
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
RF_160, Issue 02 Declaration of Authorization We Name: NETIS SYSTEMS CO., LTD. Address: 4F&5F R&D Building,Oriental Cyberport High-Tech Industrial Park, Nanshan City: Shenzhen Country: China Declare that: Name Representative of agent: Ms. Cathy Wang Agent Company name: BTL Inc. Address: No.3 Jinshagang 1st Road, Shixia, Dalang Town City: Dong Guan Country: China is authorized to apply for Certification and signing related documents of the following product(s), including 731 form(s): Product description: 720P HD Wireless IP Camera Type designation: SEC111, SEK204 Trademark: netis FCC ID: T58SEC111H on our behalf. Date: 2015-08-13 City: Shenzhen Name: Selena Bai Function: Director Signature: . Notes: (1): Required for FCC application (2): For FCC it must be the Grantee Code “owner” or the authorized agent.
Project No.: 1503C202A Page 2 of 14 Project No.: 1503C202A Page 3 of 14
label location
Project No.: 1503C202A Page 4 of 14 Project No.: 1503C202A Page 5 of 14 Project No.: 1503C202A Page 6 of 14 Project No.: 1503C202A Page 7 of 14 Project No.: 1503C202A Page 8 of 14 Project No.: 1503C202A Page 9 of 14 Project No.: 1503C202A Page 10 of 14 Project No.: 1503C202A Page 11 of 14 Project No.: 1503C202A Page 12 of 14 Project No.: 1503C202A Page 13 of 14 Project No.: 1503C202A Page 14 of 14
FCC RF EXPOSURE REPORT FCC ID: T58SEC111H Project No. : 1503C202A Equipment : 720P HD Wireless IP Camera Model : SEC111; SEK204 Applicant : NETIS SYSTEMS CO., LTD Address : 4F&5F R&D Building, Oriental Cyberport, High-Tech Industrial Park, Nanshan, Shenzhen, China. According: : FCC Guidelines for Human Exposure IEEE C95.1 BTL INC. No.3, Jinshagang 1st Road, Shixia, Dalang Town, Dongguan, China. TEL: +86-769-8318-3000 FAX: +86-769-8319-6000 MPE CALCULATION METHOD: Calculation Method of RF Safety Distance: where: S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Table for Filed Antenna Ant. Brand Model Name Antenna Type Connector Gain(dBi) 1 RF21S00002ADipole R-SMA 5.19 TEST RESULTS EUT: 720P HD Wireless IP Camera Model Name : SEC111; SEK204 Temperature: 25 °C Relative Humidity: 55 % Test Voltage : AC 120V/60Hz Test Mode : TX B MODE /CH01, CH06, CH11 Antenna Gain (dBi) Antenna Gain (numeric) Peak Output Power (dBm) Peak Output Power (mW) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Te s t Result 5.19 3.3037 16.12 40.9261 0.026912271 Complies 5.19 3.3037 16.67 46.4515 0.030545721 Complies 5.19 3.3037 16.41 43.7522 0.028770701 Complies EUT: 720P HD Wireless IP Camera Model Name : SEC111; SEK204 Temperature: 25 °C Relative Humidity: 55 % Test Voltage : AC 120V/60Hz Test Mode : TX G MODE /CH01, CH06, CH11 Antenna Gain (dBi) Antenna Gain (numeric) Peak Output Power (dBm) Peak Output Power (mW) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Te s t Result 5.19 3.3037 23.25 211.3489 0.138979381 Complies 5.19 3.3037 23.71 234.9633 0.154507791 Complies 5.19 3.3037 23.82 240.9905 0.158471211 Complies EUT: 720P HD Wireless IP Camera Model Name : SEC111; SEK204 Temperature: 25 °C Relative Humidity: 55 % Test Voltage : AC 120V/60Hz Test Mode : TX N-20M MODE_ Total /CH01, CH06, CH11 Antenna Gain (dBi) Antenna Gain (numeric) Peak Output Power (dBm) Peak Output Power (mW) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Te s t Result 5.19 3.3037 23.09 203.7042 0.13395236 1 Complies 5.19 3.3037 23.36 216.7704 0.14254447 1 Complies 5.19 3.3037 18.41 69.3426 0.04559848 1 Complies EUT: 720P HD Wireless IP Camera Model Name : SEC111; SEK204 Temperature: 25 °C Relative Humidity: 55 % Test Voltage : AC 120V/60Hz Test Mode : TX N-40M MODE_Total /CH03, CH06, CH09 Antenna Gain (dBi) Antenna Gain (numeric) Peak Output Power (dBm) Peak Output Power (mW) Power Density (S) (mW/cm 2 ) Limit of Power Density (S) (mW/cm 2 ) Te s t Result 5.19 3.3037 18.46 70.1455 0.04612649 1 Complies 5.19 3.3037 23.18 207.9697 0.13675725 1 Complies 5.19 3.3037 17.96 62.5173 0.04111027 1 Complies Note: the calculated distance is 20 cm.
Report No.: BTL-FCCP-1-1503C202A Page 1 of 127 FCC Radio Test Report FCC ID: T58SEC111H This report concerns (check one): Original Grant Class II Change Project No. : 1503C202A Equipment : 720P HD Wireless IP Camera / 4CH Wireless IP Camera & NVR Security Kit Model Name : SEC111; SEK204 Applicant : NETIS SYSTEMS CO., LTD Address : 4F&5F R&D Building, Oriental Cyberport, High-Tech Industrial Park, Nanshan, Shenzhen, China. Date of Receipt : Jul. 06, 2015 Date of Test : Jul. 06, 2015~Aug. 07, 2015 Issued Date : Aug. 10, 2015 Tested by : BTL Inc. T esting Engineer : ( Niklaus Lai) Technical Manager: (David Mao) Authorized Signatory : (Steven Lu) BTL INC. No.3, Jinshagang 1st Road, Shixia, Dalang Town, Dongguan, Guangdong, China. TEL: +86-769-8318-3000 FAX: +86-769-8319-6000 Report No.: BTL-FCCP-1-1503C202A Page 2 of 127 Declaration BTL represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C, or National Institute of Standards and Technology (NIST) of U.S.A. BTL's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. BTL shall have no liability for any declarations, inferences or generalizations drawn by the client or others from BTL issued reports. BTL’s report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and BTL-self, extracts from the test report shall not be reproduced except in full with BTL’s authorized written approval. BTL’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Report No.: BTL-FCCP-1-1503C202A Page 3 of 127 Table of Contents Page 1 . CERTIFICATION 6 2 . SUMMARY OF TEST RESULTS 7 2.1 TEST FACILITY 8 2.2 MEASUREMENT UNCERTAINTY 8 3 . GENERAL INFORMATION 9 3.1 GENERAL DESCRIPTION OF EUT 9 3.2 DESCRIPTION OF TEST MODES 10 3.3 TABLE OF PARAMETERS OF TEXT SOFTWARE SETTING 11 3.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 12 3.5 DESCRIPTION OF SUPPORT UNITS 12 4 . EMC EMISSION TEST 13 4.1 CONDUCTED EMISSION MEASUREMENT 13 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 13 4.1.2 TEST PROCEDURE 13 4.1.3 DEVIATION FROM TEST STANDARD 13 4.1.4 TEST SETUP 14 4.1.5 EUT OPERATING CONDITIONS 14 4.1.6 EUT TEST CONDITIONS 14 4.1.7 TEST RESULTS 14 4.2 RADIATED EMISSION MEASUREMENT 15 4.2.1 RADIATED EMISSION LIMITS 15 4.2.2 TEST PROCEDURE 16 4.2.3 DEVIATION FROM TEST STANDARD 16 4.2.4 TEST SETUP 17 4.2.5 EUT OPERATING CONDITIONS 18 4.2.6 EUT TEST CONDITIONS 18 4.2.7 TEST RESULTS (9KHZ TO 30MHZ) 19 4.2.8 TEST RESULTS (30MHZ TO 1000 MHZ) 19 4.2.9 TEST RESULTS (ABOVE 1000 MHZ) 19 5 . BANDWIDTH TEST 20 5.1 APPLIED PROCEDURES 20 5.1.1 TEST PROCEDURE 20 5.1.2 DEVIATION FROM STANDARD 20 5.1.3 TEST SETUP 20 5.1.4 EUT OPERATION CONDITIONS 20 5.1.5 EUT TEST CONDITIONS 20 5.1.6 TEST RESULTS 20 6 . MAXIMUM PEAK CONDUCTED OUTPUT POWER TEST 21 Report No.: BTL-FCCP-1-1503C202A Page 4 of 127 Table of Contents Page 6.1 APPLIED PROCEDURES / LIMIT 21 6.1.1 TEST PROCEDURE 21 6.1.2 DEVIATION FROM STANDARD 21 6.1.3 TEST SETUP 21 6.1.4 EUT OPERATION CONDITIONS 21 6.1.5 EUT TEST CONDITIONS 21 6.1.6 TEST RESULTS 21 7 . ANTENNA CONDUCTED SPURIOUS EMISSION 22 7.1 APPLIED PROCEDURES / LIMIT 22 7.1.1 TEST PROCEDURE 22 7.1.2 DEVIATION FROM STANDARD 22 7.1.3 TEST SETUP 22 7.1.4 EUT OPERATION CONDITIONS 22 7.1.5 EUT TEST CONDITIONS 22 7.1.6 TEST RESULTS 22 8 . POWER SPECTRAL DENSITY TEST 23 8.1 APPLIED PROCEDURES / LIMIT 23 8.1.1 TEST PROCEDURE 23 8.1.2 DEVIATION FROM STANDARD 23 8.1.3 TEST SETUP 23 8.1.4 EUT OPERATION CONDITIONS 23 8.1.5 EUT TEST CONDITIONS 23 8.1.6 TEST RESULTS 23 9 . MEASUREMENT INSTRUMENTS LIST 24 10 . EUT TEST PHOTO 26 ATTACHMENT A - CONDUCTED EMISSION 30 ATTACHMENT B - RADIATED EMISSION (9KHZ TO 30MHZ) 33 ATTACHMENT C - RADIATED EMISSION (30MHZ TO 1000MHZ) 35 ATTACHMENT D - RADIATED EMISSION (ABOVE 1000MHZ) 42 ATTACHMENT E - BANDWIDTH 91 ATTACHMENT F – MAXIMUM PEAK CONDUCTED OUTPUT POWER 100 ATTACHMENT G - ANTENNA CONDUCTED SPURIOUS EMISSION 102 ATTACHMENT H - POWER SPECTRAL DENSITY 119 Report No.: BTL-FCCP-1-1503C202A Page 5 of 127 REPORT ISSUED HISTORY Issued No. Description Issued Date BTL-FCCP-1-1503C202A Original Issue. Aug. 10, 2015 Report No.: BTL-FCCP-1-1503C202A Page 6 of 127 1. CERTIFICATION Equipment : 720P HD Wireless IP Camera / 4CH Wireless IP Camera & NVR Security Kit Brand Name : netis Model Name : SEC111, SEK204 Applicant : NETIS SYSTEMS CO., LTD Manufacturer : Shenzhen Netcore Industrial Ltd. Address : 4F&5F R&D Building, Oriental Cyberport, High-Tech Industrial Park, Nanshan, Shenzhen, China. Factory : Dongguan City Netcore Network Technology Co.,Ltd. Address : No.10-1,Sankeng Road,Qinghutou,Tangxia Town,Dongguan City Date of Test : Jul. 06, 2015~Aug. 07, 2015 Test Sample : Engineering Sample Standard(s) : FCC Part15, Subpart C: 2014 (15.247) / ANSI C63.10-2013 The above equipment has been tested and found compliance with the requirement of the relative standards by BTL Inc. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. BTL-FCCP-1-1503C202A) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of TAF according to the ISO-17025 quality assessment standard and technical sta…
Text truncated - open the document above for the full version.
Report No.: BTL-FCCP-1-1503C202A Page 26 of 127 10. EUT TEST PHOTO Conducted Measurement Photos Report No.: BTL-FCCP-1-1503C202A Page 27 of 127 Radiated Measurement Photos 9KHz to 30MHz Report No.: BTL-FCCP-1-1503C202A Page 28 of 127 Radiated Measurement Photos 30MHz to 1000MHz Report No.: BTL-FCCP-1-1503C202A Page 29 of 127 Radiated Measurement Photos Above 1000MHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 1 | 15C | 2.41 GHz - 2.46 GHz | 240.00 mW |

AX3000 Wireless Dual-Band WiFi6 Router
Equipment Class
DTS - Digital Transmission System
AX1800 Whole Home Mesh WiFi 6 System
Equipment Class
NII - Unlicensed National Information Infrastructure TX
AX1800 Dual-Band Wireless Router
Equipment Class
DTS - Digital Transmission System
AC1200 Wireless Dual Band Gigabit Router
Equipment Class
NII - Unlicensed National Information Infrastructure TX
AC1200 Dual Band WiFi Repeater
Equipment Class
DTS - Digital Transmission System