Fluke Electronics
Vibration Meter - FCC ID T68-805FC - Fluke Electronics
Click to zoom

Application Details

Equipment Class
DSS - Part 15 Spread Spectrum Transmitter
Date of Grant
May 10, 2015
Application Purpose
Original Equipment
Date of Application
May 06, 2015
Equipment Note
Vibration Meter
Frequency Range
2402.00000000 - 2480.00000000
Company
Fluke Electronics
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗
↗

Attestation Statements

↗

Cover Letter(s)

↗

External Photos

↗

ID Label/Location Info

↗
↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

May 2012, Rev. 2, 12/14 © 2012-2014 Fluke Corporation. All rights reserved. S pecifications are subject to change without notice. All product names are trademarks of their respective companies. 805/805 FC Vibration Meter Users Manual LIMITED WARRANTY AND LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in ma terial and workmanship under normal use and service. The warranty period is one year and begins on the date of shipment. Parts, product repai rs, and services are warranted for 90 days. This warranty exte nds only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or t o any product which, in Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 da ys and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without inter ruption. Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authori ty to extend a greater or different warranty on behalf of Fluke. Warr anty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable internatio nal price. Fluke reserves the right to invoice Buyer for imp ortation costs of repair/replacement parts when product purchased in o ne country is submitted for repair in another country. Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase pr ice, free of charge repair, or replaceme nt of a defective product which is returned to a Fluke authoriz ed service center within the warranty period. To obtain warranty service, contact your nearest Fluke authorized service center to obtain return authorization information, th en send the product to that service center, with a description of the diffi culty, postage and insurance prepaid (FOB Destination). Fluke as sumes no risk for damage in transit. Following warranty repair, the product wi ll be returned to Buyer, transportation prepaid (FOB Destinatio n). If Fluke determines that failure was caused by neglect, misuse, contamin ation, alteration, accident, or abnormal condition of operation or handling, including overvoltage failures caused by use outside the product’s specified rating, or normal wear and tear of mechanical comp onents, Fluke will provide an estimate of repair costs and obtain authoriz ation before commencing the work. Following repair, the produ ct will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point). THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incide ntal or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this W arranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the va lidity or enforceability of any other provision. Fluke CorporationP.O. Box 9090 Everett, WA 98206-9090 U.S.A. Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands 11/99 To register your product online, visit register.fluke.com i Table of Contents Title Page Introduc tion .................................................................................................................. .. 1 How to Contac t Fluke .................................................................................................... 1 Safety Information .......................................................................................................... 2 Symbols ....................................................................................................................... .. 3 Accessori es ................................................................................................................... 3 Specificat ions ................................................................................................................ 3 Before You Start ............................................................................................................ 5 Unpack and In spect .................................................................................................. 5 Storage ..................................................................................................................... 5 Battery ...................................................................................................................... 5 Controls and Conn ections ......................................................................................... 6 Measurement Stat us LEDs ....................................................................................... 7 Power On .................................................................................................................. 8 Power Off .................................................................................................................. 8 How to Oper ate.............................................................................................................. 9 Navigati on ................................................................................................................. 9 Meter Configur ation ...........................…

Text truncated - open the document above for the full version.

Users Manual

PN 4333628 September 2013, Rev.3, 4/15 © 2013-2015 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. Radio Frequency Data for Class A 1 Introduction Information about radio frequency data is subject to change without notice. For up-to-date information, go to www.fluke.com. FCC/IC Information Class A digital device: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. Operation is subject to the two conditions that follow: (1) this device can not cause interference and (2) this device must accept any interference, including interference that can cause undesired operation of the device. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. Radio Frequency Data Class A 2 The term “IC” before the radio certification number only signifies the device meets Industry’s Canada technical specifications. Note Changes or modifications to the wireless 2.4 GHz radio not expressly approved by Fluke Corporation could void the user’s authority to operate the equipment. This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. The radio transmitter has been approved by Industry Canada to operate only with the antenna supplied. Use of any other antenna is strictly prohibited for use with this product. L'émetteur radio a été approuvé par Industrie Canada pour fonctionner uniquement avec l'antenne fournie. L'utilisation de toute autre antenne est strictement interdit d'utiliser ce produit. Radio Frequency Data Class A 3 MPE/SAR/RF Exposure Information MPE / SAR / RF Information sur l'Exposition This device was verified for RF exposure and found to comply with FCC OET-65 RF Exposure and RSS-102 requirements. This Product meets the SAR exemption based on its output power. Ce produit a été vérifiée pour l'exposition de puissance radio et jugé conforme aux normes FCC OET-65 et RSS-102 exigences. Sur la base de la puissance de sortie de la radio, ce produit répond aux taux d'absorption spécifique exemption. Country-Specific Information Brazil Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de estações do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário.” Mexico La operación de este equipo está sujeta a las siguientes dos condiciones: (1) es posible que este equipo o dispositivo no cause interferencia perjudicial y (2) este equipo o dispositivo debe aceptar cualquier interferencia, incluyendo la que pueda causar su operación no deseada. Radio Frequency Data Class A 4 S. Korea 당해 무선설비는 전파혼신 가능성이 있으므로 인명안전과 관련된 서비스는 할수 없음 Taiwan 低功率電波輻性電機管理辦法第十二條經型式認證合格之低功率射頻電機, 非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率或變更原設 計之特性及功能。第十四條低功率射頻電機之使用不得影響飛航安全及干擾 合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續 使用。前項合法通信,指依電信規定作業之無線電信。低功率射頻電機須忍 受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。 警告使用者:這是甲類的資訊產品,在居住的環境中使用時,可能會造成射 頻干擾,在這種情況下,使用者會被要求採取某些適當的對策。 Thailand อุปกรณ์ด้านการโทรคมนาคมนี ้ เป็นไปตามข้อก ํ าหนดด้านเทคนิค NTC

Users Manual

2450 MHz Small SMD Chip AntennaP/N 2450AT42B100 Ground Clearance Requirements Minimized. This antenna was designed for corner or end-mounting Detail Specification: 10/08/13 Page 1 of 4 Inmm No. L ±± 1 W ±± 2 L1 ±± 3 W1 ±± 4 T a ±± Johanson Technology, Inc. reserves the right to make design changes without notice. All sales are subject to Johanson Technology, Inc. terms and conditions. www.johansontechnology.com 4001 Calle Tecate • Camarillo, CA 93012 • TEL 805.389.1166 FAX 805.389.1821 Ver 2.1 2013 Johanson Technology, Inc. All Rights Reserved Note: It is recommended that the designer leave available slots for a "pi" (or shunt-series- shunt) network. The antenna matching network values here are used when antenna is mounted on Johanson's evaluation board. The matching values on clinet's PCB will be different, go to: johansontechnology.com/tuning and see how to obtain the new values. If you need further help, contact our RF Applications Eng Team at: www.johansontechnology.com/en/ask-a-technical-question.html We peform layout review as well as antenna tuning and characterization services. Go to page 2 for details. General Specifications -40 to +85°C 2W max. (CW) 2,000 50 Ω 9.5 dB min. -1.5 dBi typ. (XZ-V) 0 dBi typ. (XZ-V) 2400 - 2500 Mhz 0.0200.0120.500.30 0.0792.00+.004/-.008+0.1/-0.2 0.0080.20 0.50 0.0080.20 2.600.20 +5 ~ +35 °C,Humidity 45~75%RH -40 to +85°C "High Frequency Ceramic Solutions" 0.20 2.00 0.020 0.1020.008 0.008 0.197 0.079 5.00 NC NC NC 2450AT42B100 Mounting Considerations Part Number Frequency Range Peak Gain Average Gain Return Loss Impedance Reel Quanity Power Capacity Function Mechanical DimensionsTerminal Configuration Feeding Point Operating Temperature Recommended Storage Condition Storage Period a T W1 L1 W L     2.810.71 1 0.7 1.0 3 0.7 0.8 2 0.7 1 22 8 3.8 6 3.3 nH 1.5 nH Line width should be designed to match 50Ωcharacteristic impedance (Grounded Co‐Planar Waveguide), depending on PCB material and thickness. (The matching circuit and component values will be different on clients PCB layout, se notes below and go to page 2 for details). Top View Bottom View Side View Yellow area=Ground/Metal Clearance. The "0.82mm" dimmension is a min. requirement, if the designer can make this larger, the better radiation and gain will occur (i.e. 2.0 or 4.0mm) RF Via"stich" around antenna clearance and feed trace for best radiation 2450 MHz Small SMD Chip AntennaP/N 2450AT42B100 Detail Specification: 10/08/13 Page 2 of 4 Test Board: P/N: 2450AT42B100-EB1SMA (orderable item) To order, go to: www. johansontechnology.com/samplerequest Johanson Technology, Inc. reserves the right to make design changes without notice. All sales are subject to Johanson Technology, Inc. terms and conditions. www.johansontechnology.com 4001 Calle Tecate • Camarillo, CA 93012 • TEL 805.389.1166 FAX 805.389.1821 Ver 2.1 2013 Johanson Technology, Inc. All Rights Reserved Typical Electrical Characteristics (T=25 o C) We offer antenna layout review, tuning, and characterization services, go to: www.johansontechnology.com/ipcantennaservices for details and instructions Johanson Evaluation Board (orderable item) "High Frequency Ceramic Solutions" 3.86 40 20 8 (Units in mm) Return Loss (with matching) This 50ΩFeedline can be as short as needed, this lenth is just for reference to our EVB 2450 MHz Small SMD Chip AntennaP/N 2450AT42B100 Detail Specification: 10/08/13 Page 3 of 4 Johanson Technology, Inc. reserves the right to make design changes without notice. All sales are subject to Johanson Technology, Inc. terms and conditions. www.johansontechnology.com 4001 Calle Tecate • Camarillo, CA 93012 • TEL 805.389.1166 FAX 805.389.1821 Ver 2.1 2013 Johanson Technology, Inc. All Rights Reserved Typical Electrical Characteristics (T=25 o C) Radiation Patterns "High Frequency Ceramic Solutions" XY-V/XY-H 180 o 270 o 0 o 90 o X Z Y XY-cut scanning directio n XZ-V/XZ-H 180 o 270 o 0 o 90 o X Z Y XZ-cut scanning directio n YZ-V/YZ- H 180 o 270 o 0 o 90 o X Z Y YZ-cut scanning directio n XY cut @2.45GHz Vertical Horizontal XZ cut @2.45GHz Vertical Horizontal YZ cut @2.45GHz Vertical Horizontal 2450 MHz Small SMD Chip AntennaP/N 2450AT42B100 Detail Specification: 10/08/13 Page 4 of 4 Johanson Technology, Inc. reserves the right to make design changes without notice. All sales are subject to Johanson Technology, Inc. terms and conditions. www.johansontechnology.com 4001 Calle Tecate • Camarillo, CA 93012 • TEL 805.389.1166 FAX 805.389.1821 Ver 2.1 2013 Johanson Technology, Inc. All Rights Reserved www.johansontechnology.com/technical-notes/rohs-compliance.html RoHS Compliance MSL Info www.johansontechnology.com/technical-notes/msl-rating.html www.johansontechnology.com/ipcantennaservices "High Frequency Ceramic Solutions" Part Number Explanation P/N Suffix Packing Style Bulk (loose pieces)Suffix = Seg.2450AT42B100S T & RSuffix = Eeg. 2450AT42B100E Temperature:+5C to +35°CShelf Life: 18 months max. T & R (Reverse)Suffix = Reg. 2450AT42B100R (MOQ Applies) 100% TinSuffix = None eg. 2450AT42B100(S, E, R) Eval Board (1-port SMA antenna test boards) 2450AT42B100-EB1SMA (Page 2) More Details www.johansontechnology.com/ipc-pn-explained Storage Conditions and Shelf Life (On T&R or Bulk) Relative Humidity: 45 to 75% Packaging information Soldering Information Antenna layout and tuning techniques www.johansontechnology.com/ipcsoldering-profile www.johansontechnology.com/ipcpackaging.html Antenna layout review, tuning, and characterization services www.johansontechnology.com/tuning

Attestation Statements

Authority to Act as Agent Date: 4/10/2015 TUV Rhe inl and of N or th America, Inc. 1279 Quarry Ln., Ste. A Pleasanton, CA 94566 To Whom It May Concern: I appoint TUV-Rheinl and of N or th America Inc. t o act as o ur a gent i n the preparation of t his application for e qui pment c ertification. I certify that s ubmitted documents p roperly describe the device or system for w hi ch equipment c ertification is sought . I also certify tha t e ach unit m anufactured, imported or marketed, as defined in the FCC or I ndustry Canada’s regul ations w ill have a ffixed to it a label identical t o that submitted for approv al with thi s application. For i nstances w he re our a uthorized agent s igns t he application for c ertification on our behalf, I acknowledge t hat all responsibility for compl ying with the terms and condi tions for C ertification, as specified by TUV Rheinland Group, still r esides with Fluke Cor poration 6920 Seaway Blvd. Everett Washing ton USA For TCB application s, We certify that w e a re not subject t o denial of f ederal b enefits, that i nc ludes F CC benefits, pursuant t o Section 5301 of t he A nti-Drug A buse A ct of 1988, 21 U.S.C. 862. Further, n o party, as defined in 47 CFR 1. 2002 (b) , t o the application is subject t o denial o f f ederal benefits, tha t i nclud es FCC benefits. Tha nk you, Agency A greement Expiration Date: 4/ 10 /2016 By: _ James E Lenker ) Title: Product Compliance Engineer Telephone:425 446 5929 On behalf o f: Fluk e C or po ration

Cover Letter(s)

. Date: April 10 2105 Subject: Confide ntiality Request f or F CC I D: T 68-805FC IC ID : 6627A-805FC Pursuant t o FCC 47 CRF 0.457(d) and 0.459 and IC R SP-100, Section 10, the applic ant requests tha t a p art of the s ub ject F CC/IC application be held confidentia l. Type of Confidentiality Requested Exhibit Short Term Permanent Block Diagrams Short Term Permanent Internal Photos Short Term Permanent Operation Description/Theory of Operation Short Term Permanent Tune-Up Procedure Short Term Permanent Schematics Short Term Permanent User’s Manual Fluk e Cor po ration has spent substantial e ffor t i n developing thi s p roduct a nd it i s one of the first o f its k ind in industry. Having the s ubject i nfor mation easily available t o "competition" w ou ld negate t he advantage t hey have achieved by developing this prod uct. Not p rot ecting the details o f the design will r esult in financial h ardship. Permanent C onfidentiality: The applicant r equests the exhibits listed abov e as permanently confide ntial be p ermanently withheld from public r eview due to materials tha t contain trade s ecrets and prop rietary inf ormation not customaril y released to the public. Short-Term C onfidentiality: The applicant r equests the exhibits selected above as shor t t erm confide nt ial be withheld from public v iew for a period of 180 days from the date of t he G rant of Equipment A ut hor ization and prior t o marketing. Thi s is to avoi d prematur e r elease of s ensitive inf ormation prior t o marketing or r elease o f t he product t o the public. Applicant is also aware tha t t hey are responsible to notify TUV Rheinland in the event i nf or mation regarding the pr oduct o r t he product is m ade available to the public. TUV Rhe inl and will the n release the d ocuments listed above f or public d isclosure pursuant t o FCC Public Notice DA 04-1705. Sincerely, By: _ James Lenker Product Complianc e Engineer Fluke C or poration MS-0005105 Page 1 of 1 Version 2.0

External Photos

TUV Rheinland 1279 Quarry Lane, Ste. A, Pleasanton, CA 95466 Tel: (925) 249-9123, Fax: (925) 249-9124 EUT: Vibration Meter Model: 805FC Page 1 of 2 EMC / Rev 4/13/2015 FCCID: T68-8 05FC; IC: 6627A-8 05FC External Photos FCC ID: T68-805FC IC: 6627A-805FC EUT front view EUT Back side View TUV Rheinland 1279 Quarry Lane, Ste. A, Pleasanton, CA 95466 Tel: (925) 249-9123, Fax: (925) 249-9124 EUT: Vibration Meter Model: 805FC Page 2 of 2 EMC / Rev 4/13/2015 FCCID: T68-8 05FC; IC: 6627A-8 05FC EUT Connector side EUT top side view

ID Label/Location Info

Fluke-805 FC Labeling Page 1 Fluke-805 FC Labeling Page 2 US, CA, and Mexico China Brazil

Internal Photos

TUV Rheinland 1279 Quarry Lane, Ste. A, Pleasanton, CA 95466 Tel: (925) 249-9123, Fax: (925) 249-9124 EUT: Vibration Meter Model: 805FC Page 1 of 6 EMC / Rev 4/13/2015 FCCID: T68-805FC; IC: 6627A-805FC Internal Photos FCC ID: T68-805FC IC: 6627A-805FC EUT top cover open TUV Rheinland 1279 Quarry Lane, Ste. A, Pleasanton, CA 95466 Tel: (925) 249-9123, Fax: (925) 249-9124 EUT: Vibration Meter Model: 805FC Page 2 of 6 EMC / Rev 4/13/2015 FCCID: T68-805FC; IC: 6627A-805FC EUT Back cover open TUV Rheinland 1279 Quarry Lane, Ste. A, Pleasanton, CA 95466 Tel: (925) 249-9123, Fax: (925) 249-9124 EUT: Vibration Meter Model: 805FC Page 3 of 6 EMC / Rev 4/13/2015 FCCID: T68-805FC; IC: 6627A-805FC EUT Component side PCB Component side TUV Rheinland 1279 Quarry Lane, Ste. A, Pleasanton, CA 95466 Tel: (925) 249-9123, Fax: (925) 249-9124 EUT: Vibration Meter Model: 805FC Page 4 of 6 EMC / Rev 4/13/2015 FCCID: T68-805FC; IC: 6627A-805FC PCB back side TUV Rheinland 1279 Quarry Lane, Ste. A, Pleasanton, CA 95466 Tel: (925) 249-9123, Fax: (925) 249-9124 EUT: Vibration Meter Model: 805FC Page 5 of 6 EMC / Rev 4/13/2015 FCCID: T68-805FC; IC: 6627A-805FC Expanded view of PCB radio part TUV Rheinland 1279 Quarry Lane, Ste. A, Pleasanton, CA 95466 Tel: (925) 249-9123, Fax: (925) 249-9124 EUT: Vibration Meter Model: 805FC Page 6 of 6 EMC / Rev 4/13/2015 FCCID: T68-805FC; IC: 6627A-805FC Sensor PCB (No components on second side) Battery Compartment

RF Exposure Info

TUV Rheinland 1279 Quarry Lane, Ste. A, Pleasanton, CA 95466 Tel: (925) 249-9123, Fax: (925) 249-9124 EUT: Vibration Meter Model: 805FC Page 1 of 1 EMC / Rev 4/19/2015 FCCID: T68-805FC; IC: 6627A-805FC FCC ID: T68-805FC IC: 6627A-805FC RF Exposure Details are placed in Section 4.5 of Test Report# 31460300.001 Rev1

Test Report

Emissions Test Report EUT Name: Vibration Meter Model No.: 805FC CFR 47 Part 15.247:2014 Prepared for: Graham Don T Fluke Corporation. 6920 Seaway Blvd. Everett, WA 98203 U.S.A. Tel: (425) 446-5928 Prepared by: TUV Rheinland of North America, Inc. 1279 Quarry Lane, Ste. A Pleasanton, CA 94566 U.S.A. Tel: (925) 249-9123 Fax: (925) 249-9124 http://www.tuv.com/ Report/Issue Date: February 23, 2015 Report Number: 31460300.001 Project Number: 0000125067 Revision Number: 0 Report Number: 31460300.001 Page 2 of 67 EUT: Vibration Meter Model: 805FC Report Date: Feb 19, 2014 FCCID: T68-805FC; IC: 6627A-805FC Revisions Revision No. Date MM/DD/YYYY Reason for Change Author 0 02/23/2015 Original Document N/A 1 04/10/2015 Revised correct Ant gain on page 43 SK Report Number: 31460300.001 Page 3 of 67 EUT: Vibration Meter Model: 805FC Report Date: Feb 19, 2014 FCCID: T68-805FC; IC: 6627A-805FC Manufacturer: Statement of Compliance Fluke Corporation. 6920 Seaway Blvd. Everett, WA 98203 U.S.A. (425) 446-5928 Requester / Applicant: Graham Don T Name of Equipment: Vibration Meter Model No. 805FC Type of Equipment: Intentional Radiator Application of Regulations: CFR 47 Part 15.247:2014 Test Dates: Oct 30 – Nov 7, 2014 Guidance Document: Emissions: ANSI C63.10:2009 Test Methods: Emissions: ANSI C63.10:2009 The electromagnetic compatibility test and documented data described in this report has been performed and recorded by TUV Rheinland, in accordance with the standards and procedures listed herein. As the responsible authorized agent of the EMC laboratory, I hereby declare that the equipment described above has been shown to be compliant with the EMC requirements of the stated regulations and standards based on these results. If any special accessories and/or modifications were required for compliance, they are listed in the Executive Summary of this report. This report must not be used to claim product endorsement by A2LA. This report contains data that are not covered by A2LA accreditation. This report shall not be reproduced except in full, without the written authorization of TUV Rheinland of North America. Suresh Kondapalli February 19 , 2015 Conan Boyle February 23, 2015 Test Engineer Date Laboratory Signatory Date INDUSTRY CANADA Testing Certificate #3331.02 US5254 2932M-1 Index of Tables Report Number: 31460300.001 Page 4 of 67 EUT: Vibration Meter Model: 805FC Report Date: February 19, 2015 FCCID: T68-805FC; IC: 6627A-805FC 1 Executive Summary _______________________________________________________ 7 1.1 Scope______________________________________________________________________ 7 1.2 Purpose____________________________________________________________________ 7 Summary of Test Results ___________________________________________________________ 7 1.3 Special Accessories __________________________________________________________ 8 1.4 Equipment Modifications _____________________________________________________ 8 2 Laboratory Information ____________________________________________________ 9 2.1 Accreditations & Endorsements _______________________________________________ 9 2.1.1 US Federal Communications Commission _______________________________________________ 9 2.1.2 NIST / A2LA _____________________________________________________________________ 9 2.1.3 Canada – Industry Canada ___________________________________________________________ 9 2.1.4 Japan – VCCI _____________________________________________________________________ 9 2.1.5 Acceptance by Mutual Recognition Arrangement ________________________________________ 10 2.2 Test Facilities ______________________________________________________________ 10 2.2.1 Emission Test Facility _____________________________________________________________ 10 2.2.2 Immunity Test Facility _____________________________________________________________ 10 2.3 Measurement Uncertainty ___________________________________________________ 11 2.3.1 Sample Calculation – radiated & conducted emissions ____________________________________ 11 2.3.2 Measurement Uncertainty ___________________________________________________________ 11 2.4 Calibration Traceability _____________________________________________________ 12 3 Product Information ______________________________________________________ 13 3.1 Product Description ________________________________________________________ 13 3.2 Equipment Configuration ___________________________________________________ 13 3.3 Operating Mode ___________________________________________________________ 13 3.4 Duty Cycle: _______________________________________________________________ 13 3.5 Unique Antenna Connector __________________________________________________ 14 3.5.1 Results _________________________________________________________________________ 14 4 Emission Requirements – 2400 MHz to 2483.5 MHz Band _______________________ 15 4.1 Output Power Requirements _________________________________________________ 15 4.1.1 Test Method _____________________________________________________________________ 15 4.1.2 Results _________________________________________________________________________ 16 4.2 Occupied Bandwidth _______________________________________________________ 20 4.2.1 Test Method _____________________________________________________________________ 20 4.2.2 Results _________________________________________________________________________ 21 4.3 Hopping Frequency Requirements ____________________________________________ 25 4.3.1 Results _________________________________________________________________________ 25 4.4 Out of Band Emission requirements ___________________________________________ 34 4.4.1 Results _________________________________________________________________________ 34 4.5 Maximum RF Exposure _____________________________________________________ 41 Index of Tables Report Number: 31460300.001 Page 5 of 67 EUT: Vibration Meter Model: 805FC Report Date: February 19, 2015 FCCID: T68-805FC; IC: 6627A-805FC 4…

Text truncated - open the document above for the full version.

Test Setup Photos

TUV Rheinland 1279 Quarry Lane, Ste. A, Pleasanton, CA 95466 Tel: (925) 249-9123, Fax: (925) 249-9124 EUT: Vibration Meter Model: 805FC Page 1 of 6 EMC / Rev 4/15/2015 FCCID: T68-805FC; IC: 6627A-805FC Setup Photos FCC ID: T68-805FC IC: 6627A-805FC TUV Rheinland 1279 Quarry Lane, Ste. A, Pleasanton, CA 95466 Tel: (925) 249-9123, Fax: (925) 249-9124 EUT: Vibration Meter Model: 805FC Page 2 of 6 EMC / Rev 4/15/2015 FCCID: T68-805FC; IC: 6627A-805FC TUV Rheinland 1279 Quarry Lane, Ste. A, Pleasanton, CA 95466 Tel: (925) 249-9123, Fax: (925) 249-9124 EUT: Vibration Meter Model: 805FC Page 3 of 6 EMC / Rev 4/15/2015 FCCID: T68-805FC; IC: 6627A-805FC TUV Rheinland 1279 Quarry Lane, Ste. A, Pleasanton, CA 95466 Tel: (925) 249-9123, Fax: (925) 249-9124 EUT: Vibration Meter Model: 805FC Page 4 of 6 EMC / Rev 4/15/2015 FCCID: T68-805FC; IC: 6627A-805FC TUV Rheinland 1279 Quarry Lane, Ste. A, Pleasanton, CA 95466 Tel: (925) 249-9123, Fax: (925) 249-9124 EUT: Vibration Meter Model: 805FC Page 5 of 6 EMC / Rev 4/15/2015 FCCID: T68-805FC; IC: 6627A-805FC TUV Rheinland 1279 Quarry Lane, Ste. A, Pleasanton, CA 95466 Tel: (925) 249-9123, Fax: (925) 249-9124 EUT: Vibration Meter Model: 805FC Page 6 of 6 EMC / Rev 4/15/2015 FCCID: T68-805FC; IC: 6627A-805FC

Contact Information

Applicant

James E Lenker(Test Engineer)
[email protected]4254465929Fax: 425 446 6490

Test Firm

TUV Rheinland of North America Inc.David Spencer
[email protected](925) 249-9123 x2116Fax: 925 249 9124

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz600.00 µW
Confidentiality
Long Term
Grant Notes
The device must not be co-located or operating in conjunction with any other antenna or transmitter. End users must be provided with transmitter operation conditions for satisfying RF exposure compliance.

Other Applications from Fluke Electronics

USB1 FC WiFi-BLE Adapter - FCC ID T68-FWBA - Fluke Electronics
T68-FWBA

USB1 FC WiFi-BLE Adapter

Oct 27, 2015

Equipment Class

DTS - Digital Transmission System
TiX560, TiX520 - FCC ID T68-FT560 - Fluke Electronics
T68-FT560

TiX560, TiX520

May 14, 2015

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
T68-FBLE

Radio Module

Oct 27, 2013

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter
Gemini - FCC ID T68-FT400 - Fluke Electronics
T68-FT400

Gemini

Sep 29, 2013

Equipment Class

DTS - Digital Transmission System
Radio Module - FCC ID T68-FWCS - Fluke Electronics
T68-FWCS

Radio Module

Oct 07, 2012

Equipment Class

DTS - Digital Transmission System