FCCID.CO- FCC ID Database
HomeCompaniesEquipment ClassesSearch

© 2026 FCC ID Database. All rights reserved.

AboutContactData sourced from FCC public records
  1. Home/
  2. Trilliant Networks/
  3. TMB-APR9F

TMB-APR9FNETWORK ACCESS POINT

Trilliant Networks
NETWORK ACCESS POINT - FCC ID TMB-APR9F - Trilliant Networks
Click to zoom

Application Details

Equipment Class
DTS - Digital Transmission System
Date of Grant
Feb 19, 2020
Application Purpose
Original Equipment
Date of Application
Feb 19, 2020
Equipment Note
NETWORK ACCESS POINT
Frequency Range
2402.00000000 - 2475.00000000
Company
Trilliant Networks
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

External Photos

↗

ID Label/Location Info

↗

Internal Photos

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

Trilliant Holdings, Inc. 401 Harrison Oaks Blvd., Suite 300 Cary, North Carolina 27513 NOTICE The contents of this document are proprietary and confidential and the property of Trilliant Holdings, Inc., its subsidiaries, affiliates, and/or licensors. This document is provided subject to the confidentiality obligations set forth in the agreement between your company and Trilliant. The contents may not be used or disclosed without the express written consent of Trilliant. Access Point Deployment Guide Models AP-R9-E and AP-R9-F System Release 2.1 Document Version 010-0021-00 Rev D NOTICE: The contents of this document are proprietary and confidential and the property of Trilliant Holdings, Inc., its subsidiaries, affiliates, and/or licensors. This document is provided subject to the confidentiality obligations set forth in the agreement between your company and Trilliant. The contents may not be used or disclosed without the express written consent of Trilliant. Proprietary Notice Copyright © Trilliant Holdings Inc. 2004 – 2019. All rights reserved. This document describes products, software and services (“Products”) of Trilliant Holdings Inc., its parents, subsidiaries, affiliates and/or its licensors. This document is licensed, not sold. Except as set out in the License or other written agreement between Trilliant and your company: (1) the purchase or use of a Product from Trilliant does not convey a license under any patent rights, copyrights, trademark rights, or any other of the intellectual property rights of Trilliant or third parties; (2) Trilliant does not assume any responsibility or liability arising out of the use of this document or any Product it describes; and (3) no part of the document may be disclosed in any form to any third party. Trilliant reserves the right to make changes to this document or to any Products it describes at any time with or without notice. Use, duplication, or disclosure by the U.S. Government is subject to restrictions of FAR 52.227- 14 (g) (2) (6/87) and FAR 52.227-19 (6/87), or DFAR 252.227-7015 (b) (6/95) and DFAR 227.7202-3 (a). Trilliant®, SecureMesh®, and UnitySuite® are registered trademarks of Trilliant. Any third- party name or mark mentioned in this document may be a trademark of its owners. January 25, 2019 10:14 AM Access Point Deployment Guide NOTICE: The contents of this document are proprietary and confidential and the property of Trilliant Holdings, Inc., its subsidiaries, affiliates, and/or licensors. This document is provided subject to the confidentiality obligations set forth in the agreement between your company and Trilliant. The contents may not be used or disclosed without the express written consent of Trilliant. How to Contact Trilliant Use the following methods to contact Trilliant: General Company and Solution Information: http://www.trilliant.com/ Trilliant Headquarters: Tel: +1 919.495.6111 Solution and Customer Support Portal: https://support.trilliant.com/ Note: Make all requests for Solution support or RMA processing through the web portal. If you do not have a Support Portal login and password, or need your credentials reset, contact Trilliant Support using the email address below. E-mail: [email protected] Note: This email address is not a primary means of communicating with Customer Support. Use it primarily to request access to the Support Portal (or to have access credentials reset). NOTICE: The contents of this document are proprietary and confidential and the property of Trilliant Holdings, Inc., its subsidiaries, affiliates, and/or licensors. This document is provided subject to the confidentiality obligations set forth in the agreement between your company and Trilliant. The contents may not be used or disclosed without the express written consent of Trilliant. Revision History Revision Date Description of change B April 26, 2017 This version is Trilliant rebranded version of the document version A previously issued by Ingenu. Minor naming updates to replace On-Ramp with Trilliant, minor formatting and spelling changes Removed or replaced all instances of “On-Ramp” and “ORW” with “Trilliant” “On-Ramp Total View” replaced with “OTV”. C September 26, 2018 • Updated footers and contact information. • Updated from model TRN-1000 to AP-R9-E and AP-R9-F models. • Deleted references to Access Point Product Specification (014- 0030-00), as TRN-1000 is no longer sold. • Updated reference to EMS Operator Guide 2.1 and document number. • Updated Figure 1. D January 24, 2019 Replaced Regulatory Warnings chapter with Safety and Compliance chapter. Moved chapter to Chapter 1. Access Point Deployment Guide v NOTICE: The contents of this document are proprietary and confidential and the property of Trilliant Holdings, Inc., its subsidiaries, affiliates, and/or licensors. This document is provided subject to the confidentiality obligations set forth in the agreement between your company and Trilliant. The contents may not be used or disclosed without the express written consent of Trilliant. Table of Contents Safety and Compliance ............................................................................................................................... 1 Safety Information .................................................................................................................................. 1 Compliance Notices ............................................................................................................................... 2 Modification Statement .................................................................................................................... 3 Inteference Statement....................................................................................................................... 3 FCC Class B Digital Device Notice ................................................................................................. 3 Wireless Notice ..........................................…

Text truncated - open the document above for the full version.

External Photos

www.nemko.com Nemko Canada Inc., a testing laboratory, is accredited by the Standards Council of Canada. The tests included in this report are within the scope of this accreditation External photos.docx; Date: May 2013 External photos 388860‐1RADWL Date of issue: Click here to enter a date. Applicant: Trilliant Networks Inc. Product: Access Point Model: AP‐R9‐F FCC ID: IC Registration number: TMB‐APR9F 6028A‐APR9F Section 1: External photos Report reference ID: 388860‐1RADWL Page φ of ϊ Section λ. External photos λ.λ Top front view Section 1: External photos Report reference ID: 388860‐1RADWL Page χ of ϊ λ.μ Top rear view Section 1: External photos Report reference ID: 388860‐1RADWL Page ψ of ϊ λ.ν Side View Section 1: External photos Report reference ID: 388860‐1RADWL Page ω of ϊ λ.ξ Top view Section 1: External photos Report reference ID: 388860‐1RADWL Page ϊ of ϊ

ID Label/Location Info

Access Point AP-R9-F Page 1 of 2 Front and back view Top view Access Point AP-R9-F Page 2 of 2 Bottom view Label

RF Exposure Info

Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 where:S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Maximum peak output power at device output terminal:26.12dBm Cable and Jumper loss:0.0dB Maximum peak output power at antenna input terminal:26.12dBm 409.2606597mW Single Antenna gain (typical):9 dBi Number of Antennae:1 Total Antenna gain (typical):9 dBi 7.943282347(numeric) Prediction distance:20cm Prediction frequency:2475MHz MPE limit for uncontrolled exposure at prediction frequency:1 mW/cm 2 Power density at prediction frequency:0.646741 mW/cm 2 6.467406W/m 2 Tx On time:1.000000ms Tx period time:1.000000ms Average Factor:100.000000% Average Power density at prediction frequency:6.467406 W/m 2 Maximum allowable antenna gain:10.89269855dBi Margin of Compliance:1.892698554dB 2 4R PG S π = ONE WORLDOURAPPROVAL

Test Report

www.nemko.com Nemko Canada Inc., a testing laboratory, is accredited by the Standards Council of Canada. The tests included in this report are within the scope of this accreditation FCC 15.247 and RSS-247.docx; Date: Apr 2019 MRA il ac SCC Accredited LAB LAB Accrédité CCN TM Choose Scandinavian trust Wireless test report – 388860-1TRFWL Applicant: Trilliant Networks Inc. Product type: Access Point Model: AP-R9-F FCC ID: IC Registration number: TMB-APR9F 6028A-APR9F Specifications:  FCC 47 CFR Part 15 Subpart C, §15.247 Operation in the 902–928 MHz, 2400–2483.5 MHz, and 5725–5850 MHz  RSS-247, Issue 2, Feb 2017, Section 5 Digital Transmission Systems (DTSs), Frequency Hopping Systems (FHSs) and Licence-Exempt Local Area Network (LE-LAN) Devices 5) Standard specifications for frequency hopping systems and digital transmission systems operating in the bands 902–928 MHz, 2400–2483.5 MHz and 5725–5850 MHz Date of issue: January 13, 2020 Avul Nzenza, EMC/Wireless Specialist Tested by Signature Andrey Adelberg, Senior Wireless/EMC Specialist Reviewed by Signature Report reference ID: 388860-1TRFWL Applicant: Trilliant Networks Canada Inc. Model: AP-R9-F Page 2 of 35 Test location(s) Company name Nemko Canada Inc. Site name Montreal Address 292 Labrosse Avenue City Pointe-Claire Province Quebec Postal code H9R 5L8 Country Canada Telephone +1 514 694 2684 Facsimile +1 514 694 3528 Toll free Website www.nemko.com Site number (3 m SAC) FCC: CA2041; IC: 2040G-5 Limits of responsibility Note that the results contained in this report relate only to the items tested and were obtained in the period between the date of initial receipt of samples and the date of issue of the report. This test report has been completed in accordance with the requirements of ISO/IEC 17025. All results contain in this report are within Nemko Canada’s ISO/IEC 17025 accreditation. Copyright notification Nemko Canada Inc. authorizes the applicant to reproduce this report provided it is reproduced in its entirety and for use by the company’s employees only. Any use which a third party makes of this report, or any reliance on or decisions to be made based on it, are the responsibility of such third parties. Nemko Canada Inc. accepts no responsibility for damages, if any, suffered by any third party as a result of decisions made or actions based on this report. © Nemko Canada Inc. Report reference ID: 388860-1TRFWL Applicant: Trilliant Networks Canada Inc. Model: AP-R9-F Page 3 of 35 Table of contents Table of contents .......................................................................................................................................................................................................... 3 Section 1. Report summary ................................................................................................................................................................................. 4 1.1 Applicant and manufacturer .................................................................................................................................................................................... 4 1.2 Test specifications .................................................................................................................................................................................................... 4 1.3 Test methods ............................................................................................................................................................................................................ 4 1.4 Statement of compliance ......................................................................................................................................................................................... 4 1.5 Exclusions ................................................................................................................................................................................................................. 4 1.6 Test report revision history ...................................................................................................................................................................................... 4 Section 2. Summary of test results ....................................................................................................................................................................... 5 2.1 FCC Part 15 Subpart C, general requirements test results ........................................................................................................................................ 5 2.2 FCC Part 15 Subpart C, intentional radiators test results for digital transmission systems (DTS) ............................................................................. 5 2.3 ISED RSS-Gen, Issue 5, test results............................................................................................................................................................................ 5 2.4 ISED RSS-247, Issue 2, test results for digital transmission systems (DTS) ................................................................................................................ 5 Section 3. Equipment under test (EUT) details ..................................................................................................................................................... 6 3.1 Sample information .................................................................................................................................................................................................. 6 3.2 EUT information ....................................................................................................................................................................................................... 6 3.3 Technical information ....................................................................................…

Text truncated - open the document above for the full version.

Test Setup Photos

www.nemko.com Nemko Canada Inc., a testing laboratory, is accredited by the Standards Council of Canada. The tests included in this report are within the scope of this accreditation setup photos.docx; Date: May 2013 Setup photos 388860‐3RADWL Date of issue: Click here to enter a date. Applicant: Trilliant Networks Inc. Product: Access Point Model: AP‐R9‐F FCC ID: IC Registration number: TMB‐APR9F 6028A‐APR9F Section 1: setup photos Report reference ID: 384947‐3RADWL Page φ of ω Section λ. Setup photos Radiated spurious (out‐of‐band) emissions setup photo – χτ to υτττ MHz Radiated spurious (out‐of‐band) emissions setup photo – χτ to υτττ MHz Section 1: setup photos Report reference ID: 384947‐3RADWL Page χ of ω Radiated spurious (out‐of‐band) emissions setup photo – above υ GHz Radiated spurious (out‐of‐band) emissions setup photo – above υ GHz Section 1: setup photos Report reference ID: 384947‐3RADWL Page ψ of ω Conducted emissions setup photo Section 1: setup photos Report reference ID: 384947‐3RADWL Page ω of ω Conducted emissions setup photo

Contact Information

Applicant

Daniel Tousignant(Certification & Compliance Eng.)
[email protected]450-915-1631Fax: 450-375-8746

Test Firm

Nemko Canada Inc. (Montreal)Charles Neal
[email protected]613-737-9680Fax: 613-737-9691

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz409.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. End-users and installers must be provided with antenna installation and transmitter operating conditions for satisfying RF exposure compliance.

Other Applications from Trilliant Networks

SecureMesh Wide Area Network - FCC ID TMB-WAN2000 - Trilliant Networks
TMB-WAN2000

SecureMesh Wide Area Network

Nov 05, 2020

Equipment Class

NII - Unlicensed National Information Infrastructure TX
Transceiver Module - FCC ID TMB-G30SGM30XA - Trilliant Networks
TMB-G30SGM30XA

Transceiver Module

Feb 02, 2014

Equipment Class

DTS - Digital Transmission System
Utility Meter - FCC ID TMB-G30I210 - Trilliant Networks
TMB-G30I210

Utility Meter

Mar 21, 2011

Equipment Class

DTS - Digital Transmission System
Wireless Electric Meter - FCC ID TMB-G30FOCUS - Trilliant Networks
TMB-G30FOCUS

Wireless Electric Meter

Jan 13, 2011

Equipment Class

DTS - Digital Transmission System
802.15.4 Transceiver Module - FCC ID TMB-EM000019 - Trilliant Networks
TMB-EM000019

802.15.4 Transceiver Module

Feb 14, 2007

Equipment Class

DTS - Digital Transmission System