Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Annex A 1-9627/19-01-01_AnnexA External photos of the Equipment Under Test This addendum is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Document authorized: Tobias Wittenmeier Testing Manager Radio Communications & EMC CTC advanced GmbHUntertuerkheimer Str. 6-10 66117 Saarbruecken / Germany Phone: +49 681 5 98 - 0 Fax: +49 681 5 98 - 9075 web: ctcadvanced.com e-mail: [email protected] Photos Photo 1 Photo 2 2020-02-21Document No. 1-9627/19-01-01_AnnexA2/6 Photo 3 Photo 4 2020-02-21Document No. 1-9627/19-01-01_AnnexA3/6 Photo 5 Photo 6 2020-02-21Document No. 1-9627/19-01-01_AnnexA4/6 Photo 7 2020-02-21Document No. 1-9627/19-01-01_AnnexA5/6 Document history VersionApplied changesDate of release initial release2020-02-21 - END OF DOCUMENT - 2020-02-21Document No. 1-9627/19-01-01_AnnexA6/6
Sivantos GmbH - R&D PD eSW HW WS-L - Richard Rose Page 1 of 2 Erlangen, 2020-01-15 External pictures NFMI Module 2 β Host: Silk X FCC ID: SGI-MIM002 IC: 267AB-MIM002 Sivantos GmbH - R&D PD eSW HW WS-L - Richard Rose Page 2 of 2 Erlangen, 2020-01-15
Annex B 1-9627/19-01-01_AnnexB Internal photos of the Equipment Under Test This addendum is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Document authorized: Tobias Wittenmeier Testing Manager Radio Communications & EMC CTC advanced GmbHUntertuerkheimer Str. 6-10 66117 Saarbruecken / Germany Phone: +49 681 5 98 - 0 Fax: +49 681 5 98 - 9075 web: ctcadvanced.com e-mail: [email protected] Photos Photo 1 Photo 2 2020-02-21Document No. 1-9627/19-01-01_AnnexB2/4 Photo 3 Photo 4 2020-02-21Document No. 1-9627/19-01-01_AnnexB3/4 Document history VersionApplied changesDate of release initial release2020-02-21 - END OF DOCUMENT - 2020-02-21Document No. 1-9627/19-01-01_AnnexB4/4
Sivantos GmbH - R&D PD eSW HW WS-L - Richard Rose Page 1 of 2 Erlangen, 2020-01-15 Internal pictures NFMI Module 2 β Host: Silk X FCC ID: SGI-MIM002 IC: 267AB-MIM002 Sivantos GmbH - R&D PD eSW HW WS-L - Richard Rose Page 2 of 2 Erlangen, 2020-01-15
BNetzA-CAB-02/21-102 TEST REPORT Test report no.: 1-9627/19-01-03-B Testing laboratory Applicant CTC advanced GmbH Untertuerkheimer Strasse 6 β 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: http://www.ctcadvanced.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2005) by the Deutsche Akkreditierungsstelle GmbH (DAkkS) The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate starting with the registration number: D-PL-12076-01. Sivantos GmbH Henri-Dunant-StraΓe 100 91058 Erlangen / GERMANY Phone: +49 9131 308-0 Contact: Richard Rose e-mail: [email protected] Phone: +49 (9131) 308-3727 Manufacturer Sivantos GmbH Henri-Dunant-StraΓe 100 91058 Erlangen / GERMANY Test standard/s FCC - Title 47 CFR Part 15 FCC - Title 47 of the Code of Federal Regulations; Chapter I; Part 15 - Radio frequency devices RSS - 210 Issue 10 Spectrum Management and Telecommunications Radio Standards Specification - Licence-Exempt Radio Apparatus: Category I Equipment RSS - Gen Issue 5 Spectrum Management and Telecommunications Radio Standards Specifications - General Requirements and Information for the Certification of Radio Apparatus For further applied test standards please refer to section 3 of this test report. Test Item Kind of test item: Hearing Aid Module Model name: NFMI Module 2 FCC ID: SGI-MIM002 IC: 267AB-MIM002 Frequency: 3.28 MHz Technology tested: Inductive coupling Antenna: Integrated antenna Power supply: 1.1 V to 1.5 V DC by zinc air battery Temperature range: 0Β°C to +55Β°C This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report authorized: Test performed: Christoph Schneider Tobias Wittenmeier Lab Manager Testing Manager Radio Communications & EMC Radio Communications & EMC Test report no.: 1-9627/19-01-03-B Β© CTC advanced GmbH Page 2 of 27 1 Table of contents 1 Table of contents ............................................................................................................................................ 2 2 General information ....................................................................................................................................... 3 2.1 Notes and disclaimer .......................................................................................................................... 3 2.2 Application details ............................................................................................................................... 3 2.3 Test laboratories sub-contracted ...................................................................................................... 3 3 Test standard/s, references and accreditations .......................................................................................... 4 4 Test environment ............................................................................................................................................ 5 5 Test item .......................................................................................................................................................... 5 5.1 General description ............................................................................................................................. 5 5.2 Additional information ........................................................................................................................ 5 6 Description of the test setup ......................................................................................................................... 6 6.1 Shielded semi anechoic chamber ...................................................................................................... 7 6.2 Shielded fully anechoic chamber ...................................................................................................... 8 6.3 Test setup for normalized measurement configurations ................................................................ 9 7 Sequence of testing ..................................................................................................................................... 10 7.1 Sequence of testing radiated spurious 9 kHz to 30 MHz ............................................................... 10 7.2 Sequence of testing radiated spurious 30 MHz to 1 GHz .............................................................. 11 8 Summary of measurement results ............................................................................................................. 12 9 Additional comments ................................................................................................................................... 13 10 Measurement results ................................................................................................................................ 14 10.1 Occupied bandwidth ...................................................................................................................... 14 10.2 Field strength of the fundamental ................................................................................................ 16 10.3 Field strength of the harmonics and spurious ........................................................................... 17 10.4 Receiver spurious emissions and cabinet radiations ................................................................ 22 11 Observations ............................................................................................................................................. 24 Annex A Glossary .......................................................................................................................................... 25 Annex B Document history ............β¦
Text truncated - open the document above for the full version.
Annex D 1-9627/19-01-01_AnnexD Setup photos of the Equipment Under Test This addendum is electronically signed and valid without handwritten signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Document authorized: Tobias Wittenmeier Testing Manager Radio Communications & EMC CTC advanced GmbHUntertuerkheimer Str. 6-10 66117 Saarbruecken / Germany Phone: +49 681 5 98 - 0 Fax: +49 681 5 98 - 9075 web: ctcadvanced.com e-mail: [email protected] Photos Photo 1 Photo 2 2020-02-21Document No. 1-9627/19-01-01_AnnexD2/6 Photo 3 Photo 4 2020-02-21Document No. 1-9627/19-01-01_AnnexD3/6 Photo 5 Photo 6 2020-02-21Document No. 1-9627/19-01-01_AnnexD4/6 Photo 7 Photo 8 2020-02-21Document No. 1-9627/19-01-01_AnnexD5/6 Document history VersionApplied changesDate of release initial release2020-02-21 - END OF DOCUMENT - 2020-02-21Document No. 1-9627/19-01-01_AnnexD6/6
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 3.28 MHz - 3.28 MHz | - |

Remote Controller
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
BTE Hearing Aid
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
easyPocket remote control 3.28 MHz
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterRemote Control Device
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Remote control for hearing instruments
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter