SW8SD42000N1Human Presence Sensor

Good Way Technology Co., Ltd.

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 17, 2024
Application Purpose
Original Equipment
Date of Application
Mar 13, 2024
Equipment Note
Human Presence Sensor
Frequency Range
2412.00000000 - 2462.00000000
Company
Good Way Technology Co., Ltd.
Country
Taiwan

Documents & Files

Select a file to view

Attestation Statements

↗

Cover Letter(s)

↗
↗

ID Label/Location Info

↗

RF Exposure Info

↗

Test Report

↗
↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Attestation Statements

Applicant Declaration QSF27-14-04 Rev 1.0 Rev. Feb 6, 2023 Page 1 of 1 Original Issue: Jan. 4, 2021 SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia 30024 United States Applicant Legal Business Name Good Way Technology Co., Ltd. Address 3F, No. 135, Ln. 235, Baociao Rd., Sindian Dist., New Taipei City Grantee Code SW8 FCC ID SW8SD42000N1 Authorized Contact Name Alex Lee Contact Email [email protected] Contact Phone 886-2-8919-1200#3719 I, the undersigned, certify that I am an authorized signatory for the Applicant and therefore declare; a) in accordance with 47CFR2.911(d), all of the statements herein and the exhibits attached hereto are true and correct to the best of my knowledge and belief. b) in accepting a Grant of Equipment Authorization issued by a TCB, under the authority of the FCC, as a result of the representations made in thi s application, the Applicant is responsible for: (1) labeling the equipment with the exact FCC ID as specified in this application, (2) compliance statement labeling pursuant to the applicable rules, (3) compliance of the equipment with the applicable technical rules, c) if the Applicant is not the actual manufacturer of the equipment, appropriate arrangements have been made with the manufacturer to ensure that production units of this equipment will continue to comply with the FCC’s technical requirements. d) in accordance with 47 CFR 2.909 and KDB394321, the Applicant has read, understood and agrees to accept that they are the responsible party and agree to abide by their responsibilities as specified under 47 CFR 2.909 and KDB394321. e) in accordance with ISO 17065, FCC KDB641163, FCC KDB610077, KDB394321 and RSP-100, the Applicant has read, understood, accepts and agrees to abide by the post market surveillance requirements. (1) the Applicant understands, accepts and agrees t hat a sample may be requested for surveillance testing. (2) the Applicant shall make provisions to always have a production sample available upon request by SGS, FCC and/or ISED. (3) the Applicant shall, upon request by SGS, at the Applicant’s expense, provide a production sample of the requested product to SGS, FCC and/or ISED as instructed. The sample shall include all support devices, cables, software, accessories or other hardware or software required for evaluation, review, certification and audit surveillance of products certified by SGS. f) neither the Applicant nor any party to the application is subject to a denial of Federal benefits, that includes FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. §862 because of a conviction for possession or distribution of a controlled substance. See 47CFR 1.2002(b) for the definition of a “party” for these purposes. g) the Applicant has read, understood, accepts and agrees to abide by the SGS North America, Inc.(TCB) terms and conditions. Link to CFRs: https://www.fcc.gov/wireless/bureau-divisions/technologies-systems-and-innovation-division/rules-regulations-title-47 Link to KDBs: https://apps.fcc.gov/oetcf/kdb/index.cfm Link to RSP-100: https://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01130.html Link to the Covered List: Covered List Good Way Technology Co., Ltd. (“the applicant”) certifies that the equipment for which authorization is sought is not “covered” equipment prohibited from receiving an equipment authorization pursuant to section 2.903 of the FCC rules. Good Way Technology Co., Ltd. (“the applicant”) certifies that, as of the date of the filing of the application, the applicant is not identified on the Covered list, established pursuant to §1.50002, as an entity producing “covered” equipment. Applicant Signature: Date:February 21, 2024 Print Name: Alex Lee Title: Manager *NOTE: This declaration cannot be signed by an Agent, it shall be signed by an authorized person listed in the FCC database

Cover Letter(s)

Date: January 23, 2024 To: SGS North America Inc. 620 Old Peachtree Road SUITE 100 Suwanee, Georgia United States From: Good Way Technology Co., Ltd. 3F, No. 135, Ln. 235, Baociao Rd., Sindian Dist., New Taipei City Regarding: Confidentiality Request regarding application for FCC ID: SW8SD42000N1 LONG TERM CONFIDENTIALITY Pursuant to 47 CFR Section 0.459 and 0.457 of the commission’s rules, the applicant hereby request confidential treatment of the documents listed below, associated with the certification application referenced above. Schematic(s) Block Diagrams Operational Descriptions The documents above contain proprietary information not released to the publi c. Public disclosure of this information may prove harmful to the business of the applicant. SHORT TERM CONFIDENTIALITY Additionally, the applicant requests the following documents be held confidential until the device is marketed or 180 days from the grant date, whichever is less. If the device is marketed within 180 days of the Grant Date, the applicant will notify the TCB per FCC KDB 726920 D01 Confidentiality Request Procedures. External Photos Internal Photos Test Setup Photos User manual(s) Sincerely, Name (Printed): Alex Lee Title: Manager Signature:

ID Label/Location Info

SD42000N1 20231121 silkscreen 3.9mm 8.8mm PMS Cool Grag 8C

RF Exposure Info

Project No: TM-2311000089P FCC ID: SW8SD42000N1 Page 1 / 14 Report No.: TMWK2311004153KS Rev.: 02 No.11, Wugong 6th Rd., Wugu Dist., New Taipei City , Taiwan /新北市五股區五工六路11號 t:(886-2) 2299-9720 f:(886-2) 2299-9721 www.sgs.com.tw Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of client’s instruction, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced, except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Compliance Certification Services Inc. 程智科技股份有限公司 Member of the SGS Group RF Exposure Evaluation Report FCC 47 CFR § 2.1091 for Human Presence Sensor Model Name.: SD42000N1 Prepared for: GOOD WAY TECHNOLOGY CO., LTD. 3F, No. 135, Ln. 235, Baociao Rd., Sindian Dist., New Taipei City 231, Taiwan Prepared by Compliance Certification Services Inc. Wugu Laboratory No.11, Wugong 6th Rd., Wugu Dist., New Taipei City, Taiwan. Issue Date: March 1, 2024 Note: This document may be altered or revised by Compliance Certification Services Inc. personnel only, and shall be noted in the revision section of the document. The client should not use it to claim product endorsement by TAF, NIST or any government agencies. The test results in the report only apply to the tested sample. This document cannot be reproduced except in full, without prior written approval of the Company. 本報告未經本公司書面許可,不可部份複製。 Page 2 / 14 Report No.: TMWK2311004153KS Rev.: 02 Revision History Rev. Issue Date Revisions Effect Page Revised By 00 January 23, 2024 Initial Issue ALL Peggy Tsai 01 February 6, 2024 See the following Note Rev. (01) P.7, 12, 13 Peggy Tsai 02 March 1, 2024 See the following Note Rev. (02) P.7 Peggy Tsai Rev. (01): 1. Modify Frequency bands and Antenna Specification in section 3.2. 2. Modify MPE Exemption Option B in section 5. 3. Modify Simultaneous Transmission Exempt in section 6. Rev. (02): 1. Modify Antenna Specification in section 3.2. This document cannot be reproduced except in full, without prior written approval of the Company. 本報告未經本公司書面許可,不可部份複製。 Page 3 / 14 Report No.: TMWK2311004153KS Rev.: 02 Table of Contents 1 ATTESTATION OF TEST RESULTS ................................................................... 4 2 TEST SPECIFICATION, METHODS AND PROCEDURES ................................. 5 3 DEVICE UNDER TEST (DUT) INFORMATION .................................................... 6 3.1 DUT DESCRIPTION ..................................................................................... 6 3.2 WIRELESS TECHNOLOGIES ...................................................................... 7 4 MAXIMUM PERMISSIBLE EXPOSURE .............................................................. 8 4.1 LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) ...................... 8 4.2 MPE CALCULATION METHOD ................................................................... 9 4.3 MPE EXEMPTION ...................................................................................... 10 4.4 MULTIPLE RF SOURCES.......................................................................... 11 5 MPE EXEMPTION OPTION B ............................................................................ 12 6 SIMULTANEOUS TRANSMISSION EXEMPT ................................................... 13 6.1 SUM OF THE WIFI 2.4GHZ + BLUETOOTH ............................................. 13 7 FACILITIES ........................................................................................................ 14 This document cannot be reproduced except in full, without prior written approval of the Company. 本報告未經本公司書面許可,不可部份複製。 Page 4 / 14 Report No.: TMWK2311004153KS Rev.: 02 1 Attestation of Test Results Applicant Name GOOD WAY TECHNOLOGY CO., LTD. Model Name SD42000N1 Applicable Standards FCC 47 CFR § 2.1091 FCC 47 CFR § 1.1307 FCC 47 CFR § 1.1310 Published RF exposure KDB procedures Receive EUT Date: November 9, 2023 Compliance Certification Services Inc. , tested the above equipment in accordance with the requirements set forth in the above standards. Determination of compliance is based on the results of the compliance measurement,not taking into account measurement instrumentation uncertainy.All indications of Pass/Fail in this report are opinions expressed by Compliance Certification Services Inc, based on interpretations and/or observations of test results. The test results show that the equipment tested is capable of demonstrating compliance with the requirements as documented in this report. Approved & Released By: Sky Zhou Asst. Section Manager Compliance Certification Services Inc. This document cannot be reproduced except in full, without prior written approval of the Company. 本報告未經本公司書面許可,不可部份複製。 Page 5 / 14 Report No.: TMWK2311004153KS Rev.: 02 2 Test Specification, Methods and Procedures The tests documented in this report were performed in accordance with FCC 47 CFR § 2.1091, the following FCC Published RF exposure KDB procedures: o 447498 D0…

Text truncated - open the document above for the full version.

Test Report

Sporton International Inc. (Kunshan) Page Number : 1 of 30 TEL : +86-512-57900158 Issued Date : Mar. 11, 2024 Version : 2.0 OTA Antenna Performance Data Summary APPLICANT : ESPRESSIF SYSTEMS (SHANGHAI) CO., LTD EQUIPMENT : ESP8684-WROOM-06C BRAND NAME : ESPRESSIF MODEL NAME : ESP-ANT E DEVICE RECEIVING DATE : Aug. 11, 2023 TEST DATE(S) : Aug. 11, 2023 Reviewed by: Approved by: Feynman Liu / Vice Manager Kevin Chu / Manager Sporton International Inc. (Kunshan) No. 1098, Pengxi North Road, Kunshan Economic Development Zone Jiangsu Province 215300 People’s Republic of China Sporton International Inc. (Kunshan) Page Number : 2 of 30 TEL : +86-512-57900158 Issued Date : Mar. 11, 2024 Version : 2.0 OTA Test Report DATA NO.: OQ381713 Table of Contents Revision History --------------------------------------------------------------------------------------------------------------------- 3 1. Administration Data ----------------------------------------------------------------------------------------------------------- 4 1.1 Testing Laboratory ------------------------------------------------------------------------------------------------------ 4 1.2 Applicant ------------------------------------------------------------------------------------------------------------------- 4 2. General Information ----------------------------------------------------------------------------------------------------------- 5 2.1 Description of Device Under Test (DUT) --------------------------------------------------------------------------- 5 2.2 EUT Photographs ------------------------------------------------------------------------------------------------------- 5 3. Measurement Environment ------------------------------------------------------------------------------------------------- 6 3.1 Ambient Condition------------------------------------------------------------------------------------------------------- 6 3.2 Test Equipment List ----------------------------------------------------------------------------------------------------- 6 4. Test procedure ------------------------------------------------------------------------------------------------------------------ 7 5. Summary of Test Results ---------------------------------------------------------------------------------------------------- 8 6. Photographs of Test Configuration -------------------------------------------------------------------------------------- 9 7. 2D/3D Free Space Pattern Plots ----------------------------------------------------------------------------------------- 10 Sporton International Inc. (Kunshan) Page Number : 3 of 30 TEL : +86-512-57900158 Issued Date : Mar. 11, 2024 Version : 2.0 OTA Test Report DATA NO.: OQ381713 Revision History DATA NO. VERSION DESCRIPTION ISSUED DATE OQ381713 1.0 Initial issue of this report Jan. 25, 2024 OQ381713 2.0 1. Add General Information 2. Add Test Engineer and Measurement Environment 3. Add Test procedure Mar. 11, 2024 Sporton International Inc. (Kunshan) Page Number : 4 of 30 TEL : +86-512-57900158 Issued Date : Mar. 11, 2024 Version : 2.0 OTA Test Report DATA NO.: OQ381713 1. Administration Data 1.1 Testing Laboratory Test Site Sporton International Inc. (Kunshan) Test Site Location No. 1098, Pengxi North Road, Kunshan Economic Development Zone Jiangsu Province 215300 People’s Republic of China TEL: +86-0512-5790-0158 Chamber □ OTA01-KS □ OTA02-KS □ OTA03-KS ■ OTA04-KS □ OTA05-KS Test Engineer Emma Zhou 1.2 Applicant Company Name ESPRESSIF SYSTEMS (SHANGHAI) CO., LTD Address Suite 204, Block 2, 690 Bibo Road, Zhang Jiang Hi-Tech Park, Shanghai, China Sporton International Inc. (Kunshan) Page Number : 5 of 30 TEL : +86-512-57900158 Issued Date : Mar. 11, 2024 Version : 2.0 OTA Test Report DATA NO.: OQ381713 2. General Information 2.1 Description of Device Under Test (DUT) Product Feature & Specification Equipment ESP8684-WROOM-06C Brand Name ESPRESSIF Model Name ESP-ANT E DUT Dimension (mm) L: 15.80 W: 5.57 H: 1.00 Antenna Type PIFA Antenna HW Version v1.0 SW Version v1.0 2.2 EUT Photographs Sporton International Inc. (Kunshan) Page Number : 6 of 30 TEL : +86-512-57900158 Issued Date : Mar. 11, 2024 Version : 2.0 OTA Test Report DATA NO.: OQ381713 3. Measurement Environment 3.1 Ambient Condition Temperature (°C ): 25±5°C Humidity (%): <60% 3.2 Test Equipment List Name Manufacturer Type/Model Serial Number Calibration Last Cal. Due Date Network Analyzer Agilent E5071C MY46317418 2023/01/05 2024/01/04 Switch Control ETS-Lindgren EMCenter 00160100 NCR NCR Diagonal Dual Polarized Horn ETS-Lindgren 3164-08 00099205 NCR NCR Multi-Devices Controller ETS-Lindgren 2090-OPT1 00066604 NCR NCR Medium Duty Holder ETS-Lindgren 2015 N/A NCR NCR Sleeve Dipole Antenna ETS-Lindgren EMCO 3126-2500 00203963 2022/10/7 2024/10/6 Note: Antenna gain was measured in the anechoic chamber (Measurement System: ETS-Lindgren AMS-8500, SW Version: EMQuest 100 V1.08). Sporton International Inc. (Kunshan) Page Number : 7 of 30 TEL : +86-512-57900158 Issued Date : Mar. 11, 2024 Version : 2.0 OTA Test Report DATA NO.: OQ381713 4. Test procedure 1. Setup for testing facility: Connect all the equipments according to the figure below: 2. Run ETS-Lindgren EMQuestTest software script,Hit Run button to execute measurement. 3. Save Measurement result Network Analyzer QuiQt Zone Measurement Antenna (Receiving Part) Cable H Cable V Quiet Zone DUT Sporton International Inc. (Kunshan) Page Number : 8 of 30 TEL : +86-512-57900158 Issued Date : Mar. 11, 2024 Version : 2.0 OTA Test Report DATA NO.: OQ381713 5. Summary of Test Results Test / Position Gain / Free Space Frequency (MHz) 2397 2402 2407 2412 2417 2422 2427 2432 2437 2442 2447 2452 2457 2462 2467 2472 2477 2482 2487 Avg Gain -1.7 -1.7 -1.6 -1.7 -1.6 -1.6 -1.5 -1.5 -1.4 -1.4 -1.3 -1.3 -1.2 -1.2 -1.3 -1.3 -1.4 -1.4 -1.5 Peak Gain 1.4 1.5 1.5 1.5 1.6 1.7 1.8 1.9 2.1 2.2 2.3 2.4 2.5 2.6 2.6 2.6 2.7 2.7 2.7 Directivity 3.1 3.1 3.1 3.2 3.2 3.3 3.4 3.4 3.5 3.5 3.6 3.7 3.7 3.8 3.9 4.0 4.1 4.1…

