QZ9-WMS01Wireless charger with NFC card protection

Bury GmbH & Co KG

Application Details

Equipment Class
DCD - Part 15 Low Power Transmitter Below 1705 kHz
Date of Grant
May 08, 2026
Application Purpose
Original Equipment
Equipment Note
Wireless charger with NFC card protection
Frequency Range
0.12600000 - 0.12600000
Company
Bury GmbH & Co KG
Country
Germany

Documents & Files

Select a file to view

Attestation Statements

↗
↗

Cover Letter(s)

↗
↗

RF Exposure Info

↗

Test Report

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

BURY GmbH ▪ Robert-Koch-Straße 1-7 ▪ 32584 Löhne BURY GmbH Robert-Koch-Straße 1-7 32584 Löhne E-Mail [email protected] Internet www.bury.com Sitz der Gesellschaft/Registered office: Robert-Koch-Straße 1-7 D-32584 Löhne Bankverbindungen/Bank Account: Volksbank Schnathorst EG IBAN: EUR DE95 4926 2364 0025 9389 00 USD DE41 4926 2364 0025 9389 02 BIC: GENODEM1SNA Sparkasse Herford IBAN: EUR DE60 4945 0120 0000 0007 78 BIC: WLAHDE44XXX Registergericht/Registration Office: Bad Oeynhausen HRA 2281 Komplementärin/General Partner: BURY Verwaltungsgesellschaft mbH Bad Oeynhausen HRB 2948 Geschäftsführer/General Manager: Dipl.-Ing. Henryk Bury Gerichtsstand/place of jurisdiction: Bad Oeynhausen FB: CM / Stand 27.01.2021 / Rev.: 11 1 BURY GmbH Robert Koch Straße 1-7 32584 Löhne Germany Federal Communication Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA 25.04.2026 Attestation Statement according to 2.911(d)(5)(i) and 2.911(d)(5)(ii) FCC ID: QZ9-WMS01 TO WHOM IT MAY CONCERN: Hereby we certify that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Further we certify that, as of the date of the filing of the application, BURY GmbH (FRN 0008685315) is not identified on the Covered List as an entity producing “covered” equipment. Sincerely, _______________ (signature & company stamp) BURY GmbH Robert Koch Straße 1-7 32584 Löhne Germany Johann Dshus [email protected]

Attestation Statements

BURY GmbH Robert-Koch-Straße 1-7 32584 Löhne E-Mail [email protected] Internet www.bury.com Sitz der Gesellschaft/Registered office: Robert-Koch-Straße 1-7 D-32584 Löhne Bankverbindungen/Bank Account: Volksbank Schnathorst EG IBAN: EUR DE95 4926 2364 0025 9389 00 USD DE41 4926 2364 0025 9389 02 BIC: GENODEM1SNA Sparkasse Herford IBAN: EUR DE60 4945 0120 0000 0007 78 BIC: WLAHDE44XXX Registergericht/Registration Office: Bad Oeynhausen HRA 2281 Komplementärin/General Partner: BURY Verwaltungsgesellschaft mbH Bad Oeynhausen HRB 2948 Geschäftsführer/General Manager: Dipl.-Ing. Henryk Bury Gerichtsstand/place of jurisdiction: Bad Oeynhausen FB: CM / Stand 27.01.2021 / Rev.: 11 1 BURY GmbH ▪ Robert-Koch-Straße 1-7 ▪ 32584 Löhne Federal Communications Commission Authorization and Evaluation Division 7435 Oakland Mills Road Columbia, MD 21046 USA Date: Ref: Attestation Statement Part 2.911(d)(7) Filing FCC ID: BURY GmbH & (FRN: 0008685315) certifies that, as of the dates of this application, Americas Compliance Consulting LLC dba iCertifi “iCertifi” is our designated U.S. agent for service of process for the above referenced FCC ID. BURY GmbH accepts to maintain an agent for no less than one year after the grantee has terminated all marketing and importation or the conclusion of any commission-related proceeding involving the equipment. iCertifi accepts, as of the date of the filing of the application, the obligation of the designated U.S. agent for service process for the above referenced FCC ID. Designated U.S. Agent Information: Name: Americas Compliance consulting, LLC dba iCertifi FCC FRN: 0033399411 Address: 1001 SW Disk Drive, Suite 250, Bend, Oregon 97702 Contact Person: Paul Preston Tel: 866-885-4575 Email: [email protected] Sincerely, BURY GmbH Americas Compliance Consulting LLC dba iCertifi Johann Dshus Paul Preston Signature Signature

Cover Letter(s)

Document Version 1.1 2020-10-30 LONG-TERM CONFIDENTIALITY REQUEST for Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 TO WHOM IT M AY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request Long-Term Confidentiality for the following product: For the product stated above, we request Long-Term Confidentiality for exhibits which contain Block Diagram, Operational Description, Parts List/Tune Up Info, Schematics, SDR Software/Security Info. The above exhibits contain ou r trade secrets and proprietary information that could be of benefit to o ur competitors. This information will not be publicly available. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Company Name: Phone: Company Address: Fax: E-mail: Contact Name: Signature: Signature Date: Check your GC here. Click Grantee Search. FCC I D: Grantee Code Equipment Product Code

Cover Letter(s)

Document Version 1.1 2020-10-30 SHORT-TERM CONFIDENTIALITY REQUEST for Certification Service in the USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission’s Rules (47 C.F.R.) and Section §552(b)(4) of the Freedom of Information Act, we request Short-Term Confidentiality for the following product: For the product stated above, we request Short-Term Confidentiality for exhibits which contain External Photos, Internal Photos, Test Setup Photos, User Manual. We request Short-Term Confidentiality on the basis of ensuring that business sensitive information remains confidential until the actual marketing of our new device which is planned for: We are aware that the Short-Term Confidentiality must be released when the product is marketed. If you have any questions, please feel free to contact us at the address shown below. Sincerely, Company Name: Phone: Company Address: Fax: E-mail: Contact Name: Signature: Signature Date: Check your GC here. Click Grantee Search. FCC ID: Grantee Code Equipment Product Code

RF Exposure Info

Annex A201 - Test Results No. 1-1045-25-01-03_TR1-A201-R01 March 09, 2026 DescriptionDetailed test results and system checks This document is electronically signed and valid without handwritten signature. Public keys for verifcation of the electronic signatures can be requested at the testing laboratory. Marco Scigliano Testing Manager Radio Labs authorized by cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-1045-25-01-03_TR1-A201-R01 Page 1 of 10 *) SAR values were up-scaled to compensate for the unfulfilled Uncertainty budget by factor 1.03 Max SAR W/kg(1g): 0.069 Max SAR W/kg(10g): 0.028 Test distance for the test above was 0mm / touch at the EUT surface. 1.SAR results psSAR (mW/kg, rms) LIMIT: 1600Limit: 4000 1g avg.10g avg. DUTfrequency [kHz] Peak H inc (A/m, rms) Peak E inc (V/m, rms) Meas.Rep.*Meas.Rep.* CW 360kHz (1)360.32136879.667.369.327.528.3 CW 128kHz (2)127.96110524.36.06.22.52.6 cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-1045-25-01-03_TR1-A201-R01 Page 2 of 10 Device under test •Info360 kHz CW Sample •Serial numberSample 1 •ScenarioMin. peak search frequency [kHz] 300 Max. peak search frequency [kHz] 400 Envelope smoothing window [-] 12000 Adaptive slice decay threshold [-] 0.99 Acquisition time [s] 0.2 Tool info •DASY software versionDASY8 Module WPT 2.8.0.5947 •Probe model, serial no. and configuration dateMAGPy-8H3D+E3Dv2, WP000009, 2025/11/11 •Software version2.8.9, backend: 2.2.36 Scan info •Center locationx:-60.00 μm, y:-50.00 μm, z:124.96 mm •Dimensionsx:168.7mm, y:168.6mm, z:81.0mm •Resolutionx:7.33 mm, y:7.33 mm, z:7.33 mm •Completed on2025/11/19 18:05:17 Measurement results •Maximum H-field [rms]magnitude:571.47 A/mx:88.78 A/m, y:162.75 A/m, z:540.57 A/m •Maximum H-field location relative to DUTx:-3.67 mm, y:-3.67 mm, z:8.50 mm •Maximum E-field [rms]magnitude:79.59 V/mx:69.21 V/m, y:38.88 V/m, z:5.82 V/m •Maximum E-field location relative to DUTx:0.00 m, y:14.67 mm, z:0.00 m •Distance to -20.0dB boundary26.44 mm •Offset relative to DUTx:0.00 m, y:0.00 m, z:1.00 mm 2.Result for Sample 1 - CW 360 kHz (1) cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-1045-25-01-03_TR1-A201-R01 Page 3 of 10 H-field magnitude [rms] at center locationH-field magnitude [rms] at lowest plane cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-1045-25-01-03_TR1-A201-R01 Page 4 of 10 Incident fields and induced fields in the homogeous phantom at the peak frequency f = 360.32 kHz, σ = 0.750S/m, tissue density = 1,000kg/m3 Document generated at 2025/11/20 09:30:42, simulation performed at 2025/11/20 08:59:04 using Sim4Life version 8.0.1.15737 Peak incident fields [rms] psSAR [mW/kg]H-field extent Warnings Dist. [mm] Hinc [A/m] Einc [V/m]1g avg.10g avg.-20 dB radius [mm] SignVector potential Boundary effect 0.001,36879.667.327.530.610%10%7% 1.001,27279.654.322.330.610%10%7% 2.001,17773.943.418.030.610%10%8% 3.001,08268.234.314.530.610%10%9% 4.0098762.427.011.630.710%10%10% 5.0089256.721.39.3730.710%10%12% 6.0079751.016.97.6430.810%10%14% 7.0070245.313.76.3130.910%10%15% 8.0060839.611.25.2431.210%10%15% 9.0054136.49.104.3631.510%10%15% 10.049734.57.503.6531.710%10%16% 11.045332.66.243.0932.010%10%17% 12.040930.75.242.6432.610%10%18% 13.036528.84.492.2933.310%10%20% 14.032126.93.902.0034.310%10%21% 15.027725.03.421.7635.810%10%22% 16.024323.63.001.5637.110%10%22% 17.022123.02.641.3837.810%10%23% 18.020422.32.331.2438.410%10%24% 19.018621.72.071.1139.110%10%25% 20.016921.11.851.0140.010%10%26% cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-1045-25-01-03_TR1-A201-R01 Page 5 of 10 Device under test •Info128 kHz CW Sample •Serial numberSample 2 •ScenarioMin. peak search frequency [kHz] 60 Max. peak search frequency [kHz] 180 Envelope smoothing window [-] 12000 Adaptive slice decay threshold [-] 0.99 Acquisition time [s] 0.2 Tool info •DASY software versionDASY8 Module WPT 2.8.0.5947 •Probe model, serial no. and configuration dateMAGPy-8H3D+E3Dv2, WP000009, 2025/11/11 •Software version2.8.9, backend: 2.2.36 Scan info •Center locationx:-60.00 μm, y:-30.00 μm, z:124.96 mm •Dimensionsx:168.7mm, y:168.6mm, z:81.0mm •Resolutionx:7.33 mm, y:7.33 mm, z:7.33 mm •Completed on2025/11/19 20:51:09 Measurement results •Maximum H-field [rms]magnitude:480.00 A/mx:71.19 A/m, y:97.52 A/m, z:464.56 A/m •Maximum H-field location relative to DUTx:-3.67 mm, y:-3.67 mm, z:8.50 mm •Maximum E-field [rms]magnitude:24.32 V/mx:20.88 V/m, y:11.43 V/m, z:4.96 V/m •Maximum E-field location relative to DUTx:0.00 m, y:14.67 mm, z:0.00 m •Distance to -20.0dB boundary29.33 mm •Offset relative to DUTx:0.00 m, y:0.00 m, z:1.00 mm 3.Result for Sample 2 - CW 128 kHz (2) cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-1045-25-01-03_TR1-A201-R01 Page 6 of 10 H-field magnitude [rms] at center locationH-field magnitude [rms] at lowest plane cetecom advanced GmbH Untertuerkheimer Str. 6-10, 66117 Saarbruecken Document No. 1-1045-25-01-03_TR1-A201-R01 Page 7 of 10 Incident fields and induced fields in the homogeous phantom at the peak frequency f = 127.96 kHz, σ = 0.750S/m, tissue density = 1,000kg/m3 Document generated at 2025/11/20 08:39:17, simulation performed at 2025/11/20 08:38:15 using Sim4Life version 8.0.1.15737 Peak incident fields [rms] psSAR [mW/kg]H-field extent Warnings Dist. [mm] Hinc [A/m] Einc [V/m]1g avg.10g avg.-20 dB radius [mm] SignVector potential Boundary effect 0.001,10524.36.022.4831.26%9%8% 1.001,03024.34.902.0331.26%9%8% 2.0095622.63.951.6531.26%9%9% 3.0088120.83.151.3431.26%9%10% 4.0080719.12.511.0831.26%9%11% 5.0073217.31.990.87931.26%9%13% 6.0065815.61.600.72131.36%9%15% 7.0058313.81.300.59731.56%9%16% 8.0050912.11.060.49531.86%9%16% 9.0045311.10.8620.41132.26%9%16% 10.041710.60.710.34232.56%9%17% 11.038010.00.5880.2932.96%9%19% 12.03449.510.4920.24933.56%9%20% 13.03078.970.4210.21634.26%9%22% 14.0…

Text truncated - open the document above for the full version.

