Equipment Class
DTS - Digital Transmission System
Date of Grant
Mar 21, 2011
Application Purpose
Original Equipment
Date of Application
Mar 21, 2011
Equipment Note
Utility Meter
Frequency Range
2405.00000000 - 2475.00000000
Company
Trilliant Networks
Country
United States

Documents & Files

Select a file to view

Users Manual

↗

Cover Letter(s)

↗
↗

External Photos

↗

ID Label/Location Info

↗

Internal Photos

↗

RF Exposure Info

↗

Test Report

↗

Test Setup Photos

↗

Document Text

Text extracted from the exhibit documents filed with the FCC. Open a document above to read the original.

Users Manual

RES-3000-I210+ / I210+RD / I210+c PA-0115A Rev. 1.4 March 11th, 2011Page 1 of 6 Introduction This document will help the SecureMesh user to retrofit the product model RES-3000-I210+, RES-3000-I210+RD & RES-3000-I210+c in a GE I-210+, GE I-210+RD, GE I-210+c & GE I-210+cRD meter as intended. Safety and Assembly Cautions - Warning: The meter carries lethal voltages. The meter must be completely disconnected from any external circuits. Failure to observe this practice can result in serious injury or death. - Caution: These devices are electrostatic sensitive. It is best to use a grounded electrostatic mat and wrist strap to prevent electrostatic discharge. - Important: It is not necessary to completely separate the top of the meter from the base of the meter for this retrofit procedure. However, if the two parts are completely disconnected and separated, it is extremely important to keep each meter component together for re- assembly. This is due to the top section of the meter containing calibration “characterization” programming for the CTs in the meter base. If these components get mixed up with other meter components, current measurement errors will occur. SecureMesh Radio Specifications: • IEEE Standard : IEEE 802.15.4 • Power Output : +30 dBm • Radio Sensitivity : -99 dBm • RF Data rate : 250 kbps • Operating Frequency : 2.400-2.483 GHz • Network Topology : Mesh • Modulation : O-QPSK • Physical Dimensions : 2.54” x 3.47” • Antenna : Dipole, 3.5 dBi SecureMesh retrofit for GE I-210+ / I-210+RD / I-210+c / I-210+cRD meters RES-3000-I210+ / I210+RD / I210+c PA-0115A Rev. 1.4 March 11th, 2011Page 2 of 6 Industry Canada Compliance Statement (English & French) This device complies with industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device. "Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication." Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : 1. L’appareil ne doit pas produire de brouillage. 2. L’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. "Selon les règles d’Industrie Canada, cet appareil transmetteur radio peut seulement être en opération avec l’utilisation d’une antenne de type et d’un gain maximum (ou moindre) approuvée pour le transmetteur par Industrie Canada. Pour réduire l’interférence potentielle de la radio versus les autres utilisateurs, le type d’antenne et son gain devrait être choisis de façon à ce que la puissance isotrope irradiée équivalente (e.i.r.p.) ne soit pas supérieure à ce qui est requis pour avoir une bonne communication. " Federal Communication Commission Compliance Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. RES-3000-I210+ / I210+RD / I210+c PA-0115A Rev. 1.4 March 11th, 2011Page 3 of 6 FCC Warning Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. To comply with FCC and Industry Canada RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co- located or operating in conjunction with any other antenna or transmitter. Material • GE I-210+ or GE I-210+RD or GE I-210+c or GE I-210+cRD meters (must be AMR configured) • Trilliant SecureMesh RES-3000-I210+ or RES- 3000-I210+RD or RES-3000-I210+c. • Mounting Screws (HS-0013I) – QTY = 2 RES-3000-I210+ / I210+RD / I210+c PA-0115A Rev. 1.4 March 11th, 2011Page 4 of 6 Procedure Note: In this procedure, the “I-210+” wording will be used for all 4 meter designations: I-210+, I-210+RD, I-210+c & the I-210+cRD meters. The following table represents the Trilliant SecureMesh product associated to the GE meter: • RES-3000-I-210+ product must be installed into an I-210+ meter • RES-3000-I-210+RD product must be installed into an I-210+RD meter. • RES-3000-I-210+c product can be installed into an I-210+c …

Text truncated - open the document above for the full version.

