FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. TP-Link Technologies Co., Ltd./
  3. TE7TDW8961NDV2

TE7TDW8961NDV2300Mbps Wireless N ADSL2+ Modem Router Model No. : TD-W8961ND

TP-Link Technologies Co., Ltd.
300Mbps Wireless N ADSL2+ Modem Router Model No. : TD-W8961ND - FCC ID TE7TDW8961NDV2 - TP-Link Technologies Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 06, 2012
Application Purpose
Original Equipment
Date of Application
Mar 06, 2012
Equipment Note
300Mbps Wireless N ADSL2+ Modem Router Model No. : TD-W8961ND
Frequency Range
2422.00000000 - 2452.00000000
Company
TP-Link Technologies Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

TD-W8961ND 300Mbps Wireless N ADSL2+ Modem Router Rev: 2.0.1 1910010531 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks or registered trademarks of their respective holders. No part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from TP-LINK TECHNOLOGIES CO., LTD. Copyright © 2012 TP-LINK TECHNOLOGIES CO., LTD. All rights reserved. http://www.tp-link.com FCC STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to pro-vide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not in-stalled and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/ TV technician for help. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: The manufacturer is not responsible for any radio or tv interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment. FCC RF Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. “To comply with FCC RF exposure compliance requirements, this grant is applicable to only Mobile Configurations. The antennas used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.” CE Mark Warning This is a class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. National Restrictions This device is intended for home and office use in all EU countries (and other countries following the EU directive 1999/5/EC) without any limitation except for the countries mentioned below: Country Restriction Reason/remark Bulgaria None General authorization required for outdoor use and public service France Outdoor use limited to 10 mW e.i.r.p. within the band 2454-2483.5 MHz Military Radiolocation use. Refarming of the 2.4 GHz band has been ongoing in recent years to allow current relaxed regulation. Full implementation planned 2012 Italy None If used outside of own premises, general authorization is required Luxembourg None General authorization required for network and service supply(not for spectrum) Norway Implemented This subsection does not apply for the geographical area within a radius of 20 km from the centre of Ny-Ålesund Russian Federation None Only for indoor applications Note: Please don’t use the product outdoors in France. This device has been designed to operate with the antennas listed below, and having a maximum gain of 3 dBi. Antennas not included in this list or having a gain greater than 3 dBi are strictly prohibited for use with this device. The required antenna impedance is 50 ohms. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that permitted for successful communication.” Industry Canada Statement: This device complies with RSS-210 of the Industry Canada Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2)This device must accept any interference received, including interference that may cause undesired operation. IMPORTANT NOTE: Radiation Exposure Statement: This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Ce dispositif est conforme à la norme CNR-210 d’Industrie Canada applicable aux appareils radio exempts de licence. Son fonctionnement est sujet aux deux conditions suivantes: (1) Le dispositif ne doit pas produire de brouillage préjudiciable, et (2) Ce dispositif doit accepter tout brouillage reçu,y compris un brouillage susceptible de provoquer un fonctionnement indésirable. NOTE IMPORTANTE: Déclaration d’exposition aux radiations: Cet équipement est conforme aux limites d’exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Korea Warning Statements: 당해 무선설비는 운용중 전파혼신 가능성이 있음. NCC Notice: 經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功 率或變更原設計之特性及功能。 低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應…

Text truncated - open the document above for the full version.

Cover Letter(s)

AGENCY AUTHORIZATION LETTER FCC ID:TE7TDW8961NDV2 Date: 2012-3-2 To whom it may concern: We, the undersigned, hereby authorize Audix Technology (Shenzhen) Co., Ltd (No. 6, Ke Feng Rd., 52 Block, Shenzhen Science & Industrial Park,Nantou,Shenzhen, Guangdong, China) to act on our behalf, as our agent, in the following matters related to the FCC approval of our products: report submittal, related correspondence, the signing of all documents relating to these matters, and any other lawful activity necessary to obtain such certification. Any act carried out by Audix within the scope of this authorization shall have the same effects as our own. This authorization shall expire 6 months form original date. If you have any Questions regarding the authorization, please don’t hesitate to contact us. Thank you. Sincerely, Name of authorized signer: Yongquan Wang Title of authorized signer: Product Dept. Manager Company Name: TP-LINK Technologies Co., Ltd. Tel: 86-755-26525554 Fax: 86-755-26508930 Web site: WWW.TP-LINK.COM E-mail: [email protected]

Cover Letter(s)

Date: 2012-3-2 Federal Communications Commission Authorization and Evaluation Division FCC ID: TE7WTDW8961NDV2 Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying this application as outlined below: 1. Block diagram 2. Schematics 3. Operation Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might to harmful to the applicant and provide unjustified benefits to its competitors. The applicant understands that pursuant to Rule 0.457, disclosure of this application and all accompanying documentation will not be made before the date of the grant for this application. Sincerely, Name of authorized signer: Yongquan Wang Title of authorized signer: Product Dept. Manager Company Name: TP-LINK Technologies Co., Ltd. Tel: 86-755-26525554 Fax: 86-755-26508930 Web site: WWW.TP-LINK.COM E-mail: [email protected]

Cover Letter(s)

Attestation for FCC Declaration of Conformity FCC ID: TE7TDW8961NDV2 Date: 2012-3-2 Please be notified that we, the undersigned, TP-LINK TECHNOLOGIES CO., LTD declare that the product bears the above FCC ID is also complying with the requirements of FCC DoC. The test report number for FCC DoC is EM-F1010159, with is issued by an accredited lab, Audix Technology Corporation, EMC Department located at No. 53-11, Tin-Fu Tsun, Lin-Kou , Taipei Hsien , Taiwan. Which has been accredited in accordance to all of the requirements of 47CFR 2.948(d) and (e) of the FCC rules and KDB349827. Sincerely, Name of authorized signer: Yongquan Wang Title of authorized signer: Product Dept. Manager Company Name: TP-LINK Technologies Co., Ltd. Tel: 86-755-26525554 Fax: 86-755-26508930 Web site: WWW.TP-LINK.COM E-mail: [email protected]

Cover Letter(s)

TP-LINK TECHNOLIGIES CO., LTD Building 24 (floors 1,3,4,5) and 28 (floors1-4) Central Science and Technology Park,Shennan Rd, Nanshan, Shenzhen,China Tel: 86-755-26525554 Request for Supercede TO: Federal Communication Commission Please kindly be notified that we, (TP-LINK TECHNOLIGIES CO., LTD ) herein request to supercede the FCC ID: TE7TDW8961NDV2 for the following reason: 1. Product’s label need to be changed for we refreshed it 2. External photo need to be changed for the label has been refreshed Please kindly permit the supercede. Thank you. Sincerely, (Signature) Name / Title: Name of authorized signer: Yongquan Wang Title of authorized signer: Product Dept. Manager Tel: 86-755-26525554 Fax: 86-755-26508930 Email: [email protected]

External Photos

R AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:TE7TDW8961NDV2 page Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F12029 14-1 14. PHOTOS OF THE EUT Figure 1 General Appearance of the EUT Figure 2 General Appearance of the EUT R AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:TE7TDW8961NDV2 page Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F12029 14-2 Figure 3 General Appearance of the EUT Figure 4 General Appearance of the EUT R AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:TE7TDW8961NDV2 page Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F12029 14-3 Figure 5 General Appearance of the EUT Figure 6 General Appearance of the EUT R AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:TE7TDW8961NDV2 page Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F12029 14-4 Figure 7 General Appearance of the EUT Figure 8 General Appearance of the EUT R AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:TE7TDW8961NDV2 page Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F12029 14-5 Figure 9 General Appearance of the EUT Figure 10 General Appearance of the EUT

Internal Photos

R AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:TE7TDW8961NDV2 page Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F12029 14-6 Figure 11 Inside of the EUT Figure 12 Inside of the EUT R AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:TE7TDW8961NDV2 page Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F12029 14-7 Figure 13 Components Side of the PCB Figure 14 Components Side of the PCB R AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:TE7TDW8961NDV2 page Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F12029 14-8 Figure 15 Components Side of the PCB Figure 16 Power Adapter R AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:TE7TDW8961NDV2 page Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F12029 14-9 Figure 17 Power Adapter

RF Exposure Info

R AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:TE7TDW8961NDV2 page Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F12029 11-1 11. MPE ESTIMATION 11.1.Limit for General Population/ Uncontrolled Exposures Frequency Power density (mW/ cm 2 ) Averaging time(minutes) 300MHz----1.5GHz F/1500 30 1.5GHz---100GHz 1.0 30 Frequency(MHz) Power density (mW/ cm 2 ) Averaging time(minutes) 2412 1 30 2437 1 30 2462 1 30 Note: F= Frequency in MHz 11.2. Estimation Result EUT: 300Mbps Wireless N ADSL2+ Modem Router M/N: TD-W8961ND Test date:2012-02-25 Pressure: 101.6 kpa Humidity: 52.3% Tested by: Leo-Li Test site: RF Site Temperature:23.3°C Cable loss: 1 dB Attenuator loss: 20 dB Antenna Gain: 3 dBi Test Mode CH Frequency (MHz) Peak Output Power (dBm) Output Power (mW) Antenna Gain (dBi) Antenna Gain (Linear) MPE 11b CH1 2412 15.33 34.12 3 2.00 0.0136 CH6 2437 15.62 36.48 3 2.00 0.0145 CH11 2462 14.21 26.36 3 2.00 0.0105 11g CH1 2412 21.41 138.36 3 2.00 0.0549 CH6 2437 21.61 144.88 3 2.00 0.0575 CH11 2462 19.73 93.97 3 2.00 0.0373 11n HT20 CH1 2412 20.94 124.17 3 2.00 0.0493 CH6 2437 22.54 179.47 3 2.00 0.0713 CH11 2462 19.49 88.92 3 2.00 0.0353 11n HT40 CH1 2422 19.11 81.47 3 2.00 0.0324 CH4 2437 22.53 179.06 3 2.00 0.0711 CH7 2452 17.22 52.72 3 2.00 0.0209 Note: The estimation distance is 20cm

Test Report

R AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:TE7TDW8961NDV2 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F12029 FCC PART 15C TEST REPORT FOR CERTIFICATION On Behalf of TP-LINK TECHNOLOGIES CO., LTD. 300Mbps Wireless N ADSL2+ Modem Router Model No.: TD-W8961ND FCC ID: TE7TDW8961NDV2 Prepared for : TP-LINK TECHNOLOGIES CO., LTD. Building 24(floors 1,3,4,5) and 28 (floors1-4) Central Science and Technology Park, Shennan Rd, Nanshan, Shenzhen, China Prepared By : Audix Technology (Shenzhen) Co., Ltd. No. 6, Ke Feng Rd., 52 Block, Shenzhen Science & Industrial Park, Nantou, Shenzhen, Guangdong, China Tel: (0755) 26639496 Report Number : ACS-F12029 Date of Test : Feb.09~25, 2012 Date of Report : Mar.02, 2012 R AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:TE7TDW8961NDV2 Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F12029 TABLE OF CONTENTS Description Page 1. SUMMARY OF STANDARDS AND RESULTS ......................................................... 1-1 1.1. Description of Standards and Results ................................................................................... 1-1 2. GENERAL INFORMATION ......................................................................................... 2-1 2.1. Description of Device (EUT) ............................................................................................... 2-1 2.2. Test Information ................................................................................................................... 2-2 2.3. Tested Supporting System Details ........................................................................................ 2-3 2.4. Block Diagram of Test Setup ............................................................................................... 2-4 2.5. Test Facility .......................................................................................................................... 2-5 2.6. Measurement Uncertainty (95% confidence levels, k=2) ..................................................... 2-5 3. POWER LINE CONDUCTED EMISSION TEST ....................................................... 3-1 3.1. Test Equipments ................................................................................................................... 3-1 3.2. Block Diagram of Test Setup ............................................................................................... 3-1 3.3. Power Line Conducted Emission Test Limits ...................................................................... 3-1 3.4. Configuration of EUT on Test .............................................................................................. 3-2 3.5. Operating Condition of EUT ................................................................................................ 3-2 3.6. Test Procedure ...................................................................................................................... 3-2 3.7. Power Line Conducted Emission Test Results ..................................................................... 3-2 4. RADIATED EMISSION TEST ...................................................................................... 4-1 4.1. Test Equipment ..................................................................................................................... 4-1 4.2. Block Diagram of Test Setup ............................................................................................... 4-1 4.3. Radiated Emission Limit ...................................................................................................... 4-2 4.4. EUT Configuration on Test .................................................................................................. 4-3 4.5. Operating Condition of EUT ................................................................................................ 4-3 4.6. Test Procedure ...................................................................................................................... 4-3 4.7. Radiated Emission Test Results ........................................................................................... 4-4 5. CONDUCTED SPURIOUS EMISSIONS ..................................................................... 5-1 5.1. Test Equipment ..................................................................................................................... 5-1 5.2. Limit ..................................................................................................................................... 5-1 5.3. Test Procedure ...................................................................................................................... 5-1 5.4. Test result ............................................................................................................................. 5-1 6. BAND EDGE COMPLIANCE TEST ............................................................................ 6-1 6.1. Test Equipment ..................................................................................................................... 6-1 6.2. Limit ..................................................................................................................................... 6-1 6.3. Test Produce ......................................................................................................................... 6-1 6.4. Test Results .......................................................................................................................... 6-1 7. 6dB Bandwidth Test ........................................................................................................ 7-1 7.1. Test Equipment ..................................................................................................................... 7-1 7.2. Limit ..................................................................................................................................... 7-1 7.3. Test Procedure .............................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

R AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:TE7TDW8961NDV2 page Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F12029 13-1 13. PHOTOGRAPH OF TEST 13.1.Photos of Power Line Conducted Emission Test R AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:TE7TDW8961NDV2 page Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F12029 13-2 13.2.Photos of Radiated Emission Test R AUDIX Technology (Shenzhen) Co., Ltd. FCC ID:TE7TDW8961NDV2 page Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-F12029 13-3 (Above 1000MHz)

Contact Information

Applicant

Jing Huang(Regulatory Compliance Manager)
[email protected]75521534921Fax: 75526508930

Technical Contact

Audix TechnologyKen Lu
[email protected]86 775 26639497

52 Block Shenzhen Science and Industry · Shenzhen · China

Test Firm

Audix Technology (Shenzhen) Co., Ltd.Smart Tsai
[email protected]86-755-26639495Fax: 86-755-26632877

Technical Specifications

#Rule PartsFrequency RangePower Output
215C2.42 GHz - 2.45 GHz179.10 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is aggregate conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. Device is an 802.11n device in a 2x2 Spatial Multiplexing MIMO configuration as described in this filing. End-users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from TP-Link Technologies Co., Ltd.

AC750 Wi-Fi Range Extender, AC1200 Wi-Fi Range Extender - FCC ID TE7RE230V2 - TP-Link Technologies Co., Ltd.
TE7RE230V2

AC750 Wi-Fi Range Extender, AC1200 Wi-Fi Range Extender

Jan 13, 2021

Equipment Class

DTS - Digital Transmission System
AX1800 Dual-Band Wi-Fi 6 Router - FCC ID TE7AX20V2 - TP-Link Technologies Co., Ltd.
TE7AX20V2

AX1800 Dual-Band Wi-Fi 6 Router

Dec 22, 2020

Equipment Class

DTS - Digital Transmission System
AX1800 Wireless Dual-Band Gigabit Ceiling Mount Access Point - FCC ID TE7EAP620HD - TP-Link Technologies Co., Ltd.
TE7EAP620HD

AX1800 Wireless Dual-Band Gigabit Ceiling Mount Access Point

Dec 17, 2020

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Kasa Smart Wi-Fi Power Strip, 3-Outlet - FCC ID TE7KP303V2 - TP-Link Technologies Co., Ltd.
TE7KP303V2

Kasa Smart Wi-Fi Power Strip, 3-Outlet

Dec 15, 2020

Equipment Class

DTS - Digital Transmission System
AC1750 Wi-Fi Range Extender, AC1900 MU-MIMO Wi-Fi Range Extender - FCC ID TE7RE550 - TP-Link Technologies Co., Ltd.
TE7RE550

AC1750 Wi-Fi Range Extender, AC1900 MU-MIMO Wi-Fi Range Extender

Dec 03, 2020

Equipment Class

DTS - Digital Transmission System