Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Smoke Sensor PSG01 The Smoke Sensor PSG01 is designed to give early warning of developing fires by giving off the alarm sounds from its build-in alarm horn, based on Z-Wave TM technology. It is the Z-Wave TM plus product, it support the security, OTA... Those newest features of the Z-Wave TM technology. Z-Wave TM is a wireless communication protocol designed for home automation, specifically to remotely control applications in residential and light commercial environments. The technology uses a low-power RF radio embedded or retrofitted into home electronics devices and systems, such as lighting, home access control, entertainment systems and household appliances. This product can be included and operated in any Z-Wave TM network with other Z-Wave TM certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network. The device adopt the Z-Wave TM 500 series chip, when your Z-Wave TM network system is all made by Z-Wave TM 500 series devices. The network system will have the advantages as below. •Concurrent multi-channel support reduces external interference. •Better RF range, improve about 10 meters in indoor. •Support 100 Kbps transmit speed, speed up communication. Add to/Remove from Z-Wave TM Network There is one button on the device. It can be used to add, remove, reset or association from Z-Wave TM network. In the first time, add the device into the Z-Wave TM network. First, make sure the primary controller is in the add mode. And then insert battery to power on the device. Press the button once to start the NWI (Network Wide Inclusion) mode. And it should be added in 5 seconds. Notice: Including a node ID allocated by Z-Wave TM Controller means “Add” or “Inclusion”. Excluding a node ID allocated by Z-Wave TM Controller means “Remove” or “Exclusion”. Function Description Add 1.Have Z-Wave TM Controller entered inclusion mode. 2.Pressing button three times within 1.5 seconds to enter the inclusion mode. 3.After add successful, the device will wake to receive the setting command from Z-Wave TM Controller about 20 seconds. Remove 1.Have Z-Wave TM Controller entered exclusion mode. 2.Pressing button three times within 1.5 seconds to enter the exclusion mode. Node ID has been removed. 1 Reset Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable. 1.Pressing button four times within 1.5 seconds and do not release the button in the 4 th pressed, and the red LED will light ON. 2.After the red LED flash 9 times, release the button within 2 seconds. 3.IDs are removed and all settings will reset to factory default. Association 1.Have Z-Wave TM Controller entered association mode. 2.Pressing button three times within 1.5 seconds to enter the association mode. Note: The device support 1 groups. This group is for receiving the report message, like triggered event etc. This group support 8 nodes maximum. •Failed or success in add/remove the node ID can be viewed from Z-Wave TM Controller. Notice 1: Always RESET a Z-Wave TM device before trying to add it to a Z-Wave TM network Notice 2: When the device into NWI mode, the sensor functionality will useless. The NWI mode will timeout after 30 seconds. You can press the button 3 times to abort the NWI mode. Z-Wave TM Notification After the device adding to the network, it will wake-up once per day in default. When it wake-up it will broadcast the “Wake Up Notification” message to the network, and wake-up 10 seconds for receive the setting commands. The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours. And the interval step is 30 minutes. If the user want to wake-up the device immediately, please press the button once. The device will wake-up 10 seconds. Z-Wave TM Message Report When Smoke Sensor detects, the device will report the trigger event and also report the battery status. In default the device will using Notification Report to represent the trigger event, it can be changed to Sensor Binary Report by setting the configuration NO. 7 Bit4 to 1. * Smoke Detected/Test Report: When the Smoke Sensor detects smoke, the device will unsolicited to send the smoke detected (0x02) report to the nodes in the group 1. When the device is in alarm test mode, the device will unsolicited to send the Smoke Sensor test (0x03) report to the nodes in the group 1. Notification Report (V4) Notification Type: Smoke (0x01) Event: Smoke detected, Unknown Location (0x02) Smoke Alarm Test (0x03) Sensor Binary Report (V2) Sensor Type: Smoke (0x02) Sensor Value: 0xFF 2 * Tamper Report: When the tamper is pressed, the device will into the alarm state. In that state, if tamper is released, the yellow LED will light on and the device will unsolicited to send the report to the nodes in the group 1. Notification Report (V4) Notification Type: Home Security (0x07) Event: Tampering. Product covering removed (0x03) Sensor Binary Report (V2) Sensor Type: Tamper (0x08) Sensor Value: 0xFF Notice : When the event triggered, the device will report the messages to the nodes in the group 1. The messages also include the tamper status. Power Up Procedure * NWI When the device power on, the device will check is it already adding to the network? If doesn't, press the button to start the NWI mode. Until timeout or the device successful to inclusion by controller. NWI mode can be aborted by pressing the button 3 times. * Wake When the device power on, the device will wake about 20 seconds. In this duration, the controller can communicate with the device. Normally the device is always sleeping to save the battery energy. Over The Air (OTA) Firmware Update The device support the Z-Wave firmware update via OTA. Let the controller into the firmware update mode, and then press the button once to start the update. Please don't remove the battery, otherwise it will cause the firmware bro…
Text truncated - open the document above for the full version.
