FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Landis+Gyr Technologies, LLC/
  3. TEB-AIRPT652

TEB-AIRPT652RF Module for Utility Meter

Landis+Gyr Technologies, LLC
RF Module for Utility Meter - FCC ID TEB-AIRPT652 - Landis+Gyr Technologies, LLC
Click to zoom

Application Details

Equipment Class
DXX - Part 15 Low Power Communication Device Transmitter
Date of Grant
Apr 11, 2006
Application Purpose
Original Equipment
Date of Application
Apr 11, 2006
Equipment Note
RF Module for Utility Meter
Frequency Range
913.75000000 - 916.25000000
Company
Landis+Gyr Technologies, LLC
Country
United States

Documents & Files

Select a file to view

Users Manual

↗
↗

Cover Letter(s)

↗
↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

Test Report

↗
↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

iCon™ Form 2S and Form 12S MetersAssembly Diagram / Physical Description Assembly Diagram / Physical Description The AirPoint iCon Meter was designed to be assembled and disassembled without the use of tools. This modular design allows you to upgrade or repair a unit quickly and easily. The basic components of the iCon™ meter are depicted below and detailed following the diagram. MXU 530-E DISPLAY BOARD POWER SUPPLY BOARD Base Assembly The meter’s Base Assembly is molded from highly durable thermoplastics that provide a stable platform for the meter’s Sensor Module, Register display board and up to two additional option boards. The blades (or blade assembly) from the Sensor Module extend through the Base Assembly to connect to the service socket of the main power system. Sensor Module Power Supply The iCon™ meter uses a capacitive tap to provide a regulated voltage to the Sensor Module and the AirPoint iCon 0652 board. The power supply can withstand a voltage AIRPOINT ICON METER DISPLAY Assembly Diagram / Physical Description iCon™ Form 2S and Form 12S Meters transient as described in IEEE C62.41, Level C and applied in accordance with Section 5 of the ANSI C12.20-1998. Current Sensor Current is measured using a proprietary air-coupled current transformer. Sensor data, quantities proportional to the time derivative of the current, is streamed to the on-board metering chip. AirPoint iCon RF Board / Meter Display The RF Board / Meter Display consists of the AirPoint iCon radio board which is a frequency hopping radio operating in the 913.75MHz to 916.25MHz range. An LCD display is used to display the readings collected from the Sensor Module. Register Cover The Register Cover is an opaque shield that protects the meter’s internal boards from external tampering and serves as the mounting surface for the nameplate. With the exception of the LCD screen and test LED, no internal components can be viewed through the Register Cover. Nameplate The meter’s nameplate, which is compliant with ANSI C12.10 – 1997, includes a unique, factory-generated bar code that can be used in a billing database. Meter Cover The Meter Cover of each iCon™ meter unit is a transparent polycarbonate enclosure that is interchangeable, abrasion resistant, and contains UV inhibitors to prevent discoloration. This single-piece assembly locks with the Base Assembly to fully enclose the meter and protect the internal components from weather, the forces applied during installation and extraction, and the impact from a fall of up to five feet. After final calibration at the factory, the Meter Cover and Base Assembly are sealed with a T-bar, which will provide evidence of tampering.

Users Manual

.Hunt Technologies,Inc. 6436CountyRd.11 PequotLakes,MN56472 218.562.4877800.828.4055 Fax218.562.4878 www.hunttechnologies.com Tuesday,March28,2006 TerryGaston SensusMeteringSystems TerryGastouniotis 44CastilianDrive Goleta,CA93117 TheModelAirPointiConis installedin yourSensusiConElectricMetersasoriginalequipment.Wedo notsupplya manualwiththisunitbutwerequestthatthefollowingrequiredstatementsbeplacedin the SensusiConmanualtomeettherequirementsof theFederalCommunicationsCommissionCFR47,Part 15,andIndustryCanadaRSS-210. "ThisdevicecomplieswithPart15oftheFCCrules.Operationis subjecttothefollowingtwo conditions:1) Thisdevicemaynotcauseharmfulinterference,and,2)Thisdevicemustaccept anyinterferencereceivedincludinginterferencethatmaycauseundesiredoperation. ThisdevicecontainsFCCID:TEB-AIRPT652IIC:5931A-AIRPT652. CAUTIONTOUSER:ChangesormodificationsnotexpresslyapprovedbyHuntTechnologies, Inc.couldvoidtheuser'sauthoritytooperatetheequipment." Sincerely, J-fJO~ DaveOlson DirectorofEngineering Tele:(218)562-5547 Fax:(218)562-4878 [email protected] 6436CountyRd.11 PequotLakes,MN56472 218.562.4877800.828.4055 Fax218.562.4878 www.hunttechnologies.com Tuesday,March28,2006 TOVAmericaInc.FCB 10040MesaRimRoad SanDiegoCA92121USA DearSirorMadam: We,HuntTechnologies,6436CountyRoad11,PequotLakes,MN56472,arerequestingLimited ModularApproval(LMA)ontheAirPointiCon(AirPointtransmitterboard).TheAirPointiConis installedin theSensusiConelectricmeters.SensuswillcontrolthefinalinstallationbyrequiringthattheAirPoint iConbeinstalledintotheSensusiConmeterperHuntTechnologies'specificinstructions.Further,it will nottransmitRFenergyunlessit is in a SensusiConmeterduetothecomplexityofthecommunications protocolusedbetweenthetwo. NomanualexistsforthisproductsinceSensusis theintegrator.However,Sensuswillbeinstructedto includethefollowingregulatorynoticesin theirendproductmanuals: ThisdevicecomplieswithPart15oftheFCCRules.Operationissubjecttothefollowingtwo conditions:(1)Thisdevicemaynotcauseharmfulinterference,and(2)thisdevicemustaccept anyinterferencereceived,includinginterferencethatmaycauseundesiredoperation. ThisdevicecontainsFCCID:TEB-AIRPT652/ IC:5931A-AIRPT652. Caution:ChangesormodificationsnotexpresslyapprovedbyHuntTechnologiescouldvoidthe user'sauthorityto operatetheequipment. In addition,thewording"ContainsFCCID:TEB-AIRPT652/ IC:5931A-AIRPT652"willbeincludedonthe labelof thedevicein whichtheAirPointiConis installed. Sincerely,~v-JtJ~ DaveOlson DirectorofEngineering Tele:(218)562-5547 Fax:(218)562-4878 [email protected]

Cover Letter(s)

6436CountyRd.11 PequotLakes,MN56472 218.562.4877800.828.4055 Fax218.562.4878 www.hunttechnologies.com Monday,February20,2006 ComplianceCertificationServices Certification Division 561F MontereyRoad MorganHil~CA95037 Towhomit mayconcern: We,theundersigned,herebyauthorizeTHOMASN COKENIAS,d.b.a.T.N.Cokenias Consulting,toactonourbehalfinallmannersrelatingtoapplicationforequipmentauthorization throughtheCertificationDivisionofComplianceCertificationServices(CCS),includingsigning ofalldocumentsrelatingtothesematters.AnyandallactscarriedoutbyTHOMASN COKENIASonourbehalfshallhavethesameeffectas actsofourown. We,theundersigned,herebycertifythatwearenotsubjecttoa denialoffederalbenefits,that includesFCCbenefits,pursuanttoSection5301oftheAnti-DrugAbuseActof1988,21V.S.C. 853(a). InauthorizingTHOMASN COKENIASas ouragent,westillrecognizethatweareresponsibleto: .a) complywiththerelevantprovisionsofthecertificationprogram; b) makeallnecessaryarrangementsfortheconductoftheevaluation,including provisionforexa1niningdocumentationandaccesstoallareas,records(including internalauditreports)andpersonnelforthepurposesofevaluation(e.g.testing, inspection,assessment,surveillance,reassessment)andresolutionofcomplaints; c) makeclaimsregardingcertificationonlyin respectofthescopeforwhich certificationhasbeengranted; d) donotuseourproductcertificationin sucha mannerastobringtheCertification Divisionintodisreputeandnotmakeanystatementregardingourproduct certificationwhichtheCertificationDivisionmayconsidermisleadingor unauthorized; 6436CountyRd.11 PequotLakes,MN56472 218.562.4877800.828.4055 Fax218.562.4878 www.hunttechnologies.com f) e) uponsuspensionorcancellationofcertification,discontinueuseofalladvertising matterthatcontainsanyreferencetheretoandreturnanycertificationdocuments asrequiredbytheCertificationDivision; usecertificationonlytoindicatetheproductsarecertifiedasbeinginconformity withspecifiedstandards; g) endeavortoensurethatnocertificateorreportnoranypartthereofis usedina misleadingmanner; h) ensurethatanyreferenceto ourproductcertificationin communicationmedia suchasdocuments,brochuresoradvertising,complieswiththerequirementsof theCertificationDivision; i) keepa recordofallcomplaintsmadeknownto theusrelatingto theproduct's compliancewithrequirementsoftherelevantstandardandtomaketheserecords availabletotheCertificationDivisionwhenrequested; j)takeappropriateactionwithrespecttosuchcomplaintsandanydeficiencies foundin productsorservicesthataffectcompliancewiththerequirementsfor certification; k) documenttheactionstaken~ Thisauthorizationis validuntilfurtherwrittennotice fromtheapplicant. SincerelyYours, &~-, DaveOlson DirectorofEngineering Tele:(218)562-5547 Fax:(218)562-4878 [email protected]

Cover Letter(s)

tel: 650-726-1263 fax: 650-726-1252 [email protected] Thomas N. Cokenias EMC &Radio Approvals Test & Consulting Services for Commercial, Military, International Compliance P.O. Box 1086 El Granada, CA 94018 Compliance Certification Services 11 April 2006 561F Monterey Road Morgan Hill, CA 95037 Attention: Application Examiner Reviewing Engineer Applicant: Hunt Technologies Inc. FCC ID: TEB-AIRPT652 15.249 compliant 902-928 MHz RF Module To whom it may concern, Request is hereby submitted, per 0.457 and 0.459 of the Rules, on behalf of my client Hunt Technologies Inc. to withhold from public review certain portions of the application for equipment certification for the referenced FCC identifier. In particular, the following sections of the application and report are requested to be kept confidential: Block Diagrams Schematic Operational Description Rationale for request for confidentiality: Hunt Technologies has invested considerable time and materials in research and development to produce the referenced product. Disclosure of the confidential portions of this application to competitors would give them competitive advantage in developing similar products. If you have questions or need further information, please contact the undersigned. Sincerely, THOMAS N. COKENIAS EMC Consultant Agent for Hunt Technologies Inc.

Cover Letter(s)

Company: Hunt Technologies FCC ID: TEB-AIRPT652 Request for transmitter LIMITED modular approval Transmitter Module Characteristics Item Requirements EUT(sample answer) 1 Have its own RF shielding No shielding over RC circuitry 2 Have buffered modulation/data inputs (if such inputs are provided), All inputs to the modules are buffered through logic or microprocessor inputs. 3 Have it own power supply regulation Internal 3.6V and 5 V regulators, refer to schematic 4 Meet the antenna requirements of Section 15.203 Device is equipped with integrated circuit board antenna. 5 Be tested in a stand-alone configuration, i.e., the antenna, AC or DC power and data input/output lines must be connected to the module but, the module must not be inside another case during testing Device was tested on a test fixture board. Refer to test set-up photographs. 6 Be labeled with its own FCC ID number, and if the FCC ID is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module. Two proposed FCC ID label format are included in the filing. One of label is to be placed on the module and the other label is to be placed on the outside of system. Refer to FCC ID label format and location file. 7 The modular transmitter is manufactured so that the user cannot influence the operation of the transmitter that will operate outside of the scope of the regulations. Refer to “User’s Guide” Exhibit 8 Address compliance with the Commission's RF exposure limits in Sections 1.1310 and 2.1093. In addition, spread spectrum transmitters operating under Section 15.247 are required to address RF exposure compliance in accordance with Section 15.247(b)(4). The product meets 15.249 requirements, no RF exposure statements required in manual

External Photos

PRODUCT PHOTOGRAPHS FCC ID: TEB-AIRPT652 Brand name: AirPoint icon Model No.: 0652 IC: 5931A-AIRPT652 PRODUCT PHOTOGRAPHS

ID Label/Location Info

REV ISIO N S DWG REV . EC O #IM RF# SFTW D ESC RI P TI O N D RA FTER REV ISIO N DATE A PPRO V ED DATE A PPRO V ED 01 3365 SLD W RELEASE FOR QUOTE / PROTOTYPE - - - - B NO NE S. O ' BRY A N 01/ 18/ 06 - - - - - - - COMPANY: PA RT N O .DWG. NO. HUNT TECHNOLOGIES, INC. DO NOT SCALE DRAWING ( ) DENOTES REFERENCE ONLY. M UST BE FREE FRO M FLA SH A N D BURRS. UNLESS O THERWISE SPEC IFIED: DECIMAL FRACTION ANGLE 2 PL ? .03 ? 1/64 ?1 CHECKED BY:INITIA TO R: MANUFACTURING: DRAWN BY: QUALITY ASSURANCE: TO L EREN C ES O N : BREA K A LL SHA RP ED G ES. DIM ENSIO NS A RE IN INC HES TI TL E: DATED:DATED:DATED: DATED:DATED: PEQ UO T LAKES , M N 56472 DATED: SC A LE: SI ZE: THIS DOCUM ENT CONTAINS INFORM ATIONP RO P RI ETA RY TO H U N T TEC H N O LO G I ES I N C .A N Y U SE O R D I SC LO SU RE W I TH O U T W RI TTENPERM ISSIO N IS PRO HIBITED. NO TIC E: - 3 PL ? .15 LABL-00187 LA BL- 0 0 18 7 1 O F 1 SH EET: 01/ 18/ 06 NOTES:1. DESC RIPTIO N: SERIALIZED BAR C O DE LABEL..2. M ATERIAL: 2 M IL PO LYM IDE, TYPE TS866.3. DIG ITAL INKING SYSTEM FO R TEXT & BAR C O DE TO BE PERM ANENT BLAC K, U.V. RESISTANT.4. ARTWO RK LAYO UT TO BE LO C ATED AS SHO WN, AND TO BE APPRO VED BY HUNT ENG INEERING .5. 10 DIG IT SERIAL NO . TO BE IM PRINTED IN HUM AN READABLE FO RM BELO W THE SAM E INFO RM ATIO N IN C O DE 128C BAR C O DE AS SHO WN. THE C O DE 128 C O NSISTS O F A 2 DIG IT ERT TYPE (05) FO LLO WED BY AN 8 DIG IT I.D. S/ N WITH NO SPAC ES. (BARC O DE HEIG HT TO BE .150M IN). THE BAR C O DE C AN RUN O FF THE BO TTO M O F THE LABEL.6. FC C I.D. NUM BER TO BE LISTED AC RO SS THE TO P O F THE LABEL. 7. HUNT O R IT'S C O NTRAC TO RS WILL PRO VIDE SERIAL NUM BERS WITH EAC H PURC HASE.8. HUNT PRODUCT NAME AND REV LISTED AS SHOWN.9. LABEL M ANUFAC TURER: WHEN EAC H PURC HASE O RDER IS C O M PLETED, PRO VIDE THE VERIFIED RANG E & DATE C O M PLETED TO HUNT TEC HNO LO G IES M ANUFAC TURING ENG INEER O R PURC HASING .1 0 . TH E REV I SI O N A L P H A C H A RA C TER I S TH E P RO D U C T TRA C K I N G I . D . AND SHALL BE AS SHO WN O N THE LABEL IM AG E.1 1 . TH E " / V XX" REFLEC TS TH E V ERSIO N O F TH E FIRM W A RE LO A D ED O N TO THE I.C . THIS NUM ERIC VERSIO N M UST M ATC H THE LATEST VERSIO N FO R THE FIRM -00066.12. NARRO W BAR IS 10 M IL. LABEL, 0652 AirPo int SENSUS IC O N INTERIO R UN C O N TRO LLED 1.5 .5 8 LA YO UT PRO V ID ED BY HUN T. R .05 (O PTIO NAL). DO NOT PRINT BORDER. 5 11 10 6 FCC ID label location FCC ID: TEB-AIRPT652 FCC ID label REV ISIO N S DWG REV . EC O #IM RF# SFTW D ESC RI P TI O N D RA FTER REV ISIO N DATE A PPRO V ED DATE A PPRO V ED 01 3365 SLD W RELEASE FOR QUOTE / PROTOTYPE - - - - LABEL, 0652 AirPo int SENSUS ICON EXTERIOR B NO NE S. O ' BRY A N 01/ 18/ 06 - - - - - - - COMPANY: PA RT N O .DWG. NO. HUNT TECHNOLOGIES, INC. DO NOT SCALE DRAWING ( ) DENOTES REFERENCE ONLY. M UST BE FREE FRO M FLA SH A N D BURRS. UNLESS O THERWISE SPEC IFIED: DECIMAL FRACTION ANGLE 2 PL ? .03 ? 1/64 ?1 CHECKED BY:INITIA TO R: MANUFACTURING: DRAWN BY: QUALITY ASSURANCE: TO L EREN C ES O N : BREA K A LL SHA RP ED G ES. DIM ENSIO NS A RE IN INC HES TI TL E: DATED:DATED:DATED: DATED:DATED: PEQ UO T LAKES , M N 56472 DATED: SCALE: SIZE: THIS DOCUM ENT CONTAINS INFORM ATIONP RO P RI ETA RY TO H U N T TEC H N O LO G I ES I N C .A N Y U SE O R D I SC LO SU RE W I TH O U T W RI TTENPERM ISSIO N IS PRO HIBITED. NO TIC E: - 3 PL ? .15 LABL-00188 LA BL- 0 0 18 6 1 O F 1 SH EET: 01/ 18/ 06 NOTES:1. DESC RIPTIO N: SERIALIZED BAR C O DE LABEL..2. M ATERIAL: 2 M IL PO LYM IDE, TYPE TS866.3. DIG ITAL INKING SYSTEM FO R TEXT & BAR C O DE TO BE PERM ANENT BLAC K, U.V. RESISTANT.4. ARTWO RK LAYO UT TO BE LO C ATED AS SHO WN, AND TO BE APPRO VED BY HUNT ENG INEERING .5. 10 DIG IT SERIAL NO . TO BE IM PRINTED IN HUM AN READABLE FO RM BELO W THE SAM E INFO RM ATIO N IN C O DE 128C O R C O DE 39 BAR C O DE AS SHO WN. THE C O DE 128 O R C O DE 39 C O NSISTS O F A 2 DIG IT ERT TYPE (05) FO LLO WED BY AN 8 DIG IT I.D. S/ N WITH NO SPAC ES. (BARC O DE HEIG HT TO BE .150M IN). THE BAR C O DE C AN RUN O FF THE BO TTO M O F THE LABEL.6. FC C I.D. NUM BER TO BE LISTED AC RO SS THE TO P O F THE LABEL. 7. HUNT PRODUCT NAME AND REV LISTED AS SHOWN.8. LABEL M ANUFAC TURER: WHEN EAC H PURC HASE O RDER IS C O M PLETED, PRO VIDE THE VERIFIED RANG E & DATE C O M PLETED TO HUNT TEC HNO LO G IES M ANUFAC TURING ENG INEER O R PURC HASING .9 . - D ELETED -1 0 . - D ELETED -11. NARRO W BAR IS 10 M IL.12. THIS LABEL SHALL BE PRINTED BY SENSUS AND G ET PLAC ED O N THE O UTSIDE O F THE M ETER. I.D. WILL M ATC H THE I.D. O F THE AIRPO INT M O DULE THAT IS INSTALLED WITHIN. UN C O N TRO LLED 2.0 .56 7 LA YO UT PRO V ID ED BY HUN T. R .05 (O PTIO NAL). DO NOT PRINT BORDER. 5 6

Internal Photos

PRODUCT PHOTOGRAPHS FCC ID: TEB-AIRPT652 Brand name: AirPoint icon Model No.: 0652 IC: 5931A-AIRPT652 PRODUCT PHOTOGRAPHS

Test Report

Hunt Technologies AirPoint icon FCC ID: TEB-AIRPT652 IC: 5931A-AIRPT652 page1 Test Report for Unlicensed Low Power Transmitter Description of device: Electric meter wireless interface operating at 902-928 MHz FCC Applicable Rule Parts: 15.205, 15.207, 15.249 Applicant: Hunt Technologies 6436 County Rd. 11 Pequot Lakes, MN 56468 Telephone / Fax number: 218-562-5530 FCC ID: TEB-AIRPT652 Brand name: AirPoint icon Model No.: 0652 IC: 5931A-AIRPT652 TEST REQUIREMENTS The referenced device is subject to certification under Part 2 of FCC Rules. The specific emissions limits and test requirements are found in Part 15 of FCC Rules. In addition to the device specific requirements listed in 15.249 (re-printed below), the following Part 15 requirements are universal to all unlicensed transmitters and would also apply: 15.19 Labeling requirements 15.20 Accessories 15.21 Information to user 15.31 Measurement standards 15.33 Frequency range of measurements 15.35 Measurement detector functions and bandwidths 15.109 Radiated Emissions (unintentional radiators) 15.203 Antenna requirement 15.204 External radio frequency power amplifiers and antenna modifications. 15.205 Restricted bands of operation. 15.207 Conducted limits 15.209 Radiated emission limits, general requirements. The AirPoint icon meets all FCC requirements for a device of this type. THOMAS N. COKENIAS 23 February 2006 EMC and Radio Regulatory Consultant Agent for Hunt Technologies Hunt Technologies AirPoint icon FCC ID: TEB-AIRPT652 IC: 5931A-AIRPT652 page2 15.205 Restricted bands of operation. Only spurious emissions are permitted in any of the frequency bands listed below: The field strength of emissions appearing within these frequency bands shall not exceed the limits shown in Section 15.209. MHz MHz MHz GHz 0.090 - 0.110 10.495 - 0.505 2.1735 - 2.1905 4.125 - 4.128 4.17725 - 4.17775 4.20725 - 4.20775 6.215 - 6.218 6.26775 - 6.26825 6.31175 - 6.31225 8.291 - 8.294 8.362 - 8.366 8.37625 - 8.38675 8.41425 - 8.41475 12.29 - 12.293 12.51975 - 12.52025 12.57675 - 12.57725 13.36 - 13.41 16.42 - 16.423 16.69475 - 16.69525 16.80425 - 16.80475 25.5 - 25.67 37.5 - 38.25 73 - 74.6 74.8 - 75.2 108 - 121.94 123 - 138 149.9 - 150.05 156.52475 - 156.52525 156.7 - 156.9 162.0125 - 167.17 167.72 - 173.2 240 - 285 322 - 335.4 399.9 - 410 608 - 614 960 - 1240 1300 - 1427 1435 - 1626.5 1645.5 - 1646.5 1660 - 1710 1718.8 - 1722.2 2200 - 2300 2310 - 2390 2483.5 - 2500 2655 - 2900 3260 - 3267 3332 - 3339 3345.8 - 3358 3600 - 4400 4.5 - 5.15 5.35 - 5.46 7.25 - 7.75 8.025 - 8.5 9.0 - 9.2 9.3 - 9.5 10.6 - 12.7 13.25 - 13.4 14.47 - 14.5 15.35 - 16.2 17.7 - 21.4 22.01 - 23.12 23.6 - 24.0 31.2 - 31.8 36.43 - 36.5 15.109 Radiated emission limits, general requirements. Except as provided elsewhere in this paragraph the emissions from an intentional radiator shall not exceed the field strength levels specified in the following table: Frequency (MHz) Field Strength uV/m Measurement distance, m 0.009 - 0.490 0.490 - 1.705 1.705 - 30.0 30 - 88 88 - 216 216 - 960 Above 960 2400/F(kHz) 24000/F( 30 100 ** 150 ** 200 ** 500 300 30 30 3 3 3 3 ** Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this Section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz. Hunt Technologies AirPoint icon FCC ID: TEB-AIRPT652 IC: 5931A-AIRPT652 page3 Test Set-up Diagram EUT Battery pack (Radiated tests) Lab power supply (line conducted ) LISN Laptop to initialize EUT settings Hunt Technologies AirPoint icon FCC ID: TEB-AIRPT652 IC: 5931A-AIRPT652 page4 TEST EQUIPMENT LIST Name of EquipmentManufacturerModel No.Serial No.Due Date Spectrum Analyzer, 26.5 GHzHP8593EM3710A002057/26/06 Preamplifier, 1300 MHzHP8447D1937A020623/7/06 Antenna, Bilog 30 MHz ~ 2 GhzSunol SciencesJB1A1210033/3/06 Antenna, Horn 1 ~ 18 GHzEMCO311567174/22/06 Spectrum Analyzer 3 Hz ~ 44 GHzAgilentE4446AMY4530006410/19/06 Preamplifier, 1 ~ 26.5 GHzHP8449B3008A003698/17/06 LISN, 10 kHz ~ 30 MHzFCCLISN-50/250-25-20238/30/06 LISN, 10 kHz ~ 30 MHzSolar 8012-50-R-24-BN83794438/30/06 EMI Test ReceiverR & SESHS 20827129/0066/3/06 EMI Test ReceiverR & SESIB401001925/9/06 Hunt Technologies AirPoint icon FCC ID: TEB-AIRPT652 IC: 5931A-AIRPT652 page5 15.249 Operation within the bands 902 - 928 MHz, 2400 - 2483.5 MHz, 5725 - 5875 MHz, and 24.0 - 24.25 GHz. The field strength of emissions from intentional radiators operated within these frequency bands shall comply with the following table. Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated by at least 50 dB below the level of the fundamental or to the general radiated emission limits in Section 15.209, whichever is the lesser attenuation. Fundamental Frequency Field Strength, fundamental emission at 3 meters Field Strength, harmonics and spurious emissions at 3m 902-928 MHz 50,000 uV/m (94 dBuV/m) 500 uV/m (54 dBuV/m) 2400 - 2483.5 MHz 50,000 uV/m (94 dBuV/m) 500 uV/m (54 dBuV/m) 5725-5875 MHz 50,000 uV/m (94 dBuV/m) 500 uV/m (54 dBuV/m) 24.0 - 24.25 GHz 250,000uV/m (104 dBuV/m) 2500 uV/m (68 dBuV/m) 15.205, 15.209, 15.249 Radiated Emissions Radiated Test Set-up, 30 - 1000 MHz Antenna mast Ground plane 1 - 4 meters 3 meters turntable, laptop computer spectrum analyzer Test Procedures, 30 -1000 MHz Hunt Technologies AirPoint icon FCC ID: TEB-AIRPT652 IC: 5931A-AIRPT652 page6 The EUT was set to normal operating conditions (constantly transmitting). Radiated emissions from the EUT were measured according to the dictates of ANSI C63.4. Test Results Refer to plots and data sheets below. Hunt Technologies AirPoint icon FCC ID: TEB-AIRPT652 IC: 5931A-AIRPT652 page7 Fundamental Frequency emissions Hunt Technologies AirPoint icon FCC ID: TEB-AIRPT652 IC: 5931A-AIRPT652 page8 Fundamental Frequency emissions Hunt Technologies AirPoint icon FCC ID: TEB-AIRPT652 IC: 5931A-AIRPT652 page9 Fundamental Frequency emissions Hunt Technologies AirPoint icon FCC ID…

Text truncated - open the document above for the full version.

Test Report

RADIATED EMISSIONS Test Report #: WC502980 Run 2 Test Area: LTS EUT Model #: FASY-0622-0001-NS Date: 6/6/2005 EUT Serial #: 53000429 EUT Power: 220VAC / 60Hz Temperature: 23.0 °C Test Method: 15.249 Air Pressure: 98.0 kPa Customer: Hunt Technologies Rel. Humidity: 50.0 % EUT Description: Wireless Automatic Meter Reader Data File Name: 2980.dat Page: 1of 1 Tested by: Greg Jakubowski Printed Signature Reviewed by: Joel T. Schneider Printed Signature On time during 100mS File No. WC502907 Rev A, Page 24 of 34

Test Setup Photos

TEST SETUP PHOTOGRAPHS FCC ID: TEB-AIRPT652 Brand name: AirPoint icon Model No.: 0652 IC: 5931A-AIRPT652 battery pack Radiated test setup TEST SETUP PHOTOGRAPHS DC connection from laboratory AC-DC power supply

Contact Information

Applicant

Carl W Jacobi(Hardware Test Engineer)
[email protected]218-562-5125Fax: 218-562-4878

Test Firm

Compliance Certification Services IncSteve Cheng
[email protected]408-463-0885Fax: 408-463-0888

Technical Specifications

#Rule PartsFrequency RangePower Output
115C913.75 MHz - 916.25 MHz-
Modular Type
Limited Single Modular Approval
Confidentiality
Long Term
Grant Notes
Limited Modular Approval. This device is limited to use in Sensus iCon Electric Meters. Compliance of this device in any final configuration is the responsibility of the grantee.

Other Applications from Landis+Gyr Technologies, LLC

Utility Meter Transceiver Module - FCC ID TEB-HUNTGS10122 - Landis+Gyr Technologies, LLC
TEB-HUNTGS10122

Utility Meter Transceiver Module

Dec 06, 2011

Equipment Class

DTS - Digital Transmission System
FOCUS AX Modular Gridstream - FCC ID TEB-HUNTSU864 - Landis+Gyr Technologies, LLC
TEB-HUNTSU864

FOCUS AX Modular Gridstream

May 12, 2010

Equipment Class

DTS - Digital Transmission System
3G S4e Gridstream - FCC ID TEB-HUNTSU825 - Landis+Gyr Technologies, LLC
TEB-HUNTSU825

3G S4e Gridstream

Mar 07, 2010

Equipment Class

DTS - Digital Transmission System
TEB-HUNTTS764

TS2 Focus AX

Sep 15, 2009

Equipment Class

DTS - Digital Transmission System
Transmitter for Watt-Hour Meter - FCC ID TEB-HUNTSS762 - Landis+Gyr Technologies, LLC
TEB-HUNTSS762

Transmitter for Watt-Hour Meter

Jul 10, 2008

Equipment Class

DSS - Part 15 Spread Spectrum Transmitter