PRELIMINARY Single Pole (One location) or 3-Way (Multi-location) Incandescent Dimmer Cat. No. RZI1Ø-1L, 1000W (Lighted) 120VAC, 60Hz INSTALLATION INSTRUCTIONS Single-Pole Wiring Application: DI-000-RZI10-00A-X0 Tools needed to install your Dimmer: Slotted/Phillips ScrewdriverElectrical Tape PliersPencil CuttersRuler Changing the color of your Dimmer: Your Dimmer may include three color options. The Dimmer ships with the White frame attached. To change color of frame, proceed as follows: Installing Dimmer by itself or with other devices: If installing Dimmer in a single device application, proceed with the INSTALLING YOUR DIMMER section. If installing Dimmer in a multi-device application, proceed as follows: MULTI-DEVICE APPLICATION: In multi-dimmer installations, the reduction of the dimmer’s capacity is required. Refer to the chart for maximum load per dimmer. INSTALLING YOUR DIMMER NOTE: Use check boxes when Steps are completed. WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring! Identifying your wiring application (most common): NOTE: If the wiring in the wall box does not resemble any of these configurations, consult a qualified electrician. Step 2 Step 3 ONOFF ONOFF ONOFF ONOFF ONOFF ONOFF ONOFFONOFF ONOFF ONOFF ONOFF ONOFF 2 4 3 1 2 4 1 5 3 3-Way 1.Line or Load (See important instruction below) 2.Neutral 3.Ground 4.First Traveler – note color 5.Second Traveler – note color NOTE: For matching remote w/LEDs installation, the First Traveler becomes Line Hot. Step 4a WIRING DIMMER: Connect wires per WIRING DIAGRAM as follows: •Green or bare copper wire in wall box to Green dimmer lead. •Line Hot wall box wire to Black dimmer lead. •Load wall box wire to Red dimmer lead. •Yellow/Red dimmer lead should have Red insulation label affixed. NOTE: If insulating label is not affixed to Yellow/Red dimmer lead, use electrical tape to cover. •Proceed to Step 5. •Pull off pre-cut insulation from dimmer leads. •Make sure that the ends of the wires from the wall box are straight (cut if necessary). •Remove insulation from each wire in the wall box as shown. •For Single-Pole Application, go to Step 4a. •For 3-Way Coordinating Remote (no LEDs) Application, go to Step 4b. WARNINGS AND CAUTIONS: •To be installed and/or used in accordance with appropriate electrical codes and regulations. •If you are unsure about any part of these instructions, consult a qualified electrician. •To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer- operated appliance. •Use with incandescent or 120V halogen fixtures only. •Vizia™ RF dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ RF remotes for multi-location dimming. •Use only one (1) Vizia™ RF dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or Vizia™ RF controllers. The remote(s) will turn the light on at the brightness level selected at the dimmer. WARNINGS AND CAUTIONS: •Dimmer may not operate with dioded lamps (Sylvania Designer 16™ or Philips PAR-16™). •Total minimum load must exceed 40W. •Dimmer may feel warm to the touch during normal operation. •Recommended minimum wall box depth is 2-1/2". •Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft. •Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture. •Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL. Single-Pole 1.Line (Hot) 2.Neutral 3.Ground 4.Load Step 4a cont’d Strip Gage (measure bare wire here or use gage on back of the dimmer) IMPORTANT: For 3-Way applications, note that one of the screw terminals from the old switch being removed will usually be a different color (Black) or labeled Common. Tag that wire with electrical tape and identify as the common (Line or Load) in both the dimmer wall box and remote wall box. 5/8" (1.6 cm) Step 1 √ Cut (if necessary) 3-Way Wiring with Coordinating Dimming or Switching Remote (no LEDs) Step 4b Step 4b cont’d WIRING DIMMER: Connect wires per WIRING DIAGRAM as follows: NOTE: When using the coordinating remote without LEDs, the dimmer can be installed on either the Line or Load side of the 3-way circuit. NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft. •Green or bare copper wire in wall box to Green dimmer lead. •Line Hot (common) wall box wire identified (tagged) when removing old switch to Black dimmer lead. •First Traveler wall box wire to Red dimmer lead (note wire color). This traveler from the dimmer must go to the terminal screw on the remote marked “RD”. •Remove Red insulating label from Yellow/Red dimmer lead. •Second Traveler wall box wire to Yellow/Red dimmer lead (note wire color). This traveler from the dimmer must go to the terminal screw on the remote marked “YL/RD”. WIRING COORDINATING REMOTE: Connect wires per WIRING DIAGRAM as follows: NOTE: Maximum wire length from dimmer to last remote is 300ft. •Green or bare copper wire in wall box to Green terminal screw. •Load wall box wire identified (tagged) when removing old switch to terminal screw marked “BK”. •First Traveler wall box wire (note color as above) to terminal screw marked “RD”. This traveler from the remote must go to the Red dimmer lead. •Second Traveler wall box wire (note color as above) to terminal screw marked “YL/RD”. This traveler from the remote must go to the Yellow/Red dimmer lead. •Remote terminal screw marked "WH" should have White insulation label affixed. NOTE: If insulating label is not affixed to terminal screw marked "WH", use electrical tape to cover. •Proceed to Step 5. Push in side at tab to release Line up tabs and press in side to attach More than Cat. No. SingleTwo Devices 2 Devices RZI1 Ø 1000W 800W650W MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE…
Text truncated - open the document above for the full version.
WARNINGS AND CAUTIONS: • To be installed and/or used in accordance with appropriate electrical codes and regulations. • If you are unsure about any part of these instructions, consult a qualified electrician. • To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a transformer operated appliance. • Use with magnetic low-voltage transformers, incandescent, or 120V halogen fixtures only. Use a Leviton electronic low-voltage dimmer to control electronic (solid state) low-voltage transformers. • When magnetic low-voltage circuits are operated at a dim level, with all lamps inoperative, excess current may flow through the transformer. To avoid possible transformer failure due to overcurrent, use a transformer that incorporates thermal protection or a fuse at the primary windings. • Vizia TM RF dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia TM RF controllers for multi-location dimming. WARNINGS AND CAUTIONS: • Use only one (1) Vizia TM RF dimmer in a multi-location circuit with up to 9 coordinating Vizia TM remotes without LEDs or Vizia TM RF remotes for multi-location. The remote(s) will turn the light on at the brightness level selected at the dimmer. • Total minimum load must exceed 40W. • Dimmer may feel warm to the touch during normal operation. • Recommended minimum wall box depth is 2-1/2". • Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft. • Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture. • Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL. Single Pole (One location) or 3-Way (Multi-location) Scene Capable Magnetic Low-Voltage Dimmer Cat. No. RZM10-1L, 1000VA (Lighted) 120VAC, 60Hz INSTALLATION INSTRUCTIONS IMPORTANT : For 3-Way applications, note that one of the screw terminals from the old switch being removed will usually be a different color (Black) or labeled Common. Tag that wire with electrical tape and identify as the common (Line or Load) in both the dimmer wall box and remote wall box. For non-standard wiring applications, refer to Wire Nut and Connector Size Chart 1 - #12 w/ 1 to 3 #14, #16 or #18 2 - #12 w/ 1 or 2 #16 or #18 1 - #14 w/ 1 to 4 #16 or #18 2 - #14 w/ 1 to 3 #16 or #18 WIRE CONNECTOR / # OF COND. COMBINATION CHART DI-000-RZM10-00A-X2 • Pull off pre-cut insulation from dimmer leads. • Make sure that the ends of the wires from the wall box are straight (cut if necessary). • Remove insulation from each wire in the wall box as shown. • For Single-Pole Application, go to Step 4a. • For 3-Way Coordinating Remote (no LEDs) Application, go to Step 4b. WIRING DIMMER: Connect wires per WIRING DIAGRAM as follows: WARNING: CONNECT A MAGNETIC LOW-VOLTAGE DIMMER ONLY TO THE PRIMARY (HIGH-VOLTAGE) SIDE OF A MAGNETIC LOW-VOLTAGE TRANSFORMER. • Green or bare copper wire in wall box to Green dimmer lead. • Line Hot wall box wire to Black dimmer lead. • Load wall box wire to Red dimmer lead. • Line Neutral wall box wire to White dimmer lead. • Yellow/Red dimmer lead should have Red insulation label affixed. NOTE: If insulating label is not affixed to Yellow/Red dimmer lead, use electrical tape to cover. • Proceed to Step 5. 3-Way Wiring with Coordinating Dimming or Switching Remote (no LEDs) Application: Step 4b BL YL/RD RD Coordinating Remote Dimmer 5 2 1 4 3 1 4 3 Black White Green Red Yellow/Red 2 5 Hot (Black) Neutral (White) Coordinating Remote (no LEDs) YL/RD RD Load Black BK WH White Line 120VA C, 60Hz Green Ground Dimmer BlackRed Yellow/ Red (PRIMARY SIDE OF MAGNETIC LOW-VOLTAGE TRANSFORMER) White Green Ground WIRING DIMMER: Connect wires per WIRING DIAGRAM as follows: WARNING: FOR MAGNETIC LOW-VOLTAGE APPLICATIONS, CONNECT DIMMER ONLY TO THE PRIMARY (HIGH-VOLTAGE) SIDE OF A MAGNETIC LOW-VOLTAGE TRANSFORMER. NOTE: When using the coordinating remote without LEDs, the dimmer can be installed on either the Line or Load side of the 3-way circuit. NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft. • Green or bare copper wire in wall box to Green dimmer lead. • Line Hot (common) wall box wire identified (tagged) when removing old switch to Black dimmer lead. • First Traveler wall box wire to Red dimmer lead (note wire color). This traveler from the dimmer must go to the terminal screw on the remote marked “RD”. • Remove Red insulating label from Yellow/Red dimmer lead. • Second Traveler wall box wire to Yellow/Red dimmer lead (note wire color). This traveler from the dimmer must go to the terminal screw on the remote marked “YL/RD”. • Line Ne utral wall box wire to White dimmer lead. Tools needed to install your Dimmer: Slotted/Phillips Screwdriver Electrical Tape Pliers Pencil Cutters Ruler MULTI-DEVICE APPLICATION In multi-dimmer installations, the reduction of the dimmer’s capacity is required. Refer to the chart for maximum load per dimmer. If installing Dimmer in a single device application, proceed with the INSTALLING YOUR DIMMER section. If installing Dimmer in a multi- device application, proceed as follows: Installing Dimmer by itself or with other devices: Changing the color of your Dimmer: Your Dimmer includes three color options. The Dimmer ships with the White frame attached. To ch ange color of frame, proceed as follows: Line up tabs and press in side to attach Push in side at tab to release INSTALLING YOUR DIMMER NOTE: Use check boxes when Steps are completed. ����� ����� ����� ����� ����� ����� ����� ����� ����� ����� ����� ����� WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring! Step 1 Step 2 2 4 3 1 Single Pole 1. Line (Hot) 2. Neutral 3. Ground 4. Load Identifying your wiring application (most common): NOTE: If the wiring in your wall box does not resemble any of the…
Text truncated - open the document above for the full version.
Model RZM10 Conducted Emissions Test Set-Up Model RZM10 – Front View 30-1000MHz Model RZM10 – Rear View 30-1000MHz Model RZM10 – Front View 1-10GHz Radiated Emissions Test Set-up Model RZM10 Occupied Bandwidth Test Set-Up Model RZM10 Duty Cycle Test Set-Up
59-25 Little Neck Parkway · Little Neck, New York · United States
| # | Rule Parts | Frequency Range | Power Output | Emission |
|---|---|---|---|---|
| 1 | 15C | 908.42 MHz - 908.42 MHz | 20.00 µW | F3D |

Lumina Wall Dimmer and Wireless Load Control Dimmer
Equipment Class
DTS - Digital Transmission System
Lumina RF Wall Switch and Wireless Load Controller
Equipment Class
DTS - Digital Transmission System
O5C04-IDW, O5C20-MDW, 06C04-IDW, 06C20-MDW, V6C04-IDW, V6C20-MDW
Equipment Class
DTS - Digital Transmission System
ZL00J-D0W Intellect Sensor Head
Equipment Class
DTS - Digital Transmission System
0XB1803 Module
Equipment Class
DTS - Digital Transmission System