
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Wireless Pool Thermometer S300PT-US Operating Manual ELV Electronics Ltd. Hong Kong Please read these instructions carefully from start to finish before initial start-up to avoid functional breakdown and faulty operation. The manual contains much important information about the installation and operation. Keep the manual available for future reference. If you sell or give away this unit to other persons, hand over also this manual. 1 st English edition March 2006 Documentation © 2006 ELV ltd. Hongkong All rights reserved. This handbook must not be reproduced in any form, even in ex- cerpts, or duplicated or processed using electronic, mechanical or chemical proce- dures without written permission of the publisher. This handbook may contain mistakes and printing errors. The information in this handbook is regularly checked and corrections made in the next issue. We accept no liability for technical mistakes or printing errors, or their consequences. All trademarks and patents are acknowledged. Printed in Hong Kong Modifications due to technical improvements may be made without warning. 66255 Y2006V1.0 Content 1. General information and function ................................................4 2. Indended usage ...........................................................................4 3. Safety instructions .......................................................................5 4. Battery and environment instructions ..........................................5 5. Preparing for operation ................................................................ 6 5.1. Open the housing ........................................................................ 6 5.2. Inserting batteries ........................................................................6 5.3. Setting address and measuring unit ............................................ 7 6. Operation ..................................................................................... 8 7. Range ..........................................................................................8 8. Maintenance ................................................................................ 9 8.1. Changing the batteries ................................................................9 8.2. Cleaning .......................................................................................9 9. Disposal ....................................................................................... 9 9.1. General ........................................................................................9 9.2. Disposing of used batteries .........................................................9 10. Technical Data ...........................................................................10 11. FCC Information ........................................................................ 11 1. General information and function This wireless, battery-operated pool thermometer is a high quality measu- ring system to define the temperatur of water in swimming pools, garden pools, bowls etc. It is water-proof and can swim. The thermometer indued with own temperature display. This can show the temperature in centigrade ( ̊C) or degrees Fahrenheit ( ̊F). The thermometer indued with a transmitter for send the temperatur data to the wireless poolthermometer basic station PTD300-US. Also it is possible to receive the data with many weather stations from ELV. The following weather stations are compatible to this wireless thermometer: ⌦- BA 1010-US ⌦- WS 200-US ⌦- WS 300-US ⌦- WS 250 Edition-US ⌦ This weather stations can receive the data as a normal outdoor sensor. For this using the pool thermometer is addressable accordingly to the ELV adress system. Please refer to the manual of the weather station. 2. Indended usage The product is intended for domestic use. It is not suitable for medical purposes or public information. This product is designed for show the water temperatur in pools, bowls etc. It is only designed to using into water, not other liquids! The product is battery-operated. It transmits his data per radio to a ELV base station (see below, 433 MHz, range up to 300 ft. in open space). Any other use than that described above may go to damage the product or to other danger. The product has been EMV-tested and meets the requirements of the valid international guidelines. CE-conformity has been proven and the corresponding declarations deposited with the manufacturer. 3. Safety Instructions We shall not assume any liability for damage to items or persons caused by improper handling or non-observance of the safety instructions! In such cases, any guarantee claims shall become null and void. - Do not use this product in hospitals or medical institutions. Although the outdoor sensor only emits relatively weak radio signals, these may cause interference to life-support systems. The same can also apply in other areas. - Do not use the unit, if there are damages on the housing. - Do not subject the device to temperatures below 32 ̊F (0°C) or above 158 ̊F (70°C). - Caution by danger of freezing! Take the unit out of the water, if the temperature goes to 32 ̊F (0 ̊C). - For safety and licensing reasons (CE), it is not permitted to convert or modify the product. - Do not leave the packaging material laying around. Plastic foil and bags, polystyrene parts etc. are dangerous toys in the hands of child- ren. - This product is not a toy. It contains glass and small parts, children can swallow up them. Erect the unit out of the reach of children. - This product is not a toy for pets. It contains peaked and dangerous materials, they can harm pets, if they bite to the unit. • Batteries do not belong in the hands of children. • Observe the right polarity when inserting the batteries. • Do not leave batteries laying around. Pets or small children may swallow them. If they are swallowed, contact a doctor immediately. • Leaking or damaged batteries may lead to injury to the skin. For this r…
Text truncated - open the document above for the full version.
ELV Electronics Ltd., Hong Kong 06. Juni 2006 Filename: elv_s300pt-us_extpho.doc Page : 1 / 2 External Photos Wireless Pool Thermometer ELV S300PT-US ELV Electronics Ltd., Hong Kong 06. Juni 2006 Filename: elv_s300pt-us_extpho.doc Page : 2 / 2
ELV Electronics Ltd., Hong Kong 06. Juni 2006 Filename: elv_s300pt-us_labelloc.doc Page : 1 / 3 FCC ID Label Location Information Wireless Pool Thermometer ELV S300PT-US ELV Electronics Ltd., Hong Kong 06. Juni 2006 Filename: elv_s300pt-us_labelloc.doc Page : 2 / 3 ELV Electronics Ltd., Hong Kong 06. Juni 2006 Filename: elv_s300pt-us_labelloc.doc Page : 3 / 3
ELV Electronics Ltd., Hong Kong 06. Juni 2006 Filename: elv_s300pt-us_intpho.doc Page : 1 / 2 Internal Photos Wireless Pool Thermometer ELV S300PT-US ELV Electronics Ltd., Hong Kong 06. Juni 2006 Filename: elv_s300pt-us_intpho.doc Page : 2 / 2
ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH TEST - REPORT FCC RULES PART 15 / SUBPART C Test report no.: G0M20605-0503-C-1 FCC ID: RNT-KS300US Certificate 1983-01 ELECTRONIC TECHNOLOGY SYSTEMS STORKOWER STRASSE 38C, D-15526 REICHENWALDE B. BERLIN DR. GENZ GMBH PHONE +49-33631-888 00 FAX +49-33631-888 660 ETS Dr. Genz GmbH, Germany Registration number: G0M20605-0503-C-1 Page 1 of 25 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH TABLE OF CONTENTS 1 General information 1.1 Notes 1.2 Testing laboratory 1.3 Details of approval holder 1.4 Application details 1.5 Test item 1.6 Test standards 2 Technical test 2.1 Summary of test results 2.2 Test environment 2.3 Test equipment utilized 2.4 Test Procedure 3 Test Results 3.1 Output power 3.2 Out of band radiated emission 3.3 Transmitter radiated emissions in restricted bands 3.4 Spurious emissions radiated, transmitter 3.5 20 dB bandwidth 3.6 Automatical deactivation ETS Dr. Genz GmbH, Germany Registration number: G0M20605-0503-C-1 Page 2 of 25 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Futhermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample posseses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. The test results of this test report relate exclusively to the item tested as specified in 1.5. The test report may only be reproduced or published in full. Reproduction or publication of extractes from the report requires the prior written approval of the ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH. Tester: 27.06.2006 J. Marquardt Date ETS-Lab. Name Signature Technical responsibility for area of testing: 27.06.2006 N. Kaspar Date ETS Name Signature ETS Dr. Genz GmbH, Germany Registration number: G0M20605-0503-C-1 Page 3 of 25 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.2 Testing laboratory 1.2.1 Location ELECTRONIC TECHNOLOGY SYSTEM DR. GENZ GMBH (ETS) Storkower Straße 38c D-15526 Reichenwalde b. Berlin Germany Telefon : +49 33631 888 00 Telefax : +49 33631 888 660 1.2.2 Details of accreditation status ACCREDITED TESTING LABORATORY DAR-REGISTRATION NUMBER: DAT-P-201/96 A CCREDITED COMPETENT BODY DAR-REGISTRATION NUMBER: BPT-ZE-026/96-00 FCC FILED TEST LABORATORY REG. NO. 96970 A2LA Accredited Certification No.1983-01 BLUETOOTH QUALIFICATION TEST FACILITY (BQTF) Accredited by Bluetooth Qualification Review Board I NDUSTRY CANADA FILED TEST LABORATORY REG. NO. IC 3470 1.3 Details of approval holder Name : ELV Electronics Limited Street : 16/F Kailey Industrial Centre No. 12, Fung Yip Street Town : Chaiwan Country : Hong Kong Telephone : +852 2367 0322 Fax : +852 2367 0822 Contact : Shirley Hui Lai Chu E-mail : [email protected] ETS Dr. Genz GmbH, Germany Registration number: G0M20605-0503-C-1 Page 4 of 25 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.4 Application details Date of receipt of application : 23.05.2006 Date of receipt of test item : 23.05.2006 Date of test : 12.06.2006 1.5 Test item Description of test item : Wireless Pool Thermometer - (Transmitter) Type identification : S300PT-US Brand Name: ELV Serial number : Test sample without serial number Transmitting frequency : 433.05 MHz - 434.79 MHz Operation mode : simplex Transmitting mode : K1D-300K Voltage supply : 4.5 V DC (battery) (3 x 1.5 V DC) Antenna : Internal antenna Photos : see Annex Manufacturer: (if applicable) Name : DJY Electronics Co. Ltd. Street : 518101 3/F Fu Yuan #3 Industrial Building, 45th Area of Bao An District Town : Shen Zhen Country : P.R.C. Additional information : none ETS Dr. Genz GmbH, Germany Registration number: G0M20605-0503-C-1 Page 5 of 25 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.6 Test standards Technical standard : FCC RULES PART 15 / SUBPART B §15.109 / SUBPART C § 15.203, §15.231 2 Technical test 2.1 Summary of test results No deviations from the technical specification(s) were ascertained in the course : of the tests performed. or The deviations as specified in 2.5 were ascertained in the course of the tests performed. 