
Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.
Archer C8 AC1750 Wireless Dual Band Gigabit Router REV3.0.1 1910011187 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks or registered trademarks of their respective holders. No part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from TP-LINK TECHNOLOGIES CO., LTD. Copyright © 2015 TP-LINK TECHNOLOGIES CO., LTD. All rights reserved. http://www.tp-link.com separation distance of at least 25 cm from all persons and must not be co FCC STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/ TV technician for help. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment. FCC RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. “To comply with FCC RF exposure compliance requirements, this grant is applicable to only Mobile Configurations. The antennas used for this transmitter must be installed to provide a - located or operating in conjunction with any other antenna or transmitter.” It is restricted in indoor Part 15E, Section 15.407 of the FCC Rules. environment only. This device meets all the other requirements specified in CE Mark Warning This is a class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. National Restrictions This device is intended for home and office use in all EU countries (and other countries following the EU directive 1999/5/EC) without any limitation except for the countries mentioned below: Country Restriction Reason/remark Bulgaria None General authorization required for outdoor use and public service France Outdoor use limited to 10 mW e.i.r.p. within the band 2454-2483.5 MHz Military Radiolocation use. Refarming of the 2.4 GHz band has been ongoing in recent years to allow current relaxed regulation. Full implementation planned 2012 Italy None If used outside of own premises, general authorization is required Luxembourg None General authorization required for network and service supply(not for spectrum) Norway Implemented This subsection does not apply for the geographical area within a radius of 20 km from the centre of Ny-Ålesund Russian Federation None Only for indoor applications 5150-5250 MHz Country Restriction Reason/remark Bulgaria Not implemented Planned Croatia License required Italy General authorization required if used outside own premises Luxembourg None General authorization required for network and service supply (not for spectrum) Russian Federation No info 5250-5350 MHz Country Restriction Reason/remark Bulgaria Not implemented Planned Croatia License required Italy General authorization required if used outside own premises Luxembourg None General authorization required for network and service supply (not for spectrum) Russian Federation No info 5470-5725 MHz Country Restriction Reason/remark Bulgaria Not implemented Planned France Relevant+ provisions for the implementation of DFS mechanism described in ETSI standard EN 301 893 V1.3.1 and subsequent versions Italy General authorization required if used outside own premises Luxembourg None General authorization required for network and service supply (not for spectrum) Russian Federation No info Turkey Not implemented Defence systems Note: Please don’t use the product outdoors in France. Canadian Compliance Statement This device complies with Industry Canada license-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause interference, and (2)This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage; ( 2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, meme si le brouillage est susceptible d’en compromettre le fonctionnement.) This radio transmitter (IC: 8853A-C8 …
Text truncated - open the document above for the full version.
(1) EUT Photo (2) EUT Photo (3) EUT Photo (4) EUT Photo (5) EUT Photo (6) EUT Photo (7) EUT Photo (8) EUT Photo (9) EUT Photo (10) EUT Photo
C B A 12 C 345678 B E D D A 9 料号: 12345 E 6789 Archer C8(UN) 2.0产品规格丝印 A2 0.175哑面细砂纹PC+3M467 排架221 Archer C8(UN) 2.0 吴佳 2015-6-11 更新机型名称 Pantone 431C TP标准米白色2号 Pantone 431C Pantone Cool Gray 2U 供应商来料示意图(文字转曲) 单色示意图 平装供货 边距:3mm 跳距:3mm MAC地址、Wireless Password/PIN、S/N码及SSID均由工厂打 印至23*5mm空白标贴(7210500097)后粘贴。 154.5*14,2R; 0-30mm,公差±0.1mm,大于30mm,公差±0.2mm This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Default Access: Model: Power: IC:8853A - C8 FCC ID:TE7C8V2 AC1750 Wireless Dual Band Gigabit Router Mac Address Serial NumberWireless Password/PIN SSID Pantone 431C Pantone Cool Gray 2U TP标准米白色2号 注:请加覆灰色底防止透光,覆厚一点 效果图 转曲图 单色示意 SSID编码规则 2.4G:TP-LINK_XXXX 5G:TP-LINK_XXXX_5G (XXXX均为LAN MAC地址后4位) Label Location
(1) EUT Photo (2) EUT Photo (3) EUT Photo (4) EUT Photo (5) EUT Photo (6) EUT Photo (7) EUT Photo (8) EUT Photo
RF Exposure Evaluation Declaration Product Name : AC1750 Wireless Dual Band Gigabit Router Model No. : Archer C8 FCC ID : TE7C8V2 Applicant : TP-LINK TECHNOLOGIES CO., LTD. Address : Building 24 (floors 1,3,4,5) and 28 (floors1-4) Central Science and Technology Park,Shennan Rd, Nanshan,Shenzhen,China Date of Receipt : Jul. 10, 2015 Issued Date : Dec. 01, 2015 Report No. : 1570321R-RF-US-P20V01 Report Version : V1.3 The test results relate only to the samples tested. The test results shown in the test report are traceable to the national/international standard through the calibration of the equipment and evaluated measurement uncertainty herein. This report must not be used to claim product endorsement by any agency of the government. The test report shall not be reproduced without the written approval of QuieTek Corporation. Report No: 1570321R-RF-US-P20V01 Page: 2 of 9 Test Report Certification Issued Date : Dec. 01, 2015 Report No. : 1570321R-RF-US-P20V01 Product Name : AC1750 Wireless Dual Band Gigabit Router Applicant : TP-LINK TECHNOLOGIES CO., LTD. Address : Building 24 (floors 1,3,4,5) and 28 (floors1-4) Central Science and Technology Park,Shennan Rd, Nanshan, Shenzhen,China Manufacturer : TP-LINK TECHNOLOGIES CO., LTD Address : Building 24 (floors 1,3,4,5) and 28 (floors1-4) Central Science and Technology Park,Shennan Rd, Nanshan, Shenzhen,China Model No. : Archer C8 FCC ID : TE7C8V2 EUT Voltage : DC 12V/3.3A Brand Name : TP-LINK Applicable Standard : KDB 447498D01V05V02 FCC Part1.1310(b) RSS-102: Issue 5, March, 2015 Test Result : Complied Performed Location : Suzhou EMC Laboratory No.99 Hongye Rd., Suzhou Industrial Park, Suzhou, 215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 FCC Registration Number: 800392; IC Lab Code: 4075B Documented By : Reviewed By : Approved By : Report No: 1570321R-RF-US-P20V01 Page: 3 of 9 Laboratory Information We, QuieTek Corporation, are an independent EMC and safety consultancy that was established the whole facility in our laboratories. The test facility has been accredited/accepted(audited or listed) by the following related bodies in compliance with ISO 17025, EN 45001 and specified testing scope: The related certificate for our laboratories about the test site and management system can be downloaded from QuieTek Corporation’s Web Site :http://www.quietek.com/tw/ctg/cts/accreditations.htm The address and introduction of QuieTek Corporation’s laboratories can be founded in our Web site : http://www.quietek.com/ If you have any comments, Please don’t hesitate to contact us. Our contact information is as below: HsinChu Testing Laboratory : No.75-2, 3rd Lin, Wangye Keng, Yonghxing Tsuen, Qionglin Shiang, Hsinchu County 307, Taiwan, R.O.C. TEL:+886-3-592-8858 / FAX:+886-3-592-8859 E-Mail : [email protected] LinKou Testing Laboratory : No.5-22, Ruishukeng, Linkou Dist., New Taipei City 24451, Taiwan, R.O.C. TEL : 886-2-8601-3788 / FAX : 886-2-8601-3789 E-Mail : [email protected] Suzhou Testing Laboratory : No.99 Hongye Rd., Suzhou Industrial Park, Suzhou,215006, Jiangsu, China TEL : +86-512-6251-5088 / FAX : 86-512-6251-5098 E-Mail : [email protected] Taiwan R.O.C. :BSMI, NCC, TAF USA :FCC Japan :VCCI China :CNAS Report No: 1570321R-RF-US-P20V01 Page: 4 of 9 History of This Test Report REPORT NO. VERSION DESCRIPTION ISSUED DATE 1570321R-RF-US-P20V01 V1.0 Initial Issued Report Nov. 26, 2015 1570321R-RF-US-P20V01 V1.1 Add the evaluation for simultaneous transmission Nov. 28, 2015 1570321R-RF-US-P20V01 V1.2 Add the evaluation for safety distance Nov. 30, 2015 1570321R-RF-US-P20V01 V1.3 Modify safety distance in calculation Dec. 01, 2015 Report No: 1570321R-RF-US-P20V01 Page: 5 of 9 1. RF Exposure Evaluation 1.1. Limits According to FCC 1.1310: The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio frequency (RF) radiation as specified in 1.1307(b) LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) Frequency Range (MHz) Electric Field Strength (V/m) Magnetic Field Strength (A/m) Power Density (mW/cm2) Average Time (Minutes) (A) Limits for Occupational/ Control Exposures 300-1500 -- -- F/300 6 1500-100,000 -- -- 5 6 (B) Limits for General Population/ Uncontrolled Exposures 300-1500 -- -- F/1500 6 1500-100,000 -- -- 1 30 F= Frequency in MHz Friis Formula Friis transmission formula: Pd = (Pout*G)/(4*pi*r2) Where Pd = power density in mW/cm2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total power input to the antenna, through the calculation, we will know the distance r where the MPE limit is reached. Report No: 1570321R-RF-US-P20V01 Page: 6 of 9 1.2. Test Procedure Software provided by client enabled the EUT to transmit and receive data at lowest, middle and highest channel individually. The temperature and related humidity: 18°Cand 78% RH. 1.3. Test Result of RF Exposure Evaluation Product : AC1750 Wireless Dual Band Gigabit Router Test Item : RF Exposure Evaluation Test Site : AC-6 z Antenna Gain: Antenna List Antenna Type Product NumberPeak Gain Directional gain for Beamforming Directional gain for CDD Dipole Antenna Dipole 3101500451 2.1dBi for 2.4G N/A 6.87dBi Dipole Antenna Dipole 3101500451 1.7dBi for 5G 6.47dBi 6.47dBi Note: 1: The EUT has three antennas, and each port has same gain, they transmit signals are correlated with each other. (1) 5G Directional gain for Beamforming Calculation is: Directional gain = G ANT + 10 log(NANT/NSS) dBi≈6.47dBi. (2) 2.4G Directional gain for CDD Calculation is: a. For power measurements Array Gain = 0 dB (i.e., no array gain) for NANT ≤ 4; Directional gain = G ANT + Array Gain=2.1dBi b. For power spectral density (PSD) measurements Directional gain = G ANT + Array Gain≈6.87dBi 5G Directional gain for CDD Calculation is: c. For power…
Text truncated - open the document above for the full version.
Test Report FCC Part15 Subpart E Product Name : AC1750 Wireless Dual Band Gigabit Router Model No. : Archer C8 FCC ID : TE7C8V2 Applicant : TP-LINK TECHNOLOGIES CO., LTD. Address : Building 24 (floors 1,3,4,5) and 28 (floors1-4) Central Science and Technology Park,Shennan Rd, Nanshan, Shenzhen, China Date of Receipt : Jul. 10, 2015 Test Date : Jul. 10, 2015~ Nov. 28, 2015 Issued Date : Nov. 30, 2015 Report No. : 1570321R-RF-US-P09V01 Report Version : V2.1 The test results relate only to the samples tested. The test results shown in the test report are traceable to the national/international standard through the calibration of the equipment and evaluated measurement uncertainty herein. This report must not be used to claim product endorsement by CNAS,TAF any agency of the government. The test report shall not be reproduced without the written approval of QuieTek Corporation. Report No: 1570321R-RF-US-P09V01 Page: 2 of 166 Test Report Certification Issued Date : Nov. 30, 2015 Report No. : 1570321R-RF-US-P09V01 Product Name : AC1750 Wireless Dual Band Gigabit Router Applicant : TP-LINK TECHNOLOGIES CO., LTD. Address : Building 24 (floors 1,3,4,5) and 28 (floors1-4) Central Science and Technology Park, Shennan Rd, Nanshan, Shenzhen, China Manufacturer : TP-LINK TECHNOLOGIES CO., LTD. Address : Building 24 (floors 1,3,4,5) and 28 (floors1-4) Central Science and Technology Park, Shennan Rd, Nanshan, Shenzhen, China Model No. : Archer C8 FCC ID : TE7C8V2 EUT Voltage : DC 12V/3.3A Brand Name : TP-LINK Applicable Standard : FCC CFR Title 47 Part 15 Subpart E: 2015 ANSI C63.4:2014; ANSI C63.10:2013; 789033 D02 General UNII Test Procedures New Rules v01 Test Result : Complied Performed Location : Quietek Corporation - Suzhou EMC Laboratory No.99 Hongye Rd., Suzhou Industrial Park, Suzhou,215006, Jiangsu, China TEL: +86-512-6251-5088 / FAX: +86-512-6251-5098 FCC Registration Number: 800392; Documented By : Reviewed By : Approved By : Report No: 1570321R-RF-US-P09V01 Page: 3 of 166 Laboratory Information We, QuieTek Corporation, are an independent EMC and safety consultancy that was established the whole facility in our laboratories. The test facility has been accredited/accepted(audited or listed) by the following related bodies in compliance with ISO 17025, EN 45001 and specified testing scope: The related certificate for our laboratories about the test site and management system can be downloaded from QuieTek Corporation’s Web Site :http://www.quietek.com/tw/ctg/cts/accreditations.htm The address and introduction of QuieTek Corporation’s laboratories can be founded in our Web site : http://www.quietek.com/ If you have any comments, Please don’t hesitate to contact us. Our contact information is as below: HsinChu Testing Laboratory : No.75-2, 3rd Lin, Wangye Keng, Yonghxing Tsuen, Qionglin Shiang, Hsinchu County 307, Taiwan, R.O.C. TEL:+886-3-592-8858 / FAX:+886-3-592-8859 E-Mail : [email protected] LinKou Testing Laboratory : No.5-22, Ruishukeng, Linkou Dist., New Taipei City 24451, Taiwan, R.O.C. TEL : 886-2-8601-3788 / FAX : 886-2-8601-3789 E-Mail : [email protected] Suzhou Testing Laboratory : No.99 Hongye Rd., Suzhou Industrial Park, Suzhou,215006, Jiangsu, China TEL : +86-512-6251-5088 / FAX : 86-512-6251-5098 E-Mail : [email protected] Taiwan R.O.C. : BSMI, NCC, TAF USA : FCC Japan : VCCI China : CNAS Report No: 1570321R-RF-US-P09V01 Page: 4 of 166 TABLE OF CONTENTS Description Page 1. General Information .................................................................................................................... 8 1.1. EUT Description ...................................................................................................................... 8 1.2. Mode of Operation ................................................................................................................ 17 1.3. Tested System Details ........................................................................................................... 18 1.4. Configuration of Tested System ............................................................................................ 19 1.5. EUT Exercise Software ......................................................................................................... 21 2. Technical Test ............................................................................................................................ 22 2.1. Summary of Test Result ........................................................................................................ 22 2.2. Test Environment .................................................................................................................. 23 3. Conducted Emission ................................................................................................................. 24 3.1. Test Equipment ..................................................................................................................... 24 3.2. Test Setup ............................................................................................................................. 24 3.3. Limit ....................................................................................................................................... 25 3.4. Test Procedure ...................................................................................................................... 25 3.5. Uncertainty ............................................................................................................................ 25 3.6. Test Result ............................................................................................................................ 26 4. Radiated Emission .................................................................................................................... 28 4.1. Test Equipment ..................................................................................................................... 28 4.2. Test Se…
Text truncated - open the document above for the full version.
Test Setup Photograph Test Mode: Mode 1 Description: Front View of Conducted emission Test Setup Test Mode: Mode 1 Description: Side View of Conducted emission Test Setup Description: Radiated Emission Test Setup for Below 30MHz Description: Radiated Emission Test Setup for Below 1GHz Description: Radiated Emission Test Setup for 1~18GHz Description: Radiated Emission Test Setup for 18~40GHz
| # | Rule Parts | Frequency Range | Power Output |
|---|---|---|---|
| 3 | 15E | 5.21 GHz - 5.21 GHz | 48.00 mW |

AC750 Wi-Fi Range Extender, AC1200 Wi-Fi Range Extender
Equipment Class
DTS - Digital Transmission System
AX1800 Dual-Band Wi-Fi 6 Router
Equipment Class
DTS - Digital Transmission System
AX1800 Wireless Dual-Band Gigabit Ceiling Mount Access Point
Equipment Class
NII - Unlicensed National Information Infrastructure TX
Kasa Smart Wi-Fi Power Strip, 3-Outlet
Equipment Class
DTS - Digital Transmission System
AC1750 Wi-Fi Range Extender, AC1900 MU-MIMO Wi-Fi Range Extender
Equipment Class
DTS - Digital Transmission System