Text truncated - open the document above for the full version.

Test Report

Project No: TM-2311000089P FCC ID: SW8SD42000N1 Page: 1 / 91 Report No.: TMWK2311004152KR Rev.: 05 No.11, Wugong 6th Rd., Wugu Dist., New Taipei City , Taiwan /新北市五股區五工六路11號 t:(886-2) 2299-9720 f:(886-2) 2299-9721 www.sgs.com.tw Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days only. 除非另有說明,此報告結果僅對測試之樣品負責,同時此樣品僅保留90天。本報告未經本公司書面許可,不可部份複製。 This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com.tw/Terms-and-Conditions and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com.tw/Terms-and-Conditions. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of client’s instruction, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced, except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Compliance Certification Services Inc. 程智科技股份有限公司 Member of the SGS Group RADIO TEST REPORT FCC 47 CFR PART 15 SUBPART C Test Standard FCC Part 15.247 Product name Human Presence Sensor Brand Name GOOD WAY Model No. SD42000N1 Test Result Pass Statements of Conformity Determination of compliance is based on the results of the compliance measurement, not taking into account measurement instrumentation uncertainty. The test Result was tested by Compliance Certification Services Inc. The test data, data evaluation, test procedures, and equipment configurations shown in this report were given in ANSI C63.10: 2013 and compliance standards. The test results of this report relate only to the tested sample (EUT) identified in this report. The test Report of full or partial shall not copy. Without written approval of Compliance Certification Services Inc. (Wugu Laboratory). Approved by: Shawn Wu Supervisor This document cannot be reproduced except in full, without prior written approval of the Company. 本報告未經本公司書面許可,不可部份複製。 Page: 2 / 91 Report No.: TMWK2311004152KR Rev.: 05 Revision History Rev. Issue Date Revisions Effect Page Revised By 00 January 23, 2024 Initial Issue ALL Peggy Tsai 01 February 1, 2024 See the following Note Rev. (01) P.4, 8, 9, 10, 11, 27, 28, 29, 43-64 Peggy Tsai 02 February 7, 2024 See the following Note Rev. (02) P.4, 8, 27, 28, 31-33, 46, 47, 52-55, 76, 77, Peggy Tsai 03 February 21, 2024 See the following Note Rev. (03) P.67, A-2 Peggy Tsai 04 March 1, 2024 See the following Note Rev. (04) P.5 Peggy Tsai 05 March 13, 2024 See the following Note Rev. (05) P.8, 9, A-1 Peggy Tsai Rev. (01): 1. Modify Date of Test in section 1.1. 2. Modify Instrument Calibration in section 1.6. 3. Modify Support and EUT Accessories Equipment in section 1.7. 4. Modify Test Summery in section 2. 5. Modify Output Power in section 5.3.4. 5. Modify Test Procedure in section 5.4.2. 6. Modify Radiation Data in section 5.6.4. Rev. (02): 1. Modify Date of Test in section 1.1. 2. Modify Instrument Calibration in section 1.6. 2. Modify Output Power Measurement in section 5.3.4. 3. Modify Power Spectral Density in section 5.4.4. 4. Modify Radiation Data in section 5.6.4. Rev. (03): 1. Modify Band Edge Test Data in section 5.6.4. 2. Modify Conducted Emission Set Up Photo. Rev. (04): 1. Modify Antenna Type in section 1.3. Rev. (05): 1. Modify Instrument Calibration in section 1.6. 2. Modify Radiation test photo in Appendix-A. This document cannot be reproduced except in full, without prior written approval of the Company. 本報告未經本公司書面許可,不可部份複製。 Page: 3 / 91 Report No.: TMWK2311004152KR Rev.: 05 Table of contents 1. GENERAL INFORMATION ............................................................................................... 4 1.1 EUT INFORMATION ......................................................................................................... 4 1.2 EUT CHANNEL INFORMATION ....................................................................................... 5 1.3 ANTENNA INFORMATION ............................................................................................... 5 1.4 MEASUREMENT UNCERTAINTY .................................................................................... 6 1.5 FACILITIES AND TEST LOCATION................................................................................. 7 1.6 INSTRUMENT CALIBRATION ......................................................................................... 8 1.7 SUPPORT AND EUT ACCESSORIES EQUIPMENT ..................................................... 10 1.8 TEST METHODOLOGY AND APPLIED STANDARDS .................................................. 10 2. TEST SUMMARY............................................................................................................ 11 3. DESCRIPTION OF TEST MODES .................................................................................. 12 3.1 THE WORST MODE OF OPERATING CONDITION ...................................................... 12 3.2 THE WORST MODE OF MEASUREMENT..................................................................... 13 4. EUT DUTY CYCLE ......................................................................................................... 14 5. TEST RESULT ................................................................................................................ 16 5.1 AC POWER LINE CONDUCTED EMISSION ..................................................…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Alex Lee(Manager)
[email protected]886-2-8919-1200Fax: 886-2-8919-1220

Technical Contact

Compliance Certification Services Inc. Wugu LabAngel Cheng
[email protected]886 2 2299 9720

No.11, Wugong 6th Rd., Wugu Dist. · New Taipei City · Tanzania

Non-Technical Contact

Compliance Certification Services Inc. Wugu LabAngel Cheng
[email protected]886 2 2299 9720

Test Firm

Compliance Certification Services Inc. Wugu Lab.Hank Lee
[email protected]886-2-2299-9720Fax: +886-2-2299-9721

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.41 GHz - 2.46 GHz588.80 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. This device supports bandwidths of 20MHz for WLAN. This device must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. End-user must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Good Way Technology Co., Ltd.

Wi-Fi & BLE M.2 Wireless Module - FCC ID SW8TM51010 - Good Way Technology Co., Ltd.
SW8TM51010

Wi-Fi & BLE M.2 Wireless Module

Jun 05, 2022

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Scene Button - FCC ID SW8TR1B100Z1S - Good Way Technology Co., Ltd.
SW8TR1B100Z1S

Scene Button

Jul 12, 2020

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
802.11b/g/n and Z-WAVE - FCC ID SW8ZGATE - Good Way Technology Co., Ltd.
SW8ZGATE

802.11b/g/n and Z-WAVE

Oct 08, 2014

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter
HP Wireless Streaming Connector - FCC ID SW8-WD9012R1 - Good Way Technology Co., Ltd.
SW8-WD9012R1

HP Wireless Streaming Connector

Sep 18, 2014

Equipment Class

DTS - Digital Transmission System
USB Z-Wave Dongle - FCC ID SW8WD60305 - Good Way Technology Co., Ltd.
SW8WD60305

USB Z-Wave Dongle

Jul 01, 2014

Equipment Class

DXX - Part 15 Low Power Communication Device Transmitter