2.2 Test environment Temperature : 23 ° C Relative humidity content : 20 ... 75 % Air pressure : 86 ... 103 kPa Details of power supply : 4.5 V DC (battery) (3 x 1.5 V DC) ETS Dr. Genz GmbH, Germany Registration number: G0M20605-0503-C-1 Page 6 of 25 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 2.3 Test equipment utilized No. Test equipment Type Manufacturer ETS 0001 ESD Gun SESD 30000 Schlöder ETS 0002 Test receiver ESVP Rohde & Schwarz ETS 0003 Diode power sensor NRV-Z2 Rohde & Schwarz ETS 0004 Spectrum and network analyzer FSMS 26 Rohde & Schwarz ETS 0005 Test receiver SMV 11 MEB ETS 0006 Test receiver system SME 12 MEB ETS 0007 Horn antenna AT 4004 ar ETS 0008 Antenna Loop antenna Siemens ETS 0009 Antenna ARA 2 MEB ETS 0010 Antenna Loop antenna MEB ETS 0011 Antenna van Veen/ Frame Rohde & Schwarz ETS 0012 Antenna HK 116 Rohde & Schwarz ETS 0013 Antenna HL 223 Rohde & Schwarz ETS 0014 Antenna HL 025 Rohde & Schwarz ETS 0015 Antenna HL 025 Rohde & Schwarz ETS 0016 Precision antenna kit VHAP Schwarzbeck ETS 0017 Precision antenna kit UHAP Schwarzbeck ETS 0018 Horn antenna BBHA 9120 D Schwarzbeck ETS 0019 Horn antenna BBHA 9120 D Schwarzbeck ETS 0020 Antenna DP 21 MEB ETS 0021 Antenna DP 3 MEB ETS 0022 Antenna SAS-200/ 521 A.H. Systeme+D65 ETS 0023 Antenna DP 1 MEB ETS 0024 Antenna mast AF 2 MEB ETS 0025 Antenna mast AF 2 MEB ETS 0026 Tripod Heinrich Deisel ETS 0027 Tripod Heinrich D…
Text truncated - open the document above for the full version.
ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH TEST - REPORT FCC RULES PART 15 / SUBPART C Test report no.: G0M20605-0503-C-1 FCC ID: RNT-PT3 Certificate 1983-01 ELECTRONIC TECHNOLOGY SYSTEMS STORKOWER STRASSE 38C, D-15526 REICHENWALDE B. BERLIN DR. GENZ GMBH PHONE +49-33631-888 00 FAX +49-33631-888 660 ETS Dr. Genz GmbH, Germany Registration number: G0M20605-0503-C-1 Page 1 of 25 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH TABLE OF CONTENTS 1 General information 1.1 Notes 1.2 Testing laboratory 1.3 Details of approval holder 1.4 Application details 1.5 Test item 1.6 Test standards 2 Technical test 2.1 Summary of test results 2.2 Test environment 2.3 Test equipment utilized 2.4 Test Procedure 3 Test Results 3.1 Output power 3.2 Out of band radiated emission 3.3 Transmitter radiated emissions in restricted bands 3.4 Spurious emissions radiated, transmitter 3.5 20 dB bandwidth 3.6 Automatical deactivation ETS Dr. Genz GmbH, Germany Registration number: G0M20605-0503-C-1 Page 2 of 25 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Futhermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification. Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample posseses the qualities as maintained and that is performance generally conforms to representative cases of communications equipment. The test results of this test report relate exclusively to the item tested as specified in 1.5. The test report may only be reproduced or published in full. Reproduction or publication of extractes from the report requires the prior written approval of the ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH. Tester: 27.06.2006 J. Marquardt Date ETS-Lab. Name Signature Technical responsibility for area of testing: 27.06.2006 N. Kaspar Date ETS Name Signature ETS Dr. Genz GmbH, Germany Registration number: G0M20605-0503-C-1 Page 3 of 25 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.2 Testing laboratory 1.2.1 Location ELECTRONIC TECHNOLOGY SYSTEM DR. GENZ GMBH (ETS) Storkower Straße 38c D-15526 Reichenwalde b. Berlin Germany Telefon : +49 33631 888 00 Telefax : +49 33631 888 660 1.2.2 Details of accreditation status ACCREDITED TESTING LABORATORY DAR-REGISTRATION NUMBER: DAT-P-201/96 A CCREDITED COMPETENT BODY DAR-REGISTRATION NUMBER: BPT-ZE-026/96-00 FCC FILED TEST LABORATORY REG. NO. 96970 A2LA Accredited Certification No.1983-01 BLUETOOTH QUALIFICATION TEST FACILITY (BQTF) Accredited by Bluetooth Qualification Review Board I NDUSTRY CANADA FILED TEST LABORATORY REG. NO. IC 3470 1.3 Details of approval holder Name : ELV Electronics Limited Street : 16/F Kailey Industrial Centre No. 12, Fung Yip Street Town : Chaiwan Country : Hong Kong Telephone : +852 2367 0322 Fax : +852 2367 0822 Contact : Shirley Hui Lai Chu E-mail : [email protected] ETS Dr. Genz GmbH, Germany Registration number: G0M20605-0503-C-1 Page 4 of 25 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.4 Application details Date of receipt of application : 23.05.2006 Date of receipt of test item : 23.05.2006 Date of test : 12.06.2006 1.5 Test item Description of test item : Wireless Pool Thermometer - (Transmitter) Type identification : S300PT-US Brand Name: ELV Serial number : Test sample without serial number Transmitting frequency : 433.05 MHz - 434.79 MHz Operation mode : simplex Transmitting mode : K1D-300K Voltage supply : 4.5 V DC (battery) (3 x 1.5 V DC) Antenna : Internal antenna Photos : see Annex Manufacturer: (if applicable) Name : DJY Electronics Co. Ltd. Street : 518101 3/F Fu Yuan #3 Industrial Building, 45th Area of Bao An District Town : Shen Zhen Country : P.R.C. Additional information : none ETS Dr. Genz GmbH, Germany Registration number: G0M20605-0503-C-1 Page 5 of 25 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.6 Test standards Technical standard : FCC RULES PART 15 / SUBPART B §15.109 / SUBPART C § 15.203, §15.231 2 Technical test 2.1 Summary of test results No deviations from the technical specification(s) were ascertained in the course : of the tests performed. or The deviations as specified in 2.5 were ascertained in the course of the tests performed. 2.2 Test environment Temperature : 23 ° C Relative humidity content : 20 ... 75 % Air pressure : 86 ... 103 kPa Details of power supply : 4.5 V DC (battery) (3 x 1.5 V DC) ETS Dr. Genz GmbH, Germany Registration number: G0M20605-0503-C-1 Page 6 of 25 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 2.3 Test equipment utilized No. Test equipment Type Manufacturer ETS 0001 ESD Gun SESD 30000 Schlöder ETS 0002 Test receiver ESVP Rohde & Schwarz ETS 0003 Diode power sensor NRV-Z2 Rohde & Schwarz ETS 0004 Spectrum and network analyzer FSMS 26 Rohde & Schwarz ETS 0005 Test receiver SMV 11 MEB ETS 0006 Test receiver system SME 12 MEB ETS 0007 Horn antenna AT 4004 ar ETS 0008 Antenna Loop antenna Siemens ETS 0009 Antenna ARA 2 MEB ETS 0010 Antenna Loop antenna MEB ETS 0011 Antenna van Veen/ Frame Rohde & Schwarz ETS 0012 Antenna HK 116 Rohde & Schwarz ETS 0013 Antenna HL 223 Rohde & Schwarz ETS 0014 Antenna HL 025 Rohde & Schwarz ETS 0015 Antenna HL 025 Rohde & Schwarz ETS 0016 Precision antenna kit VHAP Schwarzbeck ETS 0017 Precision antenna kit UHAP Schwarzbeck ETS 0018 Horn antenna BBHA 9120 D Schwarzbeck ETS 0019 Horn antenna BBHA 9120 D Schwarzbeck ETS 0020 Antenna DP 21 MEB ETS 0021 Antenna DP 3 MEB ETS 0022 Antenna SAS-200/ 521 A.H. Systeme+D65 ETS 0023 Antenna DP 1 MEB ETS 0024 Antenna mast AF 2 MEB ETS 0025 Antenna mast AF 2 MEB ETS 0026 Tripod Heinrich Deisel ETS 0027 Tripod Heinrich Deise…
Text truncated - open the document above for the full version.
ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20605-0503-C-1 Page 9 of 11 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20605-0503-C-1 Page 10 of 11 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH ETS Dr. Genz GmbH, Germany Registration number: G0M20605-0503-C-1 Page 11 of 11
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 433.05 MHz - 434.79 MHz | - |

Wireless Weather Station
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Wireless Weather Station
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
RF Tranceiver Module
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Wireless Weather Station
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Wireless Weather Station
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter