Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
www.siemens.com/hearing Life sounds brilliant. easyTek™ 8VHU*XLGH_0DVWHU Content%HIRUH\RXVWDUWդ ,QFOXGHGLQGHOLYHU\դ &RPSDWLEOHKHDULQJLQVWUXPHQWVդ &RPSRQHQWVդ *HWWLQJVWDUWHGդ &KDUJLQJդ :HDULQJHDV\7HNSURSHUO\դ 3DLULQJKHDULQJLQVWUXPHQWVZLWKHDV\7HNդ 5HPRWHFRQWUROIXQFWLRQVդ 7XUQLQJHDV\7HNRQRIIդ $XGLRVWUHDPLQJդ 6XSSRUWHGGHYLFHVդ 3DLULQJ%OXHWRRWKGHYLFHVդ 3DLULQJRXUWUDQVPLWWHUVդ $XGLRVWUHDPLQJIXQFWLRQVդ 6HYHUDOGHYLFHVFRQQHFWHGդ 0DNLQJSKRQHFDOOVդ 3KRQHFDOOIXQFWLRQVդ 0DLQWHQDQFHDQGVHUYLFHդ &OHDQLQJդ 8QSDLULQJդ 5HVHWWLQJդ )XUWKHULQIRUPDWLRQդ 2SHUDWLQJGLVWDQFHդ &RQÀJXUDWLRQRIKHDULQJLQVWUXPHQWVդ $FFHVVRULHVդ HDV\7HN$SSդ 7URXEOHVKRRWLQJդ ,PSRUWDQWVDIHW\LQIRUPDWLRQդ 3HUVRQDOVDIHW\դ 3URGXFWVDIHW\դ ,PSRUWDQWLQIRUPDWLRQդ ,QWHQGHGXVHդ 6\PEROVդ 7UDQVSRUWDQGVWRUDJHFRQGLWLRQVդ 7HFKQLFDOGDWDRIWKHSRZHUVXSSO\դ 'LVSRVDOLQIRUPDWLRQդ &RQIRUPDQFHLQIRUPDWLRQդ &RXQWU\VSHFLÀFLQIRUPDWLRQդ 4XLFNUHIHUHQFHդ %XWWRQRYHUYLHZդ /('VWDWXVLQGLFDWLRQդ HDV\7HNLVDUHPRWHFRQWURODQGDXGLRVWUHDPLQJGHYLFHLQRQHGHYLFH,WFRQQHFWVPDQ\ %OXHWRRWK ZLUHOHVV WHFKQRORJ\HQDEOHGGHYLFHVVWDQGDUGDXGLRGHYLFHVDQG)0UHFHLYHUVZLWK\RXUKHDULQJLQVWUXPHQWV &$87,215HDGWKLVXVHUJXLGHWKRURXJKO\DQGFRPSOHWHO\DQGIROORZWKHVDIHW\LQIRUPDWLRQLQWKLVGRFXPHQWWRDYRLGGDPDJHRULQMXU\ ,QFOXGHGLQGHOLYHU\&KHFNWKHSDFNDJHFRQWHQWV ঔ HDV\7HNZLWKQHFNORRS ঔ 86%FDEOHIRUFKDUJLQJ ঔ 3RZHUVXSSO\ZLWKGLIIHUHQWDGDSWHUV GHSHQGLQJRQ\RXUFRXQWU\ 7KH%OXHWRRWKZRUGPDUNDQGORJRVDUHRZQHGE\WKH%OXHWRRWK6, *,QFDQGDQ\ XVHRIVXFKPDUNVE\6LHPHQV$*LVXQGHUOLFHQVHV2WKHUWUDGHP DUNVDQGWUDGHQDPHV DUHWKRVHRIWKHLUUHVSHFWLYHRZQHUV Before you start &RPSDWLEOHKHDULQJLQVWUXPHQWVHDV\7HNZRUNVZLWKRXUVSHFLÀFZLUHOHVVKHDULQJLQVWUXPHQWV<RXU+HDULQJ&DUH3URIHVVLRQDOZLOODGYLVH\RXRQWKHFRPSDWLEOHPRGHOV &RPSRQHQWV ૣૣૣૣૣ 0XOWLIXQFWLRQEXWWRQ /('VWDWXVLQGLFDWRU RUDQJHJUHHQEOXH 1HFNORRS LVDOVRWKHDQWHQQD 0LFURSKRQHRSHQLQJV ૠ 86%SRUWIRUFKDUJLQJ ૡ 5HVHWEXWWRQ ૢ 3RUWIRU)0UHFHLYHU ૣ 3RUWIRUDXGLRGHYLFHV VWDQGDUGPPDXGLRMDFN 9ROXPHEXWWRQV )ROORZWKHLQVWUXFWLRQVLQWKLVFKDSWHUWRPDNHHDV\7HNUHDG\IRURSHUDWLRQ&KDUJLQJ 127,&(3OHDVHPDNHVXUHWKDWWKHSRZHUSOXJLVHDVLO\DFFHVVLEOHWRUHPRYHLWIURPSRZHUVXSSO\LIQHFHVVDU\ %DWWHU\VWDWXVZKLOHFKDUJLQJ VWHDG\RUDQJHOLJKW &KDUJLQJ VWHDG\JUHHQOLJKW &KDUJLQJLVFRPSOHWHG Getting started 7KHRUDQJH/('LQGLFDWHVWKHEDWWHU\VWDWXV %DWWHU\VWDWXV RUDQJH/('RII %DWWHU\LVVXIÀFLHQWO\FKDUJHG ÁDVKLQJIDVWIRUVHFRQGVZKHQDEXWWRQLVSUHVVHG %DWWHU\LVORZ )XUWKHULQIRUPDWLRQ ঔ 2QO\XVHWKH86%FDEOHDQGSRZHUDGDSWHUWKDWFDPHZLWKWKHGHYLFH6HOHFWWKHDGDSWHUWKDWLVXVHGLQ\RXUFRXQWU\ ঔ :KHQFKDUJLQJYLDFRPSXWHU ক HDV\7HNVZLWFKHVRIIDXWRPDWLFDOO\ ক <RXUFRPSXWHUPXVWEHWXUQHGRQDQGQRWLQVOHHSRUVWDQGE\PRGH2WKHUZLVHWKHEDWWHU\PD\GUDLQLQVWHDGRIFKDUJH ঔ 7\SLFDOO\IXOO\FKDUJLQJWDNHVKRXUV ঔ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ঔ %RWKKHDULQJLQVWUXPHQWVDUHWXUQHGRII WKHEDWWHU\FRPSDUWPHQWVDUHRSHQ DQGZLWKLQRSHUDWLQJGLVWDQFH ঔ HDV\7HNLVWXUQHGRII ঔ 1HFNORRSLVSOXJJHGLQWRERWKVLGHVDQGHDV\7HNLVZRUQDURXQGWKHQHFN 3DLULQJ 3UHVV XQWLOWKHJUHHQ/('WXUQVRQ 7KLV WDNHVDSSUR[LPDWHO\VHFRQGVHDV\7HNVHDUFKHVIRUKHDULQJLQVWUXPHQWVQHDUE\ 7XUQRQWKHKHDULQJLQVWUXPHQWVZKLOHWKHJUHHQ/('LVÁDVKLQJ &ORVHWKHEDWWHU\FRPSDUWPHQW ,I\RXDUHZHDULQJWZRKHDULQJLQVWUXPHQWVERWKLQVWUXPHQWVPXVWEHWXUQHGRQ 3DLULQJPD\WDNHVHYHUDOVHFRQGV7KHJUHHQ/('LQGLFDWHVWKHSDLULQJVWDWXV 3DLULQJVWDWXVIRUKHDULQJLQVWUXPHQWVÁDVKLQJWKHQRQIRUVHFRQGVWKHQRII 3DLULQJLVÀQLVKHG$QDFRXVWLFVLJQDOLVSOD\HG<RXFDQ QRZXVHHDV\7HN ÁDVKLQJIRUPLQXWHVWKHQRII +HDULQJLQVWUXPHQWVFRXOGQRWEHSDLUHG5HIHUWRVHFWLRQ 7URXEOHVKRRWLQJ :KHQSDLULQJLVÀQLVKHGHDV\7HNLVUHDG\ ঔ IRUUHPRWHFRQWUROIXQFWLRQV5HIHUWRVHFWLRQ5HPRWHFRQWUROIXQFWLRQV ঔ IRUSDLULQJ%OXHWRRWKGHYLFHVDVORQJDVWKHEOXH/('LVÁDVKLQJ 5HIHUWRVHFWLRQ3DLULQJ%OXHWRRWK GHYLFHV,I\RXZDQWWRSDLU%OXHWRRWKGHYLFHVQRWQRZEXWODWHURQSUHVV 5HPRWHFRQWUROIXQFWLRQVHDV\7HNLVDUHPRWHFRQWUROIRU\RXUKHDULQJLQVWUXPHQWV7KHIROORZLQJIXQFWLRQVDUHDYDLODEOH )XQFWLRQ 'HVFULSWLRQ 9ROXPH RU 3UHVVVKRUWO\WRDGMXVWVWHSE\VWHS3UHVVDQGKROGXQWLOGHVLUHGYROXPHLVUHDFKHG +HDULQJSURJUDP VKRUWSUHVV 6ZLWFKHVWRWKHQH[WKHDULQJSURJUDP 7KLVIXQFWLRQLVQRWDYDLODEOHGXULQJDXGLRVWUHDPLQJ 7XUQRQRII VWDQGE\ DQG ORQJSUHVV VHFRQGV 7XUQV\RXUKHDULQJLQVWUXPHQWVRQRURII )XUWKHULQIRUPDWLRQ ঔ ,I\RXDUHZHDULQJWZRKHDULQJLQVWUXPHQWVERWKLQVWUXPHQWVDUHDGMXVWHGDWWKHVDPHWLPH ঔ $IWHUWXUQLQJWKHKHDULQJLQVWUXPHQWVRQZLWKHDV\7HNWKHSUHYLRXVO\XVHGYROXPHDQGKHDULQJSURJUDPDUHVHW <RXFDQTXLFNO\WXUQWKHKHDULQJLQVWUXPHQWVEDFNRQE\SUHVVLQJWKHPXOW…
Text truncated - open the document above for the full version.
CON FIDENTIALITY REQU EST for Certification Service in USA Federal Communication Commission Equipment Authorization Division, Application Processing Branch 7435 Oakland Mills Road Columbia, MD 21048 2015-0+01 TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commission's Rules (47 C.F.R.) and Section §552(bX4) of the Freedom of lnformation Act, we requests confidentiality for the following products: FCC ID sGt-wL401 Model name easyTek For the product stated above, we request permanent confidentiality for exhibits which contain Operational Description, Block Diagram, Schematics, Parts Lists or Tune Up lnformation. The above exhibits contain our trade secrets and proprietary information that could be of benefit to our competitors. lf you have any questions, please feelfree to contact me at the address shown below. Sincerely, Lars Johansen Sivantos GmbH Gebbertstrasse 125 91058 Erlangen Germany Phone: +49 (91 31 )308-3569 Fax: +49 (91 31 )308-3207 Email : lars.johansen@sivantos. com SHORT-TERM CONFIDENTIALITY REQUEST Federal Communication Commission Equipment Authorization Divisioru Application Processing Branch 7435OakJand Mills Road Columbia, MD 21048 2U4-0+U TO WHOM IT MAY CONCERN Pursuant to Paragraphs §0.457 and 0.459 of the Commissiort's Ru1es (47 C.F.R.) and:' Section §552(bX4) of the Freedom of . Information Act, we requests short term confidentiality for the following product FCC ID Number Product Title/Model SGI-WL401 easyTek For the product stated above, we request that the following information be held confidential: 1. Extemal and Internal Photographs 2. TestSetup Photos 3. User Manual We request this confidentiality on the basis of ensuring that business sensitive information rernins confidential until the actual marketing of our new device, which is planned for 2015{9-30 If you have any questions, please feel free to contact me at the address shown below. Sincerely, Lars Johansen Sivantos GmbH Gebbertstrasse 125 91058 Erlangen Germany Phone: + 49 (9131)30&3569 F ax: +49 (9131)308-3207 Email [email protected]
Boguslavskij SIVANTOS RD PWD WSD 2015-01-23 Description of the changes of the EasyTek electronic design Preface The electronic design of the EasyTek was modified to achieve higher transmission power of the magnetic inductive transmission in the 3.28MHz band. The aim is to achieve more stable communication link with particular types of the hearing aids. Topology of the sender prior to the change FELIX8 COILM VDOUB 3.9Vpp 0.39Vpp 33uH Neckloop antenna 3.3uH The antenna loop is connected in series with ballast inductance, the voltage on the antenna is 0.39Vpp in transmit mode. Topology of the sender after the change FELIX8 COILM VDOUB BUF p_srcfg_reg_04 Neckloop antenna 3.3uH 33uH 3.9Vpp 5.5Vpp Receive path 33R The same unchanged antenna loop is connected via a buffer in the way that voltage on the coil is 5.5Vpp. With this measure, higher transmit power (+23dB) is achieved. The circuitry can be controlled by the firmware of the EasyTek to select between unchanged transmit power (+0dB) and increased transmit power (+23dB) according to the connected hearing aid type.
Test report no.: 1-9111_14-01-01_AnnexA Page 1 of 6 Annex A This test report annex is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report annex authorised: Tobias Wittenmeier Radio Communications & EMC Test report no.: 1-9111_14-01-01_AnnexA Page 2 of 6 External photos of the EUT Photo 1: Photo 2: Test report no.: 1-9111_14-01-01_AnnexA Page 3 of 6 Photo 3: Photo 4: Test report no.: 1-9111_14-01-01_AnnexA Page 4 of 6 Photo 5: Photo 6: Test report no.: 1-9111_14-01-01_AnnexA Page 5 of 6 Photo 7: Test report no.: 1-9111_14-01-01_AnnexA Page 6 of 6 Document history Version Applied changes Date of release Initial release 2015-03-16
Test report no.: 1-9111_14-01-01_AnnexB Page 1 of 5 Annex B This test report annex is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report annex authorised: Tobias Wittenmeier Radio Communications & EMC Test report no.: 1-9111_14-01-01_AnnexB Page 2 of 5 Internal photos of the EUT Photo 1: Photo 2: Test report no.: 1-9111_14-01-01_AnnexB Page 3 of 5 Photo 3: Photo 4: Test report no.: 1-9111_14-01-01_AnnexB Page 4 of 5 Photo 5: Test report no.: 1-9111_14-01-01_AnnexB Page 5 of 5 Document history Version Applied changes Date of release Initial release 2015-03-18
FCC ID: SGI-WL400 IC: 267AB-WL400 Model: easyTek SAR test exclusion according to KDB447498 ( General RF Exposure Guidance v05) Equation from Chapter 4.3.1: Standalone SAR test exclusion considerations page 11 and ff. (1) Standalone SAR test exclusion for 100 MHz to 6 GHz at test separation distances ≤ 50mm ( Threshold 1-g;10-g ) × d seperation / f 0.5 where Threshold 1-g;10-g is 3 for 1-g; 7.5 for 10-g d seperation is the min. test separation distance; 5mm is used if the distance is less f is the RF channel transmit frequency The table below gives the calculated maximal power that could be used for source based time averaged conducted power, adjusted for tune up tolerance. If this is below the calculated value SAR testing is obsolete. f in [MHz ]d separation [mm] Threshold 1-g;10-g Powerlimit [mW] P max-declared [mW] Exclusion 2480.00539.532.51yes (2) Standalone SAR test exclusion below 100 MHz < 50mm 0.5 × (Threshold 100MHz ) × (1+log(100/f)) [0,5 x Threshold100MHz × (1+log(100/f)] where Threshold 1-g;10-g is 3 for 1-g; 7.5 for 10-g f is the RF channel transmit frequency Threshold 100MHz,50mm is Threshold 1-g;10-g × d / f 0.5 ; with f = 100MHz and d=50mm The table below gives the calculated maximal power that could be used for source based time averaged conducted power, adjusted for tune up tolerance. If this is below the calculated value SAR testing is obsolete. f in [MHz] Thres hold 1-g;10-g Thres hold 100MHz,50mm Powerlimit [mW] P max-declared [mW] Exclusion 3.283474.34589.162.5yes Oleksandr Hnatovskiy CETECOM ICT Services GmbH Untertürkheimer Str.6-10 - 66117 Saarbrücken - Germany
TEST REPORT Test report no.: 1-9111/14-01-06-B Testing laboratory Applicant CETECOM ICT Services GmbH Untertuerkheimer Strasse 6 – 10 66117 Saarbruecken / Germany Phone: + 49 681 5 98 - 0 Fax: + 49 681 5 98 - 9075 Internet: http://www.cetecom.com e-mail: [email protected] Accredited Testing Laboratory: The testing laboratory (area of testing) is accredited according to DIN EN ISO/IEC 17025 (2005) by the Deutsche Akkreditierungsstelle GmbH (DAkkS) The accreditation is valid for the scope of testing procedures as stated in the accreditation certificate with the registration number: D-PL-12076-01-00 Sivatos GmbH Henri-Durant-Straße 100 91058 Erlangen / GERMANY Phone: -/- Fax: +49 9131 308-3207 Contact: Clemens Meythaler e-mail: [email protected] Phone: +49 9131 308-3000 Manufacturer Hi-P Electronics Technology Co Ltd, (Suzhou) No. 86, Liufeng Road, Hedong Instrial Park, Guoxiang Avenue, Wuzhong District. 215128, Suzhou City / CHINA Test standard/s 47 CFR Part 15 Title 47 of the Code of Federal Regulations; Chapter I; Part 15 - Radio frequency devices RSS - 210 Issue 8 Spectrum Management and Telecommunications Radio Standards Specification - Licence- exempt Radio Apparatus (All Frequency Bands): Category I Equipment RSS - Gen Issue 4 Spectrum Management and Telecommunications Radio Standards Specifications - General Requirements and Information for the Certification of Radio ApparatusSpectrum Management and Telecommunications Radio Standards Specifications - General Requirements and Information for the Certification of Radio Apparatus For further applied test standards please refer to section 3 of this test report. Test Item Kind of test item: Remote Controller Model name: easyTek FCC ID: SGI-WL401 IC: 267AB-WL400 Frequency: 3.28 MHz Technology tested: Proprietary data transmission Antenna: External loop neck antenna Power supply: 3.7 V DC by Li-ion battery Temperature range: 0°C to +45°C This test report is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report authorised: Test performed: Christoph Schneider Tobias Wittenmeier Radio Communications & EMC Radio Communications & EMC Test report no.: 1-9111/14-01-06-B Page 2 of 21 1 Table of contents 1 Table of contents ............................................................................................................................................ 2 2 General information ....................................................................................................................................... 3 Notes and disclaimer ..................................................................................................................................... 3 Application details .......................................................................................................................................... 3 3 Test standard/s ............................................................................................................................................... 3 4 Test environment ............................................................................................................................................ 4 5 Test item .......................................................................................................................................................... 4 Additional information ................................................................................................................................... 4 6 Test laboratories sub-contracted ................................................................................................................. 4 7 Description of the test setup ......................................................................................................................... 5 Radiated measurements chamber F ............................................................................................................. 5 Radiated measurements chamber C ............................................................................................................ 6 AC conducted ................................................................................................................................................. 7 Conducted measurements ............................................................................................................................ 7 8 Summary of measurement results ............................................................................................................... 8 9 Additional comments ..................................................................................................................................... 8 10 Measurement results ................................................................................................................................. 9 Timing of the transmitter ............................................................................................................................... 9 Occupied bandwidth .................................................................................................................................... 10 Field strength of the fundamental .............................................................................................................. 12 Field strength of the harmonics and spurious .......................................................................................... 13 Conducted limits .......................................................................................................................................... 16 11 Test equipment and ancillaries used for tests ..................................................................................... 18 12 Observations ...............................................................................................................…
Text truncated - open the document above for the full version.
Test report no.: 1-9111_14-01-01_AnnexD Page 1 of 6 Annex D This test report annex is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the public keys can be requested at the testing laboratory. Test report annex authorised: Tobias Wittenmeier Radio Communications & EMC Test report no.: 1-9111_14-01-01_AnnexD Page 2 of 6 EUT Test setup photos Photo 1: Photo 2: Test report no.: 1-9111_14-01-01_AnnexD Page 3 of 6 Photo 3: Photo 4: Test report no.: 1-9111_14-01-01_AnnexD Page 4 of 6 Photo 5: Photo 6: Test report no.: 1-9111_14-01-01_AnnexD Page 5 of 6 Photo 7: Photo 8: Test report no.: 1-9111_14-01-01_AnnexD Page 6 of 6 Document history Version Applied changes Date of release Initial release 2015-03-19
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 3.28 MHz - 3.28 MHz | - |

NFMI Module 2
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
BTE Hearing Aid
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
easyPocket remote control 3.28 MHz
Equipment Class
DXX - Part 15 Low Power Communication Device TransmitterRemote Control Device
Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Remote control for hearing instruments
Equipment Class
DSS - Part 15 Spread Spectrum Transmitter