Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Industrial PC MiniStation 12 User’s Manual Version 1.0 February , 2004 ii Copyright All rights reserved. The information contained herein is proprietary and is provided solely for the purpose of allowing customers to operate and/or service SAMMI INFORMATION SYSTEM CO.,LTD. manufactured equipment and is not to be released, reproduced, or used for any other purpose without the written permission of SAMMI INFORMATION SYSTEM CO.,LTD. Throughout this manual, trademarked names might be used. Rather than put a trademark ( TM ) symbol in every occurrence of a trademarked name, we state herein that we are using the names only in an editorial fashion, and to the benefit of the trademark owner, with no intention of infringement. Warranty Information SAMMI INFORMATION SYSTEM CO.,LTD. warrants products manufactured by it to be free of defects in material or workmanship under normal use and service for a period of one year from date of shipment. This warranty is specifically limited to the replacement or repair of any such warrantable defects, without charge, when the complete product is returned to SAMMI INFORMATION SYSTEM CO.,LTD. freight prepaid. Contact the factory ( or its distributors ) for a Return Material Authorization (RMA) number before returning the product. SAMMI INFORMATION SYSTEM CO.,LTD. shall be the sole judge of the warrantability of alleged product defects. Products that are returned for warranty examination and that are found to be non-warrantable are chargeable and are returned freight collect. Upon request, an estimate will be provided before any chargeable repairs are attempted. Warrantable products are repaired or replaced at no charge. SAMMI INFORMATION SYSTEM CO.,LTD. SHALL NOT BE LIABLE FOR WARRANTY IN ANY AMOUNT EXCEEDING THE PURCHASE PRICE OF THE GOODS. SAMMI INFORMATION SYSTEM CO.,LTD. SHALL NOT BE LIABLE FOR ANY SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER IN CONTRACT, OR OTHERWISE. The buyer acknowledges that he/she is not relying on the seller’s skill or judgment to select or furnish goods suitable for any particular purpose and that there are no warranties that extend beyond the description on the face here of. This warranty extends only to the original purchaser, and shall not apply to any products or parts that have been subject to misuse, neglect, accident, or abnormal conditions or operations. Claims for damage in transit are directed to the freight carrier upon receipt. iii Disclaimers The information in this manual has been carefully checked and is believed to be accurate. SAMMI INFORMATION SYSTEM CO.,LTD. assumes no responsibility for any infringements of patents or other rights of third parties which may result from its use. SAMMI INFORMATION SYSTEM CO.,LTD. assumes no responsibility for any inaccuracies that may be contained in this document. SAMMI INFORMATION SYSTEM CO.,LTD. makes no commitment to update or to keep current the information contained in this manual. SAMMI INFORMATION SYSTEM CO.,LTD. reserves the right to make improvements to this document and/or product at any time and without notice. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written permission of SAMMI INFORMATION SYSTEM CO.,LTD. © Copyright 2001 by SAMMI INFORMATION SYSTEM CO.,LTD. All rights reserved. FCC (Federal communiction commission) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the authority to operate equipment. This equipment must be installed and operated in accordance with provided instructions and the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. The professional installation and the installer are being responsible to the 20cm apart from the human body. iv ESD Precautions Integrated circuits on computer boards are sensitive to static electricity. To avoid damaging chips from electrostatic discharge, observe the following precautions: Do not remove boards or integrated circuits from their anti-static packaging until you are ready to install them. Before handling a board or integrated circuit, touch an unpainted portion of the system unit chassis for a few seconds. This helps to discharge any static electricity on your body. Wear a wrist-grounding strap, available from most electronic component stores, when handling boards and components. Trademarks Acknowledgments SAMMI INFORMATION SYSTEMS is a trademark of SAMMI INFORMATION SYSTEMS CO.,LTD. MS-DOS, and Windows ’95 are trademarks of Microsoft Corporation. AMD is a trademark of Advanced Micro Devices, Inc. AWARD is a trademark of Award Software. Inc. Cyrix is a trademark of Cyrix Corporation. IBM, PC/AT, PS/2, VGA are trademarks of International Business Machines Corporation. Intel and Pentium are trademarks of Intel Corporation. Winbond is a trademark of Winbond Electronics Corp. C&T is a trademark of Chips and Technologies, Inc. SST is a trademark of Silicon Storage Technology, Inc. Realtek is a trademark of Realtek Semiconductor Corporation. Other brand names and trademarks are the properties and registered brands of their respective owners. v Unpacking After unpacking the CPU card, check and see if the following items are included and in good condition. If any of the items is missing or damaged, notify your de…
Text truncated - open the document above for the full version.
American Telecommunications Certification Body Inc. 6731 Whittier Ave, McLean, VA 22101 March 3, 2004 RE: FCC ID: RQKMINISTATION12_ATCB001166 Attention: Joanna Chen I have a few comments on this Application. 1. Please note that while this device is called an “Industrial” computer, it does appear as if it can be used on the lap. If this is the case then SAR may be required as this puts it in the portable category. Please note that the manual states that the user is to operate the device in accordance with the provided instructions, but no instructions about the device not intended for portable use has been provided other than the 20cm statement.). Please explain and justify how this device is classified as mobile requiring a 20 cm separation (i.e. what steps has the manufacturer taken to restrict this and prevent this from being used on the lap? – is it too heavy? – are there ‘feet’ on the bottom that would make use on the lap not possible?). 2. Please note that there appears to be more than sufficient room on the outside of the device to accommodate the 2- condition statement as required by 15.19. Please provide a sample of the 2- condition label that will be placed on the exterior of the device itself. Alternately, please explain how this device meets the label requirements of 15.19(a)(5). 3. FYI – no action needed. Please note that the radiated emissions at 9648MHz shows a peak mode which complies with the average limit by only -.89dB and -0.6dB (see pages 31, 33 and 37 of the report). Since this frequency was not averaged but left as a peak reading, it is this reading that is to be reported as the closest margin to the limit. Consequently, unless 9648MHz is averaged, the report should reflect a margin of only 0.89dB and 0.6dB under the limit. In the future, please remember that you must report the worse case margin as compared to both the peak and average limits for 15.247 devices. This means that when the peak reading is under the average limit, you must report the results of the peak compared to the average limit, not peak limit alone. 4. FYI - Please note that your band edge limits are incorrect. The limit for 15.247 devices is 20dB below the fundamental not 0dBuV/m. While the device is compliant to the requirements, the table is showing incorrect limits. Please correct the table on page 52, 53 and 54 of the report. Also, please make the algebraic signs of the data consistent in all tables. If using your existing designation, the device data shows non-compliance, even though it is obvious it is compliant from the plots. Dennis Ward mailto:[email protected] The items indicated above must be submitted before processing can continue on the above referenced application. Failure to provide the requested information may result in application termination. Correspondence should be considered part of the permanent submission and may be viewed from the Internet after a Grant of Equipment Authorization is issued. Please do not respond to this correspondence using the email reply button. In order for your response to be processed expeditiously, you must submit your documents through the AmericanTCB.com website. Also, please note that partial responses increase processing time and should not be submitted. Any questions about the content of this correspondence should be directed to the sender.
From: joanna chen [mailto:[email protected]] Sent: Thursday, March 04, 2004 12:09 AM To: dward ATCB Cc: Gestek-Shine Subject: Re: RQKMINISTATION12 comments Importance: High Dear Dennis, I had uploaded documents to ATCB website. Regarding to your comments, the following is our reply after confirming with our client. 1. We had uploaded 4 installing photos for ministation12. In these photos, you can see it is used for forklift. It is strictly for the industrial application. 2. We had uploaded sample of the two conditions label. 3. We will follow it for next project. 4. We had uploaded revised test report. Please review it then reply to me ASAP if having any opinion of it. Thanks. Best regards, Joanna
GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 86 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 13. PHOTOGRAPHS FOR PRODUCT 1. Front View Of Industrial PC. (EUT) 2. Back View Of Industrial PC. (EUT)
MiniStation 12 label sample Size : 26 x 81mm SAMMI INFORMATION SYSTEMS CO.,LTD. Model MiniStation 12 PART NO SMI-7200-P SERIAL SM00140210 FCC ID RQKMINISTATION12 Power DC12V 5A Barcode label
GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 108 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 42. View Of Label.
GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 87 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 3. Inner View Of Industrial PC. (EUT) 4. Inner View Of Industrial PC. (EUT) GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 88 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 5. Inner View Of Industrial PC. (EUT) 6. Inner View Of Industrial PC. (EUT) GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 89 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 7. Inner View Of Industrial PC. (EUT). 8. Inner View Of Industrial PC. (EUT) GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 90 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 9. Inner View Of Industrial PC. (EUT). 10. Inner View Of Industrial PC. (EUT) GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 91 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 11. Inner View Of Industrial PC. (EUT). 12. Inner View Of Industrial PC. (EUT) GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 92 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 13. Inner View Of Industrial PC. (EUT). GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 93 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 14. Inner View Of Mother Board. 15. Inner View Of Mother Board. GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 94 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 16. Inner View Of Mother Board. 17. Inner View Of Mother Board. GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 95 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 18. Component Side Of Mother Board. 19. Solder Side Of Mother Board. GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 96 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 20. Component Side Of Mother Board. 21. Solder Side Of Mother Board. GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 97 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 22. Component Side Of Mother Board. 23. Solder Side Of Mother Board. GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 98 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 24. Component Side Of Mother Board. 25. Solder Side Of Mother Board. GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 99 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 26. Component Side Of Mother Board. 27. Solder Side Of Mother Board. GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 100 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 28. Inner View Of WLAN Card 29. Inner View Of WLAN Card GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 101 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 30. Inner View Of WLAN Card GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 102 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 31. Component Side Of Mother Board. 32. Solder Side Of Mother Board. GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 103 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLA…
Text truncated - open the document above for the full version.
GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 1 of 5 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 RF EXPOSURE EVALUATION DECLARATION SAMMI INFORMATION SYSTEMS CO., LTD EUT: Industrial PC Model Number: MiniStation 12 FCC ID: RQKMINISTATION12 Prepared for: SAMMI INFORMATION SYSTEMS CO., LTD 7-9 Fl., Seo Jo Bldg, 103-15, Galwor-Dong, Yong San-Ku, Seoul, Korea Report By : Global EMC Standard Tech. Corp. No.3 Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel : 886-2-2603-5321 Fax : 886-2-2603-5325 1.Test results given in this report only relate to the specimen(s) tested, measured. 2.This report is the property of GesTek, and shall not be reproduced, other than in full, without the written consent of GesTek. 3.The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. 4.All data in this report are traceable to national standard or international standard. GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 2 of 5 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 1. RF EXPOSURE EVALUATION 1.1. LIMITS According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm 2 ) Average Time (Minutes) (A) Limits for Occupational/ Control Exposures 300-1500 -- -- F/300 6 1500-100,000 -- -- 5 6 (B) Limits for General Population/ Uncontrolled Exposures 300-1500 -- -- F/1500 6 1500-100,000 -- -- 1 30 F= Frequency in MHz Friis Formula Friis transmission formula: Pd = (Pout*G)/(4*pi*r 2 ) Where Pd = power density in mW/cm 2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm 2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. 1.2. TEST PROCEDURE Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 3 of 5 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 1.3. TEST RESULT OF RF EXPOSURE EVALUATION Date of Test January 28, 2004 Temperature 20 deg/C EUT Industrial PC Humidity 60 %RH Working Cond. WLAN (802.11b) Antenna Gain Antenna Gain: The maximum Gain measured in fully anechoic chamber is 1.58 in linear scale. Output Power Into Antenna & RF Exposure Evaluation Distance: Channel No. Frequency (MHz) Output Power to Antenna (mW) Power Density at R = 20 cm (mW/cm 2 ) 1 2412.00 42.7563 0.0135 6 2437.00 39.9945 0.0126 11 2462.00 42.0727 0.0133 The power density Pd (4th column) at a distance of 20 cm calculated from the Friis transmission formula is far below the limit of 1 mW/cm 2 . GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 4 of 5 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 Date of Test January 28, 2004 Temperature 20 deg/C EUT Industrial PC Humidity 60 %RH Working Cond. WLAN (802.11g) Antenna Gain Antenna Gain: The maximum Gain measured in fully anechoic chamber is 1.58 in linear scale. Output Power Into Antenna & RF Exposure Evaluation Distance: Channel No. Frequency (MHz) Output Power to Antenna (mW) Power Density at R = 20 cm (mW/cm 2 ) 1 2412.00 125.8925 0.0397 6 2437.00 118.8502 0.0375 11 2462.00 123.3105 0.0389 The power density Pd (4th column) at a distance of 20 cm calculated from the Friis transmission formula is far below the limit of 1 mW/cm 2 . GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 5 of 5 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 Date of Test January 28, 2004 Temperature 20 deg/C EUT Industrial PC Humidity 60 %RH Working Cond. Bluetooth Antenna Gain Antenna Gain: The maximum Gain measured in fully anechoic chamber is 2.0 in linear scale. Output Power Into Antenna & RF Exposure Evaluation Distance: Channel No. Frequency (MHz) Output Power to Antenna (mW) Power Density at R = 20 cm (mW/cm 2 ) 1 2412.00 1.8408 0.0007 6 2437.00 1.8113 0.0007 11 2462.00 2.5942 0.0010 The power density Pd (4th column) at a distance of 20 cm calculated from the Friis transmission formula is far below the limit of 1 mW/cm 2 .
Certificate Gestek GESTEK Gestek Gestek GESTEK Gestek estek GESTEK Gestek GES T stek GESTEK Gestek GESTE tek GESTEK Gestek GESTEK ek GESTEK Gestek GESTEK k GESTEK Gestek GESTEK GESTEK Gestek GESTEK Certificate of Test February 2004 GesTek EMC Lab GesTek EMC LabGesTek EMC Lab GesTek EMC Lab N0. 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. TEL:886-2-2603-5321 FAX:886-2-2603-5325 SAMMI INFORMATION SYSTEMS CO., LTD Product Type : Industrial PC Model Number : MiniStation 12 Test Report Number : GTK-0312027 Date of Test : December 01, 2003- February 04, 2004 This Product was tested to the following standards at the laboratory of Global EMC Standard Tech. Corp., and found Compliance. Standards: FCC Part 15 Subpart C Paragraph 15.247 ANSI C63.4: 2001 Sharon Chang, President Date: February 24, 2004 http : //www.gestek.com.tw Accredited Laboratory GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 1 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 Test Report Application for Declaration of Conformity On Behalf Of SAMMI INFORMATION SYSTEMS CO., LTD EUT: Industrial PC Model Number: MiniStation 12 FCC ID: RQKMINISTATION12 Prepared for: SAMMI INFORMATION SYSTEMS CO., LTD 7-9 Fl., Seo Jo Bldg, 103-15, Galwor-Dong, Yong San-Ku, Seoul, Korea Report By :Global EMC Standard Tech. Corp. No.3 Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel : 886-2-2603-5321 Fax : 886-2-2603-5325 1.Test results given in this report only relate to the specimen(s) tested, measured. 2.This report is the property of GesTek, and shall not be reproduced, other than in full, without the written consent of GesTek. 3.The report must not be used by the client to claim product certification, approval, or endorsement by any agency of the federal government. 4.All data in this report are traceable to national standard or international standard. GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 2 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 TABLE OF CONTENTS DESCRIPTION PAGE 1. CERTIFICATION................................................................................................... 4 2. GENERAL INFORMATION ................................................................................... 5 2.1 PRODUCTION DESCRIPTION ............................................................................. 5 2.2 OPERATIONAL DESCRIPTION............................................................................ 7 2.3 TEST MODES & EUT COMPONENTS DESCRIPTION ........................................ 8 2.4 CONFIGURATION OF THE TESTED SYSTEM.................................................... 9 2.5 TEST FACILITY .................................................................................................. 11 2.6 TEST SETUP ...................................................................................................... 12 2.6.1 BLOCK DIAGRAM OF CONNECTIONS BETWEEN EUT AND SIMULATORS.. 12 2.7 EUT OPERATING CONDITIONS........................................................................ 12 3. CONDUCTION EMISSION DATA ....................................................................... 13 3.1 TEST EQUIPMENTS .......................................................................................... 13 3.2 BLOCK DIAGRAM OF TEST SETUP.................................................................. 13 3.3 CONDUCTED EMISSION LIMIT ......................................................................... 14 3.4 OPERATING CONDITION OF EUT .................................................................... 14 3.5 EUT CONFIGURATION ON MEASUREMENT ................................................... 14 3.6 CONDUCTED EMISSION DATA......................................................................... 14 3.7 CONDUCTED EMISSIONS MEASUREMENT RESULTS ................................... 15 4. RADIATION EMISSION DATA............................................................................ 16 4.1 TEST EQUIPMENT ............................................................................................. 16 4.2 OPEN TEST SITE SETUP DIAGRAM................................................................. 16 4.3 RADIATED EMISSION LIMIT.............................................................................. 17 4.4 EUT CONFIGURATION ...................................................................................... 17 4.5 OPERATING CONDITION OF EUT .................................................................... 17 4.6 RADIATED EMISSION DATA ............................................................................. 17 4.7 RADIATED EMISSIONS MEASUREMENT RESULTS ........................................ 18 5. PEAK POWER OUTPUT .................................................................................... 48 5.1 TEST EQUIPMENT ............................................................................................. 48 5.2 BLOCK DIAGRAM OF TEST SETUP.................................................................. 48 5.3 PEAK POWER OUTPUT LIMIT .......................................................................... 48 5.4 TEST RESULT .................................................................................................... 49 6. BAND EDGE....................................................................................................... 50 6.1 TEST EQUIPMENT ............................................................................................. 50 6.2 BLOCK DIAGRAM OF TEST SETUP.................................................................. 50 6.3 BAND EDG…
Text truncated - open the document above for the full version.
GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 83 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 12. PHOTOGRAPHS FOR TEST 12.1 TEST PHOTOGRAPHS FOR CONDUCTION GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 84 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 12.2 TEST PHOTOGRAPHS FOR RADIATION 30-1000MHz GESTEK Lab Report #: 0312027 N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C. Tel:886-2-2603-5321 Fax:886-2-2603-5325 Accredited Lab. Of BSMI, DNV, NEMKO, NVLAP. Page 85 of 111 Rev. 1 Listed Lab. of AUSTEL, Commerce, FCC, VCCI. NVLAP Lab Code:200085-0 Above 1GHz
No. 3, Pau-Tou-Tsou Valley, Chia-Pau Tsuen · Lin Kou Hsiang · Taiwan
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 2 | 15C | 2.40 GHz - 2.48 GHz | 2.60 mW |

HANDHELD TERMINAL(INDUSTRIAL PDA)
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
UHF RFID READER (BLUETOOTH EMBEDDED)
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
INDUSTRIAL TABLET COMPUTER
Equipment Class
DTS - Digital Transmission System
WIRELESS LAN MODULE
Equipment Class
DTS - Digital Transmission System
UHF-RFID READER
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter