FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Haier Telecom (Qingdao) Co., Ltd./
  3. SG71008HC-C1100

SG71008HC-C1100Mobile Phone

Haier Telecom (Qingdao) Co., Ltd.
Mobile Phone - FCC ID SG71008HC-C1100 - Haier Telecom (Qingdao) Co., Ltd.
Click to zoom

Application Details

Equipment Class
PCE - PCS Licensed Transmitter held to ear
Date of Grant
Sep 14, 2010
Application Purpose
Original Equipment
Date of Application
Sep 14, 2010
Equipment Note
Mobile Phone
Frequency Range
1851.25000000 - 1908.75000000
Company
Haier Telecom (Qingdao) Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Attestation Statements

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Qingdao Haier Telecom Co. Ltd. C1100_ Skylink _User Guide 1 =Copyright©2010 Haier Technologies Co.., Ltd All Rights Reserved Reproduction, transfer, distribution or storage of part or all of the contents in this document in any form without the prior written permission as Haier Technologies Co.., Ltd. Statement The contents of this manual maybe different with the cell phone please according the cell phone. Haier Technologies Company reserves the right to revise this document or withdraw it at any time without prior notice. Safety Precautions Please read these simple guidelines. Not following them may be dangerous or illegal. Do not switch the phone on when Mobile Phone use is prohibited or when it may cause interference or danger. Do not place your phone and its accessories in containers with strong electromagnetic field. Obey all local laws. Always keep your hands free to operate the vehicle while driving. Your first consideration while driving should be road safety. Hospitals or health care facilities may be using equipment that could be sensitive to external radio frequency energy. Follow any regulations or rules in force. Do not use the phone at a refueling point. Do not use near fuel or chemicals. Follow any restrictions. Wireless devices can cause interference in aircraft. Keep the phone and all its parts, including accessories, out of the reach of small children. Use only approved batteries and chargers. Disconnect the charger from the power source when it is not in use. Do not leave the battery connected to a charger for more than a week, since overcharging may shorten its life. Only qualified personnel should service the phone or install the phone in a vehicle. Faulty installation or service may be dangerous and may invalidate any warranty applicable to the device. Qingdao Haier Telecom Co. Ltd. C1100_ Skylink _User Guide 2 Phone appearance Keys and Functions Press... To... Send key Making or answering a call. In standby mode, press this key to access the All calls screen. End (Power) key End calls or reject calls. Long press: Power on, power off. Left soft key Select the option displayed on the lower left corner of the screen. Right soft key Select the option displayed on the lower right corner of the screen. Navigation key Quick into Best tone,QQ,All contactsr and Messages menu. Increase or decrease the volume during a call. Number keys Enter numbers and characters. Press and hold the 1-9 keys to dial speed-dial phone numbers. * key ·Enter the * symbol. ·Press and hold to lock the keypad in idle mode ·Press twice to enter ‘+’ in idle mode. ·Press three times to enter ‘P’ in idle mode. Qingdao Haier Telecom Co. Ltd. C1100_ Skylink _User Guide 3 ·Press four times to enter ‘T’ in idle mode. ·Activate symbol mode. # key ·Enter the # symbol. ·Press and hold to enable or disable the vibrator . ·Press to switch between different input method in writing mode. Screen Icons Icon Description Icon Description Network signal strength Battery power level New message received Ringer mode Alarm clock on Silence mode Roaming service mode Vibrator enable Installing the Battery 1. Place the battery in the battery compartment. 2. Close the battery cover by sliding the cover upwards. Removing the Battery 1. Turn off your phone. 2. Remove the battery cover by sliding the cover downwards. 3. Use your fingernail to gently lift the upper edge of the battery outwards. 4. Take out the battery. Qingdao Haier Telecom Co. Ltd. C1100_ Skylink _User Guide 4 Charging the Battery 1. Plug the charger transformer into a standard outlet. 2. Insert the charger output into charging port of the bottom of the phone 3. The rolling of the electric quantity bar indicates that the phone begins to charge. 4. When the battery level full and stop rolled, the phone will display ‘Battery full ’. 5. After charging is complete, switch off the electric supply and pull out the charger’s jack. Using the Function Menu 1. In idle mode, press key to display the Menu interface. 2. Press key to scroll to a menu item. 3. Press key to display the menu. 4. Display the submenu in either of the ways: · Press key to scroll to a submenu item and press key to display the submenu. · Press the number key corresponding to the number of a submenu to display it. 5. Press key to return to the previous menu or quit the function menu. Press key to return to the idle screen. Qingdao Haier Telecom Co. Ltd. C1100_ Skylink _User Guide 5 Making a call 1. Dialing Select a desired entry from the names list or directly type in the phone number in idle mode, then press key to dial. 2. Making an international call z Press double times the * key until "+" appears on screen. z Enter the country code, area code (without prefix zero) and phone number. z Press key to dial. 3. Ending a call Press key to end a call. Receiving a call 1. Press key or any key (need setting) to answer the call. Or press [Silence] key once to close incoming ringer, then press [Answer] key again to receive the incoming call. 2. Press [Ignore] key or key to reject the incoming call. Phone Lock The phone lock code is used to protect your phone from unauthorized use. It can be set automatically to lock your phone each time it is switched on or when in idle mode. In this condition, you can only dial emergency call. Emergency call number is: 110,112,911,999. When phone is locked, to unlock user must enter the preset security code (The default code is 0000). Keypad lock The keypad lock can prevent you from accidental calls. If the keypad is locked, it unlocks when you receive a call. After the call, the lock automatically gets locked again. When the keypad is locked, calls may be possible to the official emergency number programmed in your phone. Press Disabel and then press * to unlock the keypad. Qingdao Haier Telecom Co. Ltd. C1100_ Skylink _User Guide 6 Text input method 1. Your phone provides following text input methods: z English input method: input English characters. z Numeric input meth…

Text truncated - open the document above for the full version.

Attestation Statements

Date: 03 Sep, 2010 Subject: FCC ID: SG71008HC-C1100 Attestation of USB port The USB port of this device is only used for charging, it is not available to transfer data by connect to a personal computer. Thank you for your attention to this matter. Yours Sincerely, Sincerely Yours, James Shi Type Approval Manager Haier Telecom (Qingdao) Co., Ltd.

Cover Letter(s)

Date: 03 Sep, 2010 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 To Whom It May Concern: The Haier Telecom (Qingdao) Co., Ltd. , the undersigned, hereby authorizes Mr. Wu Xuewen from Shenzhen Morlab Communications Technology Co., Ltd., to act on the behalf of the Haier Telecom (Qingdao) Co., Ltd. solely in matters relating to the application for an FCC equipment authorization for FCC ID # SG71008HC-C1100 including the signing of documents in connection with this Application. Necessary acts carried out by Haier Telecom (Qingdao) Co., Ltd. on our behalf of the Haier Telecom (Qingdao) Co., Ltd. in connection with the Application shall have the same effect as acts of the Haier Telecom (Qingdao) Co., Ltd.. The Haier Telecom (Qingdao) Co., Ltd. also hereby certify that no party to this application is subject to a denial of benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a). Thank you for your attention to this matter. Sincerely Yours, James Shi Type Approval Manager Haier Telecom (Qingdao) Co., Ltd.

Cover Letter(s)

Date: 03 Sep, 2010 To: Federal Communications Commission, Authorization & Evaluation Division, 7435 Oakland Mills Road, Columbia, MD 21046 Re: Haier Telecom (Qingdao) Co., Ltd. FCC ID: SG71008HC-C1100 FCC Part 24E Certification Confidentiality Request Gentlemen: This letter is to comply with 47 CFR 0.457 and 0.459 pertaining to confidentiality material. Haier Telecom (Qingdao) Co., Ltd. requests that the following documents regarding this submission for FCC ID: SG71008HC-C1100 be kept confidential: Exhibit Type File Name Block Diagram HC-C1100_Block Diagram.pdf Schematics HC-C1100_Schematics.pdf Operational Description HC-C1100_Operational description.pdf Part list HC-C1100_BOM.pdf Tune-Up-Procedure HC-C1100_Tune up procedure.pdf Those documents contain detailed system and equipment description and related information about the product which Haier Telecom (Qingdao) Co., Ltd. considers to be confidential proprietary, a custom design and, otherwise, not releasable to the general public. Since this design is a basis form which future technological products will evolve, Haier Telecom (Qingdao) Co., Ltd. considers this information would be of benefit to its competitors, and that the disclosure of the information in these documents would give competitors an unfair advantage in the market. James Shi Type Approval Manager Haier Telecom (Qingdao) Co., Ltd.

External Photos

External Photos 1. Front View of EUT 2. Back View of EUT 3. Side View of EUT

ID Label/Location Info

Label Label Location

Internal Photos

Internal Photos

RF Exposure Info

Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 1/26 Issue: A Date: 2009/10/06 1 COMOSAR E-FIELD PROBE CALIBRATION REPORT Prepared By: LUC Jérôme, SATIMO Project Description: SAR TEST BENCH Prepared For (End User): Shenzhen Morlab Communication Technology This document is issued by SATIMO, in confidence and is not to be reproduced in whole or in part without the prior written permission. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or in part without the prior written permission of SATIMO. Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 2/26 Issue: A Date: 2009/10/06 2 COMOSAR SEPT ISOTROPIC E-FIELD PROBE CALIBRATION REPORT DATE: 12/02/2009 REFERENCE: SN 37/08 EP80 OBJECT: COMOSAR SEPT ISOTROPIC E-FIELD PROBE MANUFACTURER: SATIMO SERIAL NUMBER: SN 37/08 EP80 CUSTOMER: Shenzhen Morlab Communication Technology CONTRACT: PF2130108b_SAR_Morlab DATE OF CALIBRATION: 24/09/200 9 WARRANTY: This Calibration certificate may not be reproduced other than in full. Calibration certificates without signature and seal are not valid. This documentation contains property information which is protected by copyright. All right are reserved. No part of this document may be photocopied, reproduced without the prior written agreement of SATIMO. SATIMO shall not be liable for errors contained herein or for incidental or consequential in connection with the furnishing, performance or use of this material. Warranty doesn’t apply to Normal wear, Normal tear, Improper use, Improper maintain, Improper installation. Date SAR TEAM MANAGER Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 3/26 Issue: A Date: 2009/10/06 3 PRODUCT DESCRIPTION Frequency Range 100 MHz - 30 GHz Probe length 330 mm Length of one dipole 4.5 mm Maximum external diameter 8 mm Probe extremity diameter 6.5 mm Distance between dipoles/probe extremity < 2.7 mm Resistance of the three dipole (at the connector) Dipole 1: R1=1.4382 MΩ Dipole 2: R2=1.4894 MΩ Dipole 3: R3=1.4683 MΩ Connector (HIROSE series SR30) 6 wire male (Hirose SR30series) The probe could be checked by measuring the resistance of the three dipoles. CALIBRATION TEST EQUIPMENT TYPE IDENTIFICATION Calibration bench CALISAR Multimeter Keithley 2000 Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 4/26 Issue: A Date: 2009/10/06 4 MEASUREMENT PROCEDURE Probe calibration is realized, in compliance with CENELEC EN 50361 and IEEE 1528 std, with CALISAR, Antennessa proprietary calibration system. The calibration is performed with the EN 50361 annexe technique using reference guide at the five frequencies. Where : P fw = Forward Power P bw = Backward Power a and b = Waveguide dimensions  = Skin depth Keithley configuration: Rate = Medium; Filter =ON; RDGS=10; FILTER TYPE =MOVING AVERAGE; RANGE AUTO After each calibration, a SAR measurement is performed on a validation dipole and compared with a NPL calibrated probe, to verify it. Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 5/26 Issue: A Date: 2009/10/06 5 PROBE UNCERTAINTIES Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 6/26 Issue: A Date: 2009/10/06 6 1. Calibration at 450.00 MHz A. Calibration parameters. Label GSM450 Epsilon 43.33 Sigma 0.84 S/m Temperature 21°C Antenna gain 2.03 dB Antenna S11 -10.50 dB Low limit detection (CW) 0.72 V/m (0.47 mW/kg) Calibration curves ei=f(V) (i=1,2,3) allow to obtain E-field value using the formula: 2 3 2 2 2 1 **EEEE= The following tables represent the calibration curves linearization by curve segment in CW signal. Ref: CR-280-1-08-SATB-A COMOSAR E-Field probe Calibration Report Page: 7/26 Issue: A Date: 2009/10/06 7 Calibration coefficients for the three dipoles in CW: v1 e1 v2 e2 v3 e3 0.584004 419.557857 -0.696059 435.622023 0.541191 412.830715 0.467833 339.207465 -0.556278 351.381991 0.469757 336.297240 0.376994 276.348283 -0.452232 288.647980 0.378826 274.224190 0.302778 224.954643 -0.359005 232.397390 0.305842 224.365698 0.241038 182.154071 -0.286978 188.889931 0.246562 183.825274 0.192549 148.484090 -0.230386 154.650994 0.195712 148.993075 0.154033 121.674762 -0.185412 127.378480 0.157543 122.783107 0.123397 100.276479 -0.147311 104.193802 0.125866 100.956090 0.099878 83.770361 -0.118637 86.660489 0.101471 84.063863 0.081165 70.553219 -0.095250 72.263937 0.082289 70.694342 0.065166 59.152028 -0.076788 60.795323 0.066427 59.538957 0.051916 49.592416 -0.061280 51.041514 0.053353 50.232492 0.041968 42.297602 -0.048746 43.022565 0.042906 42.675214 0.033724 36.126757 -0.039149 36.748110 0.034686 36.605243 0.021855 26.962568 -0.024798 27.024723 0.022272 27.149463 0.018405 23.975145 -0.020856 24.085809 0.018755 24.141334 0.015467 21.515985 -0.017534 21.515985 0.015767 21.615299 0.013018 19.309065 -0.014750 19.398191 0.013276 19.487731 0.010938 17.408496 -0.012392 17.529166 0.011157 17.569575 0.009022 15.586953 -0.010228 15.658899 0.009215 15.676938 0.007353 13.956010 -0.008328 13.988181 0.007484 14.020428 0.005989 12.466979 -0.006801 12.495719 0.006111 12.567858 0.004890 11.214019 -0.005573 11.265779 0.005003 11.330818 0.004019 10.133541 -0.004570 10.121882 0.004099 10.168601 0.003279 9.094132 -0.003739 9.157170 0.003352 9.125596 0.002660 8.095827 -0.003041 8.293946 0.002769 8.265350 0.002126 7.324219 -0.002453 7.366500 0.002188 7.358024 0.001685 6.565400 -0.001947 6.580536 0.001724 6.542765 0.001300 5.784440 -0.001511 5.718225 0.001334 5.757862 0.001123 5.245191 -0.001307 5.269400 0.001174 5.275471 0.000891 4.701768 -0.001057 4.723470 0.000924 4.728912 0.000704 4.209798 -0.000850 4.226839 0.000736 4.243862 0.000574 3.790376 -0.000689 3.791428 0.000603 3.830551 0.000457 3.396200 -0.000570 3.434303 0.000483 3.421852 0.000365 3.050686 -0.000463 3.078014 0.000389 3.079630 0.000292 2.745766 -0.000369 2.726866 0.000311 2.759206 0.000236 2.486639 -0.000312 2.489933 0.000246 2.460514 0.000…

Text truncated - open the document above for the full version.

RF Exposure Info

Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 1/6 Issue: B Date: 2009/10/05 1 DIPOLE 1800 MHZ CALIBRATION REPORT Prepared By: LUC Jérôme, SATIMO Project Description: SAR TEST BENCH Prepared For (End User): Shenzhen Morlab Communication Technology This document is issued by SATIMO, in confidence and is not to be reproduced in whole or in part without the prior written permission. The information contained herein is to be used only for the purpose for which it is submitted and is not to be released in whole or in part without the prior written permission of SATIMO. Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 2/6 Issue: B Date: 2009/10/05 2 DIPOLE 1800 MHz CALIBRATION REPORT DATE: 19/02/2009 REFERENCE: SN 36/08 DIPF101 OBJECT: COMOSAR IEEE REFERENCE DIPOLE MANUFACTURER: SATIMO SERIAL NUMBER: SN 36/08 DIPF101 CUSTOMER: Shenzhen Morlab Communication Technology CONTRACT: PF2130108b_SAR_Morlab DATE OF CALIBRATION: 2 3/09/2009 WARRANTY: This Calibration certificate may not be reproduced other than in full. Calibration certificates without signature and seal are not valid. This documentation contains property information which is protected by copyright. All right are reserved. No part of this document may be photocopied, reproduced without the prior written agreement of SATIMO. SATIMO shall not be liable for errors contained herein or for incidental or consequential in connection with the furnishing, performance or use of this material. Warranty doesn’t apply to Normal wear, Normal tear, Improper use, Improper maintain, Improper installation. Date SAR TEAM MANAGER Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 3/6 Issue: B Date: 2009/10/05 3 PRODUCT DESCRIPTION Dimension: L=72 mm/ h=41.7 mm / d=3.6 mm CALIBRATION TEST EQUIPMENT TYPE IDENTIFICATION DATE OF CALIBRATION Vector Network Analyzer HP8753D (SN: 5410A08882) 10-05-2009 MEASUREMENT PROCEDURE We placed the dipole under the flat part of SAM phantom fill with 1800 MHz head liquid. Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 4/6 Issue: B Date: 2009/10/05 4 Calibration was performed according to IEEE Std P1528-2003 and OET bulletin 65 Supplement C (Ed. 01-01) VSWR at 1800 MHz: -25.09 dB -25,09 -35 -30 -25 -20 -15 -10 -5 0 1,71,81,9 Frequency (GHz) S11 (dB) Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 5/6 Issue: B Date: 2009/10/05 5 SAR MEASUREMENT EQUIPEMENT Voltmeter Keithley (2000, SN:1000572) Date of calibration: 01-07-2009 Signal generator Rohde&Schwarz (SML_03, SN:101868) Date of calibration: 15-11-2008 Power amplifier Nuclétudes (ALB216, SN:10800) Date of calibration: 24-10-2008 Power meter Rohde&Schwarz (NRVD, SN:101066) Date of calibration: 04-07-2009 Probe SATIMO Bretagne (SN:EP37) CF (35.35,34.93,37.42) Date of calibration: 19-06-2009 SAR MEASUREMENT CONDITION Software OpenSAR V3 Phantom SATIMO Bretagne (SN: SN_20_07_SAM42) Liquid SATIMO Bretagne (Last Calibration: 19 09 08) Head Liquid Values: eps’ : 39,80 sigma : 1,45 Distance between the center of the dipole and the liquid (set with a spacer) 10 mm Area scan resolution dx=8mm/dy=8mm Zoom scan resolution dx=8mm/dy=8m/dz=5mm Frequency 1800 MHz Input power 30 dBm Expanded uncertainty (K=1) 8.09% SAR MEASUREMENT RESULT 10g 1g SAR measured Liquid : HL Input power : 1W 20,05 W/Kg + 1,24 % 39,32 W/Kg + 3,20 % Ref: CR-280-5-08-SATB-B COMOSAR Dipole 1800 MHz Calibration Report Page: 6/6 Issue: B Date: 2009/10/05 6 SAR MEASUREMENT PLOTS

RF Exposure Info

Report No.: SZ10080104S01 Page 2 of 81 Contents 1. GENERAL INFORMATION....................................................................................................3 1.1. Notes.........................................................................................................................................3 1.2. Organization item....................................................................................................................3 1.3. Conclusion................................................................................................................................3 2. TESTING LABORATORY.......................................................................................................4 2.1. Identification of the Responsible Testing Laboratory..........................................................4 2.2. Identification of the Responsible Testing Location..............................................................4 2.3. Accreditation Certificate........................................................................................................4 2.4. List of Test Equipments..........................................................................................................4 3. TECHNICAL INFORMATION ...............................................................................................4 3.1. Identification of Applicant......................................................................................................5 3.2. Identification of Manufacturer..............................................................................................5 3.3. Equipment Under Test (EUT)................................................................................................5 3.3.1. Photographs of the EUT..................................................................................................6 3.3.2. Identification of all used EUTs........................................................................................6 4. TEST RESULTS.........................................................................................................................6 4.1. Applied Reference Documents...............................................................................................6 4.2. Test Environment/Conditions................................................................................................7 4.3. Operational Conditions During Test.....................................................................................7 4.3.1. Informations On The Testing..........................................................................................8 4.3.2. The Measurement System.............................................................................................10 4.3.3. Uncertainty Assessment.................................................................................................12 4.4. MEASUREMENT PROCEDURES....................................................................................16 4.4.1. Procedures Used To Establish Test Signal....................................................................16 4.5. Items used in the Test Results List.......................................................................................17 4.6. Test Results List.....................................................................................................................18 ANNEX A ACCREDITATION CERTIFICATE..........................................................................20 ANNEX B PHOTOGRAPHS OF THE EUT ................................................................................21 ANNEX C GRAPH TEST RESULTS ...........................................................................................24 Report No.: SZ10080104S01 Page 4 of 81 2. Testing Laboratory 2.1. Identification of the Responsible Testing Laboratory Company Name: Shenzhen Morlab Communications Technology Co., Ltd. Morlab Laboratory Department: Morlab Laboratory Address: 3/F, Electronic Testing Building, Shahe Road, Nanshan District, Shenzhen, 518055 P. R. China Responsible Test Lab Manager: Mr. Shu Luan Telephone: +86 755 86130268 Facsimile: +86 755 86130218 2.2. Identification of the Responsible Testing Location Name: Shenzhen Morlab Communications Technology Co., Ltd. Morlab Laboratory Morlab Laboratory Address: 3/F, Electronic Testing Building, Shahe Road, Nanshan District, Shenzhen, 518055 P. R. China 2.3. Accreditation Certificate Accredited Testing Laboratory: No. CNAS L3572 (see Annex A) 2.4. List of Test Equipments No. Instrument Type Cal. Date Cal. Due 1 PC Dell (Pentium IV 2.4GHz, SN:X10-23533) 2 Network Emulator Rohde&Schwarz (CMU200, SN:105894) 2009-9-26 1year 3 Voltmeter Keithley (2000, SN:1000572) 2009-9-24 1year 4 Synthetizer Rohde&Schwarz (SML_03, SN:101868) 2009-9-24 1year 5 Amplifier Nucl udes (ALB216, SN:10800) 2009-9-24 1year 6 Power Meter Rohde&Schwarz (NRVD, SN:101066) 2009-9-24 1year 7 Probe Antennessa (SN:SN_3708_EP80) 2009-9-24 1year 8 Phantom Antennessa (SN:SN_36_08_SAM62) 2009-9-24 1year 9 Liquid Antennessa (Last Calibration:21 08 08)2010-8-21 1year Report No.: SZ10080104S01 Page 5 of 81 3. Technical Information Note: the following data is based on the information by the applicant. 3.1. Identification of Applicant Company Name: Qingdao Haier Telecom Co.,Ltd Address: No.1,Haier Road Hi-tech Zone,Qingdao,266101,P.R.China 3.2. Identification of Manufacturer Company Name: Qingdao Haier Telecom Co.,Ltd Address: No.1,Haier Road Hi-tech Zone,Qingdao,266101,P.R.China 3.3. Equipment Under Test (EUT) Brand Name: Haier Type Name: Haier Marking Name: HC-C1100 Hardware Version: P3v4 Software Version: C2060CT-HSP-R01.00.06-CT Frequency Bands: CDMA 1900MHz (channel 25:1851.2MHz, channel 600:1880.00MHz, Channel 1175:1908.8MHz) Modulation Mode: CDMA Antenna type: Build inside Accessories: Charger; Battery Battery Model: H15312 Battery specification: 1000mAh 3.7V Report No.: SZ10080104S01 Page 6 of 81 3.3.1. Photo…

Text truncated - open the document above for the full version.

Test Report

Report No.: SZ10080104E01 Page 2 of 32 TABLE OF CONTENTS 1. TEST RESULT CERTIFICATION .......................................................................................... 4 2. GENERAL INFORMATION .................................................................................................... 5 2.1 Equipment under Test (EUT) Description ............................................................................... 5 2.2 Test Standards and Results ........................................................................................................ 6 2.3 Facilities and Accreditations ...................................................................................................... 7 2.3.1 Facilities .................................................................................................................................... 7 2.3.2 Test Equipments ........................................................................................................................ 7 2.3.3 Test Environment Conditions .................................................................................................... 8 3. 47 CFR PART 2, PART 24E REQUIREMENTS ..................................................................... 9 3.1 General Information................................................................................................................... 9 3.1.1 Conducted Related Tests ........................................................................................................... 9 3.1.2 Radiated Power and Spurious Emission Tests ........................................................................ 10 3.1.3 Frequency Stability Test .......................................................................................................... 11 3.2 Conducted RF Output Power .................................................................................................. 12 3.2.1 Requirement ............................................................................................................................ 12 3.2.2 Test Procedure ......................................................................................................................... 12 3.2.3 Test Result ............................................................................................................................... 12 3.3 Occupied Bandwidth ................................................................................................................ 15 3.3.1 Occupied Bandwidth Definition ............................................................................................. 15 3.3.2 Test Result ............................................................................................................................... 15 3.4 Conducted Spurious Emission ................................................................................................. 18 3.4.1 Requirement ............................................................................................................................ 18 3.4.2 Test Procedure ......................................................................................................................... 18 3.4.3 Test Result ............................................................................................................................... 18 3.5 Band Edge ................................................................................................................................. 21 3.5.1 Requirement ............................................................................................................................ 21 3.5.2 Test Result ............................................................................................................................... 21 3.6 Transmitter Radiated Power (EIRP) ...................................................................................... 23 3.6.1 Requirement ............................................................................................................................ 23 3.6.2 Test Procedure ......................................................................................................................... 23 Report No.: SZ10080104E01 Page 3 of 32 3.6.3 Test Result ............................................................................................................................... 23 3.7 Radiated Spurious Emission .................................................................................................... 26 3.7.1 Requirement ............................................................................................................................ 26 3.7.2 Test Procedure ......................................................................................................................... 26 3.7.3 Test Result ............................................................................................................................... 27 3.8 Frequency Stability ................................................................................................................... 31 3.8.1 Frequency Stability Requirement ............................................................................................ 31 3.8.2 Test Procedure ......................................................................................................................... 31 3.8.3 Test Result ...............................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

David Yang(Certification Manager)
[email protected]+86-532-88937275Fax: +86-532-88939585

Technical Contact

Shenzhen Morlab CommunicationsXuewen Wu
[email protected]+86-755-86120298

FL.3,Electronic Testing Bld, Shahe Rd, · Shenzhen · China

Test Firm

Shenzhen Morlab Communications Technology Co.,LtdShu Luan
[email protected]0086-0755-86113898Fax: 0086-0755-86130218

Technical Specifications

#Rule PartsFrequency RangePower OutputEmissionTolerance
124E1.85 GHz - 1.91 GHz440.00 mW1M29F9W0.1000000000 ppm
Confidentiality
Long Term
Grant Notes
Power Output is EIRP. SAR compliance for body-worn operating conditions is limited to the specific configuration tested for this filing. Bodyworn operations are restricted to belt-clips, holsters or similar accessories that have no metallic component in the assembly and must provide at least 15mm separation between the device and the user's body. End users must be informed of the body worn requirements for satisfying RF Exposure compliance.The highest reported SAR values are: Head: 1.210 W/kg; Bodyworn: 0.525 W/kg.

Other Applications from Haier Telecom (Qingdao) Co., Ltd.

Mobile Phone - FCC ID SG7201511L50 - Haier Telecom (Qingdao) Co., Ltd.
SG7201511L50

Mobile Phone

Dec 07, 2015

Equipment Class

DTS - Digital Transmission System
Mobile Phone - FCC ID SG7201511L32 - Haier Telecom (Qingdao) Co., Ltd.
SG7201511L32

Mobile Phone

Dec 03, 2015

Equipment Class

PCE - PCS Licensed Transmitter held to ear
L51 - FCC ID SG71507L51 - Haier Telecom (Qingdao) Co., Ltd.
SG71507L51

L51

Dec 03, 2015

Equipment Class

DTS - Digital Transmission System
Smart phone - FCC ID SG720151015I70 - Haier Telecom (Qingdao) Co., Ltd.
SG720151015I70

Smart phone

Nov 03, 2015

Equipment Class

PCE - PCS Licensed Transmitter held to ear
Mobile phone - FCC ID SG720151010G10 - Haier Telecom (Qingdao) Co., Ltd.
SG720151010G10

Mobile phone

Oct 22, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter