FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. TP-Link Technologies Co., Ltd./
  3. TE7WA7510N

TE7WA7510N5GHz 150Mbps Indoor / Outdoor Wireless Access Point

TP-Link Technologies Co., Ltd.
5GHz 150Mbps Indoor / Outdoor Wireless Access Point - FCC ID TE7WA7510N - TP-Link Technologies Co., Ltd.
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Jan 10, 2013
Application Purpose
Original Equipment
Date of Application
Jan 08, 2013
Equipment Note
5GHz 150Mbps Indoor / Outdoor Wireless Access Point
Frequency Range
5745.00000000 - 5825.00000000
Company
TP-Link Technologies Co., Ltd.
Country
China

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

TL-WA7510N 5GHz 150Mbps Indoor/ Outdoor Wireless Access Point Rev: 1.0.0 1910010534 COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks or registered trademarks of their respective holders. No part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from TP-LINK TECHNOLOGIES CO., LTD. Copyright © 2012 TP-LINK TECHNOLOGIES CO., LTD. All rights reserved. http://www.tp-link.com FCC STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  Consult the dealer or an experienced radio/ TV technician for help. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment. FCC RF Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter. “To comply with FCC RF exposure compliance requirements, this grant is applicable to only Mobile Configurations. The antennas used for this transmitter must be installed to provide a separation distance of at least  cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.” CE Mark Warning This is a class B product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures. Industry Canada Statement: This device complies with RSS-210 of the Industry Canada Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2)This device must accept any interference received, including interference that may cause undesired operation. IMPORTANT NOTE: Radiation Exposure Statement: This equipment complies with Canada radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Ce dispositif est conforme à la norme CNR-210 d’Industrie Canada applicable aux appareils radio exempts de licence. Son fonctionnement est sujet aux deux conditions suivantes: (1) Le dispositif ne doit pas produire de brouillage préjudiciable, et (2) Ce dispositif doit accepter tout brouillage reçu,y compris un brouillage susceptible de provoquer un fonctionnement indésirable. NOTE IMPORTANTE: Déclaration d’exposition aux radiations: Cet équipement est conforme aux limites d’exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Korea Warning Statements: ╏䟊 ⶊ㍶㍺゚⓪ 㤊㣿㭧 㩚䕢䢒㔶 Ṗ⓻㎇㧊 㧞㦢UG NCC Notice: 15点ൟᓣ䁡䄝ড়ḐПԢࡳ⥛ᇘ丏䳏′′ˈ䴲15点䀅ৃˈ݀ৌǃଚ㰳៪Փ⫼㗙ഛϡᕫ᪙㞾䅞᳈丏⥛ǃࡴ໻ࡳ ⥛៪䅞᳈ॳ䀁㿜П⡍ᗻঞࡳ㛑DŽ Ԣࡳ⥛ᇘ丏䳏′′ПՓ⫼ϡᕫᕅ䷓亯㟾ᅝܼঞᑆ᫒ড়⊩䗮ֵ˗15点ⱐ⧒᳝ᑆ᫒⧒䈵ᰖˈឝゟेذ⫼ˈϺ ᬍ୘㟇⛵ᑆ᫒ᰖᮍᕫ㑐㑠Փ⫼DŽࠡ䷙ড়⊩䗮ֵˈᣛձ䳏ֵ⊩㽣ᅮ԰ὁП⛵㎮䳏䗮ֵDŽԢࡳ⥛ᇘ丏䳏 ′′䷜ᖡফড়⊩䗮ֵ៪Ꮉὁǃ里ᅌঞ䝿Ⱆ⫼䳏⊶䔏ᇘᗻ䳏′′䀁٭Пᑆ᫒DŽ TP-LINK TECHNOLOGIES CO., LTD TP-LINK TECHNOLOGIES CO., LTD. Building 24 (floors 1, 3, 4, 5), and 28 (floors 1-4) Central Science and Technology Park, Shennan Rd, Nanshan, Shenzhen, China DECLARATION OF CONFORMITY For the following equipment: Product Description: 5GHz 150Mbps Indoor/ Outdoor Wireless Access Point Model No.: TL-WA7510N Trademark: TP-LINK We declare under our own responsibility that the above products satisfy all the technical regulations applicable to the product within the scope of Council Directives: Directives 1999/5/EC, Directives 2004/108/EC, Directives 2006/95/EC, Directives 1999/519/EC, Directives 2011/65/EU The above product is in conformity with the following standards or other normative documents ETSI EN 300 328 V1.7.1: 2006 ETSI EN 301 489-1 V1.8.1:2008& ETSI EN 301 489-17 V2.1.1:2009 EN 55022:2006 +A1:2007 EN 55024:1998+A1:2001+A2:2003 EN 61000-3-2:2006+A1:2009+A2:2009 EN 61000-3-3:2008 EN60950-1:2006+A11:2009+A1:2010 EN62311:2008 The product carries the CE Mark: Person is responsible for marking this declaration: Yang Hongliang Product Manager of International Business Date of issue: 2012 I CONTENTS Package Contents ....................................................................................................1 Chapter 1 Introduction......................................................................................…

Text truncated - open the document above for the full version.

Users Manual

TL-WA7510N5GHz 150Mbps Indoor/ Outdoor Wireless Access Point User Guide 92  Connect Manually - You can configure the Device to make it connect or disconnect manually. After a specified period of inactivity (Max Idle Time), the Device will disconnect from your Internet connection, and you will not be able to re-establish your connection automatically as soon as you attempt to access the Internet again. To use this option, check the radio button. If you want your Internet connection to remain active at all time, enter "0" in the Max Idle Time field. Otherwise, enter the number of minutes that you wish to have the Internet connecting last unless a new link is requested.  Note: Sometimes the connection cannot be disconnected although you specify a time to Max Idle Time, because some applications are visiting the Internet continually in the background. Click the Save button to save your settings. 5. If your ISP provides PPTP connection, please select PPTP/Russia PPTP option. And you should enter the following parameters (Figure 5-21):  Figure 5-21 WAN – PPTP/Russia PPTP TL-WA7510N5GHz 150Mbps Indoor/ Outdoor Wireless Access Point User Guide 93  User Name/Password - Enter the User Name and Password provided by your ISP. These fields are case-sensitive.  Dynamic IP/ Static IP - Choose either as you are given by your ISP and enter the ISP’s IP address or the domain name.  If you choose static IP and enter the domain name, you should also enter the DNS assigned by your ISP. And click the Save button.  Click the Connect button to connect immediately. Click the Disconnect button to disconnect immediately.  Connect on Demand - You can configure the Device to disconnect from your Internet connection after a specified period of inactivity (Max Idle Time). If your Internet connection has been terminated due to inactivity, Connect on Demand enables the Device to automatically re-establish your connection as soon as you attempt to access the Internet again. If you wish to activate Connect on Demand, check the radio button. If you want your Internet connection to remain active at all times, enter “0” in the Max Idle Time field. Otherwise, enter the number of minutes you want to have elapsed before your Internet connection terminates.  Connect Automatically - Connect automatically after the Device is disconnected. To use this option, check the radio button.  Connect Manually - You can configure the Device to make it connect or disconnect manually. After a specified period of inactivity (Max Idle Time), the Device will disconnect from your Internet connection, and you will not be able to re-establish your connection automatically as soon as you attempt to access the Internet again. To use this option, click the radio button. If you want your Internet connection to remain active at all times, enter "0" in the Max Idle Time field. Otherwise, enter the number in minutes that you wish to have the Internet connecting last unless a new link is requested.  Note: Sometimes the connection cannot be disconnected although you specify a time to Max Idle Time because some applications are visiting the Internet continually in the background. Click the Save button to save your settings. 6. If your ISP provides BigPond Cable (or Heart Beat Signal) connection, please select BigPond Cable option. And then you should enter the following parameters as in Figure 5-22.  Note: This type of WAN Connection is only available in AP Router mode, but not in AP Client Router Mode. TL-WA7510N5GHz 150Mbps Indoor/ Outdoor Wireless Access Point User Guide 94 Figure 5-22 WAN – BigPond Cable  User Name/Password - Enter the User Name and Password provided by your ISP. These fields are case-sensitive.  Auth Server - Enter the authenticating server IP address or host name.  Auth Domain - Type in the domain suffix server name based on your location. NSW / ACT - nsw.bigpond.net.au VIC / TAS / WA / SA / NT - vic.bigpond.net.au QLD - qld.bigpond.net.au  MTU Size - The normal MTU (Maximum Transmission Unit) value for most Ethernet networks is 1500 Bytes. It is not recommended that you change the default MTU Size unless required by your ISP.  Connect on Demand - In this mode, the Internet connection can be terminated automatically after a specified inactivity period (Max Idle Time) and be re-established when you attempt to access the Internet again. If you want your Internet connection keeps active all the time, please enter “0” in the Max Idle Time field. Otherwise, enter the number of minutes you want to have elapsed before your Internet access disconnects.  Connect Automatically - The connection can be re-established automatically when it was down. TL-WA7510N5GHz 150Mbps Indoor/ Outdoor Wireless Access Point User Guide 95  Connect Manually - You can click the Connect/Disconnect button to connect/disconnect immediately. This mode also supports the Max Idle Time function as Connect on Demand mode. The Internet connection can be disconnected automatically after a specified inactivity period and re-established when you attempt to access the Internet again.  Click the Connect button to connect immediately. Click the Disconnect button to disconnect immediately.  Note: Sometimes the connection cannot be terminated although you specify a time to Max Idle Time because some applications are visiting the Internet continually in the background. Click the Save button to save your settings. 5.6.3 MAC Clone Choose menu “Network > MAC Clone”, and then you can configure the WAN MAC Address on the screen below, as shown in Figure 5-23:  Figure 5-23 MAC Address Clone  WAN MAC Address - This field displays the current MAC address of the WAN port. If your ISP requires that you register the MAC address of your adapter, please enter the correct MAC address into this field. Usually, you do not need to change anything here. The format for the MAC Address is XX-XX-XX-XX-XX-XX (X is any hexadecimal digit).  Your PC's MAC Address - This field displays …

Text truncated - open the document above for the full version.

Cover Letter(s)

TP-Link Technologies Co., Ltd. Building 24 (floors 1,3,4,5) and 28 (floors1-4), Central Science and Technology Park, Nanshan, Shenzhen, China AGENCY AUTHORIZATION LETTER FCC ID: TE7WA7510N Date:2012-12-31 To whom it may concern: We, the undersigned TP-Link Technologies Co., Ltd.,, hereby authorize Bureau Veritas Shenzhen Co. Ltd Dongguan Branch., to act on our behalf, as our agent, in the following matters related to the FCC approval of our products: report submittal, related correspondence, the signing of all documents relating to these matters, and any other lawful activity necessary to obtain such certification. Any act carried out by BVDG within the scope of this authorization shall have the same effects as our own. This authorization shall expire 6 months form original date. If you have any Questions regarding the authorization, please don’t hesitate to contact us. Thank you. Sincerely, _________________ Name: Yongquan Wang Company Name: TP-Link Technologies Co., Ltd. Tel.: +86-755-26502509 Fax.: +86-755-26508930 E-mail: [email protected]

Cover Letter(s)

TP-Link Technologies Co., Ltd. Building 24 (floors 1,3,4,5) and 28 (floors1-4), Central Science and Technology Park, Nanshan, Shenzhen, China Date: 2012-12-28 FCC ID: TE7WA7510N To the attention of Federal Communications Commission Authorization and Evaluation Division Confidentiality Request Pursuant to Sections 0.457 and 0.459 of the Commission’s Rules, the Applicant hereby requests confidential treatment of information accompanying this Application as outlined below: Schematics Block Diagram Operational Description The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the Applicant and provide unjustified benefits to its competitors. The Applicant understands that pursuant to Rule 0.457, disclosure of this Application and all accompanying documentation will not be made before the date of the Grant for this application. Sincerely yours, Name: Yongquan Wang TP-Link Technologies Co., Ltd. Tel.: +86-755-26502509 Fax.: +86-755-26508930 E-mail: [email protected]

External Photos

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 4 Report Version 1 Test Report No.: RF120625N003 PHOTOGRAPHS OF THE EUT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 4 Report Version 1 Test Report No.: RF120625N003 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 4 Report Version 1 Test Report No.: RF120625N003 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 4 Report Version 1 Test Report No.: RF120625N003

ID Label/Location Info

1 2 E D C B A 1 2 3 4 5 6 7 8 9 E D C 3 4 5 6 7 8 B A 9 料号: 设 计 审 核 颜 色 名 称 版 本 材 质 模 具 机型版本号 完成日期 logo 底色 文字 其它 记 录 与上一版的区别 TL-WA7510N产品规格标贴 A3 0.175哑面细砂纹PC+3M9473 TL-WA7510N 1.0欧 2011-12-21 修改产品名称,添加C-Tick、IC Number 及1588. 黑色 PANTONE COOLGRAY 1U 黑色 葛焕丽 54.7*17.8mm, 1R 文字转曲线 底色: PANTONE Cool Gray 1U 材质: 0.175哑面细砂纹PC+3M9473 文字转曲线 FCC ID:TE7WA7510N Default Settings: IP: 192.168.1.254 Username: admin Password: admin 5GHz 150Mbps Indoor/Outdoor Wireless Access Point This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. MADE IN CHINA N28505 IC:8853A-WA7510N Power: 12V 1A Model No.: TL - WA7510N Label Location

Internal Photos

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 4 Report Version 1 Test Report No.: RF120625N003 PHOTOGRAPHS OF THE EUT 、 、 ANT Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 4 Report Version 1 Test Report No.: RF120625N003 、 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 4 Report Version 1 Test Report No.: RF120625N003 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 4 Report Version 1 Test Report No.: RF120625N003

RF Exposure Info

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Test Report No.: FS120625N003 RF EXPOSURE REPORT Applicant TP-LINK TECHNOLOGIES CO.,LTD. Address Building 24 (floors 1,3,4,5) and 28 (floors 1-4) Central Science and Technology Park, Shennan Rd, Nanshan, Shenzhen, China Manufacturer or Supplier TP-LINK TECHNOLOGIES CO.,LTD. Address Building 24 (floors 1,3,4,5) and 28 (floors 1-4) Central Science and Technology Park, Shennan Rd, Nanshan, Shenzhen, China Product: 5GHz 150Mbps Indoor / Outdoor Wireless Access Point Brand Name: TP-LINK Model: TL-WA7510N Date of tests: Nov. 06 ~ Nov. 15, 2012 the tests have been carried out according to the requirements of the following standards: FCC Part 2 (Section 2.1091) FCC OET Bulletin 65, Supplement C (01-01) IEEE C95.1 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Prepared by Kent Liu Project Engineer / EMC Department Approved by Sam Tung Manager / EMC Department Date: Nov. 26, 2012 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Page 1 of 6 Report Version 1 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Test Report No.: FS120625N003 Table of Contents RELEASE CONTROL RECORD ................................................................................ 3 1. CERTIFICATION.............................................................................................. 4 2. RF EXPOSURE LIMIT .....................................................................................5 3. MPE CALCULATION FORMULA.....................................................................5 4. CLASSIFICATION ...........................................................................................5 5. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER...................6 Page 2 of 6 Report Version 1 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 3 of 6 Report Version 1 Test Report No.: FS120625N003 RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED RF120625N003 Original release Nov. 26, 2012 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 4 of 6 Report Version 1 Test Report No.: FS120625N003 1. CERTIFICATION PRODUCT: 5GHz 150Mbps Indoor / Outdoor Wireless Access Point MODEL: TL-WA7510N APPLICANT: TP-LINK TECHNOLOGIES CO.,LTD. TESTED: Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch TEST SAMPLE: ENGINEERING SAMPLE STANDARDS: FCC Part 2 (Section 2.1091) FCC OET Bulletin 65, Supplement C (01-01) IEEE C95.1 Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 5 of 6 Report Version 1 Test Report No.: FS120625N003 2. RF Exposure Limit LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) FREQUENCY RANGE (MHz) ELECTRIC FIELD STRENGTH (V/m) MAGNETIC FIELD STRENGTH (A/m) POWER DENSITY (mW/cm 2 ) AVERAGE TIME (minutes) LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE 300-1500 ... ... F/1500 30 1500-100,000 ... ... 1.0 30 F = Frequency in MHz 3. MPE calculation Formula Pd = (Pout*G) / (4*pi*r 2 ) where Pd = power density in mW/cm 2 Pout = output power to antenna in mW G = gain of antenna in linear scale Pi = 3.1416 R = distance between observation point and center of the radiator in cm 4. Classification The antenna of this product, under normal use condition, is at least 20cm away from the body of the user. So, this device is classified as Mobile Device. Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 6 of 6 Report Version 1 Test Report No.: FS120625N003 5. CALCULATION RESULT OF MAXIMUM CONDUCTED POWER FREQUENCY BAND (MHz) MAX POWER (mW) ANTENNA GAIN (dBi) DISTANCE (cm) POWER DENSITY (mW/cm 2 ) LIMIT (mW/cm 2 ) 802.11a CH 157 40.738 15 20 0.20357 1.00 802.11n 20MHz CH 165 35.645 15 20 0.22425 1.00 802.11n 40MHz CH 151 31.333 15 20 0.19712 1.00

Test Report

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 49 Report Version 1 Test Report No.: RF120625N003 TEST REPORT Applicant TP-LINK TECHNOLOGIES CO.,LTD. Address Building 24 (floors 1,3,4,5) and 28 (floors 1-4) Central Science and Technology Park, Shennan Rd, Nanshan, Shenzhen, China Manufacturer or Supplier TP-LINK TECHNOLOGIES CO.,LTD. Address Building 24 (floors 1,3,4,5) and 28 (floors 1-4) Central Science and Technology Park, Shennan Rd, Nanshan, Shenzhen, China Product 5GHz 150Mbps Indoor / Outdoor Wireless Access Point Brand Name TP-LINK Model TL-WA7510N Additional Model & Model Difference N/A Date of tests: Nov. 06 ~ Nov. 15, 2012 The submitted sample of the above equipment has been tested according to the requirements of the following standard: FCC Part 15, Subpart C (Section 15.247) CONCLUSION: The submitted sample was found to COMPLY with the test requirement Prepared by Kent Liu Project Engineer / EMC Department Approved by Sam Tung Manager / EMC Department Date: Nov. 26, 2012 This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 49 Report Version 1 Test Report No.: RF120625N003 TABLE OF CONTENTS RELEASE CONTROL RECORD ............................................................................................................ 3 1 SUMMARY OF TEST RESULTS.................................................................................................... 3 2 MEASUREMENT UNCERTAINTY................................................................................................. 3 3 GENERAL INFORMATION ............................................................................................................ 3 3.1 GENERAL DESCRIPTION OF EUT........................................................................................... 3 3.2 DESCRIPTION OF TEST MODES ............................................................................................. 3 3.2.1. CONFIGURATION OF SYSTEM UNDER TEST ............................................................... 3 3.2.2. TEST MODE APPLICABILITY AND TESTED CHANNEL DETAIL.................................... 3 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS ........................................................... 3 3.4 DESCRIPTION OF SUPPORT UNITS ....................................................................................... 3 4. TEST TYPES AND RESULTS........................................................................................................ 3 4.1 CONDUCTED EMISSION MEASUREMENT ............................................................................. 3 4.1.1 LIMITS OF CONDUCTED EMISSION MEASUREMENT ................................................. 3 4.1.2 TEST INSTRUMENTS....................................................................................................... 3 4.1.3 TEST PROCEDURES ....................................................................................................... 3 4.1.4 DEVIATION FROM TEST STANDARD ............................................................................. 3 4.1.5 TEST SETUP..................................................................................................................... 3 4.1.6 EUT OPERATING CONDITIONS ...................................................................................... 3 4.1.7 TEST RESULTS ................................................................................................................ 3 4.2 RADIATED EMISSION MEASUREMENT.................................................................................. 3 4.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT ...................................................... 3 4.2.2 TEST INSTRUMENTS....................................................................................................... 3 4.2.3 TEST PROCEDURES ....................................................................................................... 3 4.2.4 DEVIATION FROM TEST STANDARD ............................................................................. 3 4.2.5 TEST SETUP..................................................................................................................... 3 4.2.6 EUT OPERATING CONDITIONS ...................................................................................... 3 4.2.7 TEST RESULTS ..................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 1 of 3 Report Version 1 Test Report No.: RF120625N003 1 SET-UP FOR RADIATED EMISSION TEST <Frequency Range 30MHz~1GHz> Bureau Veritas Shenzhen Co., Ltd. Dongguan Branch No. 34, Chenwulu Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong 523942, China Tel.: +86 769 8593 5656 Fax: +86 769 8593 1080 Email: [email protected] Page 2 of 3 R…

Text truncated - open the document above for the full version.

Contact Information

Applicant

Jing Huang(Regulatory Compliance Manager)
[email protected]75521534921Fax: 75526508930

Technical Contact

Bureau VeritasJoyce Zeng
[email protected]8676985935656

No. 34 Chenwulu Section, Guantai Rd., Houjie Town · Dongguan Guangdong · China

Test Firm

Bureau Veritas Shenzhen Co., Ltd. Dongguan BranchAlec Hu
[email protected]86-769-85935656Fax: 86-769-85991080

Technical Specifications

#Rule PartsFrequency RangePower Output
115C5.75 GHz - 5.83 GHz40.70 mW
Confidentiality
Long Term
Grant Notes
Power Output listed is conducted. The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and not be co-located with any other transmitters except in accordance with FCC multi-transmitter product procedures. Only those antenna(s) tested with the device or similar antenna(s) with equal or lesser gain may be used with this transmitter. This device has both 20 MHz and 40 MHz bandwidth modes. End-users and installers must be provided with transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from TP-Link Technologies Co., Ltd.

AC750 Wi-Fi Range Extender, AC1200 Wi-Fi Range Extender - FCC ID TE7RE230V2 - TP-Link Technologies Co., Ltd.
TE7RE230V2

AC750 Wi-Fi Range Extender, AC1200 Wi-Fi Range Extender

Jan 13, 2021

Equipment Class

DTS - Digital Transmission System
AX1800 Dual-Band Wi-Fi 6 Router - FCC ID TE7AX20V2 - TP-Link Technologies Co., Ltd.
TE7AX20V2

AX1800 Dual-Band Wi-Fi 6 Router

Dec 22, 2020

Equipment Class

DTS - Digital Transmission System
AX1800 Wireless Dual-Band Gigabit Ceiling Mount Access Point - FCC ID TE7EAP620HD - TP-Link Technologies Co., Ltd.
TE7EAP620HD

AX1800 Wireless Dual-Band Gigabit Ceiling Mount Access Point

Dec 17, 2020

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Kasa Smart Wi-Fi Power Strip, 3-Outlet - FCC ID TE7KP303V2 - TP-Link Technologies Co., Ltd.
TE7KP303V2

Kasa Smart Wi-Fi Power Strip, 3-Outlet

Dec 15, 2020

Equipment Class

DTS - Digital Transmission System
AC1750 Wi-Fi Range Extender, AC1900 MU-MIMO Wi-Fi Range Extender - FCC ID TE7RE550 - TP-Link Technologies Co., Ltd.
TE7RE550

AC1750 Wi-Fi Range Extender, AC1900 MU-MIMO Wi-Fi Range Extender

Dec 03, 2020

Equipment Class

DTS - Digital Transmission System