Cover Letter(s)

Trilliant 1100 Island Drive Redwood City, CA 94065 Tel. +1.650.204.5050 Fax +1.650.508.8096 January 21, 2010 Federal Communications Commission Office of Engineering and Technology Equipment Authorization Division 7345 Oakland Mills Road Columbia, MD 21046 Subject: Permanent Confidentiality Request for FCC ID: TMB-G30I210 To Whom It May Concern: Pursuant to Sections 0.457 and 0.459 of CFR 47, the applicant requests permanent confidential treatment of the following information accompanying this application: • Block Diagram • Schematics • Theory of Operation The above materials contain trade secrets and proprietary information not customarily released to the public. The public disclosure of these matters might be harmful to the applicant, and provide unjustified benefits to its competitors. Sincerely, Paul Aubin Compliance & Certification Manager Trilliant Inc. Phone: 450-375-0556 x222 e-mail: [email protected]

Cover Letter(s)

____________________________________________________________________________________________________________________________________________________________________________ FCC AUTHORIZATION January 21, 2010 To: FCC Authorization & Evaluation Division 7435 Oakland Mills Road Columbia, MD 21045-0429 From: Paul Aubin Compliance & Certification Manager Tel.: 450-375-0556 x222 Fax: 450-375-8746 Applicant: Trilliant Networks, Inc. Dear Ladies and/or Gentlemen: I appoint Teresa White, Brian Petted and Kenneth Boston of LS Research, LLC to act as an agent in the preparation of applications under Part 15 of the rules and regulations of the Federal Communications Commission. I certify that the exhibitions properly describe the device being submitted under this application, and will implement any changes described in the test report. The labels described will be affixed to each item. By checking “yes”, the applicant certifies that, in the case of an individual applicant, he or she is not subject to a denial of federal benefits, including FCC benefits, pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 853(a); or, in the case of a non-individual applicant (e.g. corporation, partnership or other unincorporated association), no party to the application is subject to a denial of federal benefits, which includes FCC benefits, pursuant to that section. Yes No Sincerely, Paul Aubin Compliance & Certification Manager Trilliant Networks, Inc. Trilliant Networks 610 du Luxembourg Street Granby, Quebec Canada J2J 2V2 Tel. : 450-375-0556 Fax : 450-375-8746

External Photos

EXTERNAL PHOTOS Company Name Trilliant Networks, Inc. Model # RES!3000!1210 F C C ID # TMB-G30I210 IC # 6028B-G30I210 Page 1 of 2 Top of Unit Side of Unit EXTERNAL PHOTOS Company Name Trilliant Networks, Inc. Model # RES!3000!1210 F C C ID # TMB-G30I210 IC # 6028B-G30I210 Page 2 of 2 Bottom of Unit

ID Label/Location Info

RES-3000-I210+ March 11, 2011Page 1 of 1 FCC & IC Label SecureMesh™ 1-watt radio for GE I-210+® meter FCC & Industry Canada label PRODUC T SPECIFICA TION Material: 340 White Polyester for Durable Label Applications Description:This thermal transfer material is made from printing with our durable resin ribbons. Applications include, but are not limited to, instrumentmarking, long-term outdoor durable labels, asset- tracking and post-solder circuit board marking. It has also been tested for autoclaving pressure-wash applications up to 50°C. The face is scratch resistant and waterproof; the adhesive is aggressive and permanent. UL Recognized (File # MH27790) for indoor/outdoor use. RoHS Compliant. Recommended Printing Ribbons: T84, T96, T80 Resins (T80 for UL) FacestockAdhesiveLiner Type: Polyester Acrylic Sili cone paper Color:White, Gloss Caliper:0.002 inch0.0009 inch0.0031 inch Base Weight 42 lb / 3000 sq ft50# Brightness:75% Opacity:90% Min. Application Temperature+32°F (0°C) Service Temperature Range: -40°F to 302°F (-40°C to 150°C) Ultimate Tack:12 hours Storage Temperature Range:70°F (21°C) Humidity Range:50% R.H. Shelf Life:Two years Trilliant

Internal Photos

INTERNAL PHOTOS Company Name Trilliant Networks, Inc. Model # RES‐3000‐I210+ FCC ID # TMB‐G301210 IC # 6028A‐G301210 Page 1 of 5 Internal Photo of Meter Open Close‐up of RF Board and Main Board INTERNAL PHOTOS Company Name Trilliant Networks, Inc. Model # RES‐3000‐I210+ FCC ID # TMB‐G301210 IC # 6028A‐G301210 Page 2 of 5 Reverse Side of Main PCB Close‐up of RF Board INTERNAL PHOTOS Company Name Trilliant Networks, Inc. Model # RES‐3000‐I210+ FCC ID # TMB‐G301210 IC # 6028A‐G301210 Page 3 of 5 Side View of Antenna Reverse Side of Antenna INTERNAL PHOTOS Company Name Trilliant Networks, Inc. Model # RES‐3000‐I210+ FCC ID # TMB‐G301210 IC # 6028A‐G301210 Page 4 of 5 Backside of RF Board RF Board with Shield Removed INTERNAL PHOTOS Company Name Trilliant Networks, Inc. Model # RES‐3000‐I210+ FCC ID # TMB‐G301210 IC # 6028A‐G301210 Page 5 of 5 Close‐up of RF Section with Shield Removed

RF Exposure Info

Prediction of MPE limit at a given distance Equation from page 18 of OET Bulletin 65, Edition 97-01 where:S = power density P = power input to the antenna G = power gain of the antenna in the direction of interest relative to an isotropic radiator R = distance to the center of radiation of the antenna Maximum peak output power at the antenna terminal: 28.90(dBm) Maximum peak output power at the antenna terminal:776.2471166(mW) Antenna gain(typical):4.6(dBi) Maximum antenna gain:2.884031503(numeric) Prediction distance:20(cm) Prediction frequency: 2450(MHz) MPE limit for uncontrolled exposure at prediction frequency:1(mW/cm^2) Power density at prediction frequency:0.445379(mW/cm^2) Therefore device complies with FCC and Industry Canada RF radiation exposure limits for gereral population as a mobile device (distance > 20cm) 2 4R PG S π =

Test Report

W66 N220 Commerce Court ● Cedarburg, WI 53012 ● USA Phone: 262.375.4400 ● Fax: 262.375.4248 www.lsr.com TEST REPORT # Q310123 LSR Job #: C-903 Compliance Testing of: GE I-210+cRD SecureMesh with M-Antenna Test Date(s): December 5, 6, 2009, January 26, April 28, 29, May 11-13, 18-19, 2010 Prepared For: Trilliant Attn.: Eric Bourget 610 DU Luxembourg Granby, Quebec J2J 2V2 In accordance with: Federal Communications Commission (FCC) Part 15, Subpart C, Section 15.247 Industry Canada (IC) RSS 210 Annex 8 Digital Modulation Transmitters (DTS) Operating in the Frequency Band 2400 MHz – 2483.5 MHz This Test Report is issued under the Authority of: Signature: Date: 10.27.10 Test Report Reviewed by: Signature: Date: 10.27.10 Tested by: Peter Feilen, EMC Engineer Signature: Date: 10.27.10 This Test Report may not be reproduced, except in full, without written approval of LS Research, LLC. Prepared For:Trilliant EUT: SecureMesh High Efficiency I210+cRD LS Research, LLC Report # 310123 Model #: RES-3000-I210 Template: 15.109 Class B DTS RX 10-22-09 LSR Job #: C-903 Serial #: NDEB0000022 Page 2 of 54 TABLE OF CONTENTS (page 1 of 2) EXHIBIT 1: INTRODUCTION 1.1 Scope 4 1.2 Normative References 4 1.3 LS Research, LLC Test Facility 5 1.4 Location of Testing 5 1.5 Test Equipment Utilized 5 EXHIBIT 2: PERFORMANCE ASSESSMENT 2.1 Client Information 6 2.2 Equipment Under Test (EUT) Information 6 2.3 Associated Antenna Description 6 2.4 EUT’s Technical Specifications 7 2.5 Product Description 8 EXHIBIT 3: EUT OPERATING CONDITIONS & CONFIGURATIONS DURING TESTS 3.1 Climate Test Conditions 9 3.2 Applicability & Summary of EMC Emission Test Results 9 3.3 Modifications Incorporated in the EUT for Compliance Purposes 9 3.4 Deviations & Exclusions from Test Specifications 9 EXHIBIT 4: DECLARATION OF CONFORMITY 10 EXHIBIT 5: RADIATED EMISSIONS TESTING Note: Items 5.1 through 5.8 are for TRANSMIT MODE Item 5.9 is for RECEIVE MODE 5.1 Test Setup 12 5.2 Test Procedure 12 5.3 Test Equipment Utilized 13 5.4 Test Results 13 5.5 Calculation of Radiated Emissions Limits 14 5.6 Radiated Emissions Test Data Chart 15 5.7 Test Setup Photo(s) – Radiated Emissions Test 18 5.8 Screen Captures – Radiated Emissions Test 20 5.9 Receive Mode Testing 25 EXHIBIT 6: CONDUCTED EMISSIONS TEST, AC POWER LINE 6.1 Test Setup 26 6.2 Test Procedure 26 6.3 Test Equipment Utilized 26 6.4 Test Results 26 6.5 FCC Limits of Conducted Emissions at the AC Mains Ports 27 6.6 Conducted Emissions Test Data Chart 28 6.7 Test Setup Photo(s) – Conducted Emissions Test 29 6.8 Screen Captures – Conducted Emissions Test 30 Prepared For:Trilliant EUT: SecureMesh High Efficiency I210+cRD LS Research, LLC Report # 310123 Model #: RES-3000-I210 Template: 15.109 Class B DTS RX 10-22-09 LSR Job #: C-903 Serial #: NDEB0000022 Page 3 of 54 TABLE OF CONTENTS (Page 2 of 2) EXHIBIT 7: OCCUPIED BANDWIDTH 7.1 Limits 33 7.2 Method of Measurements 33 7.3 Test Equipment 33 7.4 Test Data 33 7.5 Screen Captures – Occupied Bandwidth 34 EXHIBIT 8: BAND-EDGE MEASUREMENTS 8.1 Method of Measurements 36 EXHIBIT 9: POWER OUTPUT (CONDUCTED): 15.247(b) 9.1 Method of Measurements 38 9.2 Test Equipment List 38 9.3 Test Data 38 9.4 Screen Captures – Power Output (Conducted) 39 EXHIBIT 10: POWER SPECTRAL DENSITY: 15.247(e) 10.1 Limits 10.2 Test Equipment List 10.3 Test Data 10.4 Screen Captures – Power Spectral Density EXHIBIT 11: SPURIOUS RADIATED EMISSIONS: 15.247(d) 11.1 Limits 11.2 Test Equipment List 11.3 Test Data 11.4 Screen Captures – Spurious Radiated Emissions EXHIBIT 12: FREQUENCY & POWER STABILITY OVER VOLTAGE & TEMPERATURE VARIATIONS EXHIBIT 13: CHANNEL PLAN & SEPARATION 13.1 Screen Captures – Channel Separation EXHIBIT 14: MPE CALCULATIONS APPENDICES APPENDIX A: TEST EQUIPMENT LIST APPENDIX B: TEST STANDARDS – RADIO APPENDIX C: UNCERTAINTY STATEMENT APPENDIX D: JUSTIFICATIONS OF AVERAGE DUTY FACTOR CALCULATIONS EXHIBIT 1. INTRODUCTION Prepared For:Trilliant EUT: SecureMesh High Efficiency I210+cRD LS Research, LLC Report # 310123 Model #: RES-3000-I210 Template: 15.109 Class B DTS RX 10-22-09 LSR Job #: C-903 Serial #: NDEB0000022 Page 4 of 54 1.1 SCOPE References: FCC Part 15, Subpart C, Section 15.247 Title: FCC : Telecommunication – Code of Federal Regulations, CFR 47, Part 15. Purpose of Test: To gain FCC and IC Certification Authorization for Low- Power License-Exempt Transmitters. Test Procedures: Both conducted and radiated emissions measurements were conducted in accordance with American National Standards Institute ANSI C63.4 – American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz. Environmental Classification: • Commercial, Industrial or Business • Residential 1.2 NORMATIVE REFERENCES Please see appendix B Prepared For:Trilliant EUT: SecureMesh High Efficiency I210+cRD LS Research, LLC Report # 310123 Model #: RES-3000-I210 Template: 15.109 Class B DTS RX 10-22-09 LSR Job #: C-903 Serial #: NDEB0000022 Page 5 of 54 1.3 LS Research, LLC TEST FACILITY LS Research, LLC is accredited by A2LA (American Association for Laboratory Accreditation) to conform to ISO/IEC 17025, 2005 “General Requirements for the Competence of Calibration and Testing Laboratories”. LS Research, LLC’s scope of accreditation includes all test methods listed herein, unless otherwise noted. A copy of the accreditation may be accessed on our web site: www.lsr.com . Accreditation status can be verified at A2LA’s web site: www.a2la2.net . 1.4 LOCATION OF TESTING All testing was performed at LS Research, LLC, W66 N220 Commerce Court, Cedarburg, Wisconsin, 53012 USA, utilizing the facilities listed below, unless otherwise noted. List of Facilities Located at LS Research, LLC: • Compact Chamber • Semi-Anechoic Chamber • Open Area Test Site (OATS) 1.5 TEST EQUIPMENT UTILIZED A complete list of equipment utilized in testing is provided in Appendix A of this test report. Calibration dates are indicated…

Text truncated - open the document above for the full version.

Test Setup Photos

TEST SETUP PHOTOS Company Name Trilliant Networks, Inc. Model # RES-3000-1210 FCC ID # TMB-G30I210 IC # 6028A-G30I210 Page 1 of 3 Test Setup Photo(s) – Radiated Emissions Test EUT on Test Pedestal TEST SETUP PHOTOS Company Name Trilliant Networks, Inc. Model # RES-3000-1210 FCC ID # TMB-G30I210 IC # 6028A-G30I210 Page 2 of 3 TEST SETUP PHOTOS Company Name Trilliant Networks, Inc. Model # RES-3000-1210 FCC ID # TMB-G30I210 IC # 6028A-G30I210 Page 3 of 3 Test Setup Photo – Conducted Emissions Test

Contact Information

Applicant

Daniel Tousignant(Certification & Compliance Eng.)
[email protected]450-915-1631Fax: 450-375-8746

Test Firm

LS Research, LLCRyan Urness
[email protected]262-375-4400Fax: 262-375-4248

Technical Specifications

#Rule PartsFrequency RangePower Output
115C2.40 GHz - 2.48 GHz776.00 mW
Confidentiality
Long Term
Grant Notes
Output power listed is conducted. This device must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. End-users and installers must be provided with installation and operating instructions for satisfying RF exposure compliance requirements.

Other Applications from Trilliant Networks

SecureMesh Wide Area Network - FCC ID TMB-WAN2000 - Trilliant Networks
TMB-WAN2000

SecureMesh Wide Area Network

Nov 05, 2020

Equipment Class

NII - Unlicensed National Information Infrastructure TX
NETWORK ACCESS POINT - FCC ID TMB-APR9F - Trilliant Networks
TMB-APR9F

NETWORK ACCESS POINT

Feb 19, 2020

Equipment Class

DTS - Digital Transmission System
Transceiver Module - FCC ID TMB-G30SGM30XA - Trilliant Networks
TMB-G30SGM30XA

Transceiver Module

Feb 02, 2014

Equipment Class

DTS - Digital Transmission System
Wireless Electric Meter - FCC ID TMB-G30FOCUS - Trilliant Networks
TMB-G30FOCUS

Wireless Electric Meter

Jan 13, 2011

Equipment Class

DTS - Digital Transmission System
802.15.4 Transceiver Module - FCC ID TMB-EM000019 - Trilliant Networks
TMB-EM000019

802.15.4 Transceiver Module

Feb 14, 2007

Equipment Class

DTS - Digital Transmission System