® INSTEON LED Bulb (PAR38) 2674-222 2ZQHU·V0DQXDO Contents Getting Started INSTEON LED Bulb 4 Device Overview Do Not Connect to a Dimmer Leave Your Fixture On Linking INSTEON Links Understanding Linking 6 Linking to the INSTEON Hub using the iOS or Android App 8 Linking with a Single-Button Controller 9 Linking with a Multi-Button Controller 10 Multi-Linking or Making a Scene 11 Unlinking from a Single-Button Controller 12 Unlinking from a Multi-Button Controller 13 Multi-Unlinking or Removing a Scene 14 Software-Only Features Ramp Rate 16 Disable Linking on Power-up Always-On Wiring Always-On Wiring 18 Appendix :WLJPÄJH[PVUZ 22 Troubleshooting 24 *LY[PÄJH[PVUZHUK>HYUPUNZ 25 Product Warranty 26 3 Everything you need to quickly get up and running. Getting Started 4 Device OverviewDo Not Connect to a Dimmer INSTEON LED Bulb 0M`V\YZ^P[JOVYÄ_[\YLPZ6--JVTT\UPJH[PVU with the LED Bulb is lost. 05:;,653,+)\SIKPTZ\ZPUN05:;,65 JVTTHUKZ INSTEON ID Your LED Bulb does not have a set button. ;VSPURTHU\HSS`\UZJYL^[OL3,+)\SIMVYH TVTLU[HUKYLPUZLY[ X Leave Your Fixture OnLinking 0M`V\YÄ_[\YLPZJVU[YVSSLKI`H^HSS Z^P[JOJVUZPKLY^PYPUNHZHS^H`ZVU ? ON 5 05:;,65KL]PJLZJHUZ[HUKHSVULHUKM\UJ[PVUHZHSVJHSZ^P[JOVY KPTTLYI\[[OLPYYLHSWV^LYJVTLZ^OLU[OL`HYLJVUULJ[LK[VNL[OLY[V MVYTHJVU[YVSZ`Z[LT4VZ[05:;,65KL]PJLZJHUJVU[YVSVULHUV[OLY HUKIL[OLYLJPWPLU[VMJVU[YVS;OLWYVJLZZVMHZZVJPH[PUNT\S[PWSL 05:;,65KL]PJLZ[VVULHUV[OLYPZJHSSLKSPURPUN INSTEON Links 6 >OLUSPURPUN05:;,65KL]PJLZ[OLSPURZ[OH[ HYLJYLH[LKHYLVUL^H` The current state of the controlled device is Z[VYLKPU[OLSPUR!VUVMMVYKPTTLK Switch A will turn Switch B on and off but Switch B cannot turn Switch A on or off. ;OLZ^P[JO^PSS[\YUVU[OL3HTW+PTTLY[V 75% brightness. ASwitchBLamp Dimmer ® 75% 05:;,65KL]PJLZ[OH[JHU[\YUV[OLYKL]PJLZ on or off are called controllers. :LUZVYZ:^P[JOLZ2L`WHKZHUK[OL /\IHYLJVTTVUJVU[YVSSLYZ 05:;,65KL]PJLZ[OH[YLJLP]L[OLJVTTHUKVMH controller are called responders. :^P[JOLZ2L`WHKZ7S\N0U4VK\SLZHUK 0U3PUL4VK\SLZHYLJVTTVUYLZWVUKLYZ ® ® Neutral On Off Set N N LoadL1 LineL RespondersControllers Links Remember a Device’s StateLinks are One-Way Understanding Linking ® ® 7 Controller-Only :VTLKL]PJLZSPRLZLUZVYZJHUVUS`JVU[YVS other devices. ;OL4V[PVU:LUZVY^PSS[\YUVU[OL:^P[JO I\[[OLZ^P[JOJHUUV[JVU[YVS[OL4V[PVU Sensor. Responder-Only :VTLKL]PJLZJHUUV[JVU[YVSV[OLYKL]PJLZ" [OLZLKL]PJLZVUS`YLJLP]L05:;,65JVTTHUKZ :VTLKL]PJLZJHUVUS`SPURHZ responders to devices and scenes. LED BulbDimmer Switch X Understanding Linking Grouping DevicesUse Cross Linking @V\TH`^HU[[VNYV\W[VNL[OLY[^V KL]PJLZMVYL_HTWSLPUH]PY[\HS[OYLL^H` JVUÄN\YH[PVU-VY05:;,65[OPZPZJHSSLK cross linking. ;V*YVZZ3PURZPTWS`[\YUVU[OLKL]PJLZHUK WLYMVYT[OLSPURPUNWYVJLZZ[^PJLVUJLPU each direction. ;VTPYYVY:^P[JO(HUK)ZV[OH[[OL`LHJO control one another and the connected SVHK*YVZZ3PURPUNPZULJLZZHY` Link Switch A to Switch B and repeat to link Switch B to Switch A. ABLoad Motion Sensor ® X Dimmer Switch AB 8 Linking to the INSTEON Hub using the iOS or Android App 2 Tap the Add button. 1 34 -YVT9VVTZUH]PNH[L[V(SS+L]PJLZ :LSLJ[3,+)\SIMYVT[OLSPZ[VM devices. >OLUWYVTW[LK[\YUVU`V\YÄ_[\YL and screw in the LED Bulb. The Bulb ^PSSKV\ISLILLW Rooms All DevicesCheck-InFavorites BathroomBedroomHallway KitchenLiving RoomOutside 72º Add Device LED BulbThermostat Door Sensor Open/Close Sensor All Devices Back DoorBathroomBedroom Font DoorGarage DoorGarage Light Motion SensorOutside Lights 72º Add You can now control your LED )\SIMYVT[OL05:;,65/\I 9 Linking with a Single-Button Controller 2 4HRLZ\YL`V\YÄ_[\YLPZ6UHUK then screw in the LED Bulb. Your 3,+)\SI^PSSKV\ISLILLW 1 6U`V\Y05:;,65JVU[YVSSLYWYLZZ and hold the set button until the device beeps. @V\Y05:;,65JVU[YVSSLY^PSS now control your LED Bulb. 10 @V\Y05:;,65JVU[YVSSLY^PSS now control your LED Bulb. A B Linking with a Multi-Button Controller 2 4HRLZ\YL`V\YÄ_[\YLPZ6UHUK then screw in the LED Bulb. Your 3,+)\SI^PSSKV\ISLILLW 1 6U`V\Y05:;,65JVU[YVSSLY[HW the desired control button and then press and hold the set button until the device beeps. 11 Multi-Linking or Making a Scene 2 34 (KQ\Z[`V\YZJLULTLTILYZ[V [OLPYKLZPYLKZ[H[L!6UVMMVY IYPNO[ULZZSL]LSPMKPTTPUN LED Bulb 3HTW LED Bulb Appliance 6ULH[H[PTLZJYL^PU`V\Y3,+ )\SIZ-VYV[OLYKL]PJLZWYLZZ and hold the set button until they KV\ISLILLW Tap the set button on your 05:;,65JVU[YVSSLY[VÄUPZO building your scene. 1 6U`V\Y05:;,65JVU[YVSSLYWYLZZ and hold the set button until the KL]PJLILLWZ[OLU[HW[OLZL[ button. 50%72% 30% ON A B @V\Y05:;,65JVU[YVSSLY^PSS now control your scene. 12 Unlinking from a Single-Button Controller 1 6U`V\Y05:;,65JVU[YVSSLYWYLZZ and hold the set button until the device beeps. 2 7YLZZHUKOVSK[OLZL[I\[[VU again until the device beeps. 3 4HRLZ\YL`V\YÄ_[\YLPZ6UHUK then screw in the LED Bulb. Your 3,+)\SI^PSSKV\ISLILLW X @V\Y05:;,65JVU[YVSSLY^PSSUV longer control your LED Bulb. 13 A B 1 6U`V\Y05:;,65JVU[YVSSLY[HW the desired control button and then press and hold the set button until the device beeps. Unlinking from a Multi-Button Controller 2 7YLZZHUKOVSK[OLZL[I\[[VU again until the device beeps. 3 4HRLZ\YL`V\YÄ_[\YLPZ6UHUK then unscrew and reinsert the LED )\SI@V\Y3,+)\SI^PSSKV\ISL beep. X @V\Y05:;,65JVU[YVSSLY^PSSUV longer control your LED Bulb. 14 Multi-Unlinking or Removing a Scene 2 3 6ULH[H[PTL\UZJYL^HUK YLPUZLY[`V\Y3,+)\SIZ-VYV[OLY KL]PJLZWYLZZHUKOVSK[OLZL[ I\[[VU\U[PS[OL`KV\ISLILLW Tap the set button on your 05:;,65JVU[YVSSLY[VL_P[4\S[P <USPURPUNTVKL 1 6U`V\Y05:;,65JVU[YVSSLYWYLZZ and hold the set button until the KL]PJLILLW…
Text truncated - open the document above for the full version.
November 1, 2013 Subject: Unit Label LED PAR 38 Light Bulb Model: 2674-222 FCC ID: SBP26742 IC: 5202A-26742 Unit Label
November 1, 2013 LED PAR 38 Light Bulb Model: 2674-222 FCC ID: SBP26742 IC: 5202A-26742 Manufacturing date code, revision, and ID number placed on unit label Unit label placed on case. Unit Label Location
This report contains a total of 35 pages and may be reproduced in full only. Partial reproduction may only be done with the written consent of CKC Laboratories, Inc. SmartLabs, Inc. ADDENDUM TO TEST REPORT FOR 94820-8 INSTEON PAR38 Bulb Model: 2674 Tested To The Following Standards: FCC Part 15 Subpart C Sections 15.249 & 15.207 & RSS-210 Issue 8 Report No.: 94820-8A Date of issue: November 19, 2013 This test report bears the accreditation symbol indicating that the testing performed herein meets the test and reporting requirements of ISO/IEC 17025 under the applicable scope of EMC testing for CKC Laboratories, Inc. We strive to create long-term, trust based relationships by providing sound, adaptive, customer first testing services. We embrace each of our customers’ unique EMC challenges, not as an interruption to set processes, but rather as the reason we are in business. Page 2 of 35 Report No.: 94820-8A TABLE OF CONTENTS Administrative Information .......................................................................................................................... 3 Test Report Information ............................................................................................................................................ 3 Revision History ......................................................................................................................................................... 3 Report Authorization ................................................................................................................................................. 3 Test Facility Information ............................................................................................................................................ 4 Software Versions ...................................................................................................................................................... 4 Site Registration & Accreditation Information .......................................................................................................... 4 Summary of Results ................................................................................................................................................... 5 Conditions During Testing.......................................................................................................................................... 5 Equipment Under Test ............................................................................................................................................... 6 Peripheral Devices ..................................................................................................................................................... 6 FCC Part 15 Subpart C ................................................................................................................................... 7 AC Conducted Emissions 15.207 ................................................................................................................................ 7 Fundamental Field Strength 15.249(a) .................................................................................................................... 14 Voltage Variations15.31(e) ...................................................................................................................................... 17 Occupied Bandwidth 15.215(c) ............................................................................................................................... 19 99 % Bandwidth ....................................................................................................................................................... 22 Radiated Spurious Emissions 15.249(a) ................................................................................................................... 25 Band Edge Measurements 15.249(d) ...................................................................................................................... 29 Supplemental Information .......................................................................................................................... 34 Measurement Uncertainty ...................................................................................................................................... 34 Emissions Test Details .............................................................................................................................................. 34 Page 3 of 35 Report No.: 94820-8A ADMINISTRATIVE INFORMATION Test Report Information REPORT PREPARED FOR: REPORT PREPARED BY: SmartLabs, Inc. 16542 Millikan Ave. Irvine, CA 92606 Morgan Tramontin CKC Laboratories, Inc. 5046 Sierra Pines Drive Mariposa, CA 95338 Representative: John Lockyer Project Number: 94820 Customer Reference Number: 13-3JC1002-01 DATE OF EQUIPMENT RECEIPT: October 9, 2013 DATE(S) OF TESTING: October 9 – November 14, 2013 Revision History Original: Testing of the INSTEON PAR38 Bulb, 2674 to FCC Part 15 Subpart C Sections 15.249 & 15.207 & RSS-210 Issue 8. Addendum A: In the Radiated Spurious Emissions section, the Occupied Bandwidth plot was replaced with the correct radiated spurious emissions plot. Report Authorization The test data contained in this report documents the observed testing parameters pertaining to and are relevant for only the sample equipment tested in the agreed upon operational mode(s) and configuration(s) as identified herein. Compliance assessment remains the client’s responsibility. This report may not be used to claim product endorsement by A2LA or any government agencies. This test report has been authorized for release under quality control from CKC Laboratories, Inc. Steve Behm Director of Quality Assurance & Engineering Services CKC Laboratories, Inc. Page 4 of 35 Report No.: 94820-8A Test Facility Information Our laboratories are configured to effectively test a wide variety of product types. CKC…
Text truncated - open the document above for the full version.
16542 Millikan Avenue · Irvine, California · United States
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 914.9 MHz - 915.1 MHz | - |

Multi Sensor
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Bridge Controller
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Smart Outlet
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Smart Wall Switch
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
On/Off Outlet
Equipment Class
DXT - Part 15 Low Power Transceiver, Rx Verified