Test Report

TEST REPORT Test report no.: 1-1447-25-01-03_TR1-R02 Testing laboratory Applicant cetecom advanced GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: https://cetecomadvanced.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2018-03) by the Deutsche Akkreditierungsstelle GmbH (DAkkS). The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12047-01-00. ISED Testing Laboratory Recognized Listing Number: DE0001 FCC designation number: DE0002 BURY GmbH Robert-Koch-Straße 1-7 32584 Löhne / Germany Phone: +49 5732-9706-0 Contact: -/- -/- e-mail: [email protected] Manufacturer BURY Sp. z o.o. ul. Wojska Polskiego 4 PL-39-300 Mielec / POLAND Test standard/s FCC - Title 47 CFR Part 15 FCC - Title 47 of the Code of Federal Regulations; Chapter I; Part 15 - Radio frequency devices RSS - 216 Issue 3 RSS-216 — Wireless Power Transfer Devices RSS - Gen Issue 5 incl. Amendment 1 & 2 Spectrum Management and Telecommunications Radio Standards Specification - General Requirements for Compliance of Radio Apparatus For further applied test standards please refer to section 3 of this test report. Test Item Kind of test item: Wireless charger with NCF card protection Model name: WLC MPP Single FCC ID: QZ9-WMS01 ISED certification number: 5927A-WMS01 Frequency: 126 kHz; 360 kHz Technology tested: WPT Antenna: Integrated antenna Power supply: 9.0 V to 16.0 V DC by car battery Temperature range: -40°C to +45°C This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report authorized: Test performed: Christoph Schneider Tobias Wittenmeier Lab Manager Testing Manager Radio Labs Radio Labs Test report no.: 1-1447-25-01-03_TR1-R02 © cetecom advanced GmbH Page 2 of 23 1 Table of contents 1 Table of contents .................................................................................................................................... 2 2 General information ................................................................................................................................ 3 2.1 Notes and disclaimer .................................................................................................................... 3 2.2 Application details ........................................................................................................................ 3 2.3 Test laboratories sub-contracted .................................................................................................. 3 3 Test standard/s, references and accreditations ....................................................................................... 4 4 Reporting statements of conformity – decision rule ................................................................................ 5 5 Test environment.................................................................................................................................... 6 6 Test item ................................................................................................................................................ 6 6.1 General description ...................................................................................................................... 6 6.2 Additional information .................................................................................................................. 6 7 Description of the test setup ................................................................................................................... 7 7.1 Shielded fully anechoic chamber .................................................................................................. 8 7.2 Conducted measurements normal and extreme conditions............................................................ 9 8 Sequence of testing .............................................................................................................................. 10 8.1 Sequence of testing radiated spurious 9 kHz to 30 MHz .............................................................. 10 9 Measurement uncertainty ..................................................................................................................... 11 10 Summary of measurement results ..................................................................................................... 12 11 Additional comments ........................................................................................................................ 12 12 Measurement results ........................................................................................................................ 13 12.1 Occupied bandwidth ................................................................................................................ 13 12.2 Frequency stability .................................................................................................................. 15 12.3 Field strength of the fundamental ............................................................................................ 16 12.4 Field strength of the harmonics and spurious .......................................................................... 18 13 Observations ..................................................................................................................................... 21 14 Glossary ............................................................................................................................................ 22 15 Document history .............................................................................................................................. 23 Test report no.: 1-1447-25-01…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Johann Dshus(Mr)
[email protected]Fax: +49 (0)1805 - 84 23

Technical Contact

Americas Compliance consulting, LLC dba iCertifiPaul Preston
[email protected]

Bend, Oregon · United States

Test Firm

cetecom advanced GmbHGerald Schmidt
[email protected]Fax: 49-681-598-8775

Technical Specifications

#Rule PartsFrequency RangePower Output
115C0.126 MHz - 0.126 MHz-
215C0.36 MHz - 0.36 MHz-
Confidentiality
Long Term
Grant Notes
The highest reported SAR for body-worn accessory and extremities SAR exposure conditions are 0.486 W/kg and 0.29 W/kg, respectively.

Other Applications from Bury GmbH & Co KG

QZ9-WMD01

Wireless charger with NFC card protection

Jul 22, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
QZ9-CC-26

Wireless charger with NFC card protection and digital key functionality

Mar 10, 2026

Equipment Class

DCD - Part 15 Low Power Transmitter Below 1705 kHz
QZ9-DCB

Dual Wireless charger with NFC card protection and digital key functionality

Jan 17, 2024

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
Base Station - FCC ID QZ9-CG3 - Bury GmbH & Co KG
QZ9-CG3

Base Station

May 09, 2023

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Storage box with wireless charger and USB charger - FCC ID QZ9-LADESTAUFACH - Bury GmbH & Co KG
QZ9-LADESTAUFACH

Storage box with wireless charger and USB charger

Dec 02, 2020

Equipment Class

8CC - Part 18 Consumer Device