Page 1 CONSTRUCTION PHOTOS OF EUT
Page 2 Page 3 Page 4 Page 5 Page 6
FCC ID: RHHPSG01 Report No.: RF150109C17 OPERATIONAL DESCRIPTION The transmitter of the EUT (Z-Wave Smoke Sensor) is powered from 3Vdc battery. The antenna is Monopole antenna without antenna connector. For more detailed instruction, please take a look at the user’s manual.
Report No.: RF150109C17 1 of 21 Report Format Version 5.0.0 FCC TEST REPORT REPORT NO.: RF150109C17 MODEL NO.: PSG01-2 FCC ID: RHHPSG01 RECEIVED: Jan. 09, 2015 TESTED: Jan. 14, 2015 ISSUED: Jan. 22, 2015 APPLICANT: Philio Technology Corporation ADDRESS: 8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257, Taiwan (R.O.C) ISSUED BY: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch LAB ADDRESS: No. 47-2, 14th Ling, Chia Pau Vil., Lin Kou Dist., New Taipei City, Taiwan, R.O.C. TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C. This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the com pliance or non-compliance to the specification. This report should not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies. Report No.: RF150109C17 2 of 21 Report Format Version 5.0.0 Table of Contents RELEASE CONTROL RECORD .............................................................................................................. 3 1. CERTIFICATION ......................................................................................................................... 4 2. SUMMARY OF TEST RESULTS ................................................................................................. 5 2.1 MEASUREMENT UNCERTAINTY .............................................................................................. 5 3. GENERAL INFORMATION ......................................................................................................... 6 3.1 GENERAL DESCRIPTION OF EUT ............................................................................................ 6 3.2 DESCRIPTION OF TEST MODES .............................................................................................. 6 3.2.1 TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL ............................................. 7 3.3 DESCRIPTION OF SUPPORT UNITS ........................................................................................ 8 3.3.1 CONFIGURATION OF SYSTEM UNDER TEST ......................................................................... 8 3.4 GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................................. 8 4. TEST TYPES AND RESULTS ..................................................................................................... 9 4.1 RADIATED EMISSION AND BAND EDGE MEASUREMENT .................................................... 9 4.1.1 LIMITS OF RADIATED EMISSION AND BAND EDGE MEASUREMENT ................................. 9 4.1.2 TEST INSTRUMENTS .............................................................................................................. 10 4.1.3 TEST PROCEDURES ............................................................................................................... 11 4.1.4 DEVIATION FROM TEST STANDARD ..................................................................................... 11 4.1.5 TEST SETUP ............................................................................................................................ 12 4.1.6 EUT OPERATING CONDITIONS .............................................................................................. 12 4.1.7 TEST RESULTS ........................................................................................................................ 13 5. PHOTOGRAPHS OF THE TEST CONFIGURATION ............................................................... 19 6. INFORMATION ON THE TESTING LABORATORIES .............................................................. 20 7. APPENDIX A – MODIFICATION RECORDERS FOR ENGINEERING CHANGES TO THE EUT BY THE LAB ...................................................................................................................... 21 Report No.: RF150109C17 3 of 21 Report Format Version 5.0.0 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED RF150109C17 Original release. Jan. 22, 2015 Report No.: RF150109C17 4 of 21 Report Format Version 5.0.0 1. CERTIFICATION PRODUCT: Z-Wave Smoke Sensor MODEL NO.: PSG01-2 BRAND: APPLICANT: Philio Technology Corporation TESTED: Jan. 14, 2015 TEST SAMPLE: ENGINEERING SAMPLE STANDARDS: FCC Part 15, Subpart C (Section 15.249) ANSI C63.10-2009 The above equipment (model: PSG01-2) has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC characteristics under the conditions specified in this report. PREPARED BY : , DATE : Jan. 22, 2015 Suntee Liu / Specialist APPROVED BY : …
Text truncated - open the document above for the full version.
1 PHOTOGRAPHS OF THE TEST CONFIGURATION RADIATED EMISSION TEST
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 908.4 MHz - 916 MHz | - |

Smart Energy In Wall Meter
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Smart energy plug in switch
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Smart Color Button
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Flood Multi Sensor
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
In Wall Dual relay(2 way) switch module
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter