Linksys LLC TESTED : Apr. 17, 2006 TEST SAMPLE: ENGINEERING SAMPLE STANDARDS:FCC Part 2 (Section 2.1093), RSS-102 FCC OET Bulletin 65, Supplement C (01-01) The above equipment have been tested by Advance Data Technology Corporation, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. PREPARED BY:, DATE:Apr. 17, 2006 Rennie Wang TECHNICAL ACCEPTANCE:, DATE:Apr. 17, 2006 Responsible for RF Stanely Hsu APPROVED BY : , DATE: Apr. 17, 2006 Gary Chang / Supervisor Report no.: SA950407H044Report Format Version 2.0.3 2. GENERAL INFORMATION…
Text truncated - open the document above for the full version.
B - 1 APPENDIX B: ADT SAR MEASUREMENT SYSTEM C - 1 APPENDIX C: PHOTOGRAPHS OF SYSTEM VALIDATION APPENDIX D: SYSTEM CERTIFICATE & CALIBRATION D1: SAM PHANTOM D2: DOSIMETRIC E-FIELD PROBE D3: DAE D4: SYSTEM VALIDATION DIPOLE
Report No.: RF950407H041Report Format Version 2.0.4 FCC TEST REPORT REPORT NO.: RF950407H04 MODEL NO.: WPC300N RECEIVED: April 07, 2006 TESTED: April 07 to 14, 2006 ISSUED: April 15, 2006 APPLICANT:Cisco-Linksys LLC ADDRESS:121 Theory Drive Irvine, CA 92617(USA) ISSUED BY:Advance Data Technology Corporation LAB LOCATION:No. 81-1, Lu Liao Keng, 9 Ling, Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien, Taiwan, R.O.C. This test report consists of 114 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced except in full, without the written approval of our laboratory. The client should not use it to claim product endorsement by CNLA, A2LA or any government agencies. The test results in the report only apply to the tested sample. The test results in this report are traceable to the national or international standards. No. 2177-01 Report No.: RF950407H042Report Format Version 2.0.4 TABLE OF CONTENTS 1.CERTIFICATION........................................................................................... 4 2.SUMMARY OF TEST RESULTS .................................................................. 5 2.1 MEASUREMENT UNCERTAINTY ................................................................ 6 3.GENERAL INFORMATION ........................................................................... 7 3.1GENERAL DESCRIPTION OF EUT ............................................................. 7 3.2DESCRIPTION OF TEST MODES ............................................................... 8 3.2.1 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL................ 9 3.3GENERAL DESCRIPTION OF APPLIED STANDARDS............................. 13 3.4DESCRIPTION OF SUPPORT UNITS ....................................................... 14 3.5CONFIGURATION OF SYSTEM UNDER TEST......................................... 15 4.TEST TYPES AND RESULTS .................................................................... 16 4.1CONDUCTED EMISSION MEASUREMENT.............................................. 16 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ........................... 16 4.1.2 TEST INSTRUMENTS................................................................................ 16 4.1.3 TEST PROCEDURES ................................................................................ 17 4.1.4 DEVIATION FROM TEST STANDARD....................................................... 17 4.1.5 TEST SETUP.............................................................................................. 18 4.1.6 EUT OPERATING CONDITIONS ............................................................... 18 4.1.7 TEST RESULTS ......................................................................................... 19 4.2RADIATED EMISSION MEASUREMENT................................................... 25 4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT ................................ 25 4.2.2 TEST INSTRUMENTS................................................................................ 26 4.2.3 TEST PROCEDURES ................................................................................ 27 4.2.4 DEVIATION FROM TEST STANDARD....................................................... 27 4.2.5 TEST SETUP.............................................................................................. 28 4.2.6 EUT OPERATING CONDITIONS ............................................................... 28 4.2.7 TEST RESULTS ......................................................................................... 29 4.36DB BANDWIDTH MEASUREMENT ......................................................... 64 4.3.1 LIMITS OF 6DB BANDWIDTH MEASUREMENT ....................................... 64 4.3.2 TEST INSTRUMENTS................................................................................ 64 4.3.3 TEST PROCEDURE................................................................................... 64 4.3.4 DEVIATION FROM TEST STANDARD....................................................... 64 4.3.5 TEST SETUP.............................................................................................. 65 4.3.6 EUT OPERATING CONDITIONS ............................................................... 65 Report No.: RF950407H043Report Format Version 2.0.4 4.3.7 TEST RESULTS ......................................................................................... 66 4.4MAXIMUM PEAK OUTPUT POWER.......................................................... 78 4.4.1 LIMITS OF MAXIMUM PEAK OUTPUT POWER MEASUREMENT........... 78 4.4.2 INSTRUMENTS .......................................................................................... 78 4.4.3 TEST PROCEDURES ................................................................................ 78 4.4.4 DEVIATION FROM TEST STANDARD....................................................... 78 4.4.5 TEST SETUP.............................................................................................. 79 4.4.6 EUT OPERATING CONDITIONS ............................................................... 79 4.4.7 TEST RESULTS ......................................................................................... 80 4.5POWER SPECTRAL DENSITY MEASUREMENT ..................................... 82 4.5.1 LIMITS OF POWER SPECTRAL DENSITY MEASUREMENT ................... 82 4.5.2 TEST INSTRUMENTS................................................................................ 82 4.5.3 TEST PROCEDURE................................................................................... 82 4.5.4 DEVIATION FROM TEST STANDARD....................................................... 82 4.5.5 TEST SETUP.............................................................................................. 83 4.5.6 EUT OPERATING CONDITION.................................................................. 83 4.5.7 TEST RESULTS .....................................................................................…
Text truncated - open the document above for the full version.
Report No.: RF950407H04111Report Format Version 2.0.4 5. PHOTOGRAPHS OF THE TEST CONFIGURATION CONDUCTED EMISSION TEST Report No.: RF950407H04112Report Format Version 2.0.4 RADIATED EMISSION TEST
81-1 Luliaoken, 9th Lin, Wulung Tsuen Chiunglin · Hsinchu · Taiwan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 308.00 mW |

WiFi Smart Light Switch with Dimmer
Equipment Class
DTS - Digital Transmission System
Linksys Tri-Band Wireless-AC Router
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Linksys Tri-Band Wireless-AC Router
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Linksys MAX-STREAM AC1900+ WiFi Range Extender
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Linksys Dual-Band 802.11ax Wireless Router
Equipment Class
DTS - Digital Transmission System