FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Bury GmbH & Co KG/
  3. QZ9-CC-26

QZ9-CC-26Wireless charger with NFC card protection and digital key functionality

Bury GmbH & Co KG

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
Mar 10, 2026
Application Purpose
Original Equipment
Equipment Note
Wireless charger with NFC card protection and digital key functionality
Frequency Range
0.12600000 - 0.12600000
Company
Bury GmbH & Co KG
Country
Germany

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗
↗
↗
↗
↗

Test Report

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

BURY GmbH ▪ Robert-Koch-Straße 1-7 ▪ 32584 Löhne BURY GmbH Robert-Koch-Straße 1-7 32584 Löhne E-Mail [email protected] Internet www.bury.com Sitz der Gesellschaft/Registered office: Robert-Koch-Straße 1-7 D-32584 Löhne Bankverbindungen/Bank Account: Volksbank Schnathorst EG IBAN: EUR DE95 4926 2364 0025 9389 00 USD DE41 4926 2364 0025 9389 02 BIC: GENODEM1SNA Sparkasse Herford IBAN: EUR DE60 4945 0120 0000 0007 78 BIC: WLAHDE44XXX Registergericht/Registration Office: Bad Oeynhausen HRA 2281 Komplementärin/General Partner: BURY Verwaltungsgesellschaft mbH Bad Oeynhausen HRB 2948 Geschäftsführer/General Manager: Dipl.-Ing. Henryk Bury Gerichtsstand/place of jurisdiction: Bad Oeynhausen FB: CM / Stand 27.01.2021 / Rev.: 11 1 BURY GmbH Robert Koch Straße 1-7 32584 Löhne Germany Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA 28.01.2026 Attestation Statement according to 2.911(d)(5)(i) and 2.911(d)(5)(ii) FCC ID: QZ9-CC-26 TO WHOM IT MAY CONCERN: Hereby we certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Further we certify that, as of the date of the filing of the application, BURY GmbH (FRN 0008685315) is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, _______________ (signature & company stamp) BURY GmbH Robert Koch Straße 1-7 32584 Löhne Poland Johann Dshus [email protected]

Attestation Statements

BURY GmbH Robert-Koch-Straße 1-7 32584 Löhne E-Mail [email protected] Internet www.bury.com Sitz der Gesellschaft/Registered office: Robert-Koch-Straße 1-7 D-32584 Löhne Bankverbindungen/Bank Account: Volksbank Schnathorst EG IBAN: EUR DE95 4926 2364 0025 9389 00 USD DE41 4926 2364 0025 9389 02 BIC: GENODEM1SNA Sparkasse Herford IBAN: EUR DE60 4945 0120 0000 0007 78 BIC: WLAHDE44XXX Registergericht/Registration Office: Bad Oeynhausen HRA 2281 Komplementärin/General Partner: BURY Verwaltungsgesellschaft mbH Bad Oeynhausen HRB 2948 Geschäftsführer/General Manager: Dipl.-Ing. Henryk Bury Gerichtsstand/place of jurisdiction: Bad Oeynhausen FB: CM / Stand 27.01.2021 / Rev.: 11 1 BURY GmbH ▪ Robert-Koch-Straße 1-7 ▪ 32584 Löhne Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Ref: Attestation Statement Part 2.911(d)(7) Filing FCC ID: BURY GmbH (FRN: 0008685315) certifies that, as of the dates of this application, Americas Compliance Consulting LLC dba iCertifi “iCertifi” is our designated U.S. agent for service of process for the above referenced FCC ID. BURY GmbH accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission-related proceeding involving the equipment. iCertifi accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Americas Compliance consulting, LLC dba iCertifi FCC FRN: 0033399411 Address: 1001 SW Disk Drive, Suite 250, Bend, Oregon 97702 Contact Person: Paul Preston Tel: 866-885-4575 Email: [email protected] Sincerely, BURY GmbH Americas Compliance Consulting LLC dba iCertifi Johann Dshus Paul Preston Signature Signature

Cover Letter(s)

1 TECHNICAL SPECIFICATION Inductive coil for WPT BURY Internal part no. 54.0919.004 1. Description Inductive Coil dedicated for Wireless Power Transfer to handheld devices like smartphones and wearables. The coil will be installed in a Wireless Mobile Interface (WMI) to the plastic housing as part of the charging system. 2. Electrical specification of coil The coil is 11 turns with each individual turn constructed using 65 strands of individually insulated 80um diameter copper wire. Measurment Frequency Description Nomial Value Tolerance N/A DC resistance measured on coil terminals 62 mΩ +/- 20% 360 kHz Self-inductance in free air without magnets 7,9 μH +/- 10% 360 KHz AC resistance in free air without magnets 195 mΩ +/- 25% 128 kHz Self-inductance in free air without magnets 7,9 μH +/- 10% 128 kHz AC resistance in free air without magnets 115 mΩ +/-25% 2 3. Structure overview 3.1. Parts 3.2. Cross section 1 – Coil 2 – Ferrite 3 – DC shield

Cover Letter(s)

Document Version 1.1 2020-10-30 LONG-TERM CONFIDENTIALITY REQUEST for Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 TO WHOM IT M AY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request Long-Term Confidentiality for the following product: For the product stated above, we request Long-Term Confidentiality for exhibits which contain Block Diagram, Operational Description, Parts List/Tune Up Info, Schematics, SDR Software/Security Info. The above exhibits contain ou r trade secrets and proprietary information that could be of benefit to o ur competitors. This information will not be publicly available. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Company Name: Phone: Company Address: Fax: E-mail: Contact Name: Signature: Signature Date: Check your GC here. Click Grantee Search. FCC I D: Grantee Code Equipment Product Code

Cover Letter(s)

Document Version 1.1 2020-10-30 SHORT-TERM CONFIDENTIALITY REQUEST for Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request Short-Term Confidentiality for the following product: For the product stated above, we request Short-Term Confidentiality for exhibits which contain External Photos, Internal Photos, Test Setup Photos, User Manual. We request Short-Term Confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device which is planned for: We are aware that the Short-Term Confidentiality must be released when the product is marketed. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Company Name: Phone: Company Address: Fax: E-mail: Contact Name: Signature: Signature Date: Check your GC here. Click Grantee Search. FCC ID: Grantee Code Equipment Product Code

ID Label/Location Info

Bury Sp. z o.o. ul. Wojska Polskiego 4 39-300 Mielec, Poland 1/1 Approved by: C. Orzech Designed by: M. Mosiołek Scale: 1:1 Drawing number: Part name and number: Sheet: Part version Date Changed by Changes description Part version: 00 Marking method: Laser marking 7_2658 854_098 07 M. Mosiołek Layout for FCC PLACEMENT. 03.02 2026 VERSION FOR FCC PLACEMENT F DR - 238 A Country Canada USA USA ID 10a 11a 11b 11a 11b FCC ID: QZ9-CC-26 Model name / 型號 : CC-26 IC: 5927A-CC26 10a

RF Exposure Info

Annex C Appendix No.: 1-9362-25-03-02_TR2-A301-R01 Testing Laboratory cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken/Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://www.cetecomadvanced.com e-mail: [email protected] Appendix with Calibration data

RF Exposure Info

© cetecom advanced GmbH Page 1 of 35 TEST REPORT Test Report No.: 1-9362-25-03-02_TR2-R01 Testing Laboratory Applicant cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://cetecomadvanced.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS). The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12047-01-00. ISED Testing Laboratory Recognized Listing Number: DE0001 FCC designation number: DE0002 BURY Sp. z o.o. ul. Wojska Polskiego 4 39-300 Mielec/POLAND Manufacturer BURY Sp. z o.o. ul. Wojska Polskiego 4 39-300 Mielec/POLAND Test Standard/s KDB 447498D01v06 Mobile and Portable Devices RF Exposure Procedures and Equipment Authorization Policies KDB 680106 D01v04 Equipment Authorization of Wireless Power Transfer devices IEC PAS 63184 Assessment methods of the human exposure to electric and magnetic fields from wireless power transfer systems – Models, instrumentation, measurement and numerical methods and procedures (frequency range of 1 kHz to 30 MHz) CFR 47 – Part 1, §1.1310 RF exposure limits (100 kHz to 6 GHz) for SAR (BR) For further applied test standards please refer to section 3 of this test report. Test Item Kind of test item: Wireless charger with NFC card protection and digital key functionality Device type: Vehicle mounted device Model name: CC-26 FCC ID: QZ9-CC-26 Serial number: sample1: 8T5B6E4830125009300044919163010 sample3 8T5B6E4830125009300044719163010 sample5: 8T5B6E4830125009300051619163010 Hardware status: 003.000.000 Software status: 003.000.000 Frequency: 128 kHz / 360 kHz Antenna: Integrated charging coil Power option: 14V DC Test sample status: identical prototype Exposure category: general population / uncontrolled environment This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test Report authorised: Test performed: Alexander Hnatovskiy Marco Scigliano Lab Manager Testing Manager Radio Lab Radio Lab Test report no.: 1-9362-25-03-02_TR2-R01 © cetecom advanced GmbH Page 2 of 35 1 Table of contents 1 Table of contents ....................................................................................................................................... 2 2 General information .................................................................................................................................. 3 2.1 Notes and disclaimer ..................................................................................................................... 3 2.2 Application details ......................................................................................................................... 3 2.3 Statement of compliance ............................................................................................................... 3 2.4 Technical details ............................................................................................................................ 4 3 Test standard/s: ......................................................................................................................................... 5 3.1 RF exposure limits according CFR 47 – Part 1, §1.1310 ............................................................ 6 4 Reporting statements of conformity – decision rule ............................................................................. 7 5 Summary of Measurement Results ......................................................................................................... 7 6 Test Environment ...................................................................................................................................... 7 7 Test Set-up ................................................................................................................................................. 8 7.1 Measurement system ..................................................................................................................... 8 7.1.1 Measurement with MAGPy-H3D probe / DASY 8 WPT-System ........................................... 8 7.1.1.1 Workflow for Tier-4 Compliance Testing of IEC PAS 63184:2021 ....................................... 9 7.1.1.2 Compatibility with IEC PAS 63184:2021 ............................................................................... 9 7.1.1.3 MAGPy-Probes ................................................................................................................... 10 7.1.1.4 MAGPy-DAS: Data Acquisition System .............................................................................. 11 7.1.2 Uncertainties ........................................................................................................................ 12 7.1.2.1 Typical uncertainty of Module WPT .................................................................................... 12 7.1.3 Definition of test position and distances .............................................................................. 18 7.1.3.1 System Check and Validation ............................................................................................. 19 7.2 Test results ................................................................................................................................... 20 7.2.1 Test scenarios ..................................................................................................................... 20 7.2.2 System Checks 400kHz source: ......................................................................................... 21 7.2.3 cDASY8 Module WPT Measurement Report (Scenario 1): ..................…

Text truncated - open the document above for the full version.

RF Exposure Info

Page 1 of 18 Annex B - WPT System results Appendix No.: 1-9362-25-03-02_TR2-A201-R01 Testing Laboratory cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken/Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://www.cetecomadvanced.com e-mail: [email protected] Appendix No.: 1-9362-25-03-02_TR2-A201-R01 Page 2 of 18 Scenario 1 – Idle Mode, Sample 5, measured at 0, 10 and 20 mm distance: Appendix No.: 1-9362-25-03-02_TR2-A201-R01 Page 3 of 18 Scenario 2a – IPHONE 15 Pro (battery status at test start: 1%) – Frequency 360 kHz, tested approx. 1cm above EUT surface (touch position on phone) Appendix No.: 1-9362-25-03-02_TR2-A201-R01 Page 4 of 18 Scenario 2b – IPHONE 15 Pro (battery status at test start: 43%) – Frequency 360 kHz, tested approx. 1cm above EUT surface (touch position on phone) Appendix No.: 1-9362-25-03-02_TR2-A201-R01 Page 5 of 18 Scenario 2c – IPHONE 15 Pro (battery status at test start: 73%) – Frequency 360 kHz, tested approx. 1cm above EUT surface (touch position on phone) Appendix No.: 1-9362-25-03-02_TR2-A201-R01 Page 6 of 18 Scenario 2d – Samsung Galaxy 5G (battery status at test start: 1%) – Frequency 128 kHz, tested approx. 8 mm above EUT surface (touch position on phone) Appendix No.: 1-9362-25-03-02_TR2-A201-R01 Page 7 of 18 Scenario 2e – Samsung Galaxy 5G (battery status at test start: 42%) – Frequency 128 kHz, tested approx. 8 mm above EUT surface (touch position on phone) Appendix No.: 1-9362-25-03-02_TR2-A201-R01 Page 8 of 18 Scenario 2f – Samsung Galaxy 5G (battery status at test start: 71%) – Frequency 128 kHz, tested approx. 8 mm above EUT surface (touch position on phone) Appendix No.: 1-9362-25-03-02_TR2-A201-R01 Page 9 of 18 Scenario 2g – IPHONE 11 (battery status at test start: 5%) – Frequency 128 kHz, tested approx. 8 mm above EUT surface (touch position on phone) Appendix No.: 1-9362-25-03-02_TR2-A201-R01 Page 10 of 18 Scenario 2h – IPHONE 11 (battery status at test start: 43%) – Frequency 128 kHz, tested approx. 8 mm above EUT surface (touch position on phone) Appendix No.: 1-9362-25-03-02_TR2-A201-R01 Page 11 of 18 Scenario 2i – IPHONE 11 (battery status at test start: 75%) – Frequency 128 kHz, tested approx. 8 mm above EUT surface (touch position on phone) Appendix No.: 1-9362-25-03-02_TR2-A201-R01 Page 12 of 18 Scenario 2j – Nokia (battery status at test start: 1%) – Frequency 128 kHz, tested approx. 8 mm above EUT surface (touch position on phone) Appendix No.: 1-9362-25-03-02_TR2-A201-R01 Page 13 of 18 Scenario 2k – Nokia (battery status at test start: 59%) – Frequency 128 kHz, tested approx. 8 mm above EUT surface (touch position on phone) Appendix No.: 1-9362-25-03-02_TR2-A201-R01 Page 14 of 18 Scenario 2l – Nokia (battery status at test start: 84%) – Frequency 128 kHz, tested approx. 8 mm above EUT surface (touch position on phone) Appendix No.: 1-9362-25-03-02_TR2-A201-R01 Page 15 of 18 Scenario 3a – Sample 5 Charging with a dummy load, max. current consumption – Frequency 360 kHz measured 20cm above the EUT surface directly on the Dummy Load (MPP): Appendix No.: 1-9362-25-03-02_TR2-A201-R01 Page 16 of 18 Scenario 3b – Sample 5 Charging with a dummy load, max. current consumption – Frequency 128 kHz measured 20cm above the EUT surface directly on the Dummy Load (EPP): Appendix No.: 1-9362-25-03-02_TR2-A201-R01 Page 17 of 18 Scenario 4a – Sample 1 – CW 360 kHz starting from 0mm distance Appendix No.: 1-9362-25-03-02_TR2-A201-R01 Page 18 of 18 Scenario 4b – Sample 1 – CW 128 kHz starting from 0mm distance

RF Exposure Info

Page 1 of 24 Annex D Appendix No.: 1-9362-25-01-05_TR1-A201-R01 Testing Laboratory cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken/Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://www.cetecomadvanced.com e-mail: [email protected] Accredited Test Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS) The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate starting with the registration number: D-PL-12047-01-00. Appendix with Calibration data, Phantom certificate and system check information 2012-01-16 Test report no.: 1-9362-25-01-05_TR1-A201-R01 Page 2 of 24 1 Table of contents 1 Table of contents ....................................................................................................................................... 2 2 Calibration report “Probe EX3DV4” – SN: 7635 ..................................................................................... 3 3 Calibration certificate of Data Acquisition Unit (DAE4ip) – SN: 1842 ................................................ 12 4 Calibration report “13 MHz System validation dipole” ........................................................................ 13 5 Certificate of “ELI Phantom V8.0’’ ......................................................................................................... 19 6 Application Note System Performance Check ..................................................................................... 20 6.1 Purpose of system performance check ..................................................................................... 20 6.2 System Performance check procedure ...................................................................................... 20 6.3 Uncertainty Budget ...................................................................................................................... 21 6.4 Power set-up for validation ......................................................................................................... 23 6.5 Laboratory reflection ................................................................................................................... 24 6.6 Additional system checks ........................................................................................................... 24 Test report no.: 1-9362-25-01-05_TR1-A201-R01 Page 3 of 24 2 Calibration report “Probe EX3DV4” – SN: 7635 Test report no.: 1-9362-25-01-05_TR1-A201-R01 Page 4 of 24 Test report no.: 1-9362-25-01-05_TR1-A201-R01 Page 5 of 24 Test report no.: 1-9362-25-01-05_TR1-A201-R01 Page 6 of 24 Test report no.: 1-9362-25-01-05_TR1-A201-R01 Page 7 of 24 Test report no.: 1-9362-25-01-05_TR1-A201-R01 Page 8 of 24 Test report no.: 1-9362-25-01-05_TR1-A201-R01 Page 9 of 24 Test report no.: 1-9362-25-01-05_TR1-A201-R01 Page 10 of 24 Test report no.: 1-9362-25-01-05_TR1-A201-R01 Page 11 of 24 Test report no.: 1-9362-25-01-05_TR1-A201-R01 Page 12 of 24 3 Calibration certificate of Data Acquisition Unit (DAE4ip) – SN: 1842 Test report no.: 1-9362-25-01-05_TR1-A201-R01 Page 13 of 24 4 Calibration report “13 MHz System validation dipole” Test report no.: 1-9362-25-01-05_TR1-A201-R01 Page 14 of 24 Test report no.: 1-9362-25-01-05_TR1-A201-R01 Page 15 of 24 Test report no.: 1-9362-25-01-05_TR1-A201-R01 Page 16 of 24 Test report no.: 1-9362-25-01-05_TR1-A201-R01 Page 17 of 24 Test report no.: 1-9362-25-01-05_TR1-A201-R01 Page 18 of 24 Test report no.: 1-9362-25-01-05_TR1-A201-R01 Page 19 of 24 5 Certificate of “ELI Phantom V8.0’’ Test report no.: 1-9362-25-01-05_TR1-A201-R01 Page 20 of 24 6 Application Note System Performance Check 6.1 Purpose of system performance check The system performance check verifies that the system operates within its specifications. System and operator errors can be detected and corrected. It is recommended that the system performance check is performed prior to any usage of the system in order to guarantee reproducible results. The measurement of the Specific Absorption Rate (SAR) is a complicated task and the result depends on the proper functioning of many components and the correct settings of many parameters. Faulty results due to drift, failures or incorrect parameters might not be recognized, since they often look similar in distribution to the correct ones. The Dosimetric Assessment System DASY incorporates a system performance check procedure to test the proper functioning of the system. The system performance check uses normal SAR measurements in a simplified setup (the flat section of the SAM Twin Phantom) with a well characterized source (a matched dipole at a specified distance). This setup was selected to give a high sensitivity to all parameters that might fail or vary over time (e.g., probe, liquid parameters, and software settings) and a low sensitivity to external effects inherent in the system (e.g., positioning uncertainty of the device holder). The system performance check does not replace the calibration of the components. The accuracy of the system performance check is not sufficient for calibration purposes. It is possible to calculate the field quite accurately in this simple setup; however, due to the open field situation some factors (e.g., laboratory reflections) cannot be accounted for. Calibrations in the flat phantom are possible with transfer calibration methods, using either temperature probes or calibrated E-field probes. The system performance check also does not test the system performance for arbitrary field situations encountered during real measurements of mobile phones. These checks are performed at SPEAG by testing the components under various conditions (e.g., spherical isotropy measurements in liquid, linearity measurements, temperature variations, etc.), the results of which are used for an error estimation of the system. The system pe…

Text truncated - open the document above for the full version.

RF Exposure Info

© cetecom advanced GmbH Page 1 of 35 TEST REPORT Test Report No.: 1-9362-25-01-05_TR1-R01 Testing Laboratory Applicant cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://cetecomadvanced.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS). The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12047-01-00. ISED Testing Laboratory Recognized Listing Number: DE0001 FCC designation number: DE0002 BURY Sp. z o.o. ul. Wojska Polskiego 4 PL-39-300 Mielec/POLAND Phone: +48 017 788 46 00 Manufacturer BURY Sp. z o.o. ul. Wojska Polskiego 4 PL-39-300 Mielec/POLAND Combined Test report, applicable for: EC FCC ISED Test Item Kind of test item: Wireless charger with NFC card protection and digital key functionality Device type: fixed device Model name: CC-26 S/N serial number: 8T6B7C1990126020500150219163010 FCC-ID: QZ9-CC-26 ISED Number: 5927A-CC26 PMN: CC26 HVIN: CC26 HMN: -/- FVIN: -/- Frequency: 13.56 MHz RFID Antenna: integrated antenna Module information Max. power dissipation: 537mW (acc. customer spec Power supply: Power supply: 14.0 V DC by car battery Test sample status: identical prototype Exposure category: general population / uncontrolled environment This test report is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test Report authorised: Test performed: Alexander Hnatovskiy Eric Tuettmann Lab Manager Testing Manager Radio Labs Radio Labs Test report no.: 1-9362-25-01-05_TR1-R01 © cetecom advanced GmbH Page 2 of 35 1 Table of contents 1 Table of contents ....................................................................................................................................... 2 2 General information .................................................................................................................................. 3 2.1 Notes and disclaimer ..................................................................................................................... 3 2.2 Application details ......................................................................................................................... 3 2.3 Statement of compliance ............................................................................................................... 3 3 Test standard/s: ......................................................................................................................................... 4 3.1 RF exposure limits ......................................................................................................................... 5 4 Reporting statements of conformity – decision rule ............................................................................. 6 5 Summary of Measurement Results ......................................................................................................... 7 6 Test Environment ...................................................................................................................................... 7 7 Test Set-up ................................................................................................................................................. 8 7.1 Measurement system ..................................................................................................................... 8 7.1.1 System Description ................................................................................................................ 8 7.1.2 Test environment ................................................................................................................... 9 7.1.3 Probe description ................................................................................................................... 9 7.1.4 Phantom description ............................................................................................................ 10 7.1.5 Device holder description .................................................................................................... 11 7.1.6 Laptop Extension Kit for Device holder ............................................................................... 11 7.1.7 Scanning procedure ............................................................................................................ 12 7.1.8 Spatial Peak SAR Evaluation .............................................................................................. 16 7.1.9 Data Storage and Evaluation............................................................................................... 19 7.1.10 Tissue simulating liquids: dielectric properties .................................................................... 21 7.1.11 Tissue simulating liquids: parameters ................................................................................. 21 7.1.12 Measurement uncertainty evaluation for SAR test .............................................................. 22 7.1.13 Measurement uncertainty evaluation for System Check ..................................................... 23 7.1.14 System check ...................................................................................................................... 24 7.1.15 System check procedure ..................................................................................................... 25 7.1.16 System validation ................................................................................................................ 26 8 Detailed Test Results ................................................................................................................…

Text truncated - open the document above for the full version.

Test Report

TEST REPORT Test report no.: 1-9362-25-01-09_TR1-R03 Testing laboratory Applicant cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://cetecomadvanced.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS). The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12047-01-00. ISED Testing Laboratory Recognized Listing Number: DE0001 FCC designation number: DE0002 BURY Sp. z o.o. ul. Wojska Polskiego 4 PL-39-300 Mielec / POLAND Phone: +48 017 788 46 00 Contact: -/- -/- e-mail: -/- Manufacturer BURY Sp. z o.o. ul. Wojska Polskiego 4 PL-39-300 Mielec / POLAND Test standard/s FCC - Title 47 CFR Part 15 FCC - Title 47 of the Code of Federal Regulati…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Johann Dshus(Mr)
[email protected]Fax: +49 (0)1805 - 84 23

Technical Contact

Americas Compliance consulting, LLC dba iCertifiPaul Preston
[email protected]

1001 SW Disk Drive, Suite 250 · Bend, Oregon, 97702 · United States

Test Firm

cetecom advanced GmbHGerald Schmidt
[email protected]Fax: 49-681-598-8775

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.126 MHz - 0.126 MHz-
215C0.36 MHz - 0.36 MHz-
Confidentiality
Long Term
Grant Notes
The highest reported SAR for body-worn accessory and extremities SAR exposure conditions are < 0.1 W/kg and < 0.1 W/kg, respectively.

Other Applications from Bury GmbH & Co KG

QZ9-WMD01

Wireless charger with NFC card protection

Jul 22, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
QZ9-WMS01

Wireless charger with NFC card protection

May 08, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
QZ9-DCB

Dual Wireless charger with NFC card protection and digital key functionality

Jan 17, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Base Station - FCC ID QZ9-CG3 - Bury GmbH & Co KG
QZ9-CG3

Base Station

May 09, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Storage box with wireless charger and USB charger - FCC ID QZ9-LADESTAUFACH - Bury GmbH & Co KG
QZ9-LADESTAUFACH

Storage box with wireless charger and USB charger

Dec 02, 2020

Equipment Class

8CC - Part 18 Consumer Device