Operating Instructions Weather station βWS 200USβ ELV Electronics Ltd. Β· Hongkong These operating instructions belong with this product. They contain important information for putting it into service and operating it. This should be noted also when this product is passed on to a third party. Therefore look after these operating instructions for future reference! A list of contents with the corresponding page numbers can be found in the index on page 4. 1 st English edition May 006 Documentation Β© 006 ELV Electronics Limited All rights reserved. This handbook must not be reproduced in any form, even in excerpts, or duplicated or processed using electronic, mechanical or chemical procedures without written permission of the publisher. This handbook may contain mistakes and printing errors. The information in this handbook is regularly checked and corrections made in the next issue. We accept no liability for technical mistakes or printing errors, or their consequences. All trademarks and patents are acknowledged. Printed in Hong Kong Modifications due to technical improvements may be made without prior notification. 00066548 Y006 V1.0 Introduction Dear Customer, Thank you for purchasing this product. The product has been EMC-tested and thus meets the requirements of the valid national guidelines. See also FCC Information. In order to maintain this condition and ensure safe operation, you, as the user, have to observe this operating manual. Prior to using the product for the first time, please read the entire operating manual and observe all operating and safety instructions. We should already like to point out now the correct order for commissioning the products. Please also observe the installation and calibration instructions in this operating manual as well as the information about impairment of radio transmission between the sensors and base station. All company names and product descriptions listed herein are the trademarks of the re- spective manufacturers. All rights are reserved. F 4 Table of Contents Page 1. Intended Use ....................................................................................................................6 2. Scope of Delivery .............................................................................................................6 3. Explanation of Symbols...................................................................................................7 4. Features and Functions...................................................................................................7 a) Base Station ................................................................................................................. 7 b) Multipurpose Sensor .................................................................................................... 9 c) Outdoor Sensor ...........................................................................................................9 5. Safety Instructions ...........................................................................................................9 6. Battery and Accumulator Information .........................................................................10 7. Preparation and Start-up ..............................................................................................11 a) Start-up of the Multipurpose Sensor ......................................................................... 11 b) Start-up of Other Sensors .......................................................................................... 14 c) Start-up of the Base Station ......................................................................................14 d) Registration of Sensors during Operation ................................................................. 15 8. Indications of the LC Display ........................................................................................ 16 9. Configuration and Operation ........................................................................................18 a) Basic Settings, Configuration ....................................................................................18 Calling-up the configuration mode ............................................................................19 Setting the date and time ..........................................................................................19 Entering degrees of latitude and longitude ................................................................0 Setting the time zone .................................................................................................1 Assigning the march indication ..................................................................................1 Selecting the unit for the temperature indication ....................................................... Selecting the unit for the wind speed ........................................................................ Exiting the configuration mode .................................................................................. b) Operation .................................................................................................................. Selecting the indoor temperature .............................................................................. Selecting the outdoor temperature ............................................................................ Selecting the outdoor sensor ..................................................................................... Indicating the MIN/MAX values.................................................................................. Indicating the time/date for the single extreme value ................................................4 Deleting the MIN/MAX values ....................................................................................5 Setting the contrast of the LC display ..............................................................β¦
Text truncated - open the document above for the full version.
Page : 1 / 1 ELV Electronics Limited 16 th Floor, Kailey Ind. Centre, No. 12, Fung Yip Street, Chaiwan, Hong Kong Request for FCC Certification Wireless Weather Station ELV WS 200US FCC ID: RNT-WS200US May 18, 2006 Dear Sir or Madam, ELV Electronics Limited, Hong Kong hereby requests the FCC certification of the following device: Wireless Weather Station ELV WS 200US Attached please find: 1) 731 form 2) FCC ID label sample 3) FCC ID label location information 4) External Photos 5) Internal photos 6) Operational description 7) Block diagrams 8) Schematics 9) Test Report 10) Users manual 11) Parts List 12) RF Exposure Information 13) Confidentiality Request Letter 14) Antenna Specification
ELV Electronics Ltd., Hong Kong 24. Mai 2006 Datei: elv_ws200us_extpho.doc Seite : 1 / 2 External Photos Wireless Weather Station ELV WS 200US ELV Electronics Ltd., Hong Kong 24. Mai 2006 Datei: elv_ws200us_extpho.doc Seite : 2 / 2
ELV Electronics Ltd., Hong Kong 24. Mai 2006 Datei: elv_ws200us_labelloc.doc Seite : 1 / 2 FCC ID Label Location Information Wireless Weather Station ELV WS 200US ELV Electronics Ltd., Hong Kong 24. Mai 2006 Datei: elv_ws200us_labelloc.doc Seite : 2 / 2
ELV Electronics Ltd., Hong Kong 24. Mai 2006 Datei: elv_ws200us_intpho.doc Seite : 1 / 2 Internal Photos Wireless Weather Station ELV WS 200US ELV Electronics Ltd., Hong Kong 24. Mai 2006 Datei: elv_ws200us_intpho.doc Seite : 2 / 2
ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH FCC - TEST - REPORT FCC RULES PART 15 / SUBPART B Test report no.: G0M20603-0318-C-1 FCC ID: RNT-WS200US Certificate 1983-01 ELECTRONIC TECHNOLOGY SYSTEMS STORKOWER STRASSE 38C, D-15526 REICHENWALDE B. BERLIN DR. GENZ GMBH PHONE +49-33631-888 00 FAX +49-33631-888 660 Registration number: G0M20603-0318-C-1 ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH STORKOWER STRASSE 38C D-15526 REICHENWALDE B. BERLIN Page 1 of 24 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH TABLE OF CONTENTS 1 General Information 2 1.1 Notes 2 1.2 Tester 3 1.3 Testing laboratory 4 1.3.1 Location 4 1.3.2 Details of accreditation status 4 1.3.3 Test location, where different from ETS 4 1.4 Details of applicant 5 1.5 Application details 5 1.6 Test item 5 1.6.1 Description of test item 5 1.6.2 Manufacturer (if different from applicant in point 1.4) 6 1.6.3 Frequency behaviour 6 1.7 Test standards 6 2 Technical test 7 2.1 Summary of test results 7 2.2 Test environment 7 2.3 Test equipment utilized 8 2.4 Test results 18 2.4.1 Conducted Emission 19 2.4.2 Spurious Emission 20 2.5 Equipment Modification 21 2.6 Test protocols 22 3 Normative references 24 Annex: Pictures and diagrams Registration number: G0M20603-0318-C-1 ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH STORKOWER STRASSE 38C D-15526 REICHENWALDE B. BERLIN Page 2 of 24 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1 General Information 1.1 Notes The purpose of conformity testing is to increase the probability of adherence to the essential requirements or conformity specifications, as appropriate. The tests were carried out and passed in accordance to the standards: FCC part 15 : January 2005 The complexity of the technical specifications, however, means that full and thorough testing is impractical for both technical and economic reasons. Furthermore, there is no guarantee that a test sample which has passed all the relevant tests conforms to a specification (only telecommunication products). Neither is there any guarantee that such a test sample will interwork with other genuinely open systems. The existence of the tests nevertheless provides the confidence that the test sample possesses the qualities as maintained and that its performance generally conforms to representative cases of communications equipment. The test results of this test report relate exclusively to the item tested as specified in 1.6. The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH. Registration number: G0M20603-0318-C-1 ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH STORKOWER STRASSE 38C D-15526 REICHENWALDE B. BERLIN Page 3 of 24 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.2 Tester 01.06.2006 K. Damm ___________________________________________________________________ Date ETS-Lab. Test Engineer Signature Technical responsibility for area of testing: 01.06.2006 N. Kaspar ____________________________________________________________________ Date ETS Name Signature Registration number: G0M20603-0318-C-1 ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH STORKOWER STRASSE 38C D-15526 REICHENWALDE B. BERLIN Page 4 of 24 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.3 Testing laboratory 1.3.1 Location ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH (ETS) Storkower Strasse 38c D- 15526 Reichenwalde Germany Telephone : + 49 33631 888 00 Telefax : + 49 33631 888 660 1.3.2 Details of accreditation status ACCREDITED TESTING LABORATORY DAR-REGISTRATION NUMBER: TTI-P-G 126/96 A CCREDITED COMPETENT BODY DAR-REGISTRATION NUMBER: BPT-ZE-026/96 FCC filed test laboratory Reg. No. 96970 Bluetooth Qualification Test Facility (BQTF) Accredited by Bluetooth Qualification Review Board Industry Canada filed test laboratory Reg. No. IC 3470 A2LA Accredited Certification number 1983-01 1.3.3 Test location, where different from ETS Name: ./. Street: ./. Town: ./. Country: ./. Telephone: ./. Fax: ./. Teletex: ./. Registration number: G0M20603-0318-C-1 ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH STORKOWER STRASSE 38C D-15526 REICHENWALDE B. BERLIN Page 5 of 24 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.4 Details of applicant Name : ELV Elektronik AG Street : Maiburger Str. 32 - 36 Town : 26789 Leer Country : Deutschland Telephone : 0491- 6008217 Fax : 0491 7 20 30 Teletex : ./. Contact : Herr Dipl-Ing. (FH) Gerd Busboom Telephone : 0491- 6008217 1.5 Application details Date of receipt of application : 18.03.2006 Date of receipt of test item : 18.03.2006 Date of test : 23.03.2006 1.6 Test item 1.6.1 Description of test item Type of product : Wireless Weather Station - Indoor Unit - (Receiver) Type identification : WS200US Serial number : without Photos : Please find in Appendix. Registration number: G0M20603-0318-C-1 ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH STORKOWER STRASSE 38C D-15526 REICHENWALDE B. BERLIN Page 6 of 24 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 1.6.2 Manufacturer (if different from applicant in point 1.4) Name: DJY Electronics Co. Ltd. Street: 518101 3/F Fu Yuan #3 Industrial Building, 45th Area of Bao An District Town: Shen Zhen Country: P.R.C. 1.6.3 Frequency behavior Highest clock Frequency < 200 MHZ 1.7 Test standards FCC part 15 : January 2005 Registration number: G0M20603-0318-C-1 ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH STORKOWER STRASSE 38C D-15526 REICHENWALDE B. BERLIN Page 7 of 24 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH 2 Technical test 2.1 Summary of test results No deviations from the technical specification(s) were ascertained in the course : of the tests performed. or The deviations as specified in 2.4 were ascertained in the course of the tests Β performed. 2.2 Test environment Temperature : 18 ... 25 Β° C Relative humidity content : 20 ... 75 % Air pressure : 860 ... 1030 hPa Details of power supply : 4.5 V DC (battery) (3 x 1.5 V DC) Other parameters: Registration number: G0M20603-0318-C-1 ELECTRONIC TECβ¦
Text truncated - open the document above for the full version.
ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH Registration number: G0M20603-0318-C-1 ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH STORKOWER STRASSE 38C D-15526 REICHENWALDE B. BERLIN Page 10 of 11 ELECTRONIC TECHNOLOGY SYSTEMS DR.GENZ GMBH Registration number: G0M20603-0318-C-1 ELECTRONIC TECHNOLOGY SYSTEMS DR. GENZ GMBH STORKOWER STRASSE 38C D-15526 REICHENWALDE B. BERLIN Page 11 of 11
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15B | 433.05 MHz - 434.79 MHz | - |

Wireless Weather Station
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
Wireless Weather Station
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter
RF Tranceiver Module
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified
Wireless Pool Thermometer
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Wireless Weather Station
Equipment Class
CYY - Communications Receiver used w/Pt 15 Transmitter