FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. NETIS SYSTEMS CO., LTD./
  3. T58WF2190R

T58WF2190RAC1200 Wireless Dual Band Adapter

NETIS SYSTEMS CO., LTD.
AC1200 Wireless Dual Band Adapter - FCC ID T58WF2190R - NETIS SYSTEMS CO., LTD.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Dec 04, 2013
Application Purpose
Original Equipment
Date of Application
Dec 04, 2013
Equipment Note
AC1200 Wireless Dual Band Adapter
Frequency Range
5775.00000000 - 5775.00000000
Company
NETIS SYSTEMS CO., LTD.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗
↗
↗
↗
↗
↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Cover Letter(s)

NETIS SYSTEMS CO., LTD Declaration of Authorization We Name: NETIS SYSTEMS CO., LTD Address: 4F&5F R&D Building Oriental Cyberport, High-Tech Industrial Park, Nanshan, Shenzhen, China Declare that: Name Representative of agent: Ms. Cathy Wang Agent Company name: Neutron Engineering, Inc. Address: No.3 Jinshagang 1 st Road, Shixia, Dalang Town City: Dong Guan Country: China is authorized to apply for Certification of the following product(s) and signing all the related documents including 731 forms: Product description: AC1200 Wireless Dual Band USB Adapt Type designation: WF2190 Trademark: netis on our behalf. Date: 2013-11-14 City: Shenzhen Name: Selena Bai Function: PD Assistant Signature:

Cover Letter(s)

CERTIFICATE OF COMPLIANCE Ref No.: NEI-FCCE-1-1307C140A Date of Issue: Nov. 13, 2013 Authorized under Declaration of Conformity according to 47 CFR, Part 2 and Part 15 of the FCC Rules. The product listed in follows was (were) tested in the Neutron EMC Laboratory to comply with the criteria limits Class B of conducted and radiated emissions of the Technical Standards FCC Part 15, Subpart B, established by the FCC, USA. Equipment AC1200 Wireless Dual Band USB Adapter Model Name WF2190 Brand Name netis Applicant NETIS SYSTEMS CO., LTD Address 4F&5F R&D Building, Oriental Cyberport, High-Tech Industrial Park, Nanshan, Shenzhen, China. Standard(s) FCC Part 15, Subpart B: 2012 ANSI C63.4 -2009 The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FCCE-1-1307C140A) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of TAF according to the ISO-17025 quality assessment standard and technical standard(s). The test data contained in the referenced test report relate only to the EUT sample and item(s) tested. Andy Chiu Authorized Signatory Neutron Engineering Inc. B1, No.37, Lane 365, Yang Guang St., NeiHu District 114., Taipei, Taiwan TEL:+886-2-2657-3299 FAX:+886-2-2657-3331

External Photos

Neutron Engineering Inc. Project No.: 1307C140A Page 2 of 8 Neutron Engineering Inc. Project No.: 1307C140A Page 3 of 8 Neutron Engineering Inc. Project No.: 1307C140A Page 4 of 8 Neutron Engineering Inc. Project No.: 1307C140A Page 5 of 8

ID Label/Location Info

label location

Internal Photos

Neutron Engineering Inc. Project No.: 1307C140A Page 6 of 8 Neutron Engineering Inc. Project No.: 1307C140A Page 7 of 8 Neutron Engineering Inc. Project No.: 1307C140A Page 8 of 8

RF Exposure Info

Report No.: NEI-FCC-SAR-1307C140A Page 57 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 58 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 59 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 60 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 61 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 62 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 63 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 64 of 101 Neutron Engineering Inc.

RF Exposure Info

Report No.: NEI-FCC-SAR-1307C140A Page 75 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 76 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 77 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 78 of 101 Neutron Engineering Inc. 5.(1) D2450V2 Dipole Calibration Certificate Report No.: NEI-FCC-SAR-1307C140A Page 79 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 80 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 81 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 82 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 83 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 84 of 101 Neutron Engineering Inc.

RF Exposure Info

Report No.: NEI-FCC-SAR-1307C140A Page 85 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 86 of 101 Neutron Engineering Inc. 5.(2) D5GHzV2 Dipole Calibration Certificate Report No.: NEI-FCC-SAR-1307C140A Page 87 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 88 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 89 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 90 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 91 of 101 Neutron Engineering Inc.

RF Exposure Info

Report No.: NEI-FCC-SAR-1307C140A Page 65 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 66 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 67 of 101 Neutron Engineering Inc. 4. Probe Calibration Certificate EX3DV4 Report No.: NEI-FCC-SAR-1307C140A Page 68 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 69 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 70 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 71 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 72 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 73 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 74 of 101 Neutron Engineering Inc.

RF Exposure Info

Report No.: NEI-FCC-SAR-1307C140A Page 92 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 93 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 94 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 95 of 101 Neutron Engineering Inc. 6. DAE4 Calibration Certificate Report No.: NEI-FCC-SAR-1307C140A Page 96 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 97 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 98 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 99 of 101 Neutron Engineering Inc. Report No.: NEI-FCC-SAR-1307C140A Page 100 of 101 Neutron Engineering Inc. 7. EUT Testing Position Bottom Left Right Top Front Back Report No.: NEI-FCC-SAR-1307C140A Page 101 of 101 Neutron Engineering Inc. 8. Test Configuration Test Position 1 Test Position 2

RF Exposure Info

Report No.: NEI-FCC-SAR-1307C140A Page 1 of 101 Neutron Engineering Inc. FCC SAR Test Report FCC ID: T58WF2190R Project No. : 1307C140A Equipment : AC1200 Wireless Dual Band USB Adapter Model Name : WF2190 Applicant : NETIS SYSTEMS CO., LTD Address : 4F&5F R&D Building, Oriental Cyberport, High-Tech Industrial Park, Nanshan, Shenzhen, China. Tested by:Neutron Engineering Inc. EMC Laboratory Date of Receipt: Nov. 20, 2013 Date of Test: Nov. 20, 2013~ Nov. 21, 2013 Date of Issue: Nov. 21, 2013 Testing Engineer : ( Super Jiang) Technical Manager : (Leo Hung) Authorized Signatory : (Steven Lu) Neutron Engineering Inc. No.3,Jinshagang 1st Road, ShiXia, Dalang Town, Dong Guan, China. TEL: 0769-8318-3000 FAX: 0769-8319-6000 Report No.: NEI-FCC-SAR-1307C140A Page 2 of 101 Neutron Engineering Inc. Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML), or National Institute of Standards and Technology (NIST) . Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutron shall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Report No.: NEI-FCC-SAR-1307C140A Page 3 of 101 Neutron Engineering Inc. Table of Contents Page 1 . GENERAL SUMMARY 6 2 . RF EMISSIONS MEASUREMENT 7 2.1 TEST FACILITY 7 2.2 MEASUREMENT UNCERTAINTY 7 3 . GENERAL INFORMATION 8 3.1 GENERAL DESCRIPTION OF EUT 8 3.2 THE MAXIMUM SAR 1G VALUES 10 3.3 LABORATORY ENVIRONMENT 10 3.4 MAIN TEST INSTRUMENTS 11 4 . SAR MEASUREMENTS SYSTEM CONFIGURATION 12 4.1 SAR MEASUREMENT SET-UP 12 4.2 DASY5 E-FIELD PROBE SYSTEM 13 5 . TISSUE-EQUIVALENT LIQUID 20 5.1 TISSUE-EQUIVALENT LIQUID INGREDIENTS 20 5.2 TISSUE-EQUIVALENT LIQUID PROPERTIES 20 6 . SYSTEM CHECK 21 6.1 DESCRIPTION OF SYSTEM CHECK 21 6.2 DESCRIPTION OF SYSTEM CHECK 22 7 . OPERATIONAL CONDITIONS DURING TEST 23 7.1 GENERAL DESCRIPTION OF TEST PROCEDURES 23 7.2 TEST POSITION 23 8 . TEST RESULT 24 8.1 CONDUCTED POWER RESULTS 24 8.2 SAR TEST RESULTS 46 APPENDIX 47 1. TEST LAYOUT 47 2. SYSTEM CHECK RESULTS 48 3. GRAPH RESULTS 51 4. PROBE CALIBRATION CERTIFICATE 67 5.(1) D2450V2 DIPOLE CALIBRATION CERTIFICATE 78 Report No.: NEI-FCC-SAR-1307C140A Page 4 of 101 Neutron Engineering Inc. Table of Contents Page 5.(2) D5GHZV2 DIPOLE CALIBRATION CERTIFICATE 86 6. DAE4 CALIBRATION CERTIFICATE 95 7. EUT TESTING POSITION 100 8. TEST CONFIGURATION 101 Report No.: NEI-FCC-SAR-1307C140A Page 5 of 101 Neutron Engineering Inc. REPORT ISSUED HISTORY Issued No. Description Issued Date NEI-FCC-SAR-1307C140A Original Issue. Nov. 21, 2013 - - - Report No.: NEI-FCC-SAR-1307C140A Page 6 of 101 Neutron Engineering Inc. 1. GENERAL SUMMARY Equipment AC1200 Wireless Dual Band USB Adapter Model Name netis Brand Name WF2190 Model Difference N/A Manufacturer Shenzhen Netcore Industrial Ltd. Address 4F&5F R&D Building, Oriental Cyberport, High-Tech Industrial Park, Nanshan, Shenzhen, China. Factory Dongguan City Netcore Network Technology Co., Ltd. Address No.10-1,Sankeng Road,Qinghutou,Tangxia Town, Dongguan City Standard(s) FCC 47CFR §2.1093 Radio frequency Radiation Exposure Evaluation: Portable Devices ANSI C95.1, 1999 Safety Levels with Respect to Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to 300 GHz.(IEEE Std C95.1-1999) IEEE 1528 2013: IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques KDB248227 D01 v01r02 SAR meas for 802 11 a b g v01r02: SAR Measurement Procedures for 802.11a/b/g Transmitters KDB 447498 D01 General RF Exposure Guidance v05r01: Mobile and Portable Device RF Exposure Procedures and Equipment Authorization Policies. 447498 D02 SAR Procedures for Dongle Xmtr v02 :SAR Measurement Procedures for USB Dongle Transmitters Tracking number: 400012 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FCC-SAR-1307C140A) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of TAF according to the ISO-17025 quality assessment standard and technical standard(s). Report No.: NEI-FCC-SAR-1307C140A Page 7 of 101 Neutron Engineering Inc. 2. RF EMISSIONS MEASUREMENT 2.1 TEST FACILITY The test facilities used to collect the test data in this report is SAR room at the location of No.3,Jinshagang 1st Road, ShiXia, Dalang Town, Dong Guan, China.523792 2.2 MEASUREMENT UNCERTAINTY Uncertainty Conponent Uncertainty Value Probability Distribution Divisor C i (1g) Standard Uncertainty ±1% V i or V eff Measurement System Probe Calibration (k=1) 5.9 Normal 1 1 5.9 ∞ Axial Isotropy 4.7 Rectangular 3 5.0 1.9 ∞ Hemispherical …

Text truncated - open the document above for the full version.

Test Report

Neutron Engineering Inc. Report No.: NEI-FCCP-1-1307C140A Page 1 of 145 FCC Radio Test Report FCC ID: T58WF2190R This report concerns (check one): Original Grant Class II Change Issued Date : Nov. 13, 2013 Project No. : 1307C140A Equipment : AC1200 Wireless Dual Band USB Adapter Model Name : WF2190 Applicant : NETIS SYSTEMS CO., LTD Address : 4F&5F R&D Building, Oriental Cyberport, High-Tech Industrial Park, Nanshan, Shenzhen, China. Tested by: Neutron Engineering Inc. EMC Laboratory Date of Receipt: Sep. 25, 2013 Date of Test: Sep. 25, 2013~ Nov. 12, 2013 Testing Engineer : ( David Mao) Technical Manager : (Leo Hung) Authorized Signatory: (Steven Lu) Neutron Engineering Inc. No.3,Jinshagang 1st Road, ShiXia, Dalang Town, Dong Guan, China. TEL: 0769-8318-3000 FAX: 0769-8319-6000 Neutron Engineering Inc. Report No.: NEI-FCCP-1-1307C140A Page 2 of 146 Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of R.O.C, or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutron shall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Neutron Engineering Inc. Report No.: NEI-FCCP-1-1307C140A Page 3 of 146 Table of Contents Page 1 . CERTIFICATION 6 2 . SUMMARY OF TEST RESULTS 7 2.1 TEST FACILITY 8 2.2 MEASUREMENT UNCERTAINTY 8 3 . GENERAL INFORMATION 9 3.1 GENERAL DESCRIPTION OF EUT 9 3.2 DESCRIPTION OF TEST MODES 11 3.3 TABLE OF PARAMETERS OF TEXT SOFTWARE SETTING 12 3.4 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 13 3.5 DESCRIPTION OF SUPPORT UNITS 14 4 . EMC EMISSION TEST 15 4.1 CONDUCTED EMISSION MEASUREMENT 15 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 15 4.1.2 MEASUREMENT INSTRUMENTS LIST AND SETTING 15 4.1.3 TEST PROCEDURE 16 4.1.4 DEVIATION FROM TEST STANDARD 16 4.1.5 TEST SETUP 16 4.1.6 EUT OPERATING CONDITIONS 16 4.1.7 TEST RESULTS 17 4.2 RADIATED EMISSION MEASUREMENT 20 4.2.1 RADIATED EMISSION LIMITS 20 4.2.2 MEASUREMENT INSTRUMENTS LIST ANS SETTING 21 4.2.3 TEST PROCEDURE 21 4.2.4 DEVIATION FROM TEST STANDARD 21 4.2.5 TEST SETUP 22 4.2.6 EUT OPERATING CONDITIONS 23 4.2.7 TEST RESULTS (BETWEEN 30 – 1000 MHZ) 25 4.2.8 TEST RESULTS (ABOVE 1000 MHZ) 32 5 . BANDWIDTH TEST 80 5.1 APPLIED PROCEDURES / LIMIT 80 5.1.1 MEASUREMENT INSTRUMENTS LIST 80 5.1.2 TEST PROCEDURE 80 5.1.3 DEVIATION FROM STANDARD 80 5.1.4 TEST SETUP 80 5.1.5 EUT OPERATION CONDITIONS 80 5.1.6 TEST RESULTS 81 6 . MAXIMUM OUTPUT POWER TEST 93 Neutron Engineering Inc. Report No.: NEI-FCCP-1-1307C140A Page 4 of 146 Table of Contents Page 6.1 APPLIED PROCEDURES / LIMIT 93 6.1.1 MEASUREMENT INSTRUMENTS LIST 93 6.1.2 TEST PROCEDURE 93 6.1.3 DEVIATION FROM STANDARD 93 6.1.4 TEST SETUP 93 6.1.5 EUT OPERATION CONDITIONS 93 6.1.6 TEST RESULTS 94 7 . ANTENNA CONDUCTED SPURIOUS EMISSION 97 7.1 APPLIED PROCEDURES / LIMIT 97 7.1.1 MEASUREMENT INSTRUMENTS LIST 97 7.1.2 TEST PROCEDURE 97 7.1.3 DEVIATION FROM STANDARD 97 7.1.4 TEST SETUP 97 7.1.5 EUT OPERATION CONDITIONS 97 7.1.6 TEST RESULTS 98 8 . POWER SPECTRAL DENSITY TEST 128 8.1 APPLIED PROCEDURES / LIMIT 128 8.1.1 MEASUREMENT INSTRUMENTS LIST 128 8.1.2 TEST PROCEDURE 128 8.1.3 DEVIATION FROM STANDARD 128 8.1.4 TEST SETUP 128 8.1.5 EUT OPERATION CONDITIONS 128 8.1.6 TEST RESULTS 129 9 . EUT TEST PHOTO 143 Neutron Engineering Inc. Report No.: NEI-FCCP-1-1307C140A Page 5 of 146 REPORT ISSUED HISTORY Issued No. Description Issued Date NEI-FCCP-1-1307C140A Original Issue. Nov. 13, 2013 - - - Neutron Engineering Inc. Report No.: NEI-FCCP-1-1307C140A Page 6 of 146 1. CERTIFICATION Equipment : AC1200 Wireless Dual Band USB Adapter Brand Name : netis Model Name : WF2190 Applicant : NETIS SYSTEMS CO., LTD Manufacture : Shenzhen Netcore Industrial Ltd. Address : 4F&5F R&D Building, Oriental Cyberport, High-Tech Industrial Park, Nanshan, Shenzhen, China. Factory : Dongguan City Netcore Network Technology Co., Ltd. Address No.10-1,Sankeng Road,Qinghutou,Tangxia Town, Dongguan City Date of Test : Sep. 25, 2013~ Nov. 12, 2013 Test Item : ENGINEERING SAMPLE Standard(s) : FCC Part15(2012), Subpart C(15.247) / ANSI C63.4-2009 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FCCP-1-1307C140A) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of TAF according to the ISO-17025 quality assessment standard and technical standard(s). Neutron Engineering Inc. Report No.: NEI-FCCP-1-1307C140A Page 7 of 146 2. SUMMARY OF TEST RESULTS Test procedures according to the technical standard(s): FCC Part15 (15.247) , Subpart C Standard(s) Section Test Item Judgment Rema…

Text truncated - open the document above for the full version.

Test Report

Neutron Engineering Inc. Report No.: NEI-FCCP-3-1307C140A Page 1 of 188 FCC Radio Test Report FCC ID: T58WF2190R This report concerns (check one): Original Grant Class II Change Issued Date : Nov. 13, 2013 Project No. : 1307C140A Equipment : AC1200 Wireless Dual Band USB Adapter Model Name : WF2190 Applicant : NETIS SYSTEMS CO., LTD Address : 4F&5F R&D Building, Oriental Cyberport, High-Tech Industrial Park, Nanshan, Shenzhen, China. Testing Engineer : (David Mao) Technical Manager : (Leo Hung) Authorized Signatory: (Steven Lu) Neutron Engineering Inc. No.3,Jinshagang 1st Road, ShiXia, Dalang Town, Dong Guan, China. TEL: 0769-8318-3000 FAX: 0769-8319-6000 Tested by: Neutron Engineering Inc. EMC Laboratory Date of Receipt: Sep. 25, 2013 Date of Test: Sep. 25, 2013~ Nov. 12, 2013 Neutron Engineering Inc. Report No.: NEI-FCCP-3-1307C140A Page 2 of 190 Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory (NML) of CHINA, or National Institute of Standards and Technology (NIST) of U.S.A. Neutron's reports apply only to the specific samples tested under conditions. It is manufacture’s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components. Neutron shall have no liability for any declarations, inferences o r generalizations drawn by the client or others from Neutron issued reports. Neutron’s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government. This report is the confidential property of the client. As a mutual protection to the clients, the public and Neutron-self, extracts from the test report shall not be reproduced except in full with Neutron’s authorized written approval. Neutron’s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements, and accredited by the conformity assessment authorities listed in this test report. Limitation For the use of the authority's logo is limited unless the Test Standard(s)/Scope(s)/Item(s) mentioned in this test report is (are) included in the conformity assessment authorities acceptance respective. Neutron Engineering Inc. Report No.: NEI-FCCP-3-1307C140A Page 3 of 190 Table of Contents Page 1 . CERTIFICATION 6 2 . SUMMARY OF TEST RESULTS 7 2.1 TEST FACILITY 8 2.2 MEASUREMENT UNCERTAINTY 8 3 . GENERAL INFORMATION 9 3.1 GENERAL DESCRIPTION OF EUT 9 3.2 DESCRIPTION OF TEST MODES 11 3.3 TABLE OF PARAMETERS OF TEXT SOFTWARE SETTING 12 3.4 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 13 3.5 DESCRIPTION OF SUPPORT UNITS 14 4 . EMC EMISSION TEST 15 4.1 CONDUCTED EMISSION MEASUREMENT 15 4.1.1 POWER LINE CONDUCTED EMISSION LIMITS 15 4.1.2 MEASUREMENT INSTRUMENTS LIST AND SETTING 15 4.1.3 TEST PROCEDURE 16 4.1.4 DEVIATION FROM TEST STANDARD 16 4.1.5 TEST SETUP 16 4.1.6 EUT OPERATING CONDITIONS 16 4.1.7 TEST RESULTS 17 4.2 RADIATED EMISSION MEASUREMENT 20 4.2.1 RADIATED EMISSION LIMITS 20 4.2.2 MEASUREMENT INSTRUMENTS LIST ANS SETTING 21 4.2.3 TEST PROCEDURE 21 4.2.4 DEVIATION FROM TEST STANDARD 21 4.2.5 TEST SETUP 22 4.2.6 EUT OPERATING CONDITIONS 24 4.2.7 TEST RESULTS (BELOW 30MHZ) 25 4.2.8 TEST RESULTS (BETWEEN 30 – 1000 MHZ) 26 4.2.9 TEST RESULTS (ABOVE 1000 MHZ) 39 5 . BANDWIDTH TEST 95 5.1 APPLIED PROCEDURES / LIMIT 95 5.1.1 MEASUREMENT INSTRUMENTS LIST 95 5.1.2 TEST PROCEDURE 95 5.1.3 DEVIATION FROM STANDARD 95 5.1.4 TEST SETUP 95 5.1.5 EUT OPERATION CONDITIONS 95 5.1.6 TEST RESULTS 96 Neutron Engineering Inc. Report No.: NEI-FCCP-3-1307C140A Page 4 of 190 Table of Contents Page 6 . MAXIMUM OUTPUT POWER TEST 107 6.1 APPLIED PROCEDURES / LIMIT 107 6.1.1 MEASUREMENT INSTRUMENTS LIST 107 6.1.2 TEST PROCEDURE 107 6.1.3 DEVIATION FROM STANDARD 107 6.1.4 TEST SETUP 107 6.1.5 EUT OPERATION CONDITIONS 107 6.1.6 TEST RESULTS 108 7 . ANTENNA CONDUCTED SPURIOUS EMISSION 114 7.1 APPLIED PROCEDURES / LIMIT 114 7.1.1 MEASUREMENT INSTRUMENTS LIST 114 7.1.2 TEST PROCEDURE 114 7.1.3 DEVIATION FROM STANDARD 114 7.1.4 TEST SETUP 115 7.1.5 EUT OPERATION CONDITIONS 115 7.1.6 TEST RESULTS 116 8 . POWER SPECTRAL DENSITY TEST 161 8.1 APPLIED PROCEDURES / LIMIT 161 8.1.1 MEASUREMENT INSTRUMENTS LIST 161 8.1.2 TEST PROCEDURE 161 8.1.3 DEVIATION FROM STANDARD 161 8.1.4 TEST SETUP 161 8.1.5 EUT OPERATION CONDITIONS 161 8.1.6 TEST RESULTS 162 9 . EUT TEST PHOTO 187 Neutron Engineering Inc. Report No.: NEI-FCCP-3-1307C140A Page 5 of 190 REPORT ISSUED HISTORY Issued No. Description Issued Date NEI-FCCP-3-1307C140A Original Issue. Nov. 13, 2013 Neutron Engineering Inc. Report No.: NEI-FCCP-3-1307C140A Page 6 of 190 1. CERTIFICATION Equipment : AC1200 Wireless Dual Band USB Adapter Brand Name : netis Model Name : WF2190 Applicant : NETIS SYSTEMS CO., LTD Manufacture : Shenzhen Netcore Industrial Ltd. Address : 4F&5F R&D Building, Oriental Cyberport, High-Tech Industrial Park, Nanshan, Shenzhen, China. Factory : Dongguan City Netcore Network Technology Co., Ltd. Address No.10-1,Sankeng Road,Qinghutou,Tangxia Town, Dongguan City Date of Test : Sep. 25, 2013~ Nov. 12, 2013 Test Item : ENGINEERING SAMPLE Standard(s) : FCC Part15, Subpart C(15.247) / ANSI C63.4-2009 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc. EMC Laboratory. The test data, data evaluation, and equipment configuration contained in our test report (Ref No. NEI-FCCP-3-1307C140A) were obtained utilizing the test procedures, test instruments, test sites that has been accredited by the Authority of TAF according to the ISO-17025 quality assessment standard and technical standard(s). Test result included in this report is only for the 5745~5825MHz part of the product. Neutron Engineering Inc. Report No.: NEI-FCCP-3-1307C140A Page 7 of 190 2. SUMMARY OF TEST RESULTS Test pr…

Text truncated - open the document above for the full version.

Test Setup Photos

Neutron Engineering Inc. Report No.: NEI-FCCP-3-1307C140A Page 187 of 190 9. EUT TEST PHOTO Conducted Measurement Photos Neutron Engineering Inc. Report No.: NEI-FCCP-3-1307C140A Page 188 of 190 Radiated Measurement Photos 9KHz~30MHz Neutron Engineering Inc. Report No.: NEI-FCCP-3-1307C140A Page 189 of 190 Radiated Measurement Photos 300MHz~1000MHz Neutron Engineering Inc. Report No.: NEI-FCCP-3-1307C140A Page 190 of 190 Radiated Measurement Photos Above 1000MHz

Contact Information

Applicant

Kinki Wang(Auditor)
[email protected]+86-755-86677078Fax: +86-755-86186779

Test Firm

BTL Inc.Daisy Dai
[email protected]008676983183000Fax: 0086 769 83196000

Technical Specifications

#Rule PartsFrequency RangePower Output
515C5.78 GHz - 5.78 GHz121.00 mW
Confidentiality
Long Term
Grant Notes
Power listed is conducted. SAR compliance for portable use conditions has been evaluated as described in this filing. The antenna(s) used for this transmitter must not transmit simultaneously with any other antenna or transmitter, except in accordance with FCC multi-transmitter product procedures. The highest reported SAR value for stand-alone and simultaneous transmission conditions is 0.18W/kg. This device has a 20 MHz, 40 MHz and 80 MHz bandwidth mode.

Other Applications from NETIS SYSTEMS CO., LTD.

AX3000 Wireless Dual-Band WiFi6 Router - FCC ID T58NX30R - NETIS SYSTEMS CO., LTD.
T58NX30R

AX3000 Wireless Dual-Band WiFi6 Router

Apr 20, 2023

Equipment Class

DTS - Digital Transmission System
AX1800 Whole Home Mesh WiFi 6 System - FCC ID T58M6R - NETIS SYSTEMS CO., LTD.
T58M6R

AX1800 Whole Home Mesh WiFi 6 System

Jul 03, 2022

Equipment Class

NII - Unlicensed National Information Infrastructure TX
AX1800 Dual-Band Wireless Router - FCC ID T58N6TR - NETIS SYSTEMS CO., LTD.
T58N6TR

AX1800 Dual-Band Wireless Router

Jun 05, 2022

Equipment Class

DTS - Digital Transmission System
AC1200 Wireless Dual Band Gigabit Router - FCC ID T58N3R - NETIS SYSTEMS CO., LTD.
T58N3R

AC1200 Wireless Dual Band Gigabit Router

Sep 26, 2021

Equipment Class

NII - Unlicensed National Information Infrastructure TX
AC1200 Dual Band WiFi Repeater - FCC ID T58E3R - NETIS SYSTEMS CO., LTD.
T58E3R

AC1200 Dual Band WiFi Repeater

Jul 17, 2021

Equipment Class

DTS - Digital